• Title/Summary/Keyword: constant power

Search Result 2,851, Processing Time 0.028 seconds

Design of Asymmetric Pre-swirl Stator for LNG Carrier according to Variation of Stator Shapes (날개의 형상 변화에 따른 LNG선용 비대칭 전류고정날개 설계)

  • Lee, Choel-Min;Shin, Yong-Jin;Kim, Moon-Chan;Choi, Jung-Eun;Chun, Ho-Hwan
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.53 no.1
    • /
    • pp.37-44
    • /
    • 2016
  • Recently researchers are conducting a lot of research related to EEDI in order to satisfy IMO resolution MEPC. Especially they are interested in design of energy saving device. This paper is to design the asymmetric pre-swirl stator for 160K LNG carrier in order to reduce energy. Two types of the asymmetric pre-swirl stator are taken into account; constant and variable pitch angle stators. “constant” and “variable” mean state that the pitch of stators change by radius. The dimensions of the stators are initially determined using potential-flow code. The propulsion performances of the stators are predicted using viscous-flow code. The model test is carried out in towing tank in PNU. Prediction of ship performance generally follow ITTC recommended. Ship wake prediction was done by two method, ITTC 1978 and ITTC 1999. Therefore propulsion performances were compared ITTC 1978 with ITTC 1999 methods. Comparison components are delivered power and thrust deduction coefficient of the model. Final pre-swirl stator is selected by comparing experiment and CFD.

A Study of Treatment Efficiency of Reflectors for CSOs Disinfection by Pulsed UV (Pulsed UV를 이용한 CSOs 소독시 반사체에 따른 처리효율 연구)

  • Han, Jonghun;Hur, Jiyong;Kim, Kangwook;Lee, Junyoung;Park, Wonseok;Lee, Jongyeol;Her, Namguk
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.1
    • /
    • pp.36-40
    • /
    • 2015
  • This study examined the disinfection in combined sewer overflows (CSOs) by pulsed ultraviolet (PUV). The reflectors (stainless steel. mirror, aluminium foil, aluminium (1050), aluminium (6061), aluminium (5052), and aluminium mirror) of PUV irradiation was performed in a 90 L stainless reactor at a constant temperature of $20^{\circ}C$ and an applied power of 4000 W. The reflection efficiency of reflectors were showed 1.00 (aluminium mirror) ~ 1.48 (aluminium foil) does. The case of a rough surface analysis using SEM showed high reflectance, was the case of a smooth surface and a low reflectivity. Pseudo first-order rate constant calculated results, has a higher reflectivity values were more than twice as high compared to the low reflectivity. Affected Total coliforms disinfection time, depending on the type of reflector is considered.

Creep characteristic of Mg alloy at high temperature (고온에서 마그네슘 합금의 크리이프 특성)

  • An, Jung-O;Park, Kyong-Do;Kwak, Jae-Seob;Kang, Dae-Min
    • 한국금형공학회:학술대회논문집
    • /
    • 2008.06a
    • /
    • pp.39-44
    • /
    • 2008
  • Magnesium alloys have given high attention to the industry of light-weigh as automobile and electronics with aluminium, titanium and composite alloys due to their high strength, low specific density and good damping characteristics. But the magnesium contained structures under high temperature have the problems related to creep deformation and rupture life, which is a reason of developing the new material against creep deformation to use them safely. The purpose of this study is to predict the creep deformation mechanism and rupture time of AZ31 magnesium alloy. For this, creep tests of AZ31 magnesium alloy were done under constant creep load and temperature with the equipment including automatic temperature controller with acquisition computer. The apparent activation energy Qc and the applied stress exponent n, rupture life have been determined during creep of AZ31 Mg alloy over the temperature range of $150^{\circ}C$ to $300^{\circ}C$. In order to investigate the creep behavior. Constant load creep tests were carried out in the equipment including automatic temperature controller, whose data are sent to computer. At around the temperature of $150^{\circ}C{\sim}300^{\circ}C$ the creep behavior obeyed a simple power-law relating steady state creep rate to applied stress and the activation energy for the creep deformation was nearly equal and a little low, respectively, to that of the self diffusion of Mg alloy.

  • PDF

A Study on the Condensation Heat Transfer and Pressure Drop in Internally Grooved Tubes Used in Condenser (응축기용 낮은 핀관의 내부 나선 홈에 의한 응축 열전달 성능과 압력손실에 관한 연구)

  • Han, Kyuil;Cho, Dong-Hyun
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.34 no.2
    • /
    • pp.212-222
    • /
    • 1998
  • Heat transfer performance improvement by fin and groovs is studied for condensation of R-11 on integral-fin tubes. Eight tubes with trapczodially shaped integral-fins having fin density from 748 to 1654fpm(fin per meter) and 10, 30 grooves are tested. A plain tube having the same diameter as the finned tubes is also used for comparison. R-11 condensates at saturation state of 32 $^{\circ}C$ on the outside tube surface coded by inside water flow. All of test data are taken at steady state. The heat transfer loop is used for testing singe long tubes and cooling is pumped from a storage tank through filters and folwmeters to the horizontal test section where it is heated by steam condensing on the outside of the tubes. The pressure drop across the test section is measured by menas pressure gauge and manometer. The results obtained in this study is as follows : 1. Based on inside diameter and nominal inside area, overall heat transfer coefficients of finned tube are enhanced up to 1.6 ~ 3.7 times that of a plain tube at a constant Reynolds number. 2. Friction factors are up to 1.6 ~ 2.1 times those of plain tubes. 3. The constant pumping power ratio for the low integral-fin tubes increase directly with the effective area to the nominal area ratio, and with the effective area diameter ratio. 4. A tube having a fin density of 1299fpm and 30 grooves has the best heat transfer performance.

  • PDF

A Kinetic Study on the Growth of Nanocrystalline Diamond Particles to Thin Film on Silicon Substrate

  • Jung, Doo-Young;Kang, Chan-Hyoung
    • Journal of Surface Science and Engineering
    • /
    • v.44 no.4
    • /
    • pp.131-136
    • /
    • 2011
  • A kinetic study has been made for the growth of nanocrystalline diamond (NCD) particles to a continuous thin film on silicon substrate in a microwave plasma chemical vapor deposition reactor. Parameters of deposition have been microwave power of 1.2 kW, the chamber pressure of 110 Torr, and the Ar/$CH_4$ ratio of 200/2 sccm. The deposition has been carried out at temperatures in the range of $400\sim700^{\circ}C$ for the times of 0.5~16 h. It has been revealed that a continuous diamond film evolves from the growth and coalescence of diamond crystallites (or particles), which have been heterogeneously nucleated at the previously scratched sites. The diamond particles grow following an $h^2$ = k't relationship, where h is the height of particles, k' is the particle growth rate constant, and t is the deposition time. The k' values at the different deposition temperatures satisfy an Arrhenius equation with the apparent activation energy of 4.37 kcal/mol or 0.19 eV/ atom. The rate limiting step should be the diffusion of carbon species over the Si substrate surface. The growth of diamond film thickness (H) shows an H = kt relationship with deposition time, t. The film growth rate constant, k, values at the different deposition temperatures show another Arrhenius-type expression with the apparent activation energy of 3.89 kcal/mol or 0.17 eV/atom. In this case, the rate limiting step might be the incorporation reaction of carbon species from the plasma on the film surface.

A Study on the Electrical and Optical Characteristics of CLN-PZT Ceramics (CLN-PZT 세라믹스의 전기, 광학 특성에 관한 연구)

  • Kang, Won-Koo
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.799-801
    • /
    • 1988
  • This paper was studied on the effects of Ca-La-Nb substitution and Zr/Ti ratio variation to Pb(Zr, Ti)$O_3$ system on structural, electrical, optical and sound level characteristics in order to develope the piezoelectric and electrooptic ceramic devices. Also the specimens were prepared by the two stage sintering technique. The molecular formular was X($CaO{\cdot}1/4La_{2}O_{3}{\cdot}1/4Nb_{2}O_{5}){\cdot}(1-X)Pb(Zr_{Y}Ti_{1-Y})O_{3}$(x=100X, y=100Y), and the variation of x was $6{\sim}12$, y was 60${\sim}$49 and second stage sintering time was 20${\sim}$40 hours. The experimental results obtained from this study are as follows : 1. The density was decreased, the grain size was increased according to increase of Ca-La-Nb substitution. 2. The crystal structure was rhombohedral in composition 6/60/40, and the crystal structure was tetragonal and cubic according to increase of Ca-La-Nb substitution. 3. The Ca substitution of PZT system enhanced the sintering property. The Pb site vacancy resulting from the substitution of La-Nb increased the dielectrical constant, the piezoelectric charge constant, the dielectric loss and decreased the coercive field. 4. The resistivity of PZT system which has the P type conduction mechanism increased according to substitution of La-Nb because of the substituent acting as donor. 5. The PZT ceramics varied from ferroelectric substance according to increase of Ca-La-Nb substituent. The coercive field and saturation remanent polarization decreased, and at last straight line according to increase of La-Nb substitution. 6. The amount of Ca-La-Nb substitution to improve the light transmittance of speciment was 10 mol%, the Zr/Ti ratio was 49/51, and the second stage sintering time was 40 hours. 7. According to Ca-La-Nb substitution, the specimens was to be transparent. The 7.5/51/49 specimen was suitable for transparent sound vibrator because it had 58% light transmittance (thick 0.2[mm], wave length 700[mm]) and 48% electromechanical coupling factor.

  • PDF

Development and Construction of low Magnetic Field Control System for Analysis of Magnetic Field Effect in the Deflection Yoke (브라운관의 자기장 영향 분석용 저자기장 제어 장치의 설계 및 제작)

  • Park, Po-Gyu;Kim, Young-Gyun;Shin, Suk-Woo;Choi, Hyung-Ho;Kim, Tae-Ik;Jung, Dong-Keun
    • Journal of the Korean Magnetics Society
    • /
    • v.13 no.6
    • /
    • pp.251-256
    • /
    • 2003
  • We have developed the quality analysis system for magnetic field effect of cathode-ray tube that is used a monitor, TV and medical appliance. We designed and constructed the large 3-axis square coil (2 m length) system for the generation of 3-component magnetic field using power supply, magnetometer and computer below 0.2 mT range. The coil constant is 30.31 ${\mu}$T, 29.73 ${\mu}$T and 30.51 ${\mu}$T for the X, Y and Z axis square coil respectively. The magnetic field resolution was 0.01 T. The uniformity of magnetic field was measured within 1 % in the range of 12 cm.

Reliability Analysis of Multi-functional Multi-state Standby System Using Weibull Distribution (와이블 분포를 이용한 다기능 다중상태 대기시스템의 신뢰도 분석)

  • Kim, Ji-Hye;Chung, Young-Bae
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.40 no.3
    • /
    • pp.138-147
    • /
    • 2017
  • As the functions and structure of the system are complicated and elaborated, various types of structures are emerging to increase reliability in order to cope with a system requiring higher reliability. Among these, standby systems with standby components for each major component are mainly used in aircraft or power plants requiring high reliability. In this study, we consider a standby system with a multi-functional standby component in which one standby component simultaneously performs the functions of several major components. The structure of a parallel system with multifunctional standby components can also be seen in real aircraft hydraulic pump systems and is very efficient in terms of weight, space, and cost as compared to a basic standby system. All components of the system have complete operation, complete failure, only two states, and the system has multiple states depending on the state of the component. At this time, the multi-functional standby component is assumed to be in a non-operating standby state (Cold Standby) when the main component fails. In addition, the failure rate of each part follows the Weibull distribution which can be expressed as increasing type, constant type, and decreasing type according to the shape parameter. If the Weibull distribution is used, it can be applied to various environments in a realistic manner compared to the exponential distribution that can be reflected only when the failure rate is constant. In this paper, Markov chain analysis method is applied to evaluate the reliability of multi-functional multi-state standby system. In order to verify the validity of the reliability, a graph was generated by applying arbitrary shape parameters and scale parameter values through Excel. In order to analyze the effect of multi-functional multi-state standby system using Weibull distribution, we compared the reliability based on the most basic parallel system and the standby system.

The UV LED Bar Optimal Design with Human Detection and Control Function (인체 감지 제어 기능을 갖는 UV LED Bar의 최적 설계)

  • Kim, Chang-Sun;Lee, Jae-Hak;Goh, Young-Jin
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.6
    • /
    • pp.1219-1226
    • /
    • 2017
  • In this paper, it is performed the optimal design of the UV LED bar which can be used variously. The UV LED Bar emits ultraviolet rays, so it is important to emit ultraviolet rays constantly for the purpose of use. In order to emit a certain amount of ultraviolet rays as ever, the ultraviolet ray emission should be driven by a constant current source within the operable input voltage range. And also the heat dissipation is particularly important because of the long ultraviolet emission retention time due to the UV utilization characteristics. In addition, since human body protection is essential, the algorithm is configured to operate according to human body detection using distance sensor and Bluetooth. Three 365nm UV LEDs were used in series to emit ultraviolet UVA, operating at the constant current of 500mA with an efficiency of 87.5% and a power consumption of 6.006W. The ultraviolet radiation dose was measured at $5.35mW/cm^2$ at the distance of 10 cm when measured by the Lutron ultraviolet measuring instruments.

Analysis and signal stability measurement for DGPS radio wave propagation (DGPS 전파 신호의 안정도 측정 및 분석)

  • Kim, Young-wan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.2
    • /
    • pp.231-236
    • /
    • 2016
  • The stability of DGPS signal in the DGPS service area was measured and the service availability according to the receiving signal strength was analyzed in this paper. Based on the effects of radio wave propagation in the seasons of winter and summer, daytime and night, the method to provide the DGPS service coverage was presented in this paper. The signal's strength of DGPS radio wave were measured at a constant distance from the DGPS reference station during a constant period. The propagation of DGPS radio wave is affected by status of ground conductivity, so the DGPS service area is dependant on the ground conductivity. To provide the stable service coverage, it is necessary to apply the adaptive power control for receiving signal's variations and the antenna design for alleviation of high elevation's radiation.