• Title/Summary/Keyword: constant width

Search Result 626, Processing Time 0.022 seconds

Developmental Characteristics of Soybean Podworm, Matsumuraeses phaseoli (Lepidoptera: Tortricidae) and Legume Pod Borer, Maruca vitrata (Lepidoptera: Pyralidae) on Semi-synthetic Artificial Diets (반합성 인공사료에서 팥나방(Matsumuraeses phaseoli)과 콩명나방(Maruca vitrata)의 발육 특성)

  • Jung, Jin-Kyo;Seo, Bo-Yoon;Park, Jong-Ho;Moon, Jung-Kyung;Choi, Bong-Su;Lee, Young-Ho
    • Korean journal of applied entomology
    • /
    • v.46 no.3
    • /
    • pp.393-399
    • /
    • 2007
  • Two lepidopteran species, Matsumuraeses phaseoli (Matsumura) and Maruca vitrata (syn. M. testulalis) (Fabricius) were reared on artificial diets, and analyzed in their developmental characteristics. Photoperiod was supplied with 16L/8D for M. phaseoli and with 13L/11D for M. vitrata, respectively. Both species passed five larval instars with discrete sizes of head capsule width. In a constant environment ($25^{\circ}C$ and 65%RH), the developmental period of M. phaseoli egg, larva and pupa was 3.9, ca. 16.0 and 8.9 days, respectively, and over 80% of M. phaseoli larvae could develop into pupae, most of which emerged into adults. Newly laid eggs could be stored at $5^{\circ}C$ for 15 days with over 50% hatchability. Similar developmental traits were shown in M. vitrata. However, a low temperature preservation was not applicable to M. vitrata eggs.

A Design and Implementation of Circuit for Efficient Power LED Dimming Control (효율적인 고출력 LED 디밍 제어를 위한 회로 설계 및 구현)

  • Kim, Doo-Hyun;Choi, Jae-Ho;Cho, Beom-Joon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.9
    • /
    • pp.2280-2288
    • /
    • 2014
  • The conventional dimming control methods of LED (Light-emitting dioades) include Analog, PWM (Pulse Width Modulation), and FM (Frequency Modulation) Control. Analog dimming is controlled by adjusting forward current of Power LED. Although Analog dimming is possible to control linearly the brightness levels on a whole range (0%~100%), it comes into existence a variation of wavelength by changing the Power LED's forward current. PWM dimming has achieved by varying in duty of full current flowing to the Power LED. Generally, PWM dimming doesn't make variation of wavelength but have difficulty with adjusting the linear brightness level between 0% and 10%. FM dimming method is on the same wavelength as PWM dimming, however, it has problem of flickering at low level of dimming. This paper propose a efficient dimming control method of Power LED in order to overcome the disadvantages of the above mentioned methods. We apply to Analog method in low level of dimming control and use PWM method in dimming range from 10% to 100%. For the experiment, we design and implement a circuit and test the proposed method. Consequently, we can control the linear brightness of Power LED across the whole range and get the constant wave at different dimming level. The experimental results show the benefits of the proposed method.

Design of High-Speed Multi-Layer PCB for Ultra High Definition Video Signals (UHD급 영상구현을 위한 다층인쇄회로기판의 특성 임피던스 분석에 관한 연구)

  • Jin, Jong-Ho;Son, Hui-Bae;Rhee, Young-Chul
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.7
    • /
    • pp.1639-1645
    • /
    • 2015
  • In UHD high-speed video transmission system, when a signal within certain frequency region coincides electrically and structurally, the system becomes unstable because the energy is concentrated, and signal flux is interfered and distorted. For the instability, power integrity analysis should be conducted. To remove the signal distortion for MLB, using a high-frequency design technique for EMI phenomenon, EMI which radiates electromagnetic energy fluxed into power layer was analyzed considering system stabilization. In this paper, we proposed an adaptive MLB design method which minimizes high-frequency noise in MLB structure, enhances signal integrity and power integrity, and suppresses EMI. The characteristic impedance for multi-layer circuit board proposed in this study were High-Speed Video Differential Signaling(HSVDS) line width w = 0.203, line gap d = 0.203, beta layer height h = 0.145, line thickness t = 0.0175, dielectric constant εr = 4.3, and characteristic impedance Zdiff = 100.186Ω. When high-speed video differential signal interface board was tested with optimized parameters, the magnitude of Eye diagram output was 672mV, jittering was 6.593ps, transmission frequency was 1.322GHz, signal to noise was 29.62dB showing transmission quality improvement of 10dB compared to previous system.

Water-Level Fluctuation due to Groundwater-Surface Water Interaction in Coastal Aquifers (해안대수층에서 지하수-지표수 상호작용에 의한 지하수위 변화)

  • Kim Kue-Young;Lee Cheol-Woo;Kim Yongje;Kim Taehee;Woo Nam-Chil
    • Journal of Soil and Groundwater Environment
    • /
    • v.9 no.4
    • /
    • pp.32-41
    • /
    • 2004
  • Analysis of water-level fluctuation due to goundwater-surface water interaction in coastal aquifers is carried out by numerical modeling. The conceptual model used in this study has a stream boundary and a tidal boundary that forms a right angle and the stream partially penetrates the aquifer. We analyzed the effect of each boundary and the simultaneous effect of the two boundary conditions. The area of influence caused by the stream boundary increased during the simulation, while the influence zone of the coastal boundary was relatively constant. The groundwater level near the zone where two boundaries meet may rise by the action of combined effect of the two boundaries or may not change by cancelling the effect of each boundary. Thereafter, care must be taken when hydraulic parameters are estimated using sinusoidal oscillations of hydraulic head in coastal aquifers. Sensitivity analysis is employed to develop insight into the controls on groundwater level fluctuations. In this study our analyses focused on the effect of conductance and the stream width to the aquifer nearby.

Study on Wood Quality of Pinus koraiensis (6) - Characteristics of Woody Quality of Juvenile and Adult Wood - (잣나무의 재질(材質)에 관(關)한 연구(硏究)(제6보(第6報)) - 성열재(成熱材)와 미성열재(未成熱材)와의 재질(材質)의 특징(特徵) -)

  • Lee, Won-Yong;Kim, Su-Chang
    • Journal of the Korean Wood Science and Technology
    • /
    • v.10 no.1
    • /
    • pp.38-46
    • /
    • 1982
  • The research was carried out to determine the division of juvenile and adult wood from the pattern of variables of wood quality indicators, to investigate general low of the size of juwenile wood and to study the characteristics of juvenile and adult wood. For this study some trees of Pinus koraiensis were selected and several wood quality indicators such as annual ring width. late wood percentage, tracheid length tracheid diameter, wall thicknes, and microfibril angles were measured. The results of this study were summaried as follows. 1) Juvenile and adult wood can be divided into radial variations of wood quality indicators. In this study juvenile wood might be classified as a large fluctuated region of radial wood quality variations in the nearest part to pith. 2) Juvenile wood was indicated as a part of nearly cylinderical shape, averaging 6-11cm in radius, near pith. 3) Number of rings from pith of juvenile wood was about 12-20 and was nearly constant in uniform growth trees among the forest stands. 4) Usually adult wood was formed within the about 5-10m above ground.

  • PDF

Depth Dose Distribution of Proton Beams by Variation of Tumor Density using Geant4 (Geant4 전산모사를 이용한 종양의 밀도 변화에 따른 양성자의 선량 분포)

  • Kim, You-Me;Chon, Kwon-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.771-779
    • /
    • 2021
  • It is necessary to overlap several peaks to form spread out Bragg peak (SOBP) in order to cover the tumor volume because a mono-energetic proton beam forms a narrow Bragg peak. The tumor density has been considered as a brain tissue and then the absorbed dose of the tumor is calculated using Monte Carlo simulations. However, densities of tumors were not a constant. In this study, the SOBP of proton beams was calculated according to changing density of tumors by using Geant4. Tumors were selected as 10 mm and 20 mm width which were the treatment range in the brain phantom. The energies and relative weights of the proton beams were calculated using mathematical formula to form the SOBP suitable for the location and size of the tumor. As the density of the tumor was increased, the 95% modulation range and the practical range were decreased, and average absorbed dose in the 95% modulation range was increased. The change of the tumor density affects the dose distribution of the proton beams, which results in short SOBP within the tumor volume. The consideration of the tumor density affects the determination of the range, so that the margin of the treatment volume can be minimized, and the advantages of proton therapy can be maximized.

Free vibration of electro-magneto-thermo sandwich Timoshenko beam made of porous core and GPLRC

  • Safari, Mohammad;Mohammadimehr, Mehdi;Ashrafi, Hossein
    • Advances in nano research
    • /
    • v.10 no.2
    • /
    • pp.115-128
    • /
    • 2021
  • In this article, free vibration behavior of electro-magneto-thermo sandwich Timoshenko beam made of porous core and Graphene Platelet Reinforced Composite (GPLRC) in a thermal environment is investigated. The governing equations of motion are derived by using the modified strain gradient theory for micro structures and Hamilton's principle. The magneto electro are under linear function along the thickness that contains magnetic and electric constant potentials and a cosine function. The effects of material length scale parameters, temperature change, various distributions of porous, different distributions of graphene platelets and thickness ratio on the natural frequency of Timoshenko beam are analyzed. The results show that an increase in aspect ratio, the temperature change, and the thickness of GPL leads to reduce the natural frequency; while vice versa for porous coefficient, volume fractions and length of GPL. Moreover, the effect of different size-dependent theories such as CT, MCST and MSGT on the natural frequency is investigated. It reveals that MSGT and CT have most and lowest values of natural frequency, respectively, because MSGT leads to increase the stiffness of micro Timoshenko sandwich beam by considering three material length scale parameters. It is seen that by increasing porosity coefficient, the natural frequency increases because both stiffness and mass matrices decreases, but the effect of reduction of mass matrix is more than stiffness matrix. Considering the piezo magneto-electric layers lead to enhance the stiffness of a micro beam, thus the natural frequency increases. It can be seen that with increasing of the value of WGPL, the stiffness of microbeam increases. As a result, the value of natural frequency enhances. It is shown that in hc/h = 0.7, the natural frequency for WGPL = 0.05 is 8% and 14% less than its for WGPL = 0.06 and WGPL = 0.07, respectively. The results show that with an increment in the length and width of GPLs, the natural frequency increases because the stiffness of micro structures enhances and vice versa for thickness of GPLs. It can be seen that the natural frequency for aGPL = 25 ㎛ and hc/h = 0.6 is 0.3% and 1% more than the one for aGPL = 5 ㎛ and aGPL = 1 ㎛, respectively.

Leg Fracture Recovery Monitoring Simulation using Dual T-type Defective Microstrip Patch Antenna (쌍 T-형 결함 마이크로스트립 패치 안테나를 활용한 다리 골절 회복 모니터링 모의실험)

  • Byung-Mun Kim;Lee-Ho Yun;Sang-Min Lee;Yeon-Taek Park;Jae-Pyo Hong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.4
    • /
    • pp.587-594
    • /
    • 2023
  • In this paper, we present the design and optimization process of an on-body microstrip patch antenna with a paired T-type defect for monitoring fracture recovery of human legs. This antenna is designed to be light, thin and compact despite the improvement of return loss and bandwidth performance by adjusting the size of the T-type defect. The structure around the applied human leg is structured as a 5-layer dielectric plane, and the complex dielectric constant of each layer is calculated using the 4-pole Cole-Cole model parameters. In a normal case without bone fracture, the return loss of the on-body antenna is -66.71dB at 4.0196GHz, and the return loss difference ΔS11 is 37.95dB when the gallus layer have a length of 10.0mm, width of 1.0mme, and height of 2.0mm. A 3'rd degree polynomial is presented to predict the height of the gallus layer for the change in return loss, and the polynomial has a very high prediction suitability as RSS = 1.4751, R2 = 0.9988246, P-value = 0.0001841.

Histologic changes of tooth and periodontal tissues applying to contraction & intrusion force for the maxillary four incisors of dogs (성견 상악 4절치의 Contraction과 압하시 치아 및 주위 조직의 조직학적 변화에 관한 실험 연구)

  • Kim, Young-Kuk;Cha, Kyung-Suk;Lee, Jin-Woo
    • The korean journal of orthodontics
    • /
    • v.29 no.5 s.76
    • /
    • pp.535-549
    • /
    • 1999
  • The Purposes of this study were to investigate the initial tissue changes on the teeth and surrounding tissues under contraction and intrusive force by contraction UTA. A control and experimental dogs, 10-months in age, were studied. Contraction and intrusive force(60gm) were applied at upper four incisors by contraction UTA. Experimental dogs were sacrificed at 2 weeks and 4 weeks after force application, respectively. In this study, 2 experimental groups were designed by the duration of force applied(E1, E2). The specimens were taken around the upper first and second incisor in each groups and were prepared for the H-E and MT stain for light microscopic observation. From the results of the study, the following conclusions may be drown. : 1. In control group, the periodontal ligament width was constant from apical third to cervical third of the root and periodontal fiber arrangement was horizontal or oblique in cervical third, oblique in middle third and apical third. In alveolar bond, smooth appearance was shown with osteoblast. 2. In experimental group 1, in proportion to force was concentrated at labial middle third and apical third of root of the upper first and second incisors, root of these tooth tipped labially and intruded at a time. 3. In experimental group 2, periodontal ligament width and arrangement was similar to control and observed strong calcified response at the labial middle third of root. But, alveolar bond resorption and cementum resorption were as before seen at labial middle third and apical third of root that force was concentrated.

  • PDF

Comparison of shaping ability using various Nickel-Titanium rotary files and hybrid technique (다양한 전동 니켈 티타늄 파일과 혼합사용법에 의한 근관 성형 효율 비교)

  • Kim, Jung-Won;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.6
    • /
    • pp.530-541
    • /
    • 2007
  • Currently, various Nickel-Titanium rotary files are used in endodontic treatment, but there is no one perfect system that can be applied to any clinical situation. Therefore, the combined uses of various file systems which can emphasize the advantages of each system are introduced as hybrid instrumentation. The ProTaper system is efficient in body shaping and apical pre-enlargement but is reported to have more possibility of transportation and produce more aberrations and deformation in more or less severe curved canals. Recently, new ProTaper system(ProTaper Universal) with different configuration and cross-sectional design to overcome the week points of ProTaper have been marketed. The purpose of this study was to compare and evaluate the shaping abilities of ProTaper, ProTaper Universal system, and two hybrid methods using S-series of ProTaper Universal and Hero Shaper or ProFile. The time lapses for instrumentation were measured and the used files were inspected for distortion. The pre- and post-instrumented root canals were scanned and superimposed to evaluate the aberrations and reduction of root canal curvature and change of radius of canal curvature. The increased canal width and apical centering ratio were calculated at 1, 2, 3, 4 and 5 mm levels from apical foramen. Under the conditions of this study, the ProTaper Universal seems to have better shaping ability than ProTaper in terms of instrumented width and instrumentation time. It may be suggested that the ProTaper Universal system is efficient as much as hybrid instrumentation using ProTaper and other constant-tapered NiTi file systems in highly experienced operators.