• Title/Summary/Keyword: constant power

Search Result 2,851, Processing Time 0.035 seconds

760 V-Class DC Switch Breaking Characteristics Using Tandem Type Magnet Extinguisher (탠덤형 자석 소호기를 사용한 760V급 직류 개폐기의 차단 특성)

  • Kim, Hyosung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.3
    • /
    • pp.175-179
    • /
    • 2022
  • Magnetic arc extinguishing technology is effective as an extinguishing device for low-voltage direct current (DC) circuit breakers with a resistive load of ≤4 kW. The separation distance between the magnet and the electrical contact must be shortened to increase the magnetic arc extinguishing force. However, if the magnet is installed too close to the electrical contact points, the magnet is exposed to high temperatures due to the arc current generated when the load current is cut off and the magnetism is lost. To solve this problem, the effective magnetic flux density at the electrical contact can be maintained high by placing the arc extinguishing magnet in a tandem structure with the electrical contact point between them, and the proper separation distance between the contact points and the magnet can be maintained. In addition, an electric arc extinguishing technology that emits arc energy using a series circuit of diode and resistor is used to suppress the continuous arc voltage generated by the inductive load. For the proposed circuit breaker, the breaking characteristics are analyzed through the breaking test for the DC load of the 760 V level, the load power of 4 kW, and the time constant of 5 ms, and an appropriate arc extinguishing design guideline is proposed.

A Control Strategy of Auto-Leveling Equipment of Multi-Function Radar for Vehicle based on Embedded System Modeling

  • Byeol Han;Yushin Chang;Sungyong Lee
    • Journal of the Korea Society of Computer and Information
    • /
    • v.28 no.9
    • /
    • pp.1-8
    • /
    • 2023
  • This paper presents the control strategy of Auto-leveling equipment (ALE) of Multi-function radar (MFR) for vehicle using Embedded System. MFR implements surveillance patrol missions such as surface-to-air missiles and fighters with constant rotation. ALE consists of 4 Auto-leveling modules (ALM) and retains the stability with maintaining level. The gradient of vehicle can be measured and controlled by embedded systems. This paper contributes for improvement the system design with the ALM 1 set modeling. The validity of the modeling is verified using MATLAB/Simulink.

Tailoring Surface Properties of Polyimides by Laser Direct Patterning (레이저 직접 패터닝에 의한 폴리이미드의 표면 특성 제어)

  • Yun Chan Hwang;Jeong Min Sohn;Jae Hui Park;Ki-Ho Nam
    • Textile Coloration and Finishing
    • /
    • v.35 no.2
    • /
    • pp.121-127
    • /
    • 2023
  • In this study, a comprehensive investigation was conducted on the morphological and property changes of laser-induced nanocarbon (LINC) as a function of laser process parameters. LINC was formed on the surfaces of polyimide films with different backbone structures under various process conditions, including laser power, scan speed, and resolution. Three different forms of LINC electrodes (i.e., continuous 3D porous graphene, wooly nanocarbon fibers, line cut) were formed depending on the laser power and scan speed. Furthermore, heteroatom doping induced from the chemical structure of the polyimide during laser patterning was found to be effective in modifying the electrical properties of LINC electrodes. The LINC surfaces exhibited different microstructures depending on the laser beam resolution under constant laser power and scan speed, allowing for controllable surface wettability. The correlation between the chemical structure of the polymer substrate, laser process parameters, and carbonized surface properties in this study is expected to be utilized as fundamental understanding for the manufacturing of next-generation carbon-based electronic devices.

Design of DC-DC Buck Converter Using Micro-processor Control (마이크로프로세서 제어를 이용한 DC-DC Buck Converter 설계)

  • Jang, In-Hyeok;Han, Ji-Hun;Lim, Hong-Woo
    • Journal of Advanced Engineering and Technology
    • /
    • v.5 no.4
    • /
    • pp.349-353
    • /
    • 2012
  • Recently, Mobile multimedia equipments as smart phone and tablet pc requirement is increasing and this market is also being expanded. These mobile equipments require large multi-media function, so more power consumption is required. For these reasons, the needs of power management IC as switching type dc-dc converter and linear regulator have increased. DC-DC buck converter become more important in power management IC because the operating voltage of VLSI system is very low comparing to lithium-ion battery voltage. There are many people to be concerned about digital DC-DC converter without using external passive device recently. Digital controlled DC-DC converter is essential in mobile application to various external circumstance. This paper proposes the DC-DC Buck Converter using the AVR RISC 8-bit micro-processor control. The designed converter receives the input DC 18-30 [V] and the output voltage of DC-DC Converter changes by the feedback circuit using the A/D conversion function. Duty ratio is adjusted to maintain a constant output voltage 12 [V]. Proposed converter using the micro-processor control was compared to a typical boost converter. As a result, the current loss in the proposed converter was reduced about 10.7%. Input voltage and output voltage can be displayed on the LCD display to see the status of the operation.

Repair of Large to Massive Rotator Cuff Tears in the Elderly Patients (65세 이상 고령 환자의 대형 및 광범위 회전근 개 파열에 대한 봉합술)

  • Jung, Hong Jun;Chun, Jae Myeung;Jeon, In-Ho;Kwon, Jun;Ha, Sang-Ho;Yang, Sung Wook;Lee, Ji-Ho
    • Clinics in Shoulder and Elbow
    • /
    • v.15 no.2
    • /
    • pp.91-98
    • /
    • 2012
  • Purpose: The objective of this study is to evaluate the functional outcome and identify prognosis of retear patients in patients aged 65 years or over undergoing surgical repair for a large to massive full-thickness rotator cuff tear. Materials and Methods: From 1995 September to 2010 March, 147 patients aged 65years or over (40 male, 107 female, with an average age of 69.6) undergoing surgical repair for large to massive full thickness rotator cuff tear (large 67 cases, massive 80 cases). For functional evaluation, preoperative and postoperative 1 year range of motion and muscle power checked. For subjective evaluation, American shoulder and elbow surgeons score and Constant score were checked. For anatomical evaluation, 87 patients were checked shoulder MRI at the time of the postoperative 1 year. Results: ASES score improved from to 50.4 to 88.9, Constant score improved from 47.1 to 75.2. Supraspinatus power improved from 51.1% to 80.8%, external rotator muscle power improved from 64.5% to 83.1%. Forward elevation improved from 117.4 degrees to 153 degrees, external rotation improved from 23.6 degrees to 41.8 degrees. Follow up MRI showed re-tear in 23%, all re-tear patients were from massive tear except one patient. All re-tear patients showed improved clinical outcomes, but supraspinatus and external rotator muscle power were not improved. Conclusions: Patients aged 65 years or over undergoing surgical repair for a large to massive full-thickness rotator cuff tear showed successful outcomes over 90 percent. Re-tear patients also showed successful clinical outcomes. In elderly patients with large to massive full thickness rotator cuff tear, aggressive surgical repair leads good clinical outcomes.

A Study on the Efficiency Improvement Method of Photovoltaic System Using DC-DC Voltage Regulator (DC-DC 전압 레귤레이터를 이용한 태양광전원의 효율향상 방안에 관한 연구)

  • Tae, Donghyun;Park, Jaebum;Kim, Miyoung;Choi, Sungsik;Kim, Chanhyeok;Rho, Daeseok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.704-712
    • /
    • 2016
  • Recently, the installation of photovoltaic (PV) systems has been increasing due to the worldwide interest in eco-friendly and infinitely abundant solar energy. However, the output power of PV systems is highly influenced by the surrounding environment. For instance, a string of PV systems composed of modules in series may become inoperable under cloudy conditions or when in the shade of a building. In other words, under these conditions, the existing control method of PV systems does not allow the string to be operated in the normal way, because its output voltage is lower than the operating range of the grid connected inverter. In order to overcome this problem, we propose a new control method using a DC-DC voltage regulator which can compensate for the voltage of each string in the PV system. Also, based on the PSIM S/W, we model the DC-DC voltage regulator with constant voltage control & MPPT (Maximum Power Point Tracking) control functions and 3-Phase grid connected inverter with PLL (Phase-Locked Loop) control function. From the simulation results, it is confirmed that the present control method can improve the operating efficiency of PV systems by compensating for the fluctuation of the voltage of the strings caused by the surrounding conditions.

Single and Double-row Repair in Rotator Cuff Tears (회전근 개 파열의 일열 봉합술과 이열 봉합술)

  • Park, Jin-Young;Choi, Jin-Hyung;Park, Hong-Keun;Yu, Je-Wook;Seo, Joong-Bae
    • Clinics in Shoulder and Elbow
    • /
    • v.9 no.1
    • /
    • pp.89-95
    • /
    • 2006
  • Purpose: Arthroscopic repair of rotator cuff tears are many techniques that have been developed to improve the initial postoperative strength of the repair. There was a doubt that current arthroscopic cuff repairs using a single row of suture anchors reproduce insufficient area of the anatomic cuff insertion, and concerns about failure of fixation often lead surgeons to limit early motion. Newer technique of double-row repair in arthroscopic treatment may provide initial stronger fixation and more contact with bone at the repair site than single-row repair did. We studied the comparison between clinical outcomes of arthroscopic single- and double-row repair in cuff tears at 1year postoperatively. Materials and methods: We retrospectively analyzed 40 shoulders with single-row repair and 38 shoulders with double-row repair of full-thickness rotator cuff tears between May 2002 and October 2004. Out of total 78 shoulders, 42 (54%) were male patients and 36 (46%) were female patients and the mean age at surgery was 56 years. All patients were diagnosed by physical examination and MRI. At 1year' follow-up after operation, we evaluated with the ASES and the Constant scoring system, and measured muscle power of abduction, internal and external rotation of the affected shoulder then compared with each other. Results: Mean ASES scores and Constant scores in double-row repair group improved more than single-row repair group significantly at 1year postoperatively. Muscle power of abduction and internal rotation, especially abduction power, improved more significantly in double-row repair group than in single-row repair. Conclusion: Arthroscopic double-row repair for the full thickness rotator cuff tear may be a superior technique, which showed better clinical outcomes and restoration of muscle power compared with single-row repair at relatively short period of postoperative follow-up. Restoration of footprint close to normal anatomy by double-row repair seems to play an important role in the recovery of muscle strength.

Study on Condition of Fabrication Processing for R. F. High-power Unit Capacitor and Electrical Characteristics According to Addition of ZrO2 (고주파용 대용량 단위 유전체 제조공정과 ZrO2 첨가에 따른 전기적 특성 연구)

  • Ahn, Young-Soo;Kim, Joon-Soo;Park, Joo-Seok;Kim, Hong-Soo;Han, Moon-Hee;No, Kwang-Soo
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.9
    • /
    • pp.822-828
    • /
    • 2002
  • Fabrication and electrical characterization of R. F. High-power unit capacitors were investigated to study on condition of fabrication processing for R. F. High-power unit capacitor and electrical characteristics according to addition of $ZrO_2$. The unit capacitors were fabricated using tape casting. The optimum mixture ratio of dielectrics and mixing binder for the slurry fabrication was 57.5∼60.0: 42.5∼40.0 wt%. The slurry viscosity was 4000∼5000 cps and casting state of green tape fabricated using these slurry was excellent. Optimum stacking was made by 200 kg/$cm^2$ pressure with 80$^{\circ}C$ heating. $ZrO_2$ was added to improve the electrical characteristics of unit capacitor, especially breakdown characteristics. The dielectric constant and loss factor of the unit condenser having different $ZrO_2$ amounts was not changed in the addition range of 1 to 5 wt%. Also, dielectric constant was not changed in the frequency range of 10 to 500 kHz. It was found that characteristics of resistance voltage was improved through the formation of $CaZrO_3$ and the reduction of particle size as about 3wt% $ZrO_2$ was added.

Operation Characteristic Analysis of a Comb Actuator due to a Anisotropy Variation in RIE Etching (RIE 식각시 발생하는 비등방도 변화에 따른 머리빗형 액튜에이터의 동작 특성 분석)

  • Kim, Bong-Soo;Park, Ho-Jun;Pak, Jung-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.5
    • /
    • pp.368-376
    • /
    • 1999
  • This paper predicts the changes in the spring constant, the resonant frequency, the electrostatic force, and the displacement of a resonant structure due to non-ideal anisotropic RIE etching process. First, a $6\;{\mu}m$ thick polysilicon was etched by RIE and the anisotropy of the etched structure was measured as a function of a RF power, a $Cl_2$ flow rate and a chamber pressure. In the experimental results, an anisotropy was decreased as the RF power, the $Cl_2$ flow rate, or the chamber pressure was increased. A comb actuator's operation characteristic was predicted depending on the anisotropy variations in RIE etching. Comb actuators with three different support beam structures were investigated : fixed-fixed, crab-leg, and double crab-leg. As the RIE etch anisotropy becomes non-ideal, i.e. the cross section becomes rather a trapezoidal than a rectangular shape, it decreases spring constant, resonant frequency and electrostatic force of a comb actuator but it increases the displacement of the mass. Among the three structures, the comb actuator with double crab-leg support beams is more influenced by anisotropy variation in RIE etch than other two.

  • PDF

Performance of multi-cell stack for direct methanol fuel cells (직접메탄올 연료전지용 다층스택의 성능특성)

  • Lee, Chang-Hyeong;Jung, Doo-Hwan;Kim, Chang-Soo;Shin, Dong-Ryul
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1870-1872
    • /
    • 1999
  • Performance of 20-cell stack for direct methanol fuel cell (DMFC) was tested at constant temperature. Electrode evaluation used to the stack was tested by the performance of a single cell. A new composite electrode prepared from active carbon cloth and high porous active carbon was developed for hydrophilic layer of the cell. Characteristics of a single cell using the composite electrode showed the current density of $500mA/cm^2$ at the cell voltage of 0.4V at $120^{\circ}C$. For the operating of 20 days. the cell voltage at constant cell current densty of $100mA/cm^2$ was slightly reduced from 0.62V to 0.53V with the cell voltage decay rate of 14.5%. Power of 20-cell stack at 5.3V, $100^{\circ}C$ was about 180W.

  • PDF