• 제목/요약/키워드: contact length

검색결과 755건 처리시간 0.028초

Size-controlled Chevrel Mo6S8 as Cathode Material for Mg Rechargeable Battery

  • Ryu, Anna;Park, Min-Sik;Cho, Woosuk;Kim, Jeom-Soo;Kim, Young-Jun
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권10호
    • /
    • pp.3033-3038
    • /
    • 2013
  • Nanoscale Chevrel $Mo_6S_8$ powders are synthesized by molten salt synthesis. Synthesized $Mo_6S_8$ powders have different mean particle sizes which are dependent on a ratio of salt to precursor. The particle sizes of $Mo_6S_8$ powders changes along with the ratio increase. $Mo_6S_8$ (6:1) demonstrates the best electrochemical characteristics among the synthesized $Mo_6S_8$ powders although the $Mo_6S_8$ (4:1) has the smallest particle size. $Mo_6S_8$ (6:1) shows a reversible capacity of 83.9 $mAhg^{-1}$, which is 27.5% and 33% improved value over $Mo_6S_8$ (2:1) and $Mo_6S_8$ (4:1) at a current density of 0.2C, respectively. The superior electrochemical properties of $Mo_6S_8$ (6:1) are attributed to the balanced particle size which provides proper contact area with electrolyte and the shortened $Mg^{2+}$ diffusion length. The $Mo_6S_8$ (4:1) has the smallest particle size but further reduction of particle size from $Mo_6S_8$ (6:1) is not advantageous.

호몰로지 조건을 이용하여 충격과 마모를 고려한 원자로 핵연료봉 지지격자의 최적설계 (Optimization of a Nuclear Fuel Spacer Grid Using Considering Impact and Wear with Homology Constraints)

  • 이현아;김종기;송기남;박경진
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2007년도 정기 학술대회 논문집
    • /
    • pp.145-150
    • /
    • 2007
  • The spacer grid set is a component in the nuclear fuel assembly. The set supports the fuel rods saftely. Therefore, the spacer gl1d set should have sufficient strength for the external impact forces. The fretting wear occurs between the spring of the fuel rod and the spacer grid due to tile flow-induced vibration. The conceptual design of the spacer grid set is performed based on the Independence Axiom of axiomatic design. Two functional requirements are defined and corresponding design parameters are selected. The overall flow of the design is defined according to the application of axiomatic design. The design for the impact load is carried out by using nonlinear dynamic analysis to determine the length of the dimple. Topology optimization is carried out to determine a new configuration of the spring. The fretting wear is reduced by shape optimization using the homology theory. In the design to reduce the fretting wear, the deformed shape of the spring should be the same as that of the fuel rod. This condition is transformed to a function and considered as a constraint in the shape optimization process. The fretting wear is expected to be reduced due to the homology constraint. The objective function is minimizing the maximum stress to allow a slight plastic deformation. Shape optimization results are confirmed through nonlinear static analysis because the contact area becomes wider.

  • PDF

외부 정수압을 받는 복수 원통의 연쇄 내파에 관한 실험연구 (Tests on the Serial Implosion of Multiple Cylinders Subjected to External Hydrostatic Pressure)

  • 태구무타퀴;박상현;손정민;조상래;노인식;이필승;조윤식
    • 대한조선학회논문집
    • /
    • 제57권4호
    • /
    • pp.213-220
    • /
    • 2020
  • In the present paper, implosion responses of two adjacent cylindrical tubes under external hydrostatic pressure were experimentally investigated. The cylinder models were fabricated of aluminium alloy 6061-T6 commercial tubes. In the experiment, a pair of two-cylinders were placed inside of a support frame in a medium-size pressure chamber, whose design pressure was 6.0MPa. The distance between the two-cylinders was 30 millimeter measured from outer shell at the mid-length. The implosion tests were performed with water and compressed nitrogen gas as the pressurizing media. The ambient static pressure of the chamber and local dynamic pressure near the two-imploded models were measured simultaneously. It was found that the energy released during an implosion from the first, weaker cylinder triggered the instability of the second, stronger cylinders. In other words, the resulting shock wave of the first implosive impact from the weaker cylinder could cause the premature failure of the neighboring stronger cylinders. The non-contact implosion phenomena from the two-cylindrical tube were clearly observed.

Short dental implants in the posterior maxilla: a review of the literature

  • Esfahrood, Zeinab Rezaei;Ahmadi, Loghman;Karami, Elahe;Asghari, Shima
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제43권2호
    • /
    • pp.70-76
    • /
    • 2017
  • The purpose of this study was to perform a literature review of short implants in the posterior maxilla and to assess the influence of different factors on implant success rate. A comprehensive search was conducted to retrieve articles published from 2004 to 2015 using short dental implants with lengths less than 10 mm in the posterior maxilla with at least one year of follow-up. Twenty-four of 253 papers were selected, reviewed, and produced the following results. (1) The initial survival rate of short implants in the posterior maxilla was not related to implant width, surface, or design; however, the cumulative success rate of rough-surface short implants was higher than that of machined-surface implants especially in performance of edentulous dental implants of length <7 mm. (2) While bone augmentation can be used for rehabilitation of the atrophic posterior maxilla, short dental implants may be an alternative approach with fewer biological complications. (3) The increased crown-to-implant (C/I) ratio and occlusal table (OT) values in short dental implants with favorable occlusal loading do not seem to cause peri-implant bone loss. Higher C/I ratio does not produce any negative influence on implant success. (4) Some approaches that decrease the stress in posterior short implants use an implant designed to increase bone-implant contact surface area, providing the patient with a mutually protected or canine guidance occlusion and splinting implants together with no cantilever load. The survival rate of short implants in the posterior edentulous maxilla is high, and applying short implants under strict clinical protocols seems to be a safe and predictable technique.

DRG 지불제도에 대한 미국의 경험과 우리 나라에의 시사점 (The U.S. Experience of the DRG Payment System and Suggestions to Korea)

  • 박은철;이선희;이상규
    • 한국병원경영학회지
    • /
    • 제7권1호
    • /
    • pp.105-120
    • /
    • 2002
  • In the United States, the prospective payment system(PPS), under which diagnosis related groups (DRGs) are used to reimburse hospitals for the care of Medicare patients since 1983, Study results showed that the PPS is having a major impact on the quantity of services especially of hospital length of stay. The PPS has increased the likelihood that a patient will be discharged home in an unstable condition and the use of nursing homes or long term care facilities increased. Still, it is insufficient to conclude that the PPS has decreased the Medicare total expenditure, but relatively sufficient to conclude that the quality of care hasn't changed. The maintenance of the quality resulted from the systemic "check-and-balance" composed of three factors; (1) The doctors are reimbursed based on the fee-for-service system, (2) hospitals contact with doctors under the attending system, and (3) there are some public hospitals. In Korea, the reimbursement for hospitals and doctors are not divided, the hospitals have doctors as employees, and 90% of hospitals are private. These differences may weaken the "check-and-balance" existing in the U.S. system. And there are few long term care facilities and the diagnostic coding system using in pilot test are not suitable for Korean situation. In conclusion, for successful implementation of the DRG payment system in Korea, the government should establish the "check-and-balance" system in the health sector to make sure the quality of care before the implementation.

  • PDF

산업용 로봇을 이용한 3차원 차체측정 시스템 (Three Dimension Car Body Measuring System Using Industrial Robots)

  • 김문상;조경래;박강;신현오
    • 대한기계학회논문집A
    • /
    • 제20권8호
    • /
    • pp.2555-2560
    • /
    • 1996
  • Inspecting the dimensional accuracy of a car-body in assembly line is a very important process to assure high productivity. Now there exist two common inspecting methods in practice. One is to measure a sampled car-body with three dimensional measuring machine, and the other is to measure car-body with three dimensional measuring machine, and the other is to measure car-body in assembly line using many sensors fixed to a large jig frame. The formal method takes too long to inspect a sampled car-body of a same sort, and cannot therefore give an useful error trend for the whole production. On the other hand, the latter lacks flexibility and is very cost-intensive. By using industrial robots and sensors, an in-line Car-Body Measuring(CBM) system which ensured high flexiblity and sufficient accuracy was developed. This CBM cell operates in real production line and measures the check points by the non-contact type using camera and laser displacement sensor(LDS). This system can handle about 15 Measuring points within a cycle time of 40 seconds. A process computer controls whole process such as data acquisition file handling and data analysis. Robot arms changes in length due to ambient temperature fluctuation affecting the measuring accuracy. To compensate this error, a robot arm calibration process was developed.

Histomorphometry and stability analysis of early loaded implants with two different surface conditions in beagle dogs

  • Kim, Dong-Seok;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra
    • The Journal of Advanced Prosthodontics
    • /
    • 제1권1호
    • /
    • pp.10-18
    • /
    • 2009
  • STATEMENT OF PROBLEM. Despite an improved bone reactions of Mg-incorporated implants in the animals, little yet has been carried out by the experimental investigations in functional loading conditions. PURPOSE. This study investigated the clinical and histologic parameters of osseointegrated Mg-incorporated implants in early loading conditions. MATERIAL AND METHODS. A total of 36 solid screw implants(diameter 3.75 mm, length 10 mm) were placed in the mandibles of 6 beagle dogs. Test groups included 18 Mg-incorporated implants. Turned titanium implants served as control. Gold crowns were inserted 4 weeks after implant placement and the dogs were immediately put on a food diet. Implants were observed for 10 weeks after loading. Radiographic assessments and stability tests were performed at the time of fixture installation, $2^{nd}$ stage surgery, 4 weeks after loading, and 10 weeks after loading. Histological observations and morphometrical measurements were also performed. RESULTS. Of 36 implants, 33 displayed no discernible mobility, corresponding to successful clinical function. There was no statistically significant difference between test implants and controls in marginal bone levels(P=.46) and RFA values. The mean BIC % in the Mg-implants was $54.5{\pm}8.4%$. The mean BIC % in the turned implant was $45.3{\pm}12.2%$. These differences between the Mg-implant and control implant were statistically significant(P=.005). CONCLUSIONS. The anodized, Mg-incorporated implant demonstrated significantly more bone-to-implant contact(BIC) in early loading conditions. CLINICAL IMPLICATIONS. The results of this study in beagle dogs suggest the possibility of achieving predictable stability of early loaded free-standing dental implants with Mg-incorporated surface.

온도 감지용 연필 선 종이 센서 최적화 연구 (Optimum Condition of Pencil Drawing Paper Sensor(PDPS) for Temperature Detecting)

  • 권동준;신평수;김종현;백영민;박하승;박종만
    • 접착 및 계면
    • /
    • 제18권1호
    • /
    • pp.1-7
    • /
    • 2017
  • 본 연구는 연필을 이용하여 연필 선 종이센서(pencil drawing paper sensor, PDPS)를 제작하였을 경우 센서로 활용하기 위한 기초연구를 실시하였다. PDPS를 제작하기 위한 기초 연구로 4B 조건이 최적이며, 연필 선의 길이는 20 mm 폭은 3 mm 조건이 적절하였다. 또한 종이는 A4조건이 최적이었으며, 접점의 안정화를 위해 스카치 테이프와 실버페이스트가 반드시 사용해야 데이터의 노이즈가 감소하였다. PDPS를 이용할 경우 온도에 대한 감지가 가능하였으며, 경험식으로 PDPS의 전기저항 변화도 결과와 온도 결과가 반비례 관계임을 확인하였다. 온도에 대한 PDPS 경험식을 바탕으로 복합재료의 성형단계에서의 확인한 PDPS의 전기저항 변화를 관찰하여 복합재료의 물성과의 상관관계를 확인하였다. 비교적 PDPS를 이용하여 복합재료의 기계적 및 계면 물성을 예측해 볼 수 있었다.

Ag Pastes의 분산 특성 및 스크린 인쇄된 OTFTs용 전극 물성 (Dispersion Characteristics of Ag Pastes and Properties of Screen-printed Source-drain Electrodes for OTFTs)

  • 이미영;남수용
    • 한국전기전자재료학회논문지
    • /
    • 제21권9호
    • /
    • pp.835-843
    • /
    • 2008
  • We have fabricated the source-drain electrodes for OTFTs by screen printing method and manufactured Ag pastes as conductive paste. To obtain excellent conductivity and screen-printability of Ag pastes, the dispersion characteristics of Ag pastes prepared from two types of acryl resins with different molecular structures and Ag powder treated with caprylic acid, triethanol amine and dodecane thiol as surfactant respectively were investigated. The Ag pastes containing Ag powder treated with dodecane thiol having thiol as anchor group or AA4123 with carboxyl group(COOH) of hydrophilic group as binder resin exhibited excellent dispersity. But, Ag pastes(CA-41, TA-41, DT-41) prepared from AA4123 fabricated the insulating layer since the strong interaction between surface of Ag powder and carboxyl group(COOH) of AA4123 interfered with the formation of conduction path among Ag powders. The viscosity behavior of Ag pastes exhibited shear-thinning flow in the high shear rate range and the pastes with bad dispersion characteristic demonstrated higher shear-thinning index than those with good dispersity due to the weak flocculated network structure. The output curve of OTFT device with a channel length of 107 ${\mu}m$ using screen-printed S-D electrodes from DT-30 showed good saturation behavior and no significant contact resistance. And this device exhibited a saturation mobility of $4.0{\times}10^{-3}$ $cm^2/Vs$, on/off current ratio of about $10^5$ and a threshold voltage of about 0.7 V.

AFM을 이용한 스트렙타비딘-바이오틴 단백질 복합체의 흡착 분석 (Absorption analysis of streptavidin-biotin complexes using AFM)

  • 박지은;김동선;최호진;신장규;김판겸;임근배
    • 센서학회지
    • /
    • 제15권4호
    • /
    • pp.237-244
    • /
    • 2006
  • Atomic force microscope (AFM) has become a common tool for the structural and physical studies of biological macromolecules, mainly because it provides the ability to perform experiments with samples in a buffer solution. In this study, structure of proteins and nucleic acids has been studied in their physiological environment that allows native intermolecular complexes to be formed. Cr and Au were deposited on p-Si (100) substrate by thermal evaporation method in sequence with the thickness of $200{\AA}$ and $500{\AA}$, respectively, since Au is adequate for immobilizing biomolecules by forming a self-assembled monolayer (SAM) with semiconductor-based biosensors. The SAM, streptavidin and biotin interacted each other with their specific binding energy and their adsorption was analyzed using the Bio-AFM both in a solution and under air environment. A silicon nitride tip was used as a contact tip of Bio-AFM measurement in a solution and an antimony doped silicon tip as a tapping tip under air environment. Actual morphology could also be obtained by 3-dimensional AFM images. The length and agglomerate size of biomolecules was measured in stages. Furthermore, $R_{a}$ (average of surface roughness) and $R_{ms}$ (mean square of surface roughness) and surface density for the adsorbed surface were also calculated from the AFM image.