• Title/Summary/Keyword: constant current stress

Search Result 145, Processing Time 0.022 seconds

Prediction of gate oxide breakdwon under constant current stresses (정전류 스트레스 하에서 게이트 산화막의 항복 특성 예측)

  • 정태식;최우영;이상돈;윤재석;김재영;김봉렬
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.7
    • /
    • pp.162-170
    • /
    • 1996
  • A breakdown model of gate oxides under constant current stresses is proposed. This model directly relates the oxide lifetime to the stress current density, and includes statistical nature of oxide breakdown using the concept of "effective oxide thinning". It is shown tha this model can reliably predict the TDDB characteristics for any current stress levels and oxide areas.

  • PDF

The Effect of Compressing ER Electrode on Electrorheological Properties of Anhydrous ER Fluids (ER 유체용 압축전극이 ER 유체의 전기유변학적 특성에 미치는 영향)

  • Ahn, Byeng-Gil
    • Tribology and Lubricants
    • /
    • v.18 no.1
    • /
    • pp.16-23
    • /
    • 2002
  • For increasing the yield stress of ER fluids, the compressing ER electrode was developed and the compressing electrorheological (ER) behavior of anhydrous ER fluids in silicone oil of phosphorous ester cellulose powder was investigated. Under constant electric field, not only the current density but also the yield stress of anhydrous ER fluids were studied as varying the compressing length of ER electrode distance. From the experimental results the compressing of ER electrode had a large influence to the ER properties of anhydrous ER fluids. The current density was proportional to the compressing length of ER electrode under constant electric field and volume fraction also tile compressing yield stress was proportional to the volume fraction of dispersed particles under constant electric field and compressing length. When the ER electrode was compressed with 150mm after charging the electric field, 4 kV, tile yield stress of phosphoric ester cellulose ER fluids increased to thirteen times comparing with the yield stress measured at normal electrode.

The Effect of Compressing ER Electrode on the Electrorheological Properties of ER Fluids (ER 유체용 압축전극이 ER 유체의 전기유변학적 특성에 미치는 영향)

  • 안병길
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.138-145
    • /
    • 2001
  • For increasing the yield stress of ER fluids, the compressing ER electrode was developed and the compressing electrorheological (ER) behavior of anhydrous ER fluids in silicone oil of phosphorous ester cellulose powder was investigated. Under constant electric field, not only the current density but also the yield stress of anhydrous ER fluids were studied as varying the compressing length of compressing ER electrode. From the experimental results, the compressing of ER electrode had a large influence to the ER properties of anhydrous ER fluids. The current density was proportional to the compressing length of ER electrode under constant electric field and volume fraction also the compressing yield stress was proportional to the volume fraction of dispersed particles under constant electric field and compressing length. When the ER electrode was compressed with 150mm after charging the electric field, 4 kV, the yield stress of phosphoric ester cellulose ER fluids increased to thirteen times comparing with the yield stress measured at normal electrode.

  • PDF

On Corrosion Behaviors in Welded Zone of API 5L-X65 Steel for Natural Gas Transmission (천연가스 수송용 API 5L-X65강 용접부의 부식거동에 관한 연구)

  • JO SANG-KEUN;SONG HAN-SEOP;KONG Yu-SIK;KIM YOUNG-DAI
    • Journal of Ocean Engineering and Technology
    • /
    • v.18 no.5
    • /
    • pp.50-56
    • /
    • 2004
  • This study is on the constant-current stress corrosion test, related to the load stress, in both the welded and non-welded zones of high tensile strength steel that is used for natural gas transmission. The surface corrosion pattern of the welded zone of API 5L-X65 specimens for natural gas transmission showed general corrosion and narrow pitting, and the pitting was increased with load stress. Initially, the average relative electrode potential and the average relative current of the high tensile strength steel, used for natural gas transmission specimens, were decreased rapidly, and the average relative electrode potential was higher and the average relative current was lower in welded zone, compared to base metal. The average relative electrode potential was decreased with load stress, and the average relative current was somewhat increased by increasing the load stress. The corrosion rate was less in welded zone, compared to base metal, and the corrosion rate was decreased by increasing the load stress.

A Study on Stress Corrosion Behaviors in Welded Zone of the API 5L-X65 Steel for Natural Gas Transmission (천연가스 수송용 API 5L-X65강 용접부의 부식거동에 관한 연구)

  • JO SANG-KEUN;SONG HAN-SEOP;KONG YOO-SIK;KIM YUONG-DAI
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.401-407
    • /
    • 2004
  • This study is on the constant-current stress corrosion test related to the load stress in welded zone and non-welded zone of high tensile strength steel for natural gas transmission. The surface corrosion pattern of the welded zone of API 5L-X65 specimens for natural gas transmission showed global corrosion and narrow pitting, and the pitting was increased by increasing the load stress. Initially, the average relative electrode potential and the average relative current of the high tensile strength steel for natural gas transmission specimens was decreased suddenly, and the average relative electrode potential was higher and the average relative current was lower in welded zone than base metal. and the average relative electrode potential was decreased by increasing the load stress, and the average relative current was somewhat increased by increasing the load stress. The corrosion rate was less in welded zone than base metal, and the corrosion rate was decreased by increasing the load stress.

  • PDF

A study on Stress Corrosion Cracking of Sensor Wire in Thermally Insulated Underground Pipeline (이중보온관 부식감지선의 응력부식파괴에 관한 연구)

  • Choe, Yun-Je;Kim, Jeong-Gu
    • Korean Journal of Materials Research
    • /
    • v.12 no.2
    • /
    • pp.103-111
    • /
    • 2002
  • The thermally insulated underground pipelines have been used for district heating system. The sensor wire embedded in the insulation was used for monitoring the insulating resistance between the sensor wire and the pipe. The resistance measurement system detects corrosion of steel pipe under insulation. The corrosion and stress corrosion cracking(SCC) characteristics of sensor wire in synthetic ground water were investigated using the electrochemical methods and constant load SCC tests. The polarization tests were used to study the electrochemical behavior of sensor wire. The sensor wire was passivated at temperatures ranging from 25 to $95^{\circ}C$. However, the applied sensing current larger than passive current resulted in breakdown of passive film. The constant load SCC tests were performed to investigate the effects of applied current and load on the fracture behavior. Stress-corrosion cracks initiated at pits that were produced by sensing current. The growth of the pit involves a tunnelling mechanism, which leads to ductile fracture.

The Characteristics of LLLC in Ultra Thin Silicon Oxides (실리콘 산화막에서 저레벨누설전류 특성)

  • Kang, C.S.
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.8
    • /
    • pp.285-291
    • /
    • 2013
  • In this paper, MOS-Capacitor and MOSFET devices with a Low Level Leakage Current of oxide thickness, channel width and length respectively were to investigate the reliability characterizations mechanism of ultra thin gate oxide films. These stress induced leakage current means leakage current caused by stress voltage. The low level leakage current in stress and transient current of thin silicon oxide films during and after low voltage has been studied from strss bias condition respectively. The stress channel currents through an oxide measured during application of constant gate voltage and the transient channel currents through the oxide measured after application of constant gate voltage. The study have been the determination of the physical processes taking place in the oxides during the low level leakage current in stress and transient current by stress bias and the use of the knowledge of the physical processes for driving operation reliability.

Effects of Hot-Carrier Stress and Constant Current Stress on the Constant Performance Poly-Si TFT with a Single Perpendicular Grain Boundary (단일 수직형 그레인 경계 (Single Perpendicular Grain Boundary) 구조를 가지는 고성능 다결정 실리콘 박막 트랜지스터(Poly-Si TFT)에서의 고온 캐리어 스트레스(Hot Carrier Stress) 및 정전류 스트레스(Constant Current Stress) 효과)

  • Choi, Sung-Hwan;Song, In-Hyuk;Shin, Hee-Sun;Han, Min-Koo
    • Proceedings of the KIEE Conference
    • /
    • 2006.10a
    • /
    • pp.50-52
    • /
    • 2006
  • 본 논문은 고성능 다결정 실리콘(Poly-Si) 박막 트랜지스터 (Thin Film Transistor)에서 단일 수직 그레인 경계(Single Perpendlcular Grain Boundary)가 고온 캐리어 스트레스(Hot Carrier Stress) 및 정전류 안정성 평가에서 어떠한 효과를 보이는가에 대해서 살펴보았다. 고온 캐리어 스트레스 하에서($V_G=V_{TH}+1V,\;V_D$ =12V),그레이 경계가 없는 다결정 실리콘 TFT와 비교했을 때 그레인 경계를 가지고 있는 다결정 실리를 TFT는 전기 전도(Electric Conduction)에 작용하는 자유 캐리어(Free Carrier)의 개수가 적기 때문에 상대적으로 더욱 우수한 전기적 특성을 나타낸다. 먼저 1000초 동안 고온 캐리어 스트레스를 가해준 결과 단일 그레인 경계를 가진 다결정 실리콘에서의 트랜스 컨덕턴스(Transconductance)의 이동 정도는 5% 미만으로 확인되었다. 반면에 같은 스트레스 조건 하에서 그레인 경계가 존재하지 않는 다결정 실리콘의 경우에는 그 이동 정도가 약 25%에 달하는 것으로 측정되었다. 다음으로 정전류 스트레스(Constant Current Stress) 인가시, 수직형 그레인 경계가 채널 영역 내에 존재하지 않는 다결정 실리콘 TFT는 드레인 접합 부분의 전계 세기를 비교했을 때, 그레인 경계를 가지고 있는 다결정 실리콘 TFT보다 상대적으로 낮은 원 인 때문에 적게 열화되는(Degraded) 특성을 확인할 수 있었다.

  • PDF

Characterization of Radial Stress in Curved Beams

  • Oh, Sei Chang
    • Journal of the Korean Wood Science and Technology
    • /
    • v.37 no.2
    • /
    • pp.128-136
    • /
    • 2009
  • Curved glued laminated timber (glulam) is rapidly coming into the domestic modern timber frame buildings and predominant in building construction. The radial stress is frequently occurred in curved beams and is a critical design parameter in curved glulam. Three models, Wilson equation, Exact solution and Approximation equation were introduced to determine the radial stress of curved glulam under pure bending condition. It is obvious that radial stress distribution between small radius and large radius was different due to slight change of neutral plane location to center line. If the beam design with extremely small radius, it should be considered to determine the exact location of maximum radial stress. The current standard KSF 3021 was reviewed and would be considered some adjustment determining the optimum radius in curved glulam. Current design principle is that the stress factor is given by the curvature term only in constant depth of the beam, but like tapered or small radius of beams, the stress factor by Wilson equation was underestimated. So current design formula should be considered to improvement for characterizing the radial stress factor under pure bending condition.