• Title/Summary/Keyword: constant width

Search Result 626, Processing Time 0.036 seconds

A Study on the Behaviour of Ultra-High Pressure Diesel Spray by Electronic Hydraulic Fuel Injection System(II) (전자유압식 분사계에 의한 초고압 디젤분무의 거동에 관한 연구(II))

  • 장세호;안수길
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.5
    • /
    • pp.182-190
    • /
    • 1998
  • Behaviour of ultra-high pressure diesel spray in a constant-volume pressure chamber was studied with injection pressure ranging from 20 to 160㎫. Sprays were observed by the right angle scattering method. As a result, the spray tip penetration is first proportional to a time, and after that, it is proportional to 0.52 of the time during at the time of injection pressure and back pressure increase. An empirical correlation was made for the parameters of injection pressure, air-fuel density ratio, spray tip distance, spray angle, jet angle of spray and max. spray width.

  • PDF

A Study on the Pressure Control Characteristics of ON/OFF 3-way Solenoid Valve Driven by PWM Signal (개폐식 3방향 전자밸브의 펄스폭 변조 구동에 의한 압력제어 특성에 관한 연구)

  • Jeong, Heon-Sul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.3
    • /
    • pp.485-501
    • /
    • 1997
  • Pressure control is possible driving a simple ON/OFF 3-way valve of hydraulic servo system by pulse width modulation signal. But the pressure varies according to the duty ratio and carrier frequency and repeated on-off action induces pressure fluctuation. So equations for mean pressure and ripple amplitude are theoretically derived as a function of on/off time, the system parameters which decide the pressure characteristics are arranged and they are verified by experimental study. As the result selection criteria for the major design parameters are established and the basic strategy to suppress the unnecessary fluctuation can be provided for a hydraulic pressure control system using these type of valves.

Joinability of Tool Steels by TLP Bonding (천이액상확산접합에 의한 합금공구강의 접합특성)

  • 권병대;이원배;김봉수;홍태환;서창제;정승부
    • Journal of Welding and Joining
    • /
    • v.21 no.4
    • /
    • pp.69-74
    • /
    • 2003
  • The mechanical properties of STD11 Joints by using TLP (Transient Liquid Phase Diffusion) bonding method employing MBF-30 and MBF-80 insert metals were investigated with concerning to the microstructural change. TLP bonding of STD 11 was carried out at 1323∼1423K for 0.6ks∼3.6ks in vacuum. The microstructure and the element distribution of the interlayer between tool steels and insert metals showed specific feature with bonding conditions. It was found that the width of the interlayer increased at initial bonding stage. However, the width of interlayer showed nearly constant value during the isothermal solidification. After isothermal solidification was completed, the joint showed homogeneous element distribution and similar microstructure with base metal because of the grain boundary migration to the bonded interlayer. The bonding strength measured by a tensile test has been varied with the bonding conditions. The maximum joint strength, 760MPa, was obtained with the condition of 1423K for 1.2ks using MBF30 insert metal in this experiment.

Limit load analyses of weld-center cracked plates under tension (용접부 중앙에 균열이 존재하는 인장 평판에 대한 한계하중 해석)

  • Song, Tae-Kwang;Kim, Yun-Jae;Kim, Jong-Sung;Jin, Tae-Eun
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1830-1835
    • /
    • 2007
  • In the present work, the effect of strength mismatch on plastic limit loads is quantified for strength-mismatched plates with constant-depth surface cracks under tension, via three-dimensional, small strain elastic-perfectly plastic finite element analyses. Relevant variables related to plate and crack geometries are systematically varied, in addition to the weld width. An important finding is that a parameter related to the weld width-to-ligament ratio is proposed, based on which limit loads can be uniquely quantified. The proposed limit load solutions is a valuable input to estimate nonlinear fracture mechanics parameters based on the reference stress approach.

  • PDF

Shape Optimization of a Micro-Channel Using Kriging Model (크리깅 모델을 이용한 미세유로의 형상최적설계)

  • Husain, Afzal;Kim, Kwang-Yong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.9
    • /
    • pp.733-740
    • /
    • 2007
  • Microchannel heat sink shape optimization is performed using Kriging method. Design variables relating to microchannel width, depth and fin width are selected, and thermal resistance has been taken as objective function. Design points are selected through a three-level fractional factorial design of sampling method. Navier-Stokes and energy equations for laminar flow and conjugate heat transfer are solved at these design points using a finite volume solver. Solutions are carefully validated with experimental results. Using the numerically evaluated objective function, a surrogate model (Kriging) is constructed and optimum point is searched by sequential quadratic programming. The process of shape optimization greatly improves the thermal performance of microchannel heat sink under constant pumping power.

Time- Dependent FEM Simulation of Dilution Control of Laser Cladding by Adaptive Mesh Method

  • Kim, Jae-Do;Peng, Yun
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.177-187
    • /
    • 2000
  • Dilution is an important factor which influences the properties of clad layer. In this paper the change of dilution during laser cladding and the control of dilution are simulated by a finite element method. The adaptive mesh method is adopted for the time-dependent finite element method computation so that the shape of melt pool can be well represented. The situation of the width control of melt pool is also simulated, which indicates that the dilution can be controlled if the width of melt pool is controlled. Computational results indicate that if a line energy (input energy per unit distance) remains constant the dilution will increase with time, especially at the beginning. Simulation results show that it is possible to control dilution in a certain range if the line energy decreases with time. Experiment of Nd: YAG laser cladding with wire feeding is performed. Experiment results coincide well with the FEM results.

  • PDF

Study on contact resistance on the performance of Oxide thin film transistors (산화물 박막 트랜지스터 동작에 대한 접촉 저항의 영향)

  • Lee, Jae-Sang;Chang, Seong-Pil;Koo, Sang-Mo;Lee, Sang-Yeol
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.04b
    • /
    • pp.63-64
    • /
    • 2009
  • The TFTs have been fabricated with 3 different geometry SID electrodes which have the same channel W/L ratio (W/L = 5) due to constant channel resistance, The 3 samples have different channel widths (350, 150, and $25\;{\mu}m$) and channel lengths (70, 30, and $5\;{\mu}m$) by fixed channel W/L ratio simultaneously on one chip for reliable comparisons. Resultant on-current and field effect mobility are proportional to the channel width, while the subthreshold swing is inversely proportional to the channel width mainly due to the change of contact resistance. These results show that the contact resistance strongly affects the device performances and should be considered in the applications.

  • PDF

Study on the Ld, Lq Characteristic Parameter of Interior Permanent Magnet Synchronous Motor in different barrier width (배리어 길이에 따른 매입형 영구자석 동기전동기의 Ld, Lq 특성 파라미터에 관한 연구)

  • Jang, Ik-Sang;Jin, Chang-Sung;Jung, Dae-Sung;Kim, Seung-Joo;Park, Jae-Young;Lee, Ju
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.709-710
    • /
    • 2008
  • In this paper, we calculated permanent magnetic linkage flux ${\psi}_{\alpha}$ and Ld, Lq parameters of IPMSM and compared two model which has different barrier width. IPMSM has two kinds of torque that reluctance torque and magnetic torque. In constant torque region, using the Maxwell stress tensor method, we calculated the torque and current phase angle ${\beta}$ which has appeared maximum torque. In weakening flux region, we calculated the current phase angle ${\beta}$ which flux ${\psi}_o$ lower than limited flux ${\psi}_{omax}$. From the current phase angle ${\beta}$, we calculated torque by torque equation and compared two model characteristic.

  • PDF

A stusdy on DC-DC Converter using characteristic of series resonance (공진특성을 이용한 DC-DC Converter에 관한 연구)

  • Ro, Chae-Gyun;Kim, Sung-Chul;Bae, Jin-Ho;Shin, Dong-Sam
    • Proceedings of the KIEE Conference
    • /
    • 1990.07a
    • /
    • pp.383-386
    • /
    • 1990
  • This paper concerns a DC-DC converter using the characteristic of series resonance. Operation principle of the system described by the proposed equation is illustrated. Characteristics of steady state of the system which is essential to system design is evaluated for frequency and pulse width characteristic using dimensionless parameter. The proposed circuit based in constant voltage control uses the Pulse Width Modulation - Time Ratio Control method.

  • PDF

Three Dimensional Finite Element Analysis of Structures under Wind Loads (풍하중을 받는 구조물의 3차원 유한요소해석)

  • 김병완;김운학;이인원
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2001.04a
    • /
    • pp.26-33
    • /
    • 2001
  • This paper compares conventional beam analyses with exact three dimensional plate analyses through numerical examples with plates under wind loads in order to study the disadvantages of conventional simplified beam analyses of wind-loaded structures, Bending moments and principal stresses from beam analyses are good agreements with those from plate analyses but torsional moments are not. And it is possible to get result forces which are variant along width directions from plate analyses but not from beam analyses due to constant distributions of result forces along width directions. Therefore exact three dimensional plate analyses are required in the analyses of wind-loaded structures instead of conventional simplified beam analyses.

  • PDF