A 10-bit 10MS/s differential straightforward SAR ADC

  • Rikan, Behnam Samadpoor;Abbasizadeh, Hamed;Lee, Dong-Soo;Lee, Kang-Yoon
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.4 no.3
    • /
    • pp.183-188
    • /
    • 2015
  • A 10-bit 10MS/s low power consumption successive approximation register (SAR) analog-to-digital converter (ADC) using a straightforward capacitive digital-to-analog converter (DAC) is presented in this paper. In the proposed capacitive DAC, switching is always straightforward, and its value is half of the peak-to-peak voltage in each step. Also the most significant bit (MSB) is decided without any switching power consumption. The application of the straightforward switching causes lower power consumption in the structure. The input is sampled at the bottom plate of the capacitor digital-to-analog converter (CDAC) as it provides better linearity and a higher effective number of bits. The comparator applies adaptive power control, which reduces the overall power consumption. The differential prototype SAR ADC was implemented with $0.18{\mu}m$ complementary metal-oxide semiconductor (CMOS) technology and achieves an effective number of bits (ENOB) of 9.49 at a sampling frequency of 10MS/s. The structure consumes 0.522mW from a 1.8V supply. Signal to noise-plus-distortion ratio (SNDR) and spurious free dynamic range (SFDR) are 59.5 dB and 67.1 dB and the figure of merit (FOM) is 95 fJ/conversion-step.

Study on the Reduction of Energy Consumption in the Pulsed Corona Discharge Process for NOx Removal (질소산화물 제거를 위한 펄스코로나 방전공정의 에너지 소모 저감에 관한 연구)

  • 정재우;손병학;조무현;목영선;남궁원
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.4
    • /
    • pp.475-483
    • /
    • 1999
  • A lab-scale test was carried out to study the reduction of electrical energy consumption in the pulsed corona discharge process for nitrogen oxides removal. The experiment was mainly focused on 1) the activation of pollution removal reactions by chemical additives and 2) the optimization of electrical circuit for the efficient energy transfer from the power supply to the corona reactor. Hydrocarbon chemical additives used in the experiment are thought to be responsible for the enhancement of the NO conversion through the chain reactions of free radicals such as, R, RCO, and RO. Electrical energy consumption per converted NO molecule has a minimum value of 17 eV when pentanol is injected. When ethylene and propylene are injected, 30 eV and 22 eV of electrical energy consumption is required for the conversion of NO molecule respectively. The ratio of the pulse forming capacitance$(C_e)$ to the reactor capacitance$(C_R)$ plays an important role in the energy transfer efficiency to the reactor. Maximum energy transfer efficiency of approximately 72% could be obtained by using the pulse forming capacitance which is 3.4 times larger than the reactor capacitance, and also the maximum NO conversion efficiency was observed with the same condition.

  • PDF

Chronic Alcohol Consumption Induced Tibial Bone Loss and Resulted in Osteopenia in Growing Young Male Rats

  • Kwak Chung Shil;Song Kye Yong;Park Sang Chul
    • Nutritional Sciences
    • /
    • v.8 no.2
    • /
    • pp.89-96
    • /
    • 2005
  • To determine the deleterious effects of chronic alcohol consumption on bone especially in adolescents or young adults, 8 week-old Sprague Dawley male rats were fed with Lieber-Decarli ethanol liquid diet, containing $36\%$ of energy as ethanol, ad libitum (ethanol group) or isocaloric normal liquid diet (control group) for 7 weeks. Body weight was significantly lower in ethanol group than that in control group after 1 week of feeding to the end. liver weight and the ratio of liver or kidney weight to body weight in ethanol group were significantly increased when compared to those in control group. Ethanol group showed significantly lower serum protein and albumin levels (p<0.05), higher total cholesterol and HDL-cholesterol levels (p<0.05), and AST, ALT and BUN activities than control group, but serum triglyceride, Ca and phosphate levels were not different. Ethanol group had significantly lower tibial trabecular bone area and serum osteocalcin level than control group (p<0.05), but urinary Ca and NTx (cross-linked N-telopeptide of type I collagen) concentrations and serum testosterone and parathyroid hormone levels were not different. In conclusion, chronic alcohol consumption in growing young male rats may result in osteopenia through the reduction of bone formation as well as liver malfunction.

Current compensation for material consumption of cobalt self-powered neutron detector

  • Liu, Xinxin;Wang, Zhongwei;Zhang, Qingmin;Deng, Bangjie;Niu, Yaobin
    • Nuclear Engineering and Technology
    • /
    • v.52 no.4
    • /
    • pp.863-868
    • /
    • 2020
  • Co Self-Powered Neutron Detector (SPND) is confronted with the problem of material consumption, which causes the response current can neither reflect the change of neutron flux in time nor be proportional to the neutron flux. In this paper, a deconvolution-based method is established to solve this problem. First of all, a step signal of neutron flux is taken as an example to analyze its performance. When the material consumption of Co SPND is 10%, after compensation, the response current can be in correspondence of neutron flux. Finally, the effects of this model in different Signal-to-Noise Ratio are analyzed, which fully confirms the truth of its excellent performance for compensating Co SPND's signal.

An Analysis on the Household Characteristics and Economic Status of Deficit Households (적자가계의 특성 및 경제구조 분석)

  • Yang, Se-Jeong
    • Journal of Family Resource Management and Policy Review
    • /
    • v.14 no.1
    • /
    • pp.135-159
    • /
    • 2010
  • The purpose of the study was to investigate the characteristics and economic status of deficit households compared to surplus households. Data from The Household Income and Expenditure Survey 2005 by NSO and 50, 207 salary/wage earners' households were used for the analysis. The statistical methods used were GLM, logit, and cluster analyses. The analysis results showed that 25.3 percent of the households were deficit households. Approximately half of the lowest 20% income group were deficit households. Income deficit households earned 1, 273 thousand less than that of surplus households, whereas consumption of deficit households was 1, 006 thousand more than that of surplus households. The average propensity of consumption of deficit households was 142.1. According to the logit analysis, factors contributing to the probability of belonging to a deficit household included income level, household size, age and educational level, occupation, homeownership, car ownership, and wife's employment status. Deficit households were classified into 5 types: 1) health care expenditure-dominated group, 2) housing expenditure-dominated group, 3) education expenditure-dominated group, 4) money transfer-dominated group, and 5) overall-overconsumption group. The overall-overconsumption group was the largest group of all at 58.5%. It was found that for all five groups, the changes in household size, income group, home ownership, and occupation of the individual were variables that influenced the probability of belonging to a certain group.

  • PDF

A Study on the Energy Consumption of Elementary Schools in Daejeon Metropolitan City (대전광역시 초등학교의 에너지 사용에 관한 조사연구)

  • Lee, Sang Hyeok;Park, Seung Ik
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.14 no.1
    • /
    • pp.8-15
    • /
    • 2018
  • The purpose of this study was to analyze the energy consumption according to the HVAC systems in 122 elementary schools. To do this, we classified schools according to the HVAC systems. Selected schools were classified to the following groups by the HVAC equipments: EHP, EHP and GHP together and GHP. In addition we divided schools by the number of classes. The main results are as follow: 1) Annual average energy consumption at schools was about 300~900(kWh/students), $30{\sim}50(kWh/m^2)$, 9,000~29,000((kWh/class) 2) The smaller schools, the higher the energy consumption per class; energy usage of 10~19 classes's schools were approximately 3 times higher than 40 classes's schools. 3) Schools where the EHP was installed had the lowest energy costs and energy usage. The difference in energy costs was lower than the difference in energy usage because of the fuel price and the ratio of energy sources.

Performance Evaluation of Job Scheduling Techniques Incorporating the Ondemand Governor Policy (온디맨드 거버너 정책에 따른 작업 스케줄링 기법의 성능 평가)

  • Tak, Sungwoo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.9
    • /
    • pp.2213-2221
    • /
    • 2015
  • The ondemand governor used in android-based smartphone platforms is a CPU frequency scaling technique. The ondemand governor sets the CPU operating frequency depending on the CPU utilization rate. Job scheduling affects the CPU utilization rate. The power consumption is proportional to the value of operating frequency. Consequently, CPU frequency scaling and CPU utilization rate have an effect on power consumption in a smartphone. In this paper, we evaluated the performance of job scheduling techniques incorporating the ondemand governor in terms of CPU utilization, power consumption, and job deadline miss ratio.

Study on the Exhaust Heat Recovery Equipment in a Factory - On the Performance of a U-shape Multitube Heat Exchanger - (공장폐열(工場廢熱) 회수장치(回收裝置)에 관한 연구(硏究) -U자형(字型) 다관식(多管式) 열교환기(熱交換機)의 성능(性能)에 관하여-)

  • Kim, Yung Bok;Song, Hyun Kap
    • Journal of Biosystems Engineering
    • /
    • v.8 no.2
    • /
    • pp.49-61
    • /
    • 1983
  • U shape multitube heat exchanger was equipped in the flue to recover the exhaust heat from the boiler system. The fluids of the exhaust heat recovery equipment were the flue gas as the hot fluid, and the water as the cold fluid. The flow geometry of the fluids was cross flow - two pass, the hot fluid being mixed and the cold fluid unmixed. The results of the theoretical and the experimental analysis and the economic evaluation are summarized as follows. 1) The heat exchanger effectiveness and the temperature efficiency of the hot fluid were about 35% when the fuel consumption rate was 140 - 150 L/15min. The temperature efficiency for the cold fluid ranged from 3.0% to 4.5%. The insulation efficiency ranged from 85% to 98%, which was better than the KS air preheater insulation efficiency of 90%. 2) The relationship between the fuel consumption rate, F, and the outlet temperature, $T_{h2}$, of the flue gas from the heat exchanger was $T_{h2}$ = 0.927F + 110. In order to prevent the low temperature corrosion from the coagulation of $SO_3$, it is necessary to maintain the fuel consumption rate above 82 L/15min. 3) The ratio of the exhaust heat from the boiler system to the total energy consumption was about 14.5%. With the installation of the exhaust heat recovery equipment, the energy recovery ratio to the exhaust heat was about 25%. Accordingly, about 3.6% of the total fuel consumption was estimated to be saved. 4) Economic analysis indicated that the installation of the exhaust heat recovery equipment was feasible to save the energy, because the capital reocvery period was only 10 months when the fuel consumption rate was 80 L/15min. 4 months when it was 160 L/15min. 5) Based on the theoretical and the experimental analysis, it was estimated to save the energy of about 18 million Won per year, if four heat exchangers are installed in a factory. 6) A further study is recommended to identify the relationship among the flow rate of the exhaust gas, the size of the heat exchanger and the capacity of the air preheater. For a maximum heat recovery from the exhaust gas an automatic control system is required to control the flow rate of the cold fluid depending on the boiler load.

  • PDF

A Study on Moisture Transport of Artificial Lightweight Concrete (인공경량골재 콘크리트의 수분이동 특성에 관한 연구)

  • Lee, Chang Soo;Choi, Sang Hyun;Park, Jong Hyok;Kim, Young Ook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.4A
    • /
    • pp.373-384
    • /
    • 2009
  • For the first step on the quantitative evaluation of shrinkage reduction and differential shrinkage analysis of lightweight aggregate concrete, this study sets the moisture transport model of concrete by pre-absorbed water of porous lightweight aggregates and measured effective moisture diffusion coefficient, moisture capacity, degree of humidity supply and degree of humidity consumption by water binder ratio and aggregate type. The effective moisture diffusion coefficient in steady state caused by humidity difference between inside and outside of concrete had low value as low water-binder ratio. And in case of same water-binder ratio, effective moisture diffusion of mixtures used normal aggregates were lower than those used lightweight aggregates. To determine moisture store capability of concrete - moisture capacity, moisture contents were measured in 9 humidity conditions. As a result moisture contents of mixtures used lightweight aggregates was higher than mixtures used normal aggregates in all humidity conditions. This study measured lightweight aggregates' degree of humidity supply that applicable to normal atmospheric environment (above RH 50%) and made it quantitatively. Also amount of moisture release was set as a exponential function that represents a clear trend proportion to time and inverse proportion to humidity of the surroundings. As the result of measurement about degree of moisture consumption inside concrete following the internal consumption caused by cement hydration self-drying, it was showed that rapid decrease of humidity, around 10%, at early ages (7~10 days) when water-binder ratio is 0.3 and slow decrease around 5% and 1% when water-binder ratio is 0.4 and 0.5.

A Study on the Flow Characteristics and Engine Performance with Swirl Ratio Variance of Intake Port (흡기포트 선회비 변경에 따른 유동특성 및 엔진성능에 관한 연구)

  • Yoon, Jun-Kyu;Cha, Kyung-Ok
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.899-905
    • /
    • 2000
  • The characteristics of air flow and engine performance with swirl ratio variance of intake port In a turbocharged DI diesel engine was studied in this paper. The intake port flow is important factor which have influence on the engine performance and exhaust emission because the properties in the injected fuel depend on the combustion characteristics. The swirl ratio for ports was modified by hand-working and measured by impulse swirl meter. For the effects on performance and emission, the brake torque and brake specific fuel consumption were measured by engine dynamometer and NOx, smoke were measured by gas analyzer and smoke meter. As a result of steady flow test, when the valve eccentricity ratio are closed to cylinder wall, the flow coefficient and swirl intensity are increased. And as the swirl ratio is increased, the mean flow coefficient is decreasing, whereas the gulf factor is increasing. Also, through engine test its can be expected to meet performance and emission by optimizing the main parameters; the swirl ratio of intake port, injection timing and compression ratio.