• Title/Summary/Keyword: constant power

Search Result 2,851, Processing Time 0.029 seconds

Residual Stress Measurement on T-type Welded Specimen by Neutron Diffraction

  • Jang, D.Y.;Park, M.J.;Choi, H.D.;Kim, J.P.
    • International Journal of Korean Welding Society
    • /
    • v.1 no.2
    • /
    • pp.45-50
    • /
    • 2001
  • This paper presents application of neutron diffraction technique to the measurement of residual stresses in the T-type 20 m thick welded stainless steel plates(100$\times$50 $mm^2$ and 50$\times$50 $mm^2$). The High Resolution Powder Diffractormeter of the Korea Atomic Research Institute was utilized in the measurement. The power of nuclear reactor was 24 MWt and the measured reflection in the 220 plane (2$\theta$)was $92.66^{\circ}$. Poisson ratio of 0.265 and elastic constant of 211 GPa were applied to the calculation of stresses and strains. Three directional components such as normal, transverse, and longitudinal stresses were measured. The results showed that three components were tensile and became compressive along the y axis in the zone away from the welded center. The compressive stresses became tensile in the zone away from the center line of x axis. This may be due to the balance effect caused by the net stress to keep the specimen shape flat.

  • PDF

Residual Stress Measurement on Welded Stainless Steel Specimen by Neutron Diffraction

  • Park, M.J.;Jang, D.Y.;Choi, H.D.
    • International Journal of Korean Welding Society
    • /
    • v.1 no.1
    • /
    • pp.39-43
    • /
    • 2001
  • In this paper, the neutron diffraction is applied to the residual stress measurement on the 20mm-thick welded stainless steel plate ($100^{\circ}$$\times$100$mm^2$). The High Resolution Powder Diffractormeter of the Korea Atomic Research Institute The power of nuclear reactor was 24 MWt and the measured reflection in the 220 plane (2$\theta$ is $95^{\circ}$and wavelength is 1.8340 ${\AA}$ . The Poisson ratio of 0.265 and elastic constant of 211 GPa are applied to the calculation of stresses and strains. Three directional components such as normal, transverse, and longitudinal stresses are measured and the results show that the most of longitudinal stress is tensile and decreases, changing to compressive depending on the distance away from the welded spot. However, transverse component is changing from tensile to compressive along the depth of the welded point.

  • PDF

A Study on the Performance of a Shell Tube Heat- Exchanger with Twisted Tape (비틀림 테이프에 의한 이중관형 열교환기의 성능에 관한 연구)

  • Kim, Doo-Chun;Kim, Chul-Han
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.11 no.2
    • /
    • pp.1-9
    • /
    • 1982
  • Friction losses and heat transfer characteristics were studied experimentally for fully developed tubulent flow in tubes with twisted tape swirl generators. Data were obtained for pitch- to-diameter ratios from 8.10 to 25.71 with water under forced convection cool ins conditions. The experimental results of this and that of previous swirl flow investigation by Smithberg and Landis were compared. Nusselt number and friction data are combined in a constant pumping power comparision for swirl and straight flow, which indicates that improvement of 2.0 times in the best performance can be obtained with twisted tape-insert tube. A twisted tape-insert tube is recommended in the case of low temperature difference in heat-exchanger.

  • PDF

Braking Pressure Characteristics of Solenoid-Flow Control Type ABS by PWM Control (PWM 제어에 의한 솔레노이드-유량제어방식 ABS의 제동압력 특성)

  • Song, Chang-Seop;Yang, Hae-Jeong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.8
    • /
    • pp.146-154
    • /
    • 1997
  • Solenoid-folw control type ABS is used with a 'dump and reapply' pressure control arrangement instead of using 2/2 (normal open/close) solenoid valves in convensional systems(sol. -sol. control type), a flow control valve is used which replaces the (no) inlet valve. The flow control valve controls fluid flow providing a nearly constant reapply rate( .theta. ) after the dump plase of ABS operation. In this study, to investigate a characteristics of brake pressure by PWM control, test rig was consisted of ABS hydraulic modulator, digital controller, pneumatic power supply and brake master cylinder. For comparison with experi- mental results, system modelling and computer simulation were performed. As a result, experiment results showed fairly agreement with the simulation. Also, it is shown that the pressure gradient (tan .theta. ) is affected by pressure, frequency, duty ratio and expressed with an exponential funtion.

  • PDF

Severe Temporal Hyper-Activated States Caused by Noise in Tinnitus and Hyperacusis with Normal Hearing

  • Bae, Eun Bit;Lee, Jun Ho
    • Korean Journal of Audiology
    • /
    • v.23 no.3
    • /
    • pp.160-166
    • /
    • 2019
  • Lots of neuroimaging and animal studies have revealed that tinnitus and hyperacusis share the same patterns in the bottom up central auditory process. The aim was to identify the abnormal central patterns commonly observed in both tinnitus and hyperacusis in humans. We investigated two cases of normal hearing: a tinnitus patient and a hyperacusis patient. We compared the differences between the severe temporal hyper-activated state (STHS), with spikes, fast beta and gamma frequencies after noise exposure, and the mild temporal hyperactivated state (MTHS), in no sound exposed condition. The power of the gamma band in the two cases was increased in both auditory cortices compared to the other brain regions. Our results of human with normal hearing were the first to identify how tinnitus and hyperacusis caused by sound are abnormally active and how they maintain constant pathological states.

Heat generation characteristics of the heating mortar according to repeated electricity supply (반복전기공급에 따른 발열모르타르의 발열 특성)

  • Kim, Young-Min;Lim, Chang-Min;Gwon, Hyeon-U;Lee, Gun-cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.170-171
    • /
    • 2022
  • In recent years, due to the occurrence of traffic accidents caused by black ice in winter, the number of personal injuries is increasing rapidly. Black ice is a phenomenon that occurs like a thin layer of ice on the road surface. Accordingly, many developments of heat-generating concrete are being developed to remove ice by increasing the temperature by supplying constant electricity to places where black ice is likely to occur. These heating elements are being developed by mixing a conductive material represented by carbon nanotubes with concrete. However, research up to now has been focused on efficient temperature rise and derivation of the optimum mixing ratio, and the evaluation of maintaining heat generation performance during continuous repetition is insufficient. Therefore, in this study, a heating test specimen was manufactured and 50V power was repeatedly supplied to evaluate the heating characteristics.

  • PDF

Severe Temporal Hyper-Activated States Caused by Noise in Tinnitus and Hyperacusis with Normal Hearing

  • Bae, Eun Bit;Lee, Jun Ho
    • Journal of Audiology & Otology
    • /
    • v.23 no.3
    • /
    • pp.160-166
    • /
    • 2019
  • Lots of neuroimaging and animal studies have revealed that tinnitus and hyperacusis share the same patterns in the bottom up central auditory process. The aim was to identify the abnormal central patterns commonly observed in both tinnitus and hyperacusis in humans. We investigated two cases of normal hearing: a tinnitus patient and a hyperacusis patient. We compared the differences between the severe temporal hyper-activated state (STHS), with spikes, fast beta and gamma frequencies after noise exposure, and the mild temporal hyperactivated state (MTHS), in no sound exposed condition. The power of the gamma band in the two cases was increased in both auditory cortices compared to the other brain regions. Our results of human with normal hearing were the first to identify how tinnitus and hyperacusis caused by sound are abnormally active and how they maintain constant pathological states.

Thermal buckling of porous FGM plate integrated surface-bonded piezoelectric

  • Mokhtar Ellali;Khaled Amara;Mokhtar Bouazza
    • Coupled systems mechanics
    • /
    • v.13 no.2
    • /
    • pp.171-186
    • /
    • 2024
  • In the present paper, thermal buckling characteristics of functionally graded rectangular plates made of porous material that are integrated with surface-bonded piezoelectric actuators subjected to the combined action of thermal load and constant applied actuator voltage are investigated by utilizing a Navier solution method. The uniform temperature rise loading is considered. Thermomechanical material properties of FGM plates are assumed to be temperature independent and supposed to vary through thickness direction of the constituents according to power-law distribution (P-FGM) which is modified to approximate the porous material properties with even and uneven distributions of porosities phases. The governing differential equations of stability for the piezoelectric FGM plate are derived based on higher order shear deformation plate theory. Influences of several important parameters on the critical thermal buckling temperature are investigated and discussed in detail.

Thermoelastic analysis of rotating FGM thick-walled cylindrical pressure vessels under bi-directional thermal loading using disk-form multilayer

  • Fatemeh Ramezani;Mohammad Zamani Nejad
    • Steel and Composite Structures
    • /
    • v.51 no.2
    • /
    • pp.139-151
    • /
    • 2024
  • In this research, a semi-analytical solution is presented for computing mechanical displacements and thermal stresses in rotating thick cylindrical pressure vessels made of functionally graded material (FGM). The modulus of elasticity, linear thermal expansion coefficient, and density of the cylinder are assumed to change along the axial direction as a power-law function. It is also assumed that Poisson's ratio and thermal conductivity are constant. This cylinder was subjected to non-uniform internal pressure and thermal loading. Thermal loading varies in two directions. The governing equations are derived by the first-order shear deformation theory (FSDT). Using the multilayer method, a functionally graded (FG) cylinder with variable thickness is divided into n homogenous disks, and n sets of differential equations are obtained. Applying the boundary conditions and continuity conditions between the layers, the solution of this set of equations is obtained. To the best of the researchers' knowledge, in the literature, there is no study carried out bi-directional thermoelastic analysis of clamped-clamped rotating FGM thick-walled cylindrical pressure vessels under variable pressure in the longitudinal direction.

Failure simulation of nuclear pressure vessel under severe accident conditions: Part II - Failure modeling and comparison with OLHF experiment

  • Eui-Kyun Park;Jun-Won Park;Yun-Jae Kim;Yukio Takahashi;Kukhee Lim;Eung Soo Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.11
    • /
    • pp.4134-4145
    • /
    • 2023
  • This paper proposes strain-based failure model of A533B1 pressure vessel steel to simulate failure, followed by application to OECD lower head failure (OLHF) test simulation for experimental validation. The proposed strain-based failure model uses simple constant and linear functions based on physical failure modes with the critical strain value determined either using the lower bound of true fracture strain or using the average value of total elongation depending on the temperature. Application to OECD Lower Head Failure (OLHF) tests shows that progressive deformation, failure time and failure location can be well predicted.