• Title/Summary/Keyword: construction control

Search Result 5,209, Processing Time 0.034 seconds

The Study on Algorithm for Partial shade Compasation of PV (태양광 발전시스템의 부분그늘 보상을 위한 알고리즘에 관한 연구)

  • Koh K. H.;Lee H. W.;Suh K. Y.;Koh H. S.;Moon S. C.
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.271-274
    • /
    • 2003
  • In this paper, compare and analyze existent MPPT algorithms. Existent algorithms have defects which don't generate it in a partial shade or low insolation. Therefore, to supplement it, we design improved IncCond algorithm consisted of a Aux. switch and capacitor with Generation Control circuit which can always obtain maximum generation power at the factor which is reduced generational efficiency by partial shade. Generation Control circuit is method which can always get maximum output power as it regularly controls each voltage of serial connected solar cell. Accordingly, it can improve efficiency and confidence of utility interaction inverter. Construction of system use a low price PIC16F87X. We analyze special character according to system operation through simulation and prove the validity through experiments.

  • PDF

THD Analysis of a Hydraulic Servo Valve Using CFD (CFD를 이용한 유압 서보밸브의 열유체 해석)

  • Jeong, Y.H.;Park, T.J.
    • Journal of Drive and Control
    • /
    • v.11 no.1
    • /
    • pp.8-13
    • /
    • 2014
  • Hydraulic servo valves are widely used in various fluid power systems because of their fast response and precision control. In this paper, we studied the effect of metering notch shapes and amount of their openings on the flow characteristics within the spool valve using a computational fluid dynamic (CFD) code, FLUENT. To obtain the results for more realistic operating conditions, viscous heating due to the jet flow and viscosity variation of the hydraulic fluid with temperature were considered. For two types of notch shape, streamlines, oil temperature and viscosity distributions, and variations of flow and friction forces acting on spool were showed. The flow and friction forces affected by the metering notch shapes and their openings, and oil temperature rise near metering notch was significant enough to results in the jamming phenomenon. A thermohydrodynamic (THD) flow analysis adopted in this paper can be used in optimum design of hydraulic servo valves.

The AS4059 Hydraulic System Cleanliness Classification System: Replacement of NAS1638

  • Day, Mik;Hong, Jeong-Hee
    • Journal of Drive and Control
    • /
    • v.9 no.2
    • /
    • pp.39-45
    • /
    • 2012
  • The NAS 1638 cleanliness classification system was originally developed in 1966 by the US Aircraft Industries of America to both simplify reporting of particle count data and to control the introduction of dirt during the assembly of aircraft fluid systems. The numbers of particles at stated sizes are represented by broad bands where the interval was generally a doubling of contamination. A number of systems have been introduced since this to suit differing requirements. NAS 1638 and AS4059 are used in other industrial sectors such as the Off-shore & Sub-Sea and the Primary Metal Industries. The changes to ISO contamination measurement standards controlled by ISO/TC131/SC6 in 1999 meant that a revision of most of these classification systems was necessary. The body responsible for NAS 1638 decided to withdraw it for new installations and replace it with an update of an existing standard, SAE AS 4059. This paper details the philosophy behind the contamination coding systems, the reasons for the changes to the ISO contamination standards and explains the workings of AS 4059, the replacement for NAS 1638. It goes on to detail the latest changes to this standard.

Community Structure and Spatial Variation of Meiobenthos Associated with an Artificial Structure (퇴적촉진 구조물 설치에 따른 중형저서동물 군집구조 및 변동)

  • Min Won-Gi;Kim Dong-Sung;Lee Jae-Hac
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.39 no.spc1
    • /
    • pp.223-230
    • /
    • 2006
  • We investigated the spring and summer community structure of meiobenthos in a tidal-falt near Iwon, Korea, in 2002 and 2003. In total, 12 meiofaunal groups were found in the study area among which nematodes were the most dominant. Benthic foraminiferans, harpacticoid copepods, polychaetes, and crustacean nauplli were also dominant groups at all sites. The total density of meiobenthos at each station was be 246-2,177 ind./$10cm^2$. As the depth of sediment increased, the density of meiobenthos at each station gradually decreased. Changes in the vertical distribution of meiobenthos in the study area occurred mainly near the sediment surface (0-1 cm). Generally, between spring and summer the density of nematodes increased, and the density of other dominant meiofaunal groups (benthic harpacticoids, crustacean nauplii, benthic foraminiferans) decreased near the sediment trap the control site of sediment traps compared to that at the control site. The results of cluster and multidimensional scaling plots indicate that the meiofaunal community changed following construction of a low artificial wood groin structure.

A study on the 3-D positional analysis for track of magnetically levitated vehicles (자기부상열차 선로의 3차원 위치해석에 관한 연구)

  • 강준묵;윤희천;배상호
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.13 no.2
    • /
    • pp.229-236
    • /
    • 1995
  • This study is the 3-D positional analysis for track of magnetically levitated vehicles to precise construction and periodical safe diagnosis by photogrammetry. In the result, we could improve the accuracy of Z as well as X, Y using the modified control points of spatial distribution to the plane distribution of the absolutly effective control points to accuracy and diagnosis the the track of magnetically levitated vehicles using the below 1㎜ accuracy. And we could analysis the 3-D precise positions and efficiently decide the geometric characteristics of the cant and gradient to the instrument.

  • PDF

A Study on the Design Factors of Complex Damper for Ventilation and Fire Protection (환기 및 소방용 복합댐퍼의 설계인자에 관한 연구)

  • Lee, Dong-Myung
    • Fire Science and Engineering
    • /
    • v.25 no.4
    • /
    • pp.42-47
    • /
    • 2011
  • This study carried out the design and analysis of complex damper as basis study for development of complex damper for ventilation and fire protection. This study established design and analysis theory of complex damper based on process, kinematics mechanism and mechanism modelling of complex damper. And this study established engineering data construction and a source technology that can design each element of complex damper through motion analysis simulation based on design and analysis theory. Therefore, it got result that can apply comprehensively in development of complex damper for ventilation and fire protection from this study. Also, it sees that can ready control means and technological countermeasure of smoke to developed of complex damper with this study.

Performance Evaluation of Response Reduction of Outrigger Damper System Subjected to Wind Loads (풍하중에 대한 아웃리거 댐퍼시스템의 응답 제어 성능 평가)

  • Kim, Su-Jin;Kim, Min-Ju;Kim, Jun-Il;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.18 no.2
    • /
    • pp.35-42
    • /
    • 2018
  • The outrigger damper system is a structural system with excellent lateral resistance when a wind load occurs. However, research on outrigger dampers is still in its infancy. In this study, dynamic response control performance of damper is analyzed according to change of stiffness value and damping value of damper. To do this, a real-scale 3D model of 50 stories has been developed and the artificial wind load has been entered for dynamic analysis. Generally, the larger the damping value, the smaller the stiffness value is, the more effective it is to reduce the maximum displacement and acceleration response. However, the larger the attenuation value as the cost of construction increases, it is necessary to select appropriate stiffness and damping value when applying an outrigger damper.

A Study on the Indoor Air Quality in the bedroom with respect to Temperature and Humidity conditions (온도 및 습도 조건에 따른 침실 공기환경에 관한 연구)

  • Kim, Dong-Gyu;Kim, Se-Hwan
    • KIEAE Journal
    • /
    • v.11 no.3
    • /
    • pp.31-36
    • /
    • 2011
  • People spend most of their time inside buildings recently, so the indoor air quality is one of the most important factors to human health. Furthermore, minimum energy use with proper ventilation systems for pleasant indoor environment is necessary because of energy shortage over the world. The concern to maintain proper indoor air quality at home has been increased, and a proper indoor air quality is continuously requested by the residents. By measuring and analyzing the density fluctuation of $CO_2$ through indoor humidity and testing personal reactions regarding comfort condition, we can obtain a way to effective ventilation. Heat and carbon dioxide emissions from resident's metabolism and construction materials could be the causes of indoor air pollution. If these materials stay indoors for a long time, it could directly influence the resident's health condition with diseases. It also leads massive energy use. Therefore, the way to save energy and to have effective control of indoor ventilation is needed. This study presented the control method of bedroom ventilation by $CO_2$ concentration change and subjective evaluation.

Control of One Dimensional Inverse Scattering Pattern and Its Applications (일차원 역산란 패턴 제어와 그 응용)

  • 최종인;박의준
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.2
    • /
    • pp.291-301
    • /
    • 1999
  • A method for the synthesis of one-dimensional nonlinear distribution function is presented for the desired inverse scattering pattern. This method is based on the inverse transform of the solution of the Riccati equation derived from one-dimensional inverse scattering problem. Since the solution is analogous to the array factor or normalized space factor in collinear array antenna, the synthesis method for field pattern is applied for the construction of the involved line-source nonlinear distribution function. The suggested method is carried out under the optimization process, and is numerically verified by synthesizing the dispersive transmission line profile within the specified frequency band and control of scattered field on resistive strip.

  • PDF

A Study of Voltage Control for Lower Side Parallel Transformer (병렬운전 변압기 전압제어 및 저압축 모선보호방식연구)

  • Yun, Gi-Seob;Baek, Seung-Do;Choi, Hyuck-Jong
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.233-236
    • /
    • 2001
  • Parallel operation scheme to several transformers is adopted because of the load increase, economic problem, or load shedding. For the transformer's parallel operation, loads proportional to each transformer's capacity must be allotted, and circulation currents must be limited as much as without causing any problem in a real operation. But, both transformers in parallel operation can be tripped when either faults at lower voltage side of a transformer or faults in a bus occurs. Therefore, parallel operation scheme to distribution transformers in Korea is not adopted in a normal state but only when loaded or load-shedded. These are due to the insufficiency of the construction in communication network and AVR scheme. Besides that, those are because bus bar protection scheme to lower voltage side of a transformer is not applied. In spite of enormous initial investment costs, advanced countries take so much account of power system reliability and stable supply that they adopt the parallel operation scheme in a normal state. One of the problems in parallel operation is the overheat of transformers due to the excessive circulation currents. This paper presents the scheme that controls voltages between both transformers using circulation currents that occurs in parallel operation.

  • PDF