• Title/Summary/Keyword: construction control

Search Result 5,209, Processing Time 0.032 seconds

Cause Analysis of Flow Accelerated Corrosion and Erosion-Corrosion Cases in Korea Nuclear Power Plants

  • Lee, Y.S.;Lee, S.H.;Hwang, K.M.
    • Corrosion Science and Technology
    • /
    • v.15 no.4
    • /
    • pp.182-188
    • /
    • 2016
  • Significant piping wall thinning caused by Flow-Accelerated Corrosion (FAC) and Erosion-Corrosion (EC) continues to occur, even after the Mihama Power Station unit 3 secondary pipe rupture in 2004, in which workers were seriously injured or died. Nuclear power plants in many countries have experienced FAC and EC-related cases in steam cycle piping systems. Korea has also experienced piping wall thinning cases including thinning in the downstream straight pipe of a check valve in a feedwater pump line, the downstream elbow of a control valve in a feedwater flow control line, and failure of the straight pipe downstream of an orifice in an auxiliary steam return line. Cause analyses were performed by reviewing thickness data using Ultrasonic Techniques (UT) and, Scanning Electron Microscope (SEM) images for the failed pipe, and numerical simulation results for FAC and EC cases in Korea Nuclear Power Plants. It was concluded that the main cause of wall thinning for the downstream pipe of a check valve is FAC caused by water vortex flow due to the internal flow shape of a check valve, the main cause of wall thinning for the downstream elbow of a control valve is FAC caused by a thickness difference with the upstream pipe, and the main cause of wall thinning for the downstream pipe of an orifice is FAC and EC caused by liquid droplets and vortex flow. In order to investigate more cases, additional analyses were performed with the review of a lot of thickness data for inspected pipes. The results showed that pipe wall thinning was also affected by the operating condition of upstream equipment. Management of FAC and EC based on these cases will focus on the downstream piping of abnormal or unusual operated equipment.

Shape Design Sensitivity Analysis using Isogeometric Approach (CAD 형상을 활용한 설계 민감도 해석)

  • Ha, Seung-Hyun;Cho, Seon-Ho
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2007.04a
    • /
    • pp.577-582
    • /
    • 2007
  • A variational formulation for plane elasticity problems is derived based on an isogeometric approach. The isogeometric analysis is an emerging methodology such that the basis functions in analysis domain arc generated directly from NURBS (Non-Uniform Rational B-Splines) geometry. Thus. the solution space can be represented in terms of the same functions to represent the geometry. The coefficients of basis functions or the control variables play the role of degrees-of-freedom. Furthermore, due to h-. p-, and k-refinement schemes, the high order geometric features can be described exactly and easily without tedious re-meshing process. The isogeometric sensitivity analysis method enables us to analyze arbitrarily shaped structures without re-meshing. Also, it provides a precise construction method of finite element model to exactly represent geometry using B-spline base functions in CAD geometric modeling. To obtain precise shape sensitivity, the normal and curvature of boundary should be taken into account in the shape sensitivity expressions. However, in conventional finite element methods, the normal information is inaccurate and the curvature is generally missing due to the use of linear interpolation functions. A continuum-based adjoint sensitivity analysis method using the isogeometric approach is derived for the plane elasticity problems. The conventional shape optimization using the finite element method has some difficulties in the parameterization of boundary. In isogeometric analysis, however, the geometric properties arc already embedded in the B-spline shape functions and control points. The perturbation of control points in isogeometric analysis automatically results in shape changes. Using the conventional finite clement method, the inter-element continuity of the design space is not guaranteed so that the normal vector and curvature arc not accurate enough. On tile other hand, in isogeometric analysis, these values arc continuous over the whole design space so that accurate shape sensitivity can be obtained. Through numerical examples, the developed isogeometric sensitivity analysis method is verified to show excellent agreement with finite difference sensitivity.

  • PDF

The Method of Thermal Crack Control about the LNG Tank Wall in Winter (LNG 저장탱크 벽체의 동절기 온도균열제어 방안)

  • Son, Young-Jun;Ha, Jae-Dam;Um, Tai-Sun;Lee, Jong-Ryul;Baek, Seung-Jun;Park, Chan-Kyu
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.637-640
    • /
    • 2008
  • Since the first underground LNG tank was constructed in Incheon, continuously many LNG tanks were constructed in Tongyoung and Pyongtaek. The storage capacity of LNG tank increased by 200,000kl and the structure size and the concrete mixing design has changed. The crack of concrete induced by the heat of hydration is a serious problem, particularly in massive concrete structures. In order to control the thermal crack of massive concrete, the low heat portland cement(type Ⅳ) is applied to bottom annular part, bottom central part, lower walls and ring beam. In this study, in order to thermal crack control about the LNG tank wall(lot 8 of #16 Pyongtaek LNG tank) in winter, analysed the concrete temperature, the extention of term, the curing condition and the concrete mixing design. When the concrete mixing design is changed from OPC+FA25% to LHC+FA25%, the thermal crack index is 1.33 and satisfied with construction specifications(over 1.2).

  • PDF

The Improvement Method of Position Accuracy of Digital-Map in Small Area (소규모 지역에서 수치지도의 위치정확도 향상 방안에 관한 연구)

  • 이근상;장영률
    • Spatial Information Research
    • /
    • v.9 no.2
    • /
    • pp.263-275
    • /
    • 2001
  • With increasing of utilization of 1/1,000 Digital-Map being constructed with NGIS project, it is entering upon the stage that problem as the inspection of position accuracy of Digital-Map before its use. This paper evaluated position accuracy of Digital-Map being based on the construction of college facility management system into small area and presented modification/renovation of Digital-Map on area being occurred position error. With a view to evaluation of position error to building using RTK survey, position error was shown more than 0.5mm that is prescribed in survey-law. In order to acquire good position accuracy, first we carried out Static survey to college and selected control point. And, we evaluated coordinate value to important building from control point and compared these results with RTK survey results. Second, we carried out Affine transform based on the control point of building being surveyed with RTK, transformed pre-constructed Digital-Map and compared these results with RTK Survey results. We analyzed first and second method and presented improvement method of position accuracy of Digital-Map suited on small area.

  • PDF

Network Management Script Construction in Delegation Model (위임 모델에서의 네트워크 관리 스크립트 작성에 관한 연구)

  • 한순희;이기현;조국현
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.17 no.11
    • /
    • pp.1228-1237
    • /
    • 1992
  • Network management represents those activities which control and moitor the use of resources. Remote delegation model supports flexible and effective distribution of management functions among managers and agents, and it may cause an reliable network management in a relatively complex and high-speed networks. in this model, managers delegate to agents execution of management programs as prescribed in a management scripting language. In addition, primitives included in the management programs enable agents to monitor and control localmanaged objects effectively. We suggest management algorithms in which management scripts are delegated from managers to agents and partiality implement OSI fault management. This mans gement algorithm can effectively support delegation and control concurrent accesses to management information. Moreover, it can be easily translated into object-based concurrent programming language: ABCL. In this paper, we will scrutinize some essential aspects of this management.

  • PDF

A Study on the Construction of Coastal VTS in Mokpo Coastal Waters (목포연안에서의 연안VTS설치에 관한 연구)

  • Moon, Beom-Sik;Jong, Jae-Yong;Gug, Seung-Gi;Kim, Se-Won;Park, Jin-Soo
    • Journal of Navigation and Port Research
    • /
    • v.26 no.3
    • /
    • pp.261-268
    • /
    • 2002
  • At recently, Oil spill accident of large size oiler that happen domestic and outside the country is occured to social impact us as well as economical damage in sea environment. Also, because spread extent of pollution accident is reaching harbor, bay and close water areas, as necessity that traffic control ships are sea place. VTS is changing to concept that control space is magnified gradually. Our country is operated to 14 harbors which is control center. But abroad is operating coastal VTS that do main waterway and coastals to authority dimension. Therefore, necessity that traffic density of ship manages high coastals and ship traffic of waterway to our country is risen. This paper is execute sea traffic survey at Mokop sea areas and sea casualty occurs. It proposal that coastal VTS center field of most suitable and position of radar site.

A Study on the Smart Outlet and Gateway Using Power Line Communication (전력선통신(PLC) 방식을 이용한 스마트콘센트와 게이트웨이에 관한 연구)

  • Park, Sung Jin;Kim, Yu Jin;Park, In Ji;Kim, Jin Young;Lim, Chang Gyoon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.4
    • /
    • pp.331-335
    • /
    • 2020
  • In this study, through the accumulated technologies such as real-time monitoring of power consumption using power line communication (PLC) method, power control, and automatic blocking of standby power, to commercialize them, we developed the hardware design, algorithm, protocol and module along with data transmission using PLC. We conducted the study to develop advanced products. We also proposed cloud-based smart outlet products with a novel type of outlet. These products can measure the internal power consumption through the H/W modules and the modules that control the power of household appliances connected to the smart outlets and smart plugs. Subsequently, they transmit the measurements to the energy saving system server via a communication module. This system can control the terminal device connected to the Gateway (G/W) server through a mobile phone. This will allow the customer to check the power consumption of the building at any given time, to turn the terminal on/off, and to maximize the energy efficiency during the construction of new apartments or multi-family housing in an area.

Performance Improvement of the Hydrostatic Piston Shoe Bearing of an EHA-Piston Pump under Boundary Friction Conditions (EHA 펌프용 피스톤 슈 정압베어링의 경계 마찰 성능 개선)

  • Hong, Y.S.;Kwon, Y.C.;Kim, C.H.;Lee, S.L.;Kim, B.K.;Moon, J.S.;Kim, J.H.
    • Journal of Drive and Control
    • /
    • v.11 no.2
    • /
    • pp.30-35
    • /
    • 2014
  • The pumps of electro-hydrostatic actuators operate most frequently in boundary lubrication speed range, as they compensate for the position control errors as a control element. When conventional swash plate type piston pumps are applied to electro-hydrostatic actuators, the frictional power losses as well as the wear rate of sliding components, such as piston shoes can increase drastically under the boundary friction condition. In this paper, the power losses of the piston shoes were investigated which were engendered by a frictional solid-to-solid contact and leakage flow rate of their hydrostatic bearing. In order to reduce them, DLC-coating was applied to the swash plate and the ball joint of pistons along with its effects were demonstrated. In addition, it was also shown that the wear rate of the piston shoes could be markedly reduced using the DLC-coated swash plate.

Structural Design of Vibration Controlled Tall Building with Overhang Structure

  • Ishibashi, Yoji;Yoshizawa, Katsuhito;Ogawa, Ichiro;Tamari, Masatoshi;Nagayama, Kenji;Oki, Hatsuka
    • International Journal of High-Rise Buildings
    • /
    • v.8 no.3
    • /
    • pp.177-183
    • /
    • 2019
  • This paper describes the structural design of a 212 m tall building currently under construction in the Tokiwabashi District Redevelopment Project facing Tokyo Station. In this project there was a requirement to rationally solve many issues arising from the conditions of the redevelopment project. In particular, the following two points were considered to be important from the point of view of structural design. 1) To provide an overhang frame with the perimeter columns on the lower stories inclined, in order to enable a typical floor area that greatly exceeded the limitations of the underground structure shape. 2) To provide high grade seismic performance for the office buildings to be constructed on prime city center land. LSCVCS (Lower Stories Concentrated Vibration Control System) was proposed as the method of rationally designing the overhang frame, which is an extremely disadvantageous element in the structural scheme of the tall building with a large slenderness ratio. LSCVCS is a system to provide effective damping by arranging vibration control devices in a concentrated manner in a lower story with large story height, that produces large deformation in an earthquake. Also, the vibration control devices arranged in the lower story are limited to viscous devices, to take into consideration the residual deformation of the overhang frame after an earthquake. The results of investigations into the specific effects of the system for the seismic design are reported, including Performance-based seismic design.

Measures to Improve the Efficacy of Road User-Centered VMS Traffic Information Offering (도로이용자 중심의 VMS 교통정보 제공 효용성 향상 방안)

  • Yoon, Young-Min
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.12
    • /
    • pp.190-201
    • /
    • 2021
  • The variable message sign (VMS) is equipment to improve the efficiency of traffic flow and safety of travel by providing real-time information to road users on traffic, road, weather situation, and traffic control due to construction. The information messages of the letter-based VMS taking up most of the VMS on the general national highways consist of section, travel time in sections, and road control situation. This study devised an improvement plan centered on road users, not road managers-centered existing message-based VMS through an analysis of road users' preference targeting the letter-based VMS operated in the general national highways in the Seoul Metropolitan Area. By presenting the measure for system improvement through which information on unexpected situations that road users prefer the most can be quickly and efficiently provided, this study aims to improve the efficiency of road user-centered VMS traffic information.