• Title/Summary/Keyword: construction control

Search Result 5,209, Processing Time 0.03 seconds

Estimation of Plant Seed Dispersal through Artificial Soil Movement in Incheon Urban Area

  • Kim, Kee-Dae
    • Korean Journal of Environmental Biology
    • /
    • v.21 no.2
    • /
    • pp.181-188
    • /
    • 2003
  • In this study, soil seed and bud bank analysis were performed to abbess the mass of potential vegetation in soils less than 1 year old after covered and estimate the amount of seed bank transport through construction in urban area. The ratio of exotic species number to total species number in study sites and the landfill control site was 0.29 and 0.39, respectively. All plots pooled, mean species number and total mean seedling density per $\m^2$ in the top 10 cm of soil was 11$\pm$0 (average$\pm$S.E.) and 8037$\pm$221.Total plant seeds by artificial soil trasnsfer were estimated to be 53 thousand million $m^{-2}yr^{-1}$ in 10 cm soil depth. It reveals that soil transfer accelerates seeds and vegetation movement and makes urban vegetation mixed and common.

Vibration Analysis of Stiffened Thick Plate Subjected to Static Inplane Stress Using Finite Element Method (면내응력을 받는 보강 후판의 유한요소법에 의한 진동해석)

  • 오숙경;김일중;이용수
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.952-956
    • /
    • 2004
  • The soil-structure interactions are caused by the point sources of explosions, deriving piles, compaction of foundations and excavations those are frequently arose in the construction sites. Thus the analysis of soil-structure interactions is one of the most important subjects in the fields of dynamic analysis and vibration control. From this viewpoint, the aim of this study is to collect the basic data for designing foundation structures throughout understanding the dynamic structural behavior, which is embodied by the dynamic analysis of soil-structure systems. In this study, the dynamic analyses of stiffened thick plates subjected to in-plane stress on elastic foundations are carried out. The foundation is modeled as Pasternak foundation that includes the continuity effect of foundations. Also both the Mindlin plate theory and Timoshenko beam-column theory are used for analyzing the thick plates and beams, respectively.

  • PDF

A Development of Prediction Program for Vertical Transfer Vibration of R/C Structure due to Traffic Loads (교통하중에 인접한 콘크리트 건축물의 진동예측 프로그램 개발)

  • Chun, Ho-Min;Hong, Kap-Pyo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.949-954
    • /
    • 2000
  • In terms of vibration damage and the serviceability for occupants in buildings, the purpose of vibration study lies in the reduction of vibration damage. However, only when vibration level of buildings is available, measures of vibration control and base isolation can be taken. The purpose of this paper is to provide a fundamental analysis method to estimate structural vibration. After analysing by using two methods, infinite model, combination method, a comparison between analysed results and the results of previous studies was performed to prove the validity of the prediction on the vibration of building structure. Thus, if the material property of soil and quantity of load sources are known before construction being started, the vibration level could be predicted by using these methods.

  • PDF

Construction of HTS multi-channel SQUID system

  • Park, W.K.;Lee, H.J.;Moon, S.H.;Lim, S.H.;Kim, D.Y.;Oh, B.;Lee, S.M.
    • 한국초전도학회:학술대회논문집
    • /
    • v.10
    • /
    • pp.169-172
    • /
    • 2000
  • We have constructed a multi-channel SQUID magnetometer system. The system is designed to operate normally with 10 high temperature direct coupled SQUIDs. The main features of the system include a remote control by serial communication, low noise with wide bandwidth and high slew rate by several MHz modulation, signal conditioning and calibration by digital signal processing.

  • PDF

Production and Statistical Qualtity Control of Low-Heat High Strength Reacy-Mixed Concrete (저발열 고강도 레미콘 제조 및 통계적 품질관리)

  • Park, Yon-Dong;Noh, Jae-Ho;Han, Chung-Ho;Kim, Hoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.04a
    • /
    • pp.376-381
    • /
    • 1996
  • In this study, the quality contral of high strength reacy-mixed concrete with design compressive strength of 420 kgf/$\textrm{cm}^2$ placed at a tail building for a long period is statistically investigated. The amount of cast-in-place high strength concrete is by about $15000\textrm{m}^3$. The required average compressive striength is 500 kgf/$\textrm{cm}^2$ according to KS F 4009 with assumed coefficient of variation of 11%. Since there are many concrete members in this construction, fly ash is used to reduce the heat of hydration of concrete. As the results of this study, the average actual 28-day compressive strength is 498 kgf/$\textrm{cm}^2$ and the coefficient of variation is 6.7%. The placing speed is comparable to normal strength concrete, however, the pump pressure is higher than that of normal strength concrete.

  • PDF

An Experimental Study for Development and Application of High-Flow Concrete (고유동콘크리트 개발 및 실용화를 위한 실험적 연구 -거푸집 설계를 중심으로-)

  • 안상기;김상철;엄태용;최수홍;이두재
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.04a
    • /
    • pp.42-47
    • /
    • 1996
  • Due to high increase of labor charge and necessarity of better quality control on concrete, various studies have been carried out to improve a flowability of concrete without the use of mechanical vibrator. As a result of enthusiastic study, one can closely access to the development of high flowable concrete in a laboratorial view. Application to practical field, however, is still far as long as a regulation for construction is not properly specified. Based on the idea that lateral pressure measured from high flowable concrete will be larger than those from general typed concrete, we read a series of lateral pressure from mechanical pressure plate and compared those with the values calculated form specified formula.

  • PDF

A Study on the Long term Properties of Epoxy Resin (에폭시 제진의 장기적인 특성연구)

  • 한만엽;송병표;이원창;연규석
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.89-94
    • /
    • 1997
  • As the reinforced concrete structures are aged, repair and rehabilitation materials and techniques have ben developed. However, most of the repair materials and methods are imported from abroad and theoretical study and repairing techniques are also not well established yet. A specification for quality of repair materials should be established, in order to secure the stability and to improve the serviceability of the repaired structures. In this study, long term properties of repair materials such as thermal expansion coefficient, hardening shrinkage, creep, and chemical resistance have been tested. The material properties shows to be affected many actors such as curing period, temperatures, relative humidity, and etc. The repair material should be selected by considering the cause and shape of the defects, mix properties, workability, quality control of construction, and etc.

  • PDF

A Study on the Strength. Chemical Resistance and Absorption of Polymer concrete with Recycling PET (재활용 PET수지를 이용한 폴리머 콘크리트의 강도, 내화학성, 흡수율에 관한 실험적 연구)

  • 조병완;서석구;태기호;박승국;류성희
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.805-810
    • /
    • 2003
  • It is the real circumstance in the country that not only the data and special books but also people who have an expert knowledge are short of the field of the study about plastic wastes, so that to build the Database carrying out gathering info of that is the present question obviously. The business on recycling plastic, for some reason or other, is one of the best ways as called bright prospect industry to prevent environmental pollution and obtain economical outcome by using limited resources. Plastic wastes with construction industry especially using Polymer may have a good effect on the environment and human beings and have a fine view to produce functional and Eco-friendly concrete as well. In this study, Chemical resistance and Water Absorption test in Polymer concrete using bentonite as a shrinkage control agent was made an experiment by comparing with influence on concrete strength and used to offer some valuable data about Polymer concrete.

  • PDF

Bond characteristics by joint condition between old and. new concrete (신ㆍ구 콘크리트의 접합면 조건에 다른 부착특성)

  • 주봉철;김영진;김병석;박성룡;김덕진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.859-864
    • /
    • 2003
  • In these days, the deterioration of bridges make it necessary for decks to be replaced and it is inevitable to apply the precast decks to minimize the traffic control induced from the deck placement. This precast deck construction makes the physically discontinuous interface between old and new concrete. Usually, the adhesive force at this interface are ignored. However, for crack behavior and reliable long term behavior, it is required to evaluate the exact value of the cohesive force at the interface. This research investigates the cohesive characteristics at the interface. Four different interface surface conditions are tested and three different methods are used to measure the cohesive strength at the interface. In addition, cohesive characteristic at the surface between precast panels are investigated with different interface surface conditions.

  • PDF

Parallel Multiple Electric Power Conversion System Constructed by Connecting Three Power Converters

  • Nakai, Mitsuki;Inaba, Hiromi;Kishine, Keiji;Ishikura, Keisuke
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.3
    • /
    • pp.276-281
    • /
    • 2014
  • The electric power conversion system constructed by connecting two or more power converters in parallel is an advantageous method for making to large capacity and standardization. In this paper, the control method of cross current when three power converters are operated is examined, and it reexamined a preferable system construction method.