• Title/Summary/Keyword: constant power

Search Result 2,851, Processing Time 0.033 seconds

Measurement of Aerodynamic Properties of Screens for Windbreak Fence using the Apparatus for Testing Screens (공력 저항 측정기를 이용한 방풍펜스 방진막의 공기 투과 저항력 측정)

  • Kim, Rack-Woo;Lee, In-Bok;Hong, Se-Woon;Hwang, Hyun-Seob;Son, Young-Hwan;Kim, Tae-Wan;Kim, Min-Young;Song, Inhong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.55 no.6
    • /
    • pp.145-154
    • /
    • 2013
  • Recently, damage occurrence by wind erosion has been increasing in society. In times past, such problems only took place in desert area ; however, in recent years, the wind erosion problem is spreading out to agricultural land. Wind erosion in agricultural land can cause loss of loam soils, the disturbance of the photosynthesis of the crop fields and serious economic losses. To overcome the mentioned problems, installation of windbreak fence can be recommended which function as disturbing strong wind and wind erosion. However, there is still no proper guideline to install the windbreak fence and the installation used to rely on the intuition of the workers due to the lack of related studies. Therefore, this study measured the aerodynamic resistance of screens of the windbreak fence using the apparatus for testing screens. The apparatus for testing screens was designed to measure pressure loss around the screen. Measured pressure loss by wall friction compensated for pressure loss to calculate the aerodynamic resistance of screens. The result of pressure loss by regression analysis derived the aerodynamic coefficient of Darcy-Forchheimer equation and power law equation. The aerodynamic resistance was constant regardless of the overlapped shape when the screen was overlapped into several layers. Increasing the number of layers of the screen, internal resistance increased significantly more, and pressure loss caused by the screen also increased linearly when the wind speed was certain conditions, but permeability had no tendency. In the future, the results of this study will be applied to the computational fluid dynamics simulation. The simulation models will be also validated in advance by wind tunnel experiments. It will provide standard of a design for constructing windbreak fence.

The R-V Characteristics of $SiO_2 $ & $SiO_2/TiN$ Thin Film Fabricated by RF Sputtering (RF Sputtering으로 제작한 $SiO_2 $$SiO_2/TiN$ 박막의 R-V 특성)

  • 김창석;하충기;김병인
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.10
    • /
    • pp.826-832
    • /
    • 1998
  • In this study the thin films with the structure of Si+SiO$_2$+TiN are made by RF supttering method. TiN, which has small diffusion coefficient and low resistivity, is evaporated between SiO$_2$ and Al layers. It investigates the V-R characteristics depending on the thickness of SiO$_2$ which is used as insulation layer and researches its effects on voltage stability of thin film and varistor. These films show very small resistance valus in negative(-) voltage and large and large value in positive voltage band, and with the increase of voltage, resistance value is rapidly reduced and the satisfactory characteristic of varistor is shown at +1[V]. It is found that resistance value of TiN thin film is small and also TiN thin film has more current than the thin film which is not evaporated by TiN thin film. When Al electrode is evaporated of SiO$_2$ thin film, spiking occurs, but the spiking can be prevented with evaporation of TiN between SiO$_2$ and Al layers and this thin films in made easily because of its good attachment. With the increase of voltage, the resistance is changed into non-linear pattern and the bidirectional varistor characteristic is shown and then its theory can be verified by this experiment. Accordingly, when TiN is evaporated of Si Wafer(n-100), it obtains better voltage-resistance than thin film which is not evaporated and also when varistor character is used electrically to automatic control element such as elimination of flame, power distribution arrestor and constant voltage compensation, satisfactory reproducibilities are expected.

  • PDF

A Study on Development of a New Algorithm to Solve Load Flow for Distribution Systems (배전계통조류계산을 위한 새로운 알고리즘에 관한 연구)

  • Moon, Young-Hyun;Yoo, Sung-Young;Choi, Byoung-Kon;Ha, Bock-Nam;Lee, Joong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.918-922
    • /
    • 1998
  • With the development of industry, the qualitical advancement of power is needed. Since it is placed in the end step of power system, the fault at the distribution system causes some users blackout directly. So if the fault occurs, quick restoration is very important subject and, for the reason, induction of the distribution automation system is now being progressed briskly. For the quick restoration of the faulted distribution system, the load shedding of the blackout-area must be followed, and the other problems like the shedded load, faulted voltage and the rest may cause other accident. Accordingly load shedding must be based on the precise calculation technique during the distribution system load flow(dist flow) calculation. In these days because of its superior convergence characteristic the Newton-Raphson method is most widely used. The number of buses in the distribution system amounts to thousands, and if the fault occurs at the distribution system, the speed for the dist flow calculation is to be improved to apply to the On-Line system. However, Newton-Raphson method takes much time relatively because it must calculate the Jacobian matrix and inverse matrix at every iteration, and in the case of huge load, the equation is hard to converge. In this thesis. matrix equation is used to make algebraical expression and then to solve load flow equation and to modify above defects. Then the complex matrix is divided into real part and imaginary part to keep sparcity. As a result time needed for calculation diminished. Application of mentioned algorithm to 302 bus, 700 bus, 1004 bus system led to almost identical result got by Newton-Raphson method and showed constant convergence characteristic. The effect of time reduction showed 88.2%, 86.4%, 85.1% at each case of 302 bus, 700 bus system 86.4%, and 1004 bus system.

  • PDF

The Design and Characteristic Analysis of a Digital Signal Transmission System Based on Power Line Communications

  • Kim, Ji-Hyoung;Yun, Ji-Hun;Kim, Yong-K.;So, Byung-Moon
    • Transactions on Electrical and Electronic Materials
    • /
    • v.10 no.6
    • /
    • pp.222-226
    • /
    • 2009
  • The objective of this study is to share multimedia contents included in existing digital devices and to solve the problems of an increase in installation fees and non-environmentally friendly interiors. This study designed a new digital signal transmitter and receiver using power line transmission and HDMI in order to solve the problems in the existing systems. The transmitter and receiver designed in this study used an AD9867BCPZ PLC chip in which the transmission came from digital signals originating in a PC, and the system architecture was configured so that the outputs signals were connected to a TV from the receiver. The experiment was implemented by adding a Video Test Generator, a USBPre external sound card, and Smaart Live 6 for analyzing the characteristics of the configured system. In the video test results, it was verified that communication was actively implemented, and the image quality showed a constant level from the measurement of the captured video. In the case of the sound, it was verified that more than 90% of the sound signals were normally transmitted and received from the examination of their phases and magnitudes. Thus, the performance of the system designed in this study was verified, which leads to the resolution of some of the problems found in current digital devices.

Real-time model updating for magnetorheological damper identification: an experimental study

  • Song, Wei;Hayati, Saeid;Zhou, Shanglian
    • Smart Structures and Systems
    • /
    • v.20 no.5
    • /
    • pp.619-636
    • /
    • 2017
  • Magnetorheological (MR) damper is a type of controllable device widely used in vibration mitigation. This device is highly nonlinear, and exhibits strongly hysteretic behavior that is dependent on both the motion imposed on the device and the strength of the surrounding electromagnetic field. An accurate model for understanding and predicting the nonlinear damping force of the MR damper is crucial for its control applications. The MR damper models are often identified off-line by conducting regression analysis using data collected under constant voltage. In this study, a MR damper model is integrated with a model for the power supply unit (PSU) to consider the dynamic behavior of the PSU, and then a real-time nonlinear model updating technique is proposed to accurately identify this integrated MR damper model with the efficiency that cannot be offered by off-line methods. The unscented Kalman filter is implemented as the updating algorithm on a cyber-physical model updating platform. Using this platform, the experimental study is conducted to identify MR damper models in real-time, under in-service conditions with time-varying current levels. For comparison purposes, both off-line and real-time updating methods are applied in the experimental study. The results demonstrate that all the updated models can provide good identification accuracy, but the error comparison shows the real-time updated models yield smaller relative errors than the off-line updated model. In addition, the real-time state estimates obtained during the model updating can be used as feedback for potential nonlinear control design for MR dampers.

Numerical Study of the Effect of Fan Arrangement on the Cooling Performance of the ONAF Type Radiator for Power Transformer (변압기용 ONAF 방식 방열기의 팬 배치에 따른 냉각특성 연구)

  • Kim, Kuk-Kyeom;Suh, Yong Kweon;Kang, Sangmo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.4
    • /
    • pp.449-455
    • /
    • 2015
  • Owing to the trend of an increase in capacity and high-efficiency requirement, the life and reliability of power transformer depend significantly on the amount of heat generation per unit volume and the degradation of insulation oil. These problems can be solved by enhancing the cooling performance of the radiator. The purpose of this study was to find a suitable position of fans for a better cooling effect given by the forced-convection of air in an ONAF (Oil Natural Air Forced) type transformer. In the simulation, commercial software was used for flow analysis, and the cooling passage of the oil was simplified to shorten the time taken for computation. With the diameter of the fan fixed at a constant value, the analysis was performed only by changing the position of the fans. As a result, a vertical position change of the fans does not affect the cooling performance significantly. However, the temperature drop given by the fans positioned on the front region of the transformer is larger than that on the rear region.

Evaluation of Leak Rate Through a Crack with Linearly-Varying Sectional Area (선형적으로 변하는 단면적을 가진 균열에서의 누설률 평가)

  • Park, Jai Hak
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.9
    • /
    • pp.821-826
    • /
    • 2016
  • The leak before break (LBB) concept is used in pipe line design for nuclear power plants. For application of the LBB concept, leak rates through cracks should be evaluated accurately. Usually leak late analyses are performed for through-thickness cracks with constant cross-sectional area. However, the cross-sectional area at the inner pipe surface of a crack can be different from that at the outer surface. In this paper, leak rate analyses are performed for the cracks with linearly-varying cross-sectional areas. The effect of varying the cross-sectional area on leak rates was examined. Leak rates were also evaluated for cracks in bi-material pipes. Finally, the effects of crack surface morphology parameters on leak rates were examined.

A Study on Binary CDMA System Correlator Design for High-Speed Acquisition Processing (고속 동기 처리를 위한 Binary CDMA 시스템 코릴레이터 설계에 관한 연구)

  • Lee, Seon-Keun;Jeong, Woo-Yeol
    • Journal of the Korea Society of Computer and Information
    • /
    • v.12 no.1 s.45
    • /
    • pp.155-160
    • /
    • 2007
  • Because output of multi-code CDMA system adapted high speed data transmission becoming multi-level system use linear amplifier in output stage and complex output signal. Therefore, Multi-Code CDMA system has shortcoming of high price, high complexity etc.. Binary CDMA technology that allow fetters in existing CDMA technology to supplement this shortcoming proposed. In binary CDMA system When correlator process high speed data, bottle-neck phenomenon is happened on synchronization acquisition process, it is very important parameter. Because existent correlator must there be advantage that power consumption is small but flow addition of several stages to receive correlation's value, the processing speed has disadvantage because the operation amount is much. Therefore in this paper, proposed correlator has characteristic such as data is able to high speed processing, chip area is independent and power consumption is constant in structure in binary CDMA system.

  • PDF

Multi frequency band noise suppression system using signal-to-noise ratio estimation (신호 대 잡음비 추정 방법을 이용한 다중 주파수 밴드 잡음 억제 시스템)

  • Oh, In Kyu;Lee, In Sung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.35 no.2
    • /
    • pp.102-109
    • /
    • 2016
  • This paper proposes a noise suppression method through SNR (Singal-to Noise Ratio) estimation in the two microphone array environment of close spacing. The conventional method uses a noise suppression method for a gain function obtained through the SNR estimation based on coherence function from full band. However, this method cause performance decreased by the noise damage that affects all the feature vector component. So, we propose a noise suppression method that allocates a frequency domain signal into N constant multi frequency band and each frequency band gets a gain function through SNR estimation based on coherence function. Performance evaluation of the proposed method is shown by comparison with PESQ (Perceptual Evaluation of Speech Quality) value which is an objective quality evaluation method provided by the ITU-T (International Telecommunications Union Telecommunication).

Assessment of Academic Utilization of Online Information Resources by Undergraduate Students in University of Nigeria, Nsukka

  • Mole, Austin J.C.
    • International Journal of Knowledge Content Development & Technology
    • /
    • v.7 no.3
    • /
    • pp.29-48
    • /
    • 2017
  • The aim of this paper was to determine the utilization of online information resources by undergraduate students in the University of Nigeria, Nsukka. It was undertaken specifically with the objectives of identifying the online information resources used; academic purposes for their use, extent, problems and strategies for improving the academic use of the resources by undergraduate students. Descriptive survey was used as the research design. The population of this study comprises of all 25,657 regular registered undergraduate students in University of Nigeria, Nsukka. The sample for this study comprises 2500 students which is 10% of the population. The results of the study shows that most of the online information resources are not used by the undergraduate students. Just a few of them are highly used. Some of the academic purposes for the use of the resources include to do course assignment and project works and to stay up-to-date on social events. The major problems responsible for the low utilisation of the resources include incessant power failure, limited available computers in the university library, and server's low bandwidth. Based on the findings, maintenance of uninterrupted power supply, provision of enough computers in the library; constant upgrade of server's bandwidth and many more were recommended as the strategies for improving the use of online information resources by undergraduate students in UNN. The implication of this study lies in the fact that solutions to the problems raised would be helpful to the university management, librarians and students in ensuring maximum and adequate provision and effective utilisation of online information a resources in the library.