• 제목/요약/키워드: constant-release

검색결과 254건 처리시간 0.021초

관절경하 관절낭 유리술과 강압교정술을 병용한 동결견의 치료 (Treatment of Frozen Shoulder under the Arthroscopic Capsular Release Combined with Manipulation)

  • 유연식;이영현;이상수;남일현
    • Clinics in Shoulder and Elbow
    • /
    • 제4권2호
    • /
    • pp.166-172
    • /
    • 2001
  • 동결견의 치료에 있어 관절경하 관절낭 유리술과 더불어 강압교정술을 겸용한 적극적인 치료방법은 견관절부 동통 완화와 견관절 운동 범위 회복에 있어 양호한 결과를 얻을 수 있으며 강압교정이나 관절경하 관절낭 유리술의 단독 시행에서 보일수 있는 합병증을 현저히 줄일 수 있고 특히, 심한 동통 및 관절 운동 제한을 보이는 환자에서 이환 기간 단축 및 관절 운동 범위 회복에 있어 보존적 치료에 비해 우수한 방법으로 사료된다.

  • PDF

근막통증 증후군 환자에게 체외충격파와 근막이완술 병행 치료가 통증, 움직임, 기능에 미치는 영향 (Effects of Extracorporeal Shock Wave Therapy with Myofascial Release Techniques on Pain, Movement, and Function in Patients with Myofascial Pain Syndrome)

  • 최원재;남은정;김현중;이승원
    • PNF and Movement
    • /
    • 제18권2호
    • /
    • pp.245-254
    • /
    • 2020
  • Purpose: The study investigated the effects of extracorporeal shock wave therapy with myofascial release techniques (ESWT+MFR) on pain, movement, and function in patients with myofascial pain syndrome. Methods: Forty participants with upper trapezius trigger points were recruited and randomly allocated to two groups: an experimental group (n = 20) and a control group (n = 20). The experimental group performed the ESWT+MFR, and the control group performed only myofascial release techniques. Each group was treated for 15 minutes, twice a week for four weeks. Pain was assessed using a visual analogue scale and a pressure pain threshold measure. Movement was assessed by cervical range of motion, and cervical and shoulder function were assessed on the Constant-Murley Scale and the Neck Disability Index before and after treatment. Results: The results indicate statistically significant improvements in the two groups on all parameters after intervention as compared to baseline (p < 0.05). As compared to the control group, the experimental group showed statistically significant improvements on the visual analogue scale and pressure pain threshold, cervical range of motion (except rotation), and on the Neck Disability Index (p < 0.05). Conclusion: The ESWT+MFR is more effective than myofascial release techniques for pain, movement, and function in patients with myofascial pain syndrome and would be clinically useful for physical therapists treating myofascial pain syndrome.

Poly(ε-caprolactone) Microcapsule with Encapsulated Nifedipine Prepared by Magnetic Stirrer

  • Lee, Hyeran;Lee, Deuk Yong;Song, Yo-Seung;Kim, Bae-Yeon
    • 대한의용생체공학회:의공학회지
    • /
    • 제40권1호
    • /
    • pp.7-14
    • /
    • 2019
  • The microencapsulation of nifedipine (NF) with 4 wt% of poly(${\varepsilon}-caprolactone$) (PCL)/polyvinylpyrollidone (PVP) or PCL/polyethylene glycol (PEG) was carried out by solvent evaporation method in oil in water emulsion system to investigate the effect of PVP and PEG addition on drug release behavior of the microcapsules. The PVA (emulsifier) concentration of 1.0 wt% was chosen for the formation of PCL capsule having an average size of $154{\pm}25{\mu}m$ due to nearly spherical shape with a narrow size distribution. As PCL/PVP and PCL/PEG ratios were raised from 10/0 to 6/4, the capsule size increased gradually from $154{\pm}25{\mu}m$ to $236{\pm}32{\mu}m$ and $248{\pm}56{\mu}m$, respectively. The drug release rate of PCL/PVP and PCL/PEG capsules increased dramatically from 0 to 4 h at the beginning and then reached the plateau region from 20 h. As the concentration of PVP or PEG increased, the amount of drug release increased, suggesting that the larger capsule size was attributed to the higher drug content. However, the drug release behavior remained almost constant. The PCL capsules exhibited no evidence of causing cell lysis or toxicity regardless of NF loading, implying that the microcapsules are clinically suitable for use as drug delivery systems.

Long-term Dissolution Behavior of Cesium from Spent PWR Fuel in Contact with Compacted Bentonite under Synthetic Granitic Groundwater

  • Chun, Kwan-Sik;Kim, Seung-Soo;Bak, Seong-Jea;Park, Jongwon
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2004년도 학술논문집
    • /
    • pp.167-173
    • /
    • 2004
  • The amount of cesium released from the leaching of spent fuels in contact with and without the compacted bentonite bloc]t which was compacted as the density of $1.4g/\textrm{cm}^3$, up to 5.7 years were measured and the empirical formula of the fractional release rate of cesium were derived from these measured values. The empirical formulas show that the long-term release rate of cesium under a repository would become a constant, as about $3{\times}10_{-6}$ fraction/day, after a certain period. The cumulative fractions of cesium released from the spent fuel with bentonite and with copper and stainless steel sheets were steadily increased, but the fraction from bare fuel was rapidly increased and then sluggishly increased. However, the remained value except its gap inventory from the cumulative fraction of cesium released from bare fuel was almost very close to the others. This suggests that the initial release of cesium from bare fuel might be dependant on its gap inventory.

  • PDF

양이온교환수지복합체에 의한 페닐프로판올아민염산염의 제조 및 평가 (Preparation and Evaluation of Phenylpropanolamine HCI by Complexation with Cation Exchange Resin)

  • 김인규;이경태;서성훈;김종국;김동현;노영수
    • Journal of Pharmaceutical Investigation
    • /
    • 제29권4호
    • /
    • pp.309-313
    • /
    • 1999
  • This study was prepared to develop the sustained release dosage form of phenylpropanolamine hydrochloride (PPA) by complexation with cation exchange resin(CER). The PPA-CER complex was confirmed by differential scanning calorimetry(DSC) thennogram, indicating a relative shift of an endometric peak of PPA to higher temperature. The loading efficiency was increased as the amount of PPA was increased as well as the time of fractional exchange was advanced as the temperatures were increased. Loading efficiency, fractional exchange, reaction rate constant and activation energy were highly dependent on the temperature and drug : resin ratio. The optimal ratio of PPA and resin was estimated to be 10: 10 for the sustained release.

  • PDF

방죽포 쇄파대생태계의 수용력과 수산자원방류 (Carrying Capacity and Fishery Resources Release in the Bangjukpo Surfzone Ecosystem)

  • 강윤호
    • 한국수산과학회지
    • /
    • 제36권6호
    • /
    • pp.669-675
    • /
    • 2003
  • To increase fishery resources in coastal waters, juvenile fish and bivalves are artificially released every year in Korea. This study provides a methodology to estimate an optimal release quantity based on the carrying capacity of the receiving basins. Carrying capacity was defined by E.p. Odum's theory of ecosystem development as the upper limit of biomass, where total system respiration equals total primary production. The Ecopath trophic ecological model was used to determine carrying capacity in the surfzone ecosystem of Bangjukpo on the southern coast of Korea. Using a top-down control method, various biomasses of fish groups were given to the simulation, with primary production constant and no catch. The results showed that biomass of selected fish groups increased by two orders of magnitude, yielding a five-fold increase in overall consumer biomass. The resultant values are 10 times higher than those estimated in open seas. This can be explained by higher primary production in the Bangjukpo surfzone ecosystem. This method can be used for strategic releases and ecosystem management, particularly when based on an ecological background.

Burning Characteristics of Wood-based Materials using Cone Calorimeter and Inclined Panel Tests

  • Park, Joo-Saeng;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • 제30권3호
    • /
    • pp.18-25
    • /
    • 2002
  • Research to discuss the fire performance of materials requires tools for measuring their burning characteristics and validated fire growth models to predict fire behavior of the materials under specific tire scenarios using the measured properties as input for the models. In this study, burning characteristics such as time to ignition, weight loss rate, flame spread, heat release rate, total heat evolved, and effective heat of combustion for four types of wood-based materials were evaluated using the cone calorimeter and inclined panel tests. Time to ignition was affected by not only surface condition and specific gravity of the tested materials but also the type and magnitude of heat source. Results of weight loss rate, measured by inclined panel tests, indicated that heat transfer from the contacted flame used as the heat source into the inner part of the specimen was inversely proportional to specific gravity of material. Flame spread was closely related with ignition time at the near part of burning zone. Under constant and severe external heat flux, there was little difference in weight loss rate and total heat evolved between four types of wood-based panels. More applied heat flux caused by longer ignition time induced a higher first peak value of heat release rate. Burning characteristics data measured in this study can be used effectively as input for fire growth models to predict the fire behavior of materials under specific fire scenarios.

쳔연가스 연료조성이 엔진 연소특성에 미치는 영향 (Effects of Natural Gas Composition on Combustion Characteristics in a Gas Engine)

  • 이중성;유현석;윤영석;한정옥
    • 한국자동차공학회논문집
    • /
    • 제7권6호
    • /
    • pp.32-41
    • /
    • 1999
  • Natural gas is an attractive fuel in view of environment benefits due to its flow carbon-to-hydrogen ratio. However, its compositions and properties are varied depending upon production regional groups. Therefore, study on the combustion characteristics of natural gas engines with a variety of compositions has been demanded for the efficient application of gas engines. This study aims to investigate the effects of gas composition on engine combustion characteristics. It was found that , by controlling an engine with fixed fuel nozzle area, power and heat release were subject to Wobbe Index. And at fixed excess air ratios, power and heat release were subject to low heating value of unit mixture . In addition, in case of constant nozzle area, combustion duration was found to be inversely proportional to CP(Combustion Potential), and the condition of fixed excess air ratios showed no change in combustion duration, regardless of CP.

  • PDF

직접분사식 수소연료의 분무 및 연소특성에 관한 연구 (A Study on the Characteristics of Injection and Combustion with Directly Injected Hydrogen Fuel)

  • 이성욱;기완수
    • 한국자동차공학회논문집
    • /
    • 제15권5호
    • /
    • pp.24-29
    • /
    • 2007
  • This study aims to provide a fundamental data for directly injected hydrogen fuel engines. Spray, ignition and combustion characteristics of hydrogen were studied using constant volume chamber. For spray visualization, hydrogen was vertically injected into a combustion chamber at various condition, for example, injection pressure, ambient pressure. And an argon laser was used for the shadowgraph photography by applying optical method. Also, to investigate heat-release rate and flame propagations, spark was ignited on hydrogen injected at the different time after injection and the duration of injection was also changed. Processes of ignition and combustion were analyzed by heat-release rate calculated by pressure history and were observed by shadowgraph photography The results gave much knowledge of spray, ignition and combustion characteristics of hydrogen.

케이블 화재의 화염전파 해석을 위한 FDS 모델의 격자민감도 평가 (Assessment of Grid Sensitivity in the FDS Field Model to Simulate the Flame Propagation of an Electric Cable Fire)

  • 김성찬;이성혁
    • 한국안전학회지
    • /
    • 제23권4호
    • /
    • pp.30-35
    • /
    • 2008
  • The present study has been conducted to examine the effect of grid resolution on the predicted results for electric cable fire using pyrolysis model in FDS(Fire Dynamics Simulator, version 5). The grid independent test for different grid resolutions has been performed for a PE coating cable and the grid resolution is defined by the non-dimensional characteristic length of fire and mean grid size. The calculated maximum heat release rate and mean flame spread rate were almost constant for higher grid resolution of 20${\sim}$25 and the computing time for the grid resolution takes approximately 20hours to solve flame propagation with pyrolysis model. The geometrical simplification of a electric cable dose not greatly affect on the maximum heat release rate and flame spread rate and the rectangular approximation of cable shape gives acceptable result comparing with the round cable with stepwise grid.