• Title/Summary/Keyword: constant power

Search Result 2,851, Processing Time 0.026 seconds

Development of Digital DC-ARC Welding Machine

  • Kim, Hak-Kyeong;Park, Ba-Da
    • Journal of Ocean Engineering and Technology
    • /
    • v.20 no.6 s.73
    • /
    • pp.18-23
    • /
    • 2006
  • This paper introduces the results of the development of a new mobile digital DC-arc welding machine (DDWM). A simple PI controller is applied to the DDWM to control the output welding current that is tracking the constant setting current. Furthermore, a hot-start function, an anti-stuck function, a standby mode and an intelligential circuit breaker (ICB) are included in the DDWM. The DDWM increases welding quality and saves more power energy than a conventional welding machine. The DDWM is changed from ready mode into the standby mode, automatically, after 2-minute intervals from this unload start. Then, the DDWM is changed into ready mode, automatically, since it is reused for welding. Moreover, the DDWM increases welding quality, productivity and reduces costs of welding. So, the DDWM can make a considerable contribution to the mobile welding industries. The effectiveness of the DDWM was proven by the experimental results.

A Study on Novel Step-Up AC-DC Chopper of High Efficiency by using Lossless Snubber Capacitor (새로운 무손실 스너버 커패시터를 이용한 고효율 스텝 업 AC-DC 초퍼에 관한 연구)

  • Kwak, Dong-Kurl;Kim, Sang-Hoon
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.1103-1104
    • /
    • 2008
  • In this paper, authors propose a novel step-up AC-DC chopper operated with power factor correction (PFC) and with high efficiency. The proposed chopper behaves with discontinuous current control (DCC) of input current. The input current waveform in the proposed chopper is got to be a discontinuous sinusoid form in proportion to magnitude of ac input voltage under the constant duty cycle switching. Therefore, the input power factor is nearly unity and the control method is simple. In the general DCC chopper, the switching devices are turned-on with the zero current switching, but turn-off of the switching devices is switched at current maximum value. To achieve a soft switching of the switching turn-off, the proposed chopper is used a new partial resonant circuit. The result is that the switching loss is very low and the efficiency of chopper is high.

  • PDF

Design of a CMOS W VCO with Automatic Amplitude Control (자동진폭조절 기능을 갖는 CMOS IF VCO 설계)

  • 김유환;문요섭;이종렬;박종태;유종근
    • Proceedings of the IEEK Conference
    • /
    • 2002.06b
    • /
    • pp.145-148
    • /
    • 2002
  • In this paper, a voltage controlled oscillator (VCO) with automatic amplitude control is designed using a 0.35${\mu}{\textrm}{m}$ CMOS process. A cross-coupled PMOS pair is used for a negative resistance to compensate for the losses in the LC resonator, and an automatic\ulcorner amplitude control function is adapted to provide constant output power independent of the Q-factor of the LC resonator. The designed VCO operates in the 200MHz to 550MHz frequency range using different external resonators. The simulated phase noise is -128 dBc/Hz at 100KHz offset from the carrier frequency of 260MHz. It dissipates 0.㎽ from a 3V power supply. The area is 300${\mu}{\textrm}{m}$ x1201${\mu}{\textrm}{m}$.

  • PDF

Characteristics of the Voltages between the Communication Lines and Ground Induced by the Adjacent Artificial High-Voltage or Current ELF Source

  • Lee, Sang-Mu;Choi, Mun-Hwan;Cho, Pyung-Dong;Eun, Chang-Soo;Gimm, Yoon-Myoung
    • Journal of electromagnetic engineering and science
    • /
    • v.9 no.4
    • /
    • pp.175-181
    • /
    • 2009
  • The measurements were performed to verify experimentally that the voltage arising on a telecommunication line by a power line is due to the induction phenomena because there has been an opinion that the arising voltage on a telecommunication line is not by induction, but by other causality. The voltage appeared on the telecommunication line by way of an electric field or magnetic field generated by the source apparatus that had been artificially made to provide intentional constant high-voltage or current in ELF, that is, 60 Hz as an emulated commercial power.

OBSERVATIONAL STATUS OF THE TEXTURE LARGE-SCALE STRUCTURE FORMATION MODEL

  • UMEDA HIDEYUKI;FREESE KATHERINE
    • Journal of The Korean Astronomical Society
    • /
    • v.29 no.spc1
    • /
    • pp.23-24
    • /
    • 1996
  • We reexamined CDM texture large-scale structure (LSS) formation model. We confirmed that texture model is consistent with 4-year COBE data both in an open and a critical matter density (${\Omega}_0$ = 1) universes, and then obtained normalization for density perturbation power spectrum. We next compare the power spectrum with LSS observation data. Contrary to the previous literature, we found that texture model matches with these data in an open universe no better than in an ${\Omega}_0$ = 1 universe. We also found that the model is more likely to fit these data in a cosmological constant dominated ($\Lambda-$) universe.

  • PDF

DEVELOPMENT OF DIGITAL DC-ARC WELDING MACHINE (디지털 DC-ARC 용접기의 개발)

  • Park Ba-Da;Dung Ngo Manh;Kim Sang-Bong
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.71-72
    • /
    • 2006
  • This paper introduces the results of the development of a new mobile Digital DC-arc Welding Machine (DDWM). A simple PI controller is applied to the DDWM to control the output welding current tracking the constant setting current. Furthermore, a hot-start function, an anti-stuck function, a standby mode and an intelligential circuit breaker (ICB) are included in the DDWM. The DDWM increases welding quality and saves more power energy than a conventional welding machine. Because the DDWM is changed from ready mode into the standby mode automatically after 2 minutes interval from this unload start. Then the DDWM is changed into ready mode automatically since it is reused to weld. Mover, the DDWM increases welding qualify, productivity and reduces costs of welding. So, the DDWM can have a great of contribution to the mobile welding industries. The effectiveness of the DDWM was proven by the experimental results and durable test.

  • PDF

A Study on Fatigue Crack Growth Behavior of Steel Using AE (AE을 이용한 강의 피로균열전파 거동에 관한 연구)

  • Chung, K.Y.;Kim, S.J.;Kim, Y.S.;Oh, M.S.;Kim, Y.D.
    • Journal of Power System Engineering
    • /
    • v.5 no.2
    • /
    • pp.50-56
    • /
    • 2001
  • In this study, the effect of specimen thickness and stress ratio on fatigue crack growth in S45C steel was investigated. Acoustic emission was monitored during the fatigue crack growth test. Both crack closure and AE technique were used in assessing fatigue crack growth behavior. Constant amplitude loading tests were performed on CT type specimen with three different thicknesses and stress ratios. Crack closure was investigated to explain the influence of specimen thickness and stress ratio on the fatigue crack growth in the second growth region. The crack closure effect was decreased with specimen thickness and stress ratio.

  • PDF

The Effect of Heat Input on Grooving Corrosion Behavior in the Welds of Electric Resistance Welding Steel Pipe (ERW 강관 용접부의 홈부식거동에 미치는 입열량의 영향)

  • Lee, B.W.;Lee, J.S.;Park, H.S.
    • Journal of Power System Engineering
    • /
    • v.11 no.3
    • /
    • pp.41-46
    • /
    • 2007
  • The microstructure and electrochemical analysis of welds of electric resistance welding(ERW) pipe were investigated. The direction of metal flow line in HAZ of ERW pipe shifted to the inner(or outer) surface of pipe by plastic deformation during welding. The lowest heat input welds of ERW pipe was showed crack by liquid penetrant testing. Accelerated corrosion test by constant current density of 20mA/$cm^{2}$ developed groove at the welds of ERW pipe and the measured grooving factors were about $1.2{\sim}1.5$. Corrosion potential of base metal obtained by cyclic polarization in artificial sea water(3.5wt.% NaCl solution) was 100mV higher than that of weld metal of ERW pipe.

  • PDF

Analysis of Transient Conduction Heat Loss of Solid Sphere between Constant and Variable Free Convection (상수 또는 변수의 대류 경계조건을 가지는 구의 과도열전도 손실에 대한 해석)

  • Kim, M.J.;Chea, G.H.
    • Journal of Power System Engineering
    • /
    • v.14 no.4
    • /
    • pp.17-22
    • /
    • 2010
  • 본 연구는 구의 과도 열전도에 의한 열손실을 계산하는 데 있어, 외부의 경계조건인 대류의 조건에 해당하는 상황을 상수 및 변수로 가정하였을 경우의 열전달문제를 해석한 것이다. 이 문제를 해결하기 위해 집중열용량법을 사용하고 있으며, 대류열전달계수의 값이 온도의 함수로 변한다고 가정하여 계산하였다. 계산을 수행한 결과 대류경계조건의 값을 상수로 가정한 경우가 열손실이 높이 평가된다는 것을 알았고, 이러한 경향을 상관식으로 정리하였다.

A Study on the Thermal Characteristics of the Low Temperature Vacuum Dryer by the Vacuum Chamber Temperature (진공실 온도에 의한 저온진공건조기의 열적 특성에 관한 연구)

  • Choe, S.Y.
    • Journal of Power System Engineering
    • /
    • v.14 no.4
    • /
    • pp.23-28
    • /
    • 2010
  • Of the roughly four million known substances, about 60,000 are processed and sold ; many of these must be dried. Many materials are processed in the liquid state - ideal for mixing and reacting - but most products are needed or wanted as dry, or relatively dry, solids. Usually operation is just below atmospheric pressure, as with direct dryers, but some are built for vacuum operation with pressures as low as 26.66kPa abs.. In spite of the global-class aquiculture agriculture and fisheries technology of our country, the processing technologies are lags behind the other nations relatively. These problems are considered to be caused directly by the lack of drying technologies. This paper is concerned to the experimental results of drying heat transfer characteristics for the green energy type vacuum dryer for the high quality agriculture and fisheries production.