• Title/Summary/Keyword: constant power

Search Result 2,851, Processing Time 0.027 seconds

Constant inversion black box model of EDFAs including various loss mechanisms (Loss mechanism을 고려한 밀도 반전이 고정된 EDFA의 black box 모델링에 대한 연구)

  • 민범기;이원재;박재형;박남규
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.3
    • /
    • pp.205-211
    • /
    • 2001
  • We propose a constant inversion black box model of erbium-doped fiber amplifiers (EDFAs) for exact performance predictions for EDFAs operated in the gain-flattened condition. The validity of the newly proposed model was experimentally verified by predicting the performance of EDFAs for the L band, within 1.9% required pump power discrepancy. The role of ion pairing effects on the power conversion efficiency is also discussed. ussed.

  • PDF

A Study on Shape Optimization of Electro-Magnetic Proportional Solenoid (비례솔레노이드 형상 최적설계에 관한 연구)

  • Yun S.N.;Ham Y.B.;Kang J.H.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.2 no.3
    • /
    • pp.1-5
    • /
    • 2005
  • There are two types of solenoid actuator for force and position control of the fluid power system. One is an on-off solenoid actuator and the other is an electro-magnetic proportional actuator. They have some different characteristics for attraction force according to solenoid shape. Attraction force of the on-off solenoid actuator only depends on flux density. And the stroke-force characteristics of the proportional solenoid actuator are determined by the shape of the control cone. In this paper, steady state characteristics of the solenoid actuator for electro-hydraulic proportional valve determined by the shape of control cone are analyzed using finite element method and it is confirmed that the proportional solenoid actuator has a constant attractive force in the control region independently on the stroke position. And the shape of control cone is optimized using 1+1 evolution strategy to get a constant force. In the optimization algorithm, control cone length, thickness and taper length are used as a design parameter.

  • PDF

Voltage Control of Stand-Alone Inverter for Power Quality Improvement Under Unbalanced and Non-linear Load (불평형 및 비선형부하 시 전력품질 향상을 위한 독립형 인버터의 전압제어 기법)

  • Lee, Wujong;Jo, Jongmin;Cha, Hanju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.4
    • /
    • pp.567-575
    • /
    • 2016
  • This paper proposed the voltage control of stand-alone inverter for power quality improvement under unbalanced and non-linear load. The 3-phase DC-AC inverter controls CVCF(Constant Voltage Constant Frequency) and selective harmonic eliminate method in stand-alone mode by PR controller, and the stand-lone inverter supplies stable sinusoidal voltage to balanced, unbalanced and non-linear loads. The total harmonic distortion(THD) of line-to-line load voltage($V_{LL}$) is 1.2% in the balanced load. THD of $V_{LL}$ is reduced from 5.2% to 1.4% and 6.7% to 3.5%, respectively unbalanced and non-linear load. The stand-alone inverter can be supplies sinusoidal balanced voltage to unbalanced load because the voltage unbalanced factor(VUF) of $V_{LL}$ is reduced from 5.2% to 1.4% in the unbalanced load. Feasibility of control method for a stand-alone inverter will be verified through 30kW stand-alone inverter system.

Experiment of Single-phase Grid Connected Battery Charger (5kW급 계통연계형 단상 배터리 충전기의 구현 및 실험)

  • An, Hyun-Sung;Lee, Wujong;Mun, Byung-Ho;Park, Il-Kyu;Jung, Seon-Yong;Kim, Youngroc;Cha, Hanju
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.84-90
    • /
    • 2013
  • This paper explains control methods of single-phase grid connected battery charger. Charging mode is control by Constant Current - Constant Voltage method and discharging mode is controlled by active-reactive power control method. Current control method is based on the synchronous reference frame(SRF) PI controller, and the second harmonic of battery current is compensated by an added L-C resonant circuit. Feasibility of the proposed control methods is verified through experiment with a prototype of 5kW single-phase grid connected battery charger.

Optimal Control of Fuel Cell Hybrid Vehicles (연료전지 하이브리드 자동차의 최적 제어)

  • Zheng, Chun-Hua;Park, Yeong-Il;Lim, Won-Sik;Cha, Suk-Won
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.2
    • /
    • pp.135-140
    • /
    • 2012
  • Fuel Cell Hybrid Vehicles (FCHVs) have already become the subject of major interest among automotive industry as well as power management strategies of FCHVs, as the fuel economy of FCHVs depends on them. There are several types of power management strategies of FCHVs that have been developed to improve the fuel economy of FCHVs. Among them, optimal control theory is applied to this study. A problem is defined and its objective is to minimize the energy consumption of an FCHV and to find the optimal trajectories of powertrain parameters during driving. Necessary conditions for the optimal control are introduced and the simulation results of constant costate are compared to that of variable costate in order to prove that the variable costate can be replaced with the constant costate.

IPMSM Drives Using NPC 3-Level Inverters for the Next Generation High Speed Railway System (NPC 3-레벨 인버터를 적용한 차세대 고속전철 IPMSM의 구동)

  • Kwon, Soon-Hwan;Jin, Kang-Hwan;Kim, Sung-Je;Lee, Tae-Houng;Kim, Yoon-Ho
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.2
    • /
    • pp.129-134
    • /
    • 2012
  • In this paper, speed control of IPMSM drives for the next generation domestic high speed railway system using NPC 3-level inverters is presented. The NPC multilevel inverter is suitable for the high-voltage and high-power motor drive system because it has advantages in that the voltage rating of the power semiconductor devices and output current harmonics are reduced. For the speed control of IPMSM using NPC 3-level inverters, maximum torque control is applied in the constant torque region, and filed weakening control is applied in the constant power region. Simulation programs based on MATLAB/Simulink are developed. Finally the designed system is verified and their characteristics are analyzed by the simulation results.

PEBB Based Bi-directional Rapid Charging System for EV Traction Battery

  • Kang, Taewon;Chae, Beomseok;Suh, Yongsug
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.323-324
    • /
    • 2013
  • This paper presents a simple and cost-effective stand-alone rapid battery charging system of 30kW for electric vehicles. The proposed system mainly consists of active front-end rectifier of neutral point clamped 3-level type and non-isolated bi-directional dc-dc converter of multi-phase interleaved half-bridge topology. The charging system is designed to operate for both lithium-polymer and lithium-ion batteries. The complete charging sequence is made up of three sub-interval operating modes; pre-charge mode, constant-current mode, and constant-voltage mode. The pre-charge mode employs the stair-case shaped current profile to accomplish shorter charging time while maintaining the reliable operation of the battery. The proposed system is specified to reach the full-charge state within less than 16min for the battery capacity of 8kWh by supplying the charging current of 78A. Owing to the simple and compact power conversion scheme, the proposed solution has superior module-friendly mechanical structure which is absolutely required to realize flexible power expansion capability in a very high-current rapid charging system.

  • PDF

Seismic Performance Evaluation of Seismically Isolated Nuclear Power Plants Considering Various Velocity-Dependent Friction Coefficient of Friction Pendulum System (마찰진자시스템의 마찰계수 변화에 따른 면진된 원전구조물의 거동특성 비교)

  • Seok, Cheol-Geun;Song, Jong-Keol
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.20 no.2
    • /
    • pp.125-134
    • /
    • 2016
  • In order to improve seismic safety of nuclear power plant (NPP) structures in high seismicity area, seismic isolation system can be adapted. In this study, friction pendulum system (FPS) is used as the seismic isolation system. According to Coulomb's friction theory, friction coefficient is constant regardless of bearing pressure and sliding velocity. However, friction coefficient under actual situation can be changed according to bearing pressure, sliding velocity and temperature. Seismic responses of friction pendulum system with constant friction and various velocity-dependent friction are compared. The velocity-dependent friction coefficients of FPS are varied between low-and fast-velocity friction coefficients according to sliding velocity. From the results of seismic analysis of FPS with various cases of friction coefficient, it can be observed that the yield force of FPS becomes larger as the fast-velocity friction coefficient becomes larger. Also, the displacement response of FPS becomes smaller as the fast-velocity coefficient becomes larger.

A Design and Experiment of Pressure and Shape Adaptive Mechanism for Detection of Defects in Wind Power Blade (풍력 발전용 블레이드 접합부의 결함 검출을 위한 일정가압 메커니즘 설계 및 실험)

  • Lim, Sun;Lim, Seung Hwan;Jeong, Ye Chan;Chi, Su Chung;Nam, Mun Ho
    • Journal of Applied Reliability
    • /
    • v.17 no.3
    • /
    • pp.224-235
    • /
    • 2017
  • Purpose: Reliability is the most important factor to detect defects as wind turbines are deployed in large blades. The methods of detecting defects are various, such as non-destructive inspection and thermal imaging inspection. We propose the phased array ultrasonic testing method of non-destructive testing. Methods: We propose the active pressure mechanism for wind power blade. The phase array ultrasonic inspection method is used for fault detection inner blade surface. Controlled pressure of mechanism with respect to z-axis is important for guarantee the result of phase array ultrasonic inspection. The model based control and proposed mechanism are utilized for overall system stability and effectiveness of system. Result: The result of proposed pressure mechanism B is more stable than A. Convergence speed is also faster than A. Conclusion: We confirmed the performance of the proposed constant pressure mechanism through experiments. Non-destructive testing was applied to the specimen to confirm the reliability of detecting defects.

Pulse Density Modulated Zero Voltage Soft-Switching High-Frequency Inverter with Single Switch for Xenon Gas Dielectric Barrier Discharge Lamp Dimming

  • Sugimura, Hisayuki;Suh, Ki-Young;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.391-394
    • /
    • 2006
  • This paper presents soft switching zero voltage switching high frequency inverter for rare gas fluorescent lamp using dielectric-barrier discharge phenomenon. The simple high-frequency inverter can completely achieve stable zero voltage soft switching (ZVS) commutation for wide its output power regulation ranges and load variations under its constant high frequency pulse density modulation (PDM) scheme. Its transient and steady state operating principle is originally described and discussed for a constant high-frequency PDM control strategy under a stable ZVS operation commutation, together with its output effective power regulation characteristics-based on the high frequency PDM strategy. The experimental operating performances of this high frequency Inverter are illustrated as compared with computer simulation results and experimental ones. Its light dimming characteristics due to power regulation scheme are evaluated and discussed on the basis of simulation and experimental results. The feasible effectiveness of this high frequency inverter appliance implemented here is proven from the practical point of view.

  • PDF