• 제목/요약/키워드: construction loads

Search Result 1,135, Processing Time 0.025 seconds

Surface Cover Effect for Reducing Nitrogen Load in Organic Farming Fields using APEX Model (APEX 모형을 이용한 유기농경지에서의 질소 부하량 저감을 위한 지표피복 효과)

  • So, Hyunchul;Jang, Taeil;Kim, Dong-Hyeon;Seol, Dong-Mun;Yoon, Kwangsik
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.60 no.5
    • /
    • pp.55-67
    • /
    • 2018
  • The objectives of this study were to monitor organic farming upland compared with conventional upland field and to evaluate nutrient loads reduction of surface cover effect with long-term historical climate data. APEX(Agricultural Policy Environmental eXtender) model was validated with experimental data and used for assessing surface cover scenarios for 30-year simulation periods. The validated values of RMSE(Root Mean Square Error), RMAE(Root Mean Absolute Error), $R^2$ and E(Nash-Sutcliffe efficiency) for runoff were 1.17-1.37 mm/day, 0.28-0.45 mm/day, 0.88-0.90 and 0.82-0.94 in two treatments, respectively. Those for water quality (nitrogen) were 0.05-0.16 kg/ha, 0.52-0.75 kg/ha, 0.67-0.72 and 0.32-0.70 in two treatments, respectively, and therefore the validated model showed good agreement with the observed runoff and nitrogen load for the study period. When decreasing the surface cover rate of organic farming field to 75%, 50%, 25%, and 0% (conventional field), average annual runoff increased by 7%, 15%, 23% and 31%, respectively. Under same condition of decreasing the surface cover rate, average annual nitrogen loads increased by 1.4 times, 1.7 times, 2.0 times, and 2.3 times compared with organic farming field, respectively. This study showed that it is possible to present an appropriate surface cover ratio to maintain conventional production and minimize nonpoint sources pollution for organic farming system, although long-term monitoring is needed to determine its effects on environmental concerns, crop competition, and other uncertainty.

A Study on the Stability of Embankment Due to the Construction of Embankment Combined Use Road (제방겸용도로 건설에 따른 제방 안정성 해석에 관한 연구)

  • Kim, Sung-Nam;Lee, Young-Woo
    • International Journal of Highway Engineering
    • /
    • v.10 no.3
    • /
    • pp.109-118
    • /
    • 2008
  • This study analyzes the change of stability of embankment due to the construction of embankment combined used road with two different construction phases. The stabilities have been checked both in the phase of earth banking for a road construction and in the phase of the application of the traffic roads(DB-24). In both cases the factor of safety has been found higher than 1.3 which is the general criterion of the safety of an embankment. The results indicate that the safety of an embankment due to the construction of embankment combined use road is assured, and thus, it is thought that the construction of embankment combined use road can be considered for cutting down on expenses of construction sites for a road construction. However, the pre-examination of stability due to the construction should be carried out because it decreases the factor of safety of an embankment. From this study, it has been found that the factor of safety was dropped most when the water level rose in the transient flow. The result indicates that the stability analysis of a river embankment where the water level changes frequently should be carried out in the condition of transient flow. It is recommended that the inner side of an embankment should have a slope of 1:2 which is identical with the slope of the existing embankment. In addition, the factor of safety also can be decreased due to the traffic loads, and therefore, the effect should also be considered after the construction of embankment combined used road limiting the traffic loads.

  • PDF

Temporary Stabilizing Measures during Construction of a Steel Composite 2-Edge Girder Cable Stayed Bridge (강합성 2주형 사장교의 시공중 내풍 안정성 확보 방안 연구)

  • Kim, Young-Min;Kim, Dae-Young
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.63-66
    • /
    • 2008
  • The bridge deck section composed of a concrete slab resting on two I-beam girders are known to be susceptible to flutter instability and vortex shedding. Moreover, the cable stayed bridge in construction is more vulnerable to wind rather than in service when the free cantilever construction method is applied. This paper describes the effect of the dynamic wind loads on the bridge during construction and the effect of alternative temporary stabilizing measures. Therefore, a series of wind tunnel tests and numerical analysis were carried out to determine if any countermeasures were required.

  • PDF

Examination of the effects on earthquake behavior and rough construction costs of short column situation occurring in reinforced concrete buildings

  • Gursoy, Senol;Cavusoglu, Aykut
    • Earthquakes and Structures
    • /
    • v.20 no.3
    • /
    • pp.309-323
    • /
    • 2021
  • Architectural design decisions and structural systems arrangements affect their earthquake behaviors significantly of reinforced concrete building in Turkey. Because the performances as safe and economical against earthquake loads of reinforced concrete buildings can be provided with especially design decisions in the architectural design stage. This matter reveals the importance of design decisions in the architectural design phase and the right structural system arrangement. The purpose of this study, the short-column situation frequently observed in reinforced concrete buildings after the earthquakes occurred in Turkey are to examine comparatively the effects on behavior and the rough construction cost of the building. The obtained results show that the short column circumstance composed due to different reasons negatively affects the earthquake performance of the reinforced concrete buildings and increases the rough construction cost. This matter shows that the measures to be taken against short column formation should be foreseen especially at the architectural design stage.

An Experimental Study on the Behavior of the T-type Steel Composite Beam (단순지지 T형 합성보의 휨거동에 관한 실험적 연구)

  • Kim, Sang Seup;Kim, Sang Mo;Kim, Sung Bae;Seo, Dong Gee;Kim, Kyu Suk
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.2 s.69
    • /
    • pp.225-233
    • /
    • 2004
  • Composite action is generally achieved by providing shear connections between steel top flange and concrete topping. Composite sections have greater stiffness than the summation of the individual stiffness of slab and beam. Therefore, they can carry larger loads or similar loads with appreciably smaller deflection and are less prone to transient vibration. T-type Steel Composite beam (TSC-beam) was developed to increase these advantages. Ten specimens were tested for this study. During the experiment, crack pattern and deflection of beam were investigated. The examined results of TSC beam system were compared with results from the typical composite beam and RC beam.

Analysis of Electric Power Effect of Piezoelectric Element on Steel-concrete Composite Bridge (강합성 교량에 설치된 압전소자의 전력발생효과 분석)

  • Kim, Sang-Hyo;Jung, Chi-Young;Chung, Ha-Min;Ahn, Jin-Hee
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.5
    • /
    • pp.411-420
    • /
    • 2010
  • In general, moving vehicles generate continuous and repetitive strain of energy on bridges. The strain energy can convert to electric energy due to its piezoelectric element. However, some factors should be considered in order to reasonably assess the feasibility such as load distribution applied on bridges and the relationship of strains generated according to loads. This study was carried out to estimate the generated voltage when piezoelectric elements were installed to a bridge. A steel-concrete composite specimen was fabricated and loads were applied, considering vehicle load-effects. As a result, the voltage generated in the element was evaluated and compared with the analysis equation of the piezoelectric effect.

A Study on the Tolerance Band of Voltage Drop during Motor Startup for Refineries and Chemical Plants with Isolated Power Systems

  • Shin, Ho-Jeon;Cho, Man-Young;Chun, Hong-Il;Kim, Jin-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.486-493
    • /
    • 2017
  • Refineries and chemical plants with isolated power systems that have a limited power supply are more susceptible to voltage changes from disturbances compared to power systems connected with a power company. Furthermore, most loads in such cases are induction motor loads, and therefore, transient voltage characteristics when starting a high-capacity motor must be examined. In general, high-capacity motors are customized appropriately to the load performance curve by the manufacturer during the construction of an industrial plant. Subsequently, when complying with the voltage drop permitted by international standards during the design process, power supply equipment such as transformers and generators is overdesigned. Therefore, a novel analysis is necessary on standards for startup and constraint voltage drops, as well as on identifying the voltage drop limitations for starting high-capacity motors in refineries and chemical plants with isolated power systems. In this study, field tests on an industrial plant were conducted, and simulations modeled under conditions identical to those of the field test system were performed using the general-purpose program ETAP in order to compare the results.

The elastic bucking strength of axially compressed tubular member with through-gusset connection (관통한 가셋트판이 부착된 압축 강관 부재의 탄성좌굴내력)

  • Kim, Woo-Bum;Lim, Ji-Youn
    • Journal of Korean Society of Steel Construction
    • /
    • v.13 no.2
    • /
    • pp.133-141
    • /
    • 2001
  • A tubular member holding an axially through-gusset connection is often used to transmit axial compression in a steel truss structures. The elastic buckling loads of the member is affected by the stiffness ratio($\beta$) and the length ratio(G) because of two elements with different properties. In current code, however, the strength is evaluated with an effective length factor k=0.9 without considering the above effect. Therefore this study analyzed a theoretical mechanism based on the elasticity theory and performed a finite element analysis to investigate the influence parameters on the elastic buckling strength of axially loaded member.

  • PDF

Stability and minimum bracing for stepped columns with semirigid connections: Classical elastic approach

  • Aristizabal-Ochoa, J. Dario
    • Structural Engineering and Mechanics
    • /
    • v.5 no.4
    • /
    • pp.415-431
    • /
    • 1997
  • Stability equations that evaluate the elastic critical axial load of stepped columns under extreme and intermediate concentrated axial loads in any type of construction with sidesway totally inhibited, partially inhibited and uninhibited are derived in a classical manner. These equations can be utilized in the stability analysis of framed structures (totally braced, partially braced, and unbraced) with stepped columns with rigid, semirigid, and simple connetions. The proposed column classification and the corresponding stability equations overcome the limitations of current methods which are based on a classification of braced and unbraced columns. The proposed stability equations include the effects of: 1) semirigid connections; 2) step variation in the column cross section at the point of application of the intermediate axial load; and 3) lateral and rotational restraints at the intermediate connection and at the column ends. The proposed method consists in determining the eigenvalue of a $2{\times}2$ matrix for a braced column at the two ends and of a $3{\times}3$ matrix for a partially braced or unbraced column. The stability analysis can be carried out directly with the help of a pocket calculator. The proposed method is general and can be extended to multi-stepped columns. Various examples are include to demonstrate the effectiveness of the proposed method and to verify that the calculated results are exact. Definite minimum bracing criteria for single stepped columns is also presented.