• 제목/요약/키워드: consumptions

검색결과 429건 처리시간 0.024초

고압산소요법시(高壓酸素療法時) 약물요법병행(藥物療法倂行)의 효과에 관(關)한 연구(硏究) (A study on the Effects of Hyperbaric Oxygenation Combined with the Drug Administration in the Treatment of CO poisoning)

  • 윤덕로;김익수
    • Journal of Preventive Medicine and Public Health
    • /
    • 제6권1호
    • /
    • pp.71-76
    • /
    • 1973
  • 1) The oxygen consumption was studied with albino rats under normal environment after they were given Cytochrome C intravenously (10mg/kg). The cosumption was 74.6cc/kg min. with that of control, 75.4cc/kg. min. The difference of the consumptions was not statistically significant. However, under 0.5% CO environment, the oxygen consumption of the Cytochrome C treated rats (62.5cc/kg min) was significantly greater than the control (42.1cc/kg min.) 2) The recovery time of rat acutely poisoned by 1% CO was studied. The recovery time of the Cytochrome C treated group was 37.2 minutes and in control group it was 52.2 minutes. Also significant difference of fatality was noted between the treated group (21.8%) and the untreated group (49.7%) 3) The combined effects of the hyperbaric oxygenation (100% $O_2$ at 3 atmospheric pressures) and the Cytochrome C administration was compared with the effect of the simple hyperbaric oxygenation. There was no significant difference of recovery time between the experimental group while the fatality of the experiment group was lower than control group.

  • PDF

THIRTEEN-WEEK REPEATED INTRAVENOUS TOXICITY STUDY OF A NEW ANTICANCER AGENT, SB IN BEAGLE DOGS

  • Jung, Eun-Yong;Lee, Soo-Hae;Zhang, Hu-Song;Huang, Zai-Zhi;Sin, Ji-Soon;Zheng, Mei-Shu;Kang, Min-Joung;Roh, Kyoung-Ok;Kim, Dae-Joong;Nam, Sang-Yoon;Kang, Jong-Koo
    • 한국독성학회:학술대회논문집
    • /
    • 한국독성학회 2001년도 International Symposium on Dietary and Medicinal Antimutgens and Anticarcinogens
    • /
    • pp.170-170
    • /
    • 2001
  • This study was designed to evaluate a repeated intravenous dose toxicity of a new anticancer agent, SB extracted from Pulsatilla korean Nakai in Beagle dogs. Animals were intravenously injected with dosages of 0, 0.062, 0.25, and 1 mg/kg of SB everyday for 13 weeks, respectively. There were no dose-related changes in clinical signs, body weight changes, food and water consumptions, opthalmoscopy, and urine analysis. There were somewhat significant differences compared with control group in organ weight, biochemical examination, and hematology findings of animals treated with SB. However, these changes were not dose-related changes. Gross and histopathological findings revealed no evidence of specific toxicity related to SB. These indicate that intraveous maximum tolerated dose value of SB may be over 1mg/kg in rats.

  • PDF

A Relay Selection and Power Allocation Scheme for Cooperative Wireless Sensor Networks

  • Qian, Mujun;Liu, Chen;Fu, Youhua;Zhu, Weiping
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제8권4호
    • /
    • pp.1390-1405
    • /
    • 2014
  • This paper investigates optimal relay selection and power allocation under an aggregate power constraint for cooperative wireless sensor networks assisted by amplify-and-forward relay nodes. By considering both transmission power and circuit power consumptions, the received signal-to-noise ratio (SNR) at the destination node is calculated, based on which, a relay selection and power allocation scheme is developed. The core idea is to adaptively adjust the selected relays and their transmission power to maximize the received SNR according to the channel state information. The proposed scheme is derived by recasting the optimization problem into a three-layered problem-determining the number of relays to be activated, selecting the active relays, and performing power allocation among the selected relays. Monte Carlo simulation results demonstrate that the proposed scheme provides a higher received SNR and a lower bit error rate as compared to the average power allocation scheme.

농작업자 자동 추종 운반차 개발(II) - 주행제어시스템 보완 및 포장성능시험 - (Development of an Autonomous Worker-Following Transport Vehicle ( II ) - Supplementation of driving control system and field experiment -)

  • 권기영;정성림;강창호;손재룡;한길수;정석현;장익주
    • Journal of Biosystems Engineering
    • /
    • 제27권5호
    • /
    • pp.417-424
    • /
    • 2002
  • This study was conducted to develop a vehicle, leading or following a worker at a certain distance to assist laborious transporting works in greenhouses. A prototype vehicle was tested in the practical field conditions using a developed control algorithm. Results of this study were summarized as following: 1. The sensing device consisted of infrared sensors was attached to the front of the vehicle and turning following algorithm was developed to make the vehicle turned as it follows a worker simultaneously. 2. The measured average power consumptions were 110W and 89W, equivalent to 5.2-6.4 hrs battery durations, at low speed with and without the maximum payload, respectively. 3. Results of the travel tests showed that the deviations from the center of row spacing were $\pm$100 mm along the ridge and $\pm$85 mm along the hydroponic bed in the greenhouse. Therefore, the worker-following transport vehicle was feasible to travel along the row without collision in the greenhouse.

승용 디젤 엔진에서 분사 전략이 배출 가스 및 엔진 성능에 미치는 영향에 관한 연구 (Effect of Injection Strategy on the Exhaust Emission and Performance Characteristics of a Light-duty Diesel Engine)

  • 노현구;이두진;이창식
    • 한국자동차공학회논문집
    • /
    • 제19권3호
    • /
    • pp.99-105
    • /
    • 2011
  • This paper described the effect of the multiple injections on the emission characteristics and combustion stability in a common rail diesel engine. In order to investigate the influence of multiple injections in a passenger car diesel engine, the injection strategy was varied with pilot injection, post injection and one main injection at various conditions. Based on the experimental results, the combustion and emissions characteristics were analyzed for the various injection strategies such as main, pilot-main, double-pilot-main, double- pilot-main-post injection strategy. It is revealed that the $NO_X$, HC and CO emissions are reduced by double pilot and post injection at medium load, however, soot emission is increased. Also, in the case of multiple injection, the combustion pressure is increased smoothly near the TDC and the coefficient of variation and fuel consumptions are decreased.

지역난방 공동주택의 건축물 에너지절약 설계기준 강화에 따른 난방에너지 사용량 분석 (Analysis of Heating Energy Consumption of District Heated Apartment with respect to Reinforcement of Building Energy-saving Design Criteria)

  • 이성우;정광섭;김영일
    • 한국지열·수열에너지학회논문집
    • /
    • 제7권2호
    • /
    • pp.16-22
    • /
    • 2011
  • Since 1970s, energy-saving design criteria of buildings has been improved through numerous revisions. The purpose of this research is to show how energy saving design criteria affects heating energy consumption of apartments using district heating. Heating energy consumption has been measured in 4 apartments located in Gyeonggi province, Korea from Nov. 1,2007 through Oct. 31, 2008. Collected data was regressed to linear correlations. Heating energy consumptions were calculated for past, present and future energy-saving design criteria, which are outdoor temperature, ventilation and insulation. The results show that present design criteria has reduced heating energy consumption by 15%, and the future criteria will reduce the energy consumption by 42% compared to the criteria before 2001.

다항함수를 이용한 건물의 연간부하 예측 방법에 관한 연구 (Study on the Annual Building Load Predicting Method using a Polynomial Function)

  • 윤희원;최승혁;류형규
    • 한국지열·수열에너지학회논문집
    • /
    • 제13권1호
    • /
    • pp.7-13
    • /
    • 2017
  • In order to use and manage the building energy efficiently, it is necessary to minimize building energy consumptions, and establish operation plans of various equipment. The maximum heating and cooling load calculation is an essential way in various equipment selections, and the annual building load calculation is used in forecasting & evaluating the LCC required for operation plan. In this study, noting that the annual building load changes depending on outside temperature around year, we propose a predicting method of annual building load. By using the $4^{th}$ polynomial function that have two double radix and a feature the $f(x)=a^4$ in x = 0 condition, we can calculate annual building load very easily only with the two result (maximum heating and cooling load) and a minimum parameters.

멀티 프로세서 임베디드 시스템에서 여유시간 예측에 의한 저전력 태스크 스케줄링 (An Energy-Efficient Task Scheduling Algorithm for Multi Processor Embedded System by Laxity Estimation)

  • 서범식;황선영
    • 한국통신학회논문지
    • /
    • 제35권11B호
    • /
    • pp.1631-1639
    • /
    • 2010
  • 본 논문은 멀티프로세서 임베디드 시스템에서 사용하는 어플리케이션을 구성하는 태스크를 수행하는데 필요한 전력과 태스크간의 의존성에 의해서 발생하는 통신 비용을 감소시킬 수 있는 스케줄링 알고리듬을 제안한다. 제안된 알고리듬은 기존 알고리듬에서는 통신비용은 고려하였으나 스케줄링 단계에서는 동적 전력 관리 결과를 고려하지 않는 점을 보완하여 스케줄링 단계에서 여유시간(Laxity) 사용을 예측하여 동적 전압 관리의 효율을 높이는 방법을 사용한다. 이를 통해 복잡한 멀티미디어 어플리케이션에 동적 전력 관리를 적용하여 수행 시 에너지 효율을 높였다. 실험 결과 멀티미디어 어플리케이션인 HD MPEG4, MotionJPEG codec, MP3, Wavelet 프로그램을 멀티프로세서 환경에서 제안된 알고리듬을 이용하여 저전력 스케줄링 결과 기존 방식에 비해 평균 11.2%의 에너지 감소를 얻었다.

폴리아미드 6의 열 산화반응에 의한 황변 현상과 산화방지제의 효과 (Discoloration and the Effect of Antioxidants on Thermo-Oxidative Degradation of Polyamide 6)

  • 허민호;김상우;하기룡;;홍기헌
    • 폴리머
    • /
    • 제26권4호
    • /
    • pp.452-461
    • /
    • 2002
  • 본 연구에서는 폴리아미드 6 (PA 6)을 70~$160^{\circ}C$에서 장시간 사용하였을 때 산화방지제의 사용유무 및 농도에 따른 열 안정성을 조사하였다. 70~$160^{\circ}C$의 온도범위내의 열 산화반응 시 모든 시료는 100시간 내에 황변 현상이 일어났다. 기계적 물성, 황변 지수, 점도측정으로 가장 적정한 산화방지제의 농도를 조사하였다. 일, 이차 산화방지제의 조성변화에 의한 산화방지효과는 미미하였다. 황변 현상의 분석은 NMR, IR, 그리고 element analysis (EA)를 사용하였다. $^{13}C$ NMR에 의해 서로 다른 카르보닐기의 존재를 확인하였으며, 산소의 소모량 측정은 EA를 사용하였다. Arrhenius식을 이용하여 산화방지제를 첨가한 시료와 그렇지 않은 시료의 lifetime을 예측하였다.

연면방전에 의한 질소산화물의 분해시 전극 공정변수에 대한 영향 (Effect of Electrode Process Variables in case of Decomposition of $NO_{x}$ by SPCP)

  • 안형환;강현춘
    • 대한안전경영과학회지
    • /
    • 제1권1호
    • /
    • pp.241-258
    • /
    • 1999
  • For hazardous air pollutants(HAP) such as NO and $NO_{2}$ decomposition efficiency, power consumption, and applied voltage were investigated by SPCP(surface induced discharge plasma chemical processing) reactor to obtain optimum process variables and maximum decomposition efficiencies. Decomposition efficiency of HAP with various electric frequencies(5~50 kHz), flow rates(100~1,000 mL/min), initial concentrations(100~1,000 ppm), electrode materials(W, Cu, Al), electrode thickness(1, 2, 3 mm) and number of electrode windings(7, 9, 11) were measured. Experimental results showed that for the frequency of 10 kHz, the highest decomposition efficiency of 94.3 % for NO and 84.7 % for $NO_{2}$ were observed at the power consumptions of 19.8 and 20W respectively and that decomposition efficiency decreased with increasing frequency above 20 kHz. Decomposition efficiency was increased with increasing residence times and with decreasing initial concentration of pollutants. Decomposition efficiency was increased with increasing thickness of discharge electrode and the highest decomposition efficiency was obtained for the electrode diameter of 3 mm in this experiment. As the electrode material, decomposition efficiency was in order : tungsten(W), copper(Cu), aluminum(Al).

  • PDF