• Title/Summary/Keyword: contact effect

Search Result 3,294, Processing Time 0.028 seconds

Dynamic response of a Timoshenko beam on a tensionless Pasternak foundation

  • Coskun, Irfan;Engin, Hasan;Tekin, Ayfer
    • Structural Engineering and Mechanics
    • /
    • v.37 no.5
    • /
    • pp.489-507
    • /
    • 2011
  • The dynamic response of a Timoshenko beam on a tensionless Pasternak foundation is investigated by assuming that the beam is subjected to a concentrated harmonic load at its middle. This action results in the creation of lift-off regions between the beam and the foundation that effect the character of the response. Although small displacements for the beam and the foundation are assumed, the problem becomes nonlinear since the contact/lift-off regions are not known at the outset. The governing equations of the beam, which are coupled in deflection and rotation, are obtained in both the contact and lift-off regions. After removing the coupling, the essentials of the problem (the contact regions) are determined by using an analytical-numerical method. The results are presented in figures to demonstrate the effects of some parameters on the extent of the contact lengths and displacements. The results are also compared with those of Bernoulli-Euler, shear, and Rayleigh beams. It is observed that the solution is not unique; for a fixed value of the frequency parameter, more than one solution (contact length) exists. The contact length of the beam increases with the increase of the frequency and rotary-inertia parameters, whereas it decreases with increasing shear foundation parameter.

A Case of Allergic Contact Dermatitis Aggravated by Steroid Ointment (스테로이드 외용제로 악화된 알레르기성 접촉피부염 치험 1례)

  • Song, Mi-Sa;Yoon, Hwa-Jung;Ko, Woo-Shin
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.31 no.3
    • /
    • pp.107-115
    • /
    • 2018
  • Objectives : The purpose of this paper is to report the effect of Korean medicine treatments on allergic contact dermatitis aggravated after applying steroid ointment. Methods : We treated a 63-year-old woman with allergic contact dermatitis on the both forearm, jaw, neck, chest with Korean medicine. Before Korean medicine treatments she has taken oral steroids and applied steroid ointment for several years to treat dermatitis, but long-tern steroid therapy aggravated her symptoms like skin pruritus, erythema, exudates or edema. After Korean medical treatment for 27 days, we found that the size of erythema was reduced, and symptoms like pruritus, exudates and edema were lost. We recorded pictures of changes on symptoms. Results & Conclusions : The symptoms of allergic contact dermatitis were improved. Erythema, edema, exudate were lost. Thus Korean medicine treatments are effective on allergic contact dermatitis and could be a great alternative to steroid treatment.

Analysis of the Static Friction Coefficient of Contacting Rough Surfaces in Miniature Systems (거친 면 접촉의 정적 마찰계수 해석)

  • 김태종
    • Tribology and Lubricants
    • /
    • v.19 no.4
    • /
    • pp.230-236
    • /
    • 2003
  • In applications such as MEMS and NEMS devices, the adhesion force and contact load may be of the same order of magnitude and the static friction coefficient can be very large. Such large coefficient may result in unacceptable and possibly catastrophic adhesion, stiction, friction and wear. To obtain the static friction coefficient of contacting real surfaces without the assumption of an empirical coefficient value, numerical simulations of the contact load, tangential force, and adhesion force are preformed. The surfaces in dry contact are statistically modeled by a collection of spherical asperities with Gaussian height distribution. The asperity micro-contact model utilized in calculation (the ZMC model), considers the transition from elastic deformation to fully plastic flow of the contacting asperity. The force approach of the modified DMT model using the Lennard-Jones attractive potential is applied to characterize the intermolecular forces. The effect of the surface topography on the static friction coefficient is investigated for cases rough, intermediate, smooth, and very smooth, respectively. Results of the static friction coefficient versus the external force are presented for a wide range of plasticity index and surface energy, respectively. Compared with those obtained by the GW and CEB models, the ZMC model is more complete in calculating the static friction coefficient of rough surfaces.

A Study on the Contact Stress Analysis for X-ring (X-ring의 접촉 응력 해석에 관한 연구)

  • Lee, Hyun-Seung;Lee, Young-Shin;Lee, Jung-Hyun;Chun, Byong-Sun;Baek, Joon-Ho;Kim, Suk-Yoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.9
    • /
    • pp.733-739
    • /
    • 2008
  • The X-ring is a elastomer with X-shaped cross-section used as a mechanical seal or gasket. Such a X-ring was equipped in a groove and compressed between two or more parts, acts as a seal on the interface. This study aims to detect contact stress and deformed shape of a X-shaped ring shell under various compressive contact conditions. A contact stress analysis was carried out by finite element analysis. The effect of compression rates and thickness design variable was analyzed. X-ring kept up the double seal until a compression rate of 20%. The maximum stresses of the X-ring was occurred at the top and bottom corner. The maximum contact stress of X-ring was rapidly increased according with the compression rate. The X-rings with thickness design variable from 1.3 mm to 1.5 mm had comparative low stress levels.

Effect of Coating Thickness on Rolling Contact Fatigue of CNx Coated Steel (CNx코팅된 강의 회전접촉피로에 미치는 코팅두께의 영향)

  • Choi, Byung Young;Umehara, Noritsugu
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.13 no.5
    • /
    • pp.355-359
    • /
    • 2000
  • Ion beam assisted deposition system was used to deposit CNx coatings with various thickness on the substrates of high-frequency induction hardened steels. Rolling contact fatigue tests were performed using Polymet RCF-1 machine with a constant supply of lubricant. Rolling contact fatigue life was substantially different in the steels with various thickness of CNx coatings. The optimum thickness of CNx coating was found to be $8.9{\mu}m$, showing the longest fatigue life, mainly caused by higher resistance to initiation of cracks and protective overcoat remaining to the surface failure during rolling contact fatigue. Cracks were initiated in the substrates under the surface of wear track and propagated to the surface, which eventually resulted in the failure. The reduction of fatigue life observed in the specimen with elimination of CNx coating during rolling contact fatigue was explained by the substrates deformation.

  • PDF

A Case Study of Chronic Contact Dermatitis from Cement, Treated with Taeeumin Cheonghyeolgangki-tang (태양인(太陰人) 청혈강기탕(淸血降氣湯) 투여 후 호전된 시멘트 접촉 만성 피부염 환자 치험 1례)

  • Kang, Ki-wan;Kim, Min-ji;Kang, Sei-young
    • The Journal of Internal Korean Medicine
    • /
    • v.36 no.1
    • /
    • pp.49-57
    • /
    • 2015
  • Objectives : The purpose of this report is to investigate the effect of Taeeumin Cheonghyeolgangki-tang on chronic contact dermatitis caused by cement. Methods : A 52-year-old male patient was diagnosed with contact dermatitis with the Questionnaire for Sasang Constitutional Classification-II (QSCC-II) as well as the four methods of diagnosis (四診), and treated with Taeeumin Cheonghyeolgangki-tang (qīngxuèjiàngqí-tāng). We observed redness and scaling on both palms, and recorded photographs of any changes during the inpatient and outpatient treatment period. Results : The symptoms of contact dermatitis on both palms were significantly improved. Scaling and cracked skin disappeared and the redness almost resolved. Conclusions : Therefore, Taeeumin Cheonghyeolgangki-tang ( qīngxuèjiàngqí-tāng ) is effective on chronic contact dermatitis caused by cement.

Evaluation of Friction Properties According to Normal Force and Direction of Wood Grain in Real Contact Area

  • Park, Chun-Young;Kim, Chul-Ki;Kim, Hyung-Kun;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.39 no.5
    • /
    • pp.437-443
    • /
    • 2011
  • In Korea, there has been a traditional post and beam wood construction with large roof load. Because a large friction is generated in wooden joint or members, it is important to evaluate the friction between wood members according to wood direction. Because most of studies have been concerned with friction between wood and steel, excluding effect of real area of contact, there are a few studies on the friction between wood members. The object of this study was to evaluate friction or coefficient of friction according to normal force and real area of contact of wood. With Japanese larch (Larix kaempferi) test specimens, five steps of normal force and combinations of test were prepared. Results indicated that normal force had almost no affection on the friction, however there was difference about friction or coefficient of friction according to real contact conditions of wood grain and contact area.

Effect of Surface Treatments of Polycrystalline 3C-SiC Thin Films on Ohmic Contact for Extreme Environment MEMS Applications (극한 환경 MEMS용 옴익 접촉을 위한 다결정 3C-SiC 박막의 표면 처리 효과)

  • Chung, Gwiy-Sang;Ohn, Chang-Min
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.3
    • /
    • pp.234-239
    • /
    • 2007
  • This paper describes the TiW ohmic contact characteristics under the surface treatment of the polycrystalline 3C-SiC thin film grown on $SiO_2/Si(100)$ wafers by APCVD. The poly 3C-SiC surface was polished by using CMP(chemical mechanical polishing) process and then oxidized by wet-oxidation process, and finally removed SiC oxide layers. A TiW thin film as a metalization process was deposited on the surface treated poly 3C-SiC layer and was annealed through a RTA(rapid thermal annealing) process. TiW/poly 3C-SiC was investigated to get mechanical, physical, and electrical characteristics using SEM, XRD, XPS, AFM, optical microscope, I-V characteristic, and four-point probe, respectively. Contact resistivity of the surface treated 3C-SiC was measured as the lowest $1.2{\times}10^{-5}{\Omega}cm^2$ at $900^{\circ}C$ for 45 sec. Therefore, the surface treatments of poly 3C-SiC are necessary to get better contact resistance for extreme environment MEMS applications.

Low resistivity ohmic Pt/Si/Ti contacts to p-type 4H-SiC (Pt/Si/Ti P형 4H-SiC 오옴성 접합에서 낮은 접촉 저항에 관한 연구)

  • Yang, S.J.;Lee, J.H.;Nho, I.H.;Kim, C.G.;Cho, N.I.;Jung, K.H.;Kim, E.D.;Kim, N.K.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.521-524
    • /
    • 2001
  • In this letter. we report on the investigation of Ti. Pt/Si/Ti Ohmic contacts to p-type 4H-SiC. The contacts were formed by a 2-step vacuum annealing at $500^{\circ}C$ for 1h. $950^{\circ}C$ for 10 min respectively. The contact resistances were measured using the transmission line model method. which resulted in specific contact resistivities in the $3.5{\times}10^{-3}$ and $6.2{\times}10^{-4}ohm/cm^{2}$, and the physical properties of the contacts were examined using x-ray diffraction. microscopy. AES(auger electron spectroscopy). AES analysis has shown that, at this anneal temperature, there was a intermixing of the Ti and Si. migration of into SiC. Overlayer of Pt had the effect of decreasing the specific contact resistivity and improving the surface morphology of the annealed contact.

  • PDF

Effect of Contact Pressure on the Variations in Coefficients of Friction Between Porcine Knee Joint Cartilage and Co-Cr Alloy in a Repeat Pass Sliding Motion (반복 회전운동에서 코발트 크롬 합금과 미끄럼 접촉하는 돼지 무릎 관절연골의 접촉압력이 마찰계수 변화에 미치는 영향)

  • Lee, Kwon-Yong;Kim, Hwan;Lee, Young-Ze
    • Tribology and Lubricants
    • /
    • v.25 no.4
    • /
    • pp.231-235
    • /
    • 2009
  • In this study, the influence of contact pressure on the variation in coefficients of friction between porcine knee joint cartilage and Co-Cr alloy in a repeat pass sliding motion was investigated. Flat-ended cartilage pin specimens(9 mm diameter, 8 mm long) were prepared from porcine(6 months old) knee joints by a drill-type punch. Friction tests were conducted by using a pin-on-disk type friction tester for an hour in PBS lubricated condition under the contact pressures of 0.5, 1 and 2 MPa with 50 mm distance per a cycle at ambient condition. As a result, coefficients of friction increased as the test duration increased for all contact pressures. The maximum coefficients of friction were 0.082, 0.06 and 0.098 for 0.5, 1, and 2 MPa, respectively. It showed that coefficients of friction of porcine knee joint cartilage against Co-Cr alloy depended on the level of contact pressure and related to squeeze film lubrication mechanism.