• Title/Summary/Keyword: contact effect

Search Result 3,294, Processing Time 0.035 seconds

Annealing Effect on controlling Self-Organized Ag/Ti Nanoparticles on 4H-SiC Substrate (4H-SiC기판 위의 자기구조화된 Ag/Ti 나노입자 제어를 위한 열처리 분석)

  • Kim, So-Mang;OH, Jong-Min;Koo, Sang-Mo
    • Journal of IKEEE
    • /
    • v.20 no.2
    • /
    • pp.177-180
    • /
    • 2016
  • The effect of varying thickness of Ag/Ti metal bilayer and annealing time have investigated for controlling self-organized nanoparticles (NPs) on 4H-SiC substrate. In addition, Glass and Si substrate which have different surface energy from SiC were fabricated for analyzing interaction of agglomeration. The results of FE-SEM indicated the different formation behaviors of NPs in various ranges of fabrication condition. The surface energy was measured by using a Contact Angle Analyzer. The formation of network-like NPs was observed on Glass and 4H-SiC, respectively, whereas it was not the case on Si substrates. It has been found that the size of NPs increases with decreasing surface energy, due to particle size-dependent hydrophilic properties of substrates. The different formation behavior was explained by using Young's equation for the contact angles between the metal and different substrates.

Efficient Shadow-Test Algorithm for the Simulation of Dry Etching and Topographical Evolution (건식 식각 공정 시뮬레이션을 위한 효율적인 그림자 테스트 알고리즘과 토포그래피 진화에 대한 연구)

  • Kwon, Oh-Seop;Ban, Yong-Chan;Won, Tae-Young
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.2
    • /
    • pp.41-47
    • /
    • 1999
  • In this paper, we report 3D-simulations of a plasma etching process by employing cell-removal algorithm takes into account the mask shadow effect os well as spillover errors. The developed simulator haas an input interface to take not only an analytic form but a Monte Carlo distribution of the ions. The graphic user interface(GUI) was also built into the simulator for UNIX environment. To demonstrate the capability of 3D-SURFILER(SURface proFILER), we have simulated for a typical contact hole structure with 36,000($30{\times}40{\times}30$) cells, which takes about 20 minutes with 10 Mbytes memory on sun ultra sparc 1. as an exemplary case, we calculated the etch profile during the reactive ion etching(RIE) of a contact hole wherein the aspect ratio is 1.57. Furthermore, we also simulated the dependence of a damage parameter and the evolution of topography as a function of the chamber pressure and the incident ion flux.

  • PDF

Elastic Behavior of Contact Lense(I) : Effect of Vibration (콘택트 렌즈의 탄성에 관한 연구(I) : 진동에 의한 영향)

  • Kim, Dase-Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.2
    • /
    • pp.1-16
    • /
    • 1999
  • Differential equations and its numerical solution program using Turbo-C were formulated to describe the radical distribution and average displacement amplitude of vibrating dehydrated contact lens(HEMA) driven by sinusoidal or rectangular pressure. The natural resonant frequency of the lens diaphram(thickness 0.08mm, diameter 14mm, curvature radius 8mm) was measured to be 5730 Hz from the extrapolation of frequency vs addedmass to the diaphram curve. The Young's modulus of the lens was measured to be $4{\times}10^9$ Pa with altering the original shape. The effect of parameters such as thickness, effective radius, damping coeff., amplitude of driving pressure on the vibration characteristics was illustrated by the computer simulation of the derived program. When the frequency of driving pressure coincides with the integral multiple of fundamental resonance frequency of the lens the wave pattern changes from arc to bell-shape along the radial position of the diaphram. If this happens to the contact lens on the cornea in vivo, it might create the feel of pull of the lens due to the increased rise of central part of the lens.

  • PDF

Effect of Ozone Treatment on Dyeability of Polyethylene Film (오존 처리가 폴리에틸렌 필름의 염색성에 미치는 영향)

  • 박수진;신준식;김학용;이덕래
    • Polymer(Korea)
    • /
    • v.27 no.2
    • /
    • pp.98-105
    • /
    • 2003
  • The surface energy and the effect of functional groups on the surface of the ozone-treated low-density polyethylene (LDPE) film were studied. Treatment conditions were treatment time, total amount of transferred ozone, and ozone concentration. The introduction of polar groups on the surface of LDPE film after ozone treatment was confirmed by FTIR-ATR and XPS analyses. Surface fee energy of the LDPE film was examined by a contact angle method. The ozone treated-LDPE film showed a decreased water contact angles about 15$^{\circ}$ mainly due to the increased concentration of oxygen-containing functional groups, which was attributed to the increased surface free energy or $O_{IS}/C_{IS}$Also, the concentrations of the oxygen-containing functional groups on the surface of LDPE film increased with ozone treatment time and concentration, whereas no significant effects were found for the total amount of transferred ozone. From the dyeability test using Kubelka-Munk equation, it was found that the ozone treatment plays an important role in the growth of oxygen-containing functional groups of LDPE film, resulting in the improvement of dyeability for basic dyeing agent.

The Effect of Head Posture Change on Initial Occlusal Contact in Temporomandibular Disorder Patient (측두하악 장애환자에서 두부자세 변화가 초기 교합접촉에 미치는 영향)

  • Weon-Ho Choi;Woo-Cheon Kee
    • Journal of Oral Medicine and Pain
    • /
    • v.20 no.2
    • /
    • pp.489-496
    • /
    • 1995
  • The purpose of this study was to evaluate an effect of change on head posture initial occlusal contacts with measuring the distances between initial occlusal contacts and maximum intercuspal position at different head posture in TMDs patient. For this study, 24 patients from age 13 to 36 were selected, they were examined health history taken, patients who have sign and symptoms of TMDs were examine before the study. For the normal group, 21 adults from age 23 to 25 were selected. They have normal or class I molar relationship, and have no other prosthetic restorations. Difference on distance between initial occlusal contact and maximum intercuspal position with mandibular kinesiograph$(MKG^R)$(K6 diagnostic system, Myo-tronic Inc, USA) in upright, supine, 45$^{\circ}$ extension, 30$^{\circ}$ flexion position of the head were measured. The Frankfort horizontal plane was used as a reference plane. The results were as follows : 1. There were significant differences between initial occlusal contacts of the normal and patient group on upright position and 30$^{\circ}$ flexion of the head(p<0.05, p<0.01) 2. The position of the initial occlusal contacts have a tendency to place anterior and inferior to maximal intercuspal position in upright position and 30( flexion of the head as well as posterior and inferior in supine position and 45$^{\circ}$ extension of the head in the normal and patient groups. 3. There were significant differences among the initial occlusal contacts between uptight and supine position; upright and 45$^{\circ}$ extension of the head(p<0.05); supine position and 30$^{\circ}$ flexion of the head, .and 30(flexion and 45$^{\circ}$ extension of the head in the patient group(p<0.01) The result have shown that after treatment on the supine position, it may be necessary to check occlusal contact on the upright position as well ass flexion of the head. It may need careful adjustment in occlusal condition on upright position of TMDs patient.

  • PDF

An analytical solution for the close-contact melting with vertical convection and solid-liquid density difference (종방향대류 및 고액밀도차가 고려된 접촉융해에 대한 해석해)

  • Yu, Ho-Seon;Hong, Hui-Gi;Kim, Chan-Jung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.9
    • /
    • pp.1165-1173
    • /
    • 1997
  • The steady state close-contact melting phenomenon occurring between a phase change material and an isothermally heated flat plate with relative motion is investigated analytically, in which the effects of vertical convection in the liquid film and solid-liquid density difference are incorporated simultaneously. Not only the scale analysis is conducted to estimate a priori qualitative dependence of system variables on characteristic parameters, but also an analytical solution to a set of simplified model equations is obtained to specify the effects under consideration. These two results are consistent with each other, in that the vertical convection affects both the solid descending velocity and the film thickness, and that the density difference alters only the solid descending velocity. While the effect of vertical convection can be characterized conveniently by a newly introduced temperature gradient factor which asymptotically approaches the unity/zero with decreasing/increasing the Stefan number, that of density difference is represented by the liquid-to-solid density ratio. It is shown that the solid descending velocity depends linearly on the density ratio, and that the ratios of solid descending velocity, film thickness and friction coefficient to the conduction solution are proportional to 3/4, 1/4 and -1/4 powers of the temperature gradient factor, respectively. Also, established is the fact that the effect of convection can be legitimately neglected in the analysis for the range of the Stefan number less than 0.1.

Review on the buoyancy effect of the multi purpose double-deck tunnels during operation (운영중 다목적 복층터널의 부력영향 검토)

  • Kim, Ho-jong;Kim, Hyeon-ah;Joo, Eun-jung;Shin, Jong-ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.6
    • /
    • pp.623-635
    • /
    • 2015
  • Double-deck tunnels beneath the groundwater table have relatively large volume and commonly constructed as watertight tunnels. In this case, it requires to secure stability of the tunnels for buoyant force. Generally the contact force between lining and ground is sufficient to resist the buoyant force. However in the long-term the contact force could be reduced because of structural deterioration. In this study the effect of long-term buoyant force acting on the double-deck tunnel is investigated. The results has shown that the buoyant force has increased invert deformation and stress. It is indicated that the contact resilience between lining and ground needs to be kept during tunnel operation.

Finite element analysis on bio-mechanical behavior of composite bone plate for healing femur fracture considering contact conditions (접촉조건을 고려한 대퇴골 치료용 복합재료 고정판의 생체 역학적 거동에 관한 유한요소해석)

  • Kim, Suk-Hun;Chang, Seung-Hwan
    • Composites Research
    • /
    • v.23 no.1
    • /
    • pp.1-7
    • /
    • 2010
  • In this paper, finite element analyses for estimating the behavior of fractured femur just after the operation were carried out by using ABAQUS 6.71. A stainless steel bone plate and composite bone plates with various stacking angles were considered to find out the effect of bone plate properties on bone fracture healing. In order to simulate the actual state, contact conditions between the plate and bone and fractured bones were imposed on the finite element models and the whole analysis was divided by two steps; screw fastening step and load bearing step. The stress and strain distributions at the fracture site for the cases of the stainless steel and composite bone plates were analyzed and compared with. From the analyses it was found that the composite bone plate had potential advantages for effective bone fractures healing relieving stress shielding effect.

Immobilization and Grafting of Acrylic Acid on Polyethylene Surface by Ar-plasma Treatment (알곤 플라즈마처리에 의한 폴리에틸랜 표면상의 아크릴산 고정화와 그라프팅)

  • 김민정;서은덕
    • Polymer(Korea)
    • /
    • v.26 no.2
    • /
    • pp.279-286
    • /
    • 2002
  • For surface modification of polymers with hydrophilic functional groups, acrylic acid was grafted and immobilized on the surface of polyethylene(PE) by cold-plasma treatment using Ar gas. The modifications were identified by analysis of ATR-IR spectrum and by the measurement of contact angles. Compared to virgin PE significant decreases in contact angle were observed for both the grafted PE and the immobilized PE. The decreases of contact angle were in the range of 47~$53^{\circ}$ for grafted PE and 23~$26^{\circ}$ for immobilized PE. The degree of hydrophilicity depended strongly on the plasma-treating time and discharge power. For the case of grafting it has show that the longer plasma-treating time, the higher hydrophilic character. For the case of immobilization, whereas, higher discharge power and longer exposure to plasma have shown the detrimental effect for the preparation of hydrophilic PE surface due to the decrease of carboxyl group by ablation effect. The decrease in adhesion strength of immobilized PE. compared to grafted PE, was also attributed to the ablation of carboxyl group.

A Study on Direct Current Measurement Using Magneto-Optical LMF Method (자기장학 누설자속법을 응용한 직류전류계측법에 관한 연구)

  • Lee, Jin-Yi
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.6
    • /
    • pp.566-572
    • /
    • 2004
  • It is necessary to measure the direct current with a non-contact methodology for the liquid or gas phase, as welt as the conducting metals. This paper described a theoretical consideration and experimental verification for a non-contact quantitative direct current measurement system using the Faraday effect and magnetic flux leakage. The leakage of magnetic flux occurs around a gap when a ferromagnetic core including the discontinuous gap is magnetized. Two large anisotropic domains in a magneto-optical film are occurred by the vertical component of leaked magnetic flux and the domain walls are paralleled to the center of the gap. Here, the symmetrical arrangement of domains are deflected when a vertical magnetic field is applied to the magneto-optical film. The domain wall of the magneto-optical film are relocated when a measuring current passes through the ferromagnetic core. Therefore, a direct current passing through the core can be determined quantitatively by the measurement of moving distance of the domain wall.