• Title/Summary/Keyword: construction control

Search Result 5,207, Processing Time 0.035 seconds

Optimization of Design Parameters of a EPPR Valve Solenoid using Artificial Neural Network (인공 신경회로망을 이용한 전자비례 감압밸브의 솔레노이드 형상 최적화)

  • Yoon, Ju Ho;Nguyen, Minh Nhat;Lee, Hyun Su;Youn, Jang Won;Kim, Dang Ju;Lee, Dong Won;Ahn, Kyoung Kwan
    • Journal of Drive and Control
    • /
    • v.13 no.2
    • /
    • pp.34-41
    • /
    • 2016
  • Unlike the commonly used On/Off solenoid, constant attraction force which is independent of plunger displacement is a considerably important characteristic to proportional solenoid of the EPPR Valve. Attraction force uniformity is mainly affected by the internal shape design parameters. Due to a number of shape design parameters, the optimal parameter values are very complex and time consuming to find by trial and error method. Much research has been conducted or are still in progress to find the optimal parameter values by applying various optimization techniques like Genetic Algorithm, Evolution Strategy, Simulated Annealing, or the Taguchi method. In this paper, the design parameters which have primary effects on the attraction force uniformity and the average attraction force are decided by main effects analysis of Design of Experiments. Optimal parameter values are derived using finite-element analysis and a neural network model.

Development of Performance Simulator for 6-speed DCT-based Hybrid Electric Vehicle to Evaluate the Fuel Economy (연비 평가를 위한 6속 DCT기반 HEV 성능 시뮬레이터의 개발)

  • Baek, J.J.;Lee, Y.K.;Park, J.H.;Han, K.S.;Hwang, S.H.
    • Journal of Drive and Control
    • /
    • v.10 no.4
    • /
    • pp.1-6
    • /
    • 2013
  • With aggravation of environmental contamination and energy resource exhaustion, Hybrid Electric Vehicles (HEV) that can be economically operated with low fuel consumption are receiving greater attention. For performance improvement of such HEV, the development of efficient transmission can be seen as one of core technologies such as performance of components and driving strategy. Dual clutch transmission (DCT) is actively studied as a transmission type for HEV due to its advantages of having excellent power transmission efficiency based on manual transmission characteristic, resolving the problem of power interruption, and realizing driving convenience of automatic transmission (AT). In this paper, one diesel HEV equipped with 6-Speed DCT, modelled using MATLAB/Simulink, and a performance simulator developed for this vehicle are introduced. Driving simulation with driving cycles such as FTP75 and NYCC was performed using the developed performance simulator, and the simulated results regarding state of charge and fuel economy, when AT and DCT are applied to this diesel hybrid vehicle respectively, are compared. This performance simulator can be utilized to develop a control algorithm for improving the fuel economy of HEV with DCT.

Numerical Simulation of Smoke Ventilation in Rescue Route and Cross Passage of Railroad Tunnel (철도터널 화재시 연결통로 및 대피로 제연을 위한 수치해석 연구)

  • Yang, Sung-Jin;Hur, Nahm-Keon;Ryou, Hong-Sun;Kim, Dong-Hyeon;Jang, Yong-Jun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.1
    • /
    • pp.1-10
    • /
    • 2008
  • A transient 3-D numerical simulation was performed to analyze the fire safety in a railway tunnel equipped with a mechanical ventilation system. The behavior of pollutants was studied for the emergency operation mode of ventilation system in case of fire in the center of the rescue station and near the escape route. Various schemes of escape route construction for connection angle($45^{\circ}$, $90^{\circ}$, 135^{\circ}$) and slope($10^{\circ}$) were evaluated for the ventilation efficiency in the fire near the escape route. From the results, it was shown that the mode of the ventilation fan operation which pressurizes the tunnel not under the fire and ventilates the smoke from the tunnel under the fire is most effective for the smoke control in the tunnel in case of the fire occurrence. It was also shown that the blowing of jet fan from the rescue tunnel to the main tunnel should be in the same direction as the flow direction in the main tunnel arising from the traffic and the buoyancy.

An Analysis of Mechanism of Auto-Sensing Breaker's Automatic Impact (지능형 브레이커의 자동타격 메카니즘 분석)

  • Park, Sung-Su;Noh, Dae-Kyung;Lee, Dae-Hee;Lee, Geun-Ho;Kang, Young-Ky;Cho, Jae-Sang;Jang, Joo-sup
    • Journal of the Korea Society for Simulation
    • /
    • v.25 no.4
    • /
    • pp.31-42
    • /
    • 2016
  • This study aims to identify the core technology for the automatic impact of the auto-sensing breaker that is one of the construction machinery which do not have a notable development success case yet in Korea. The study has been carried out as follows. Firstly, an analysis model was developed after determining the interconnection of pressure receiving area, opening area and port. And then, a simulation of situation that hard rock and soft rock are mixed was carried out to verify if it is possible to switch between long impact mode and short impact mode continuously. Lastly, the dynamic behavior of automatic control valve induced by the change of impact mode was analyzed based on the analysis result to decipher the core principle of automatic impact control.

The multi-axial testing system for earthquake engineering researches

  • Lin, Te-Hung;Chen, Pei-Ching;Lin, Ker-Chun
    • Earthquakes and Structures
    • /
    • v.13 no.2
    • /
    • pp.165-176
    • /
    • 2017
  • Multi-Axial Testing System (MATS) is a 6-DOF loading system located at National Center for Research on Earthquake Engineering (NCREE) in Taiwan for advanced seismic testing of structural components or sub-assemblages. MATS was designed and constructed for a large variety of structural testing, especially for the specimens that require to be subjected to vertical and longitudinal loading simultaneously, such as reinforced concrete columns and lead rubber bearings. Functionally, MATS consists of a high strength self-reacting frame, a rigid platen, and a large number of servo-hydraulic actuators. The high strength self-reacting frame is composed of two post-tensioned A-shape reinforced concrete frames interconnected by a steel-and-concrete composite cross beam and a reinforced concrete reacting base. The specimen can be anchored between the top cross beam and the bottom rigid platen within a 5-meter high and 3.25-meter wide clear space. In addition to the longitudinal horizontal actuators that can be installed for various configurations, a total number of 13 servo-hydraulic actuators are connected to the rigid platen. Degree-of-freedom control of the rigid platen can be achieved by driving these actuators commanded by a digital controller. The specification and information of MATS in detail are described in this paper, providing the users with a technical point of view on the design, application, and limitation of MATS. Finally, future potential application employing advanced experimental technology is also presented in this paper.

Improvement of Boiler Performance on 550 MW Coal Fired Thermal Power Plant via Baffle Plates (다공판 연소가스 유량제어를 통한 석탄화력발전소 보일러 성능 개선)

  • Kim, Chi Ho;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.17 no.1
    • /
    • pp.38-49
    • /
    • 2021
  • In order to increase power plant efficiency, the steam temperature was increased to 610 ℃ which deteriorates the durability of the boiler tube and as the use of low-calorie coal increases the post combustion and delayed combustion phenomenon, the overheating of the final reheater and the tube rupture are becoming frequent. In order to prevent overheating of the final reheater, desuperheater water injection was increased, leading to a decrease in boiler efficiency. In this study install a baffle plate at the back of some overheated tube groups, thereby reduce the temperature of the tube by reducing the amount of combustion gas, and the reduced combustion gas moves to an adjacent place to increase the temperature of other tubes. As a result of the study, the temperature deviation between tubes decreased 1.5. And the heat-reducing injection amount was reduced to 6,929 kg/h and the maximum tube temperature was reduced to 623.4℃ which is 6.6℃ more below than the control standard of 630℃.

Prediction of Internal Tube Bundle Failure in High Pressure Feedwater Heater for a Power Generation Boiler by the Operating Record Monitoring (운전기록 모니터링에 의한 발전보일러용 고압 급수가열기 내부 튜브의 파손예측)

  • Kim, Kyeong-seob;Yoo, Hoseon
    • Plant Journal
    • /
    • v.15 no.2
    • /
    • pp.56-61
    • /
    • 2019
  • In this study, the failure analysis of the internal tube occurred in the high pressure feedwater heater for power generation boiler of 500 MW supercritical pressure coal fired power plant was investigated. I suggested a prediction model that can diagnose internal tube failure by changing the position of level control valve on the shell side and the suction flow rate of the boiler feedwater pump. The suggested prediction model is demonstrated through additional cases of feedwater system unbalance. The simultaneous comparison of the shell side level control valve position and the suction flow rate of the boiler feedwater pump compared to the normal operating state value, even in the case of the high pressure feedwater heater for the power boiler, It can be a powerful prediction diagnosis.

Impacts of the Establishments' Safety Behavior, Safety and Health Delivery and Communication on Occupational Safety and Health Policy Satisfaction

  • Choi, Seo-Yeon;Jung, Han-Suk;Ham, Joo-Hyun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.8
    • /
    • pp.151-158
    • /
    • 2019
  • In this paper, we conducted a study to understand the impacts of safety behavior, safety and health delivery and communication, which should be managed for the establishments' safety and health control on occupational safety and health policy satisfaction to utilize that as a material for preparing policy support and preventive measures. For this purpose, we conducted a statistic analysis with 2,970 establishments, utilizing the material, "2015 Occupational Safety and Health Company Survey". As a result, in the manufacturing industry, it turned out in the establishments with more than 300 workers, safety behavior, safety and health delivery and communication of the cooperative firm of the prime contractor were high. In addition, it turned out that safety behaviors had the biggest impact on occupational safety and health policy satisfaction in the manufacturing industry and safety and health delivery and communication had the biggest impact on occupational safety and health policy satisfaction in the construction industry and other industries. As for the relationship between companies, it turned out that safety behaviors had the biggest impact on that between the parent company and a cooperative firm of a prime contractor while safety and health delivery and communication on that between the prime contractor and the subcontractor. Through the results of this study, it is necessary to build up safety and health behavior and safety and health delivery and communication systems for the characteristics of the company, and it is expected that the effect of the safety and health control will increase when policy support is made accordingly.

Shaking table tests on seismic response of backdrop metal ceilings

  • Zhou, Tie G.;Wei, Shuai S.;Zhao, Xiang;Ma, Le W.;Yuan, Yi M.;Luo, Zheng
    • Steel and Composite Structures
    • /
    • v.32 no.6
    • /
    • pp.807-819
    • /
    • 2019
  • In recent earthquakes, the failure of ceiling systems has been one of the most widely reported damage and the major cause of functionality interruption in some buildings. In an effort to mitigate this damage, some scholars have studied a series of ceiling systems including plaster ceilings and mineral wool ceilings. But few studies have involved the backdrop metal ceiling used in some important constructions with higher rigidity and frequency such as the main control area of nuclear power plants. Therefore, in order to evaluate its seismic performance, a full-scale backdrop metal ceiling system, including steel runners and metal panels, was designed, fabricated and installed in a steel frame in this study. And the backdrop metal ceiling system with two perimeter attachments variants was tested: (i) the ends of the runners were connected with the angle steel to form an effective lateral constraint around the backdrop metal ceiling, (ii) the perimeter attachments of the main runner were retained, but the perimeter attachments of the cross runner were removed. In the experiments, different damage of the backdrop metal ceiling system was observed in detail under various earthquakes. Results showed that the backdrop metal ceiling had good integrity and excellent seismic performance. And the perimeter attachments of the cross runner had an adverse effect on the seismic performance of the backdrop metal ceiling under earthquakes. Meanwhile, a series of seismic construction measures and several suggestions that need to be paid attention were proposed in the text so that the backdrop metal ceiling can be better applied in the main control area of nuclear power plants and other important engineering projects.

Development of PLC-based Fieldbus Educational Equipment and Curriculum for building Smart Factory (스마트팩토리 구축을 위한 PLC기반의 필드버스 교육 장비 및 교육과정 개발)

  • Oh, Jae-Jun;Choi, Seong-Joo
    • Journal of Practical Engineering Education
    • /
    • v.9 no.1
    • /
    • pp.49-56
    • /
    • 2017
  • Recently, due to Industry 4.0, there is a great interest in smart factory for productivity improvement and customer satisfaction in manufacturing industry, and construction is also actively pursued by government support. In particular, data integration and fieldbus communication technology to build an efficient production system are essential. Fieldbus is an open control system that is not tied to a specific vendor system and has various advantages such as compatibility with other products, accuracy of data transmission, and remote diagnosis. However, there are no educational equipment for training field buses, training courses and examples for practical training, and there are many limitations in improving the practical skills needed for building smart factories in the industrial field. Therefore, this study develops PLC based fieldbus education equipment and training course based on previous research results that selected PLC and communication technology suitable for domestic industry field for practical fieldbus training and develops the training program of Ethernet IP, Profibus DP, Modbus, CC-Link, and DeviceNet. In addition, it is confirmed that the control and remote diagnosis of distributed field devices are possible by data collection and monitoring.