• 제목/요약/키워드: conservative conditions

검색결과 395건 처리시간 0.018초

무작위 추출 방법을 이용한 원자력발전소 보수적 안전해석 조건 결정 (Identification of the Most Conservative Condition for the Safety Analysis of a Nuclear Power Plant by Use of Random Sampling)

  • 정해용
    • 한국안전학회지
    • /
    • 제30권5호
    • /
    • pp.131-137
    • /
    • 2015
  • For the evaluation of safety margin of a nuclear power plant using a conservative methodology, the influence of applied assumptions such as initial conditions and boundary conditions needs to be assessed deliberately. Usually, a combination of the most conservative initial conditions is determined, and the safety margin for the transient is evaluated through the analysis for this conservative conditions. In existing conservative methodologies, a most-conservative condition is searched through the analyses for the maximum, minimum, and nominal values of the major parameters. In the present study, we investigates a new approach which can be applied to choose a most-conservative initial condition effectively when a best-estimate computer code and a conservative evaluation methodology are utilized for the evaluation of safety margin of transients. By constituting the band of various initial conditions using the random sampling of input parameters, the sensitivity study for various parameters are performed systematically. A method of sampling the value of control or operation parameters for a certain range is adopted by use of MOSAIQUE program, which enables to minimize the efforts for achieving the steady-state for various different conditions. A representative control parameter is identified, which governs the reactor coolant flow rate, pressurizer pressure, pressurizer level, and steam generator level, respectively. It is shown that an appropriate distribution of input parameter is obtained by adjusting the range and distribution of the control parameter.

Conservative Loan Loss Allowance and Bank Lending

  • TAKASU, Yusuke;NAKANO, Makoto
    • The Journal of Asian Finance, Economics and Business
    • /
    • 제6권3호
    • /
    • pp.9-18
    • /
    • 2019
  • The purpose of this study is to investigate the relation between conservative loan loss accounting practice of banks, defined as accounting behavior that increases loan loss allowances against expected credit losses, and bank lending. Furthermore, we specify the macroeconomic conditions reflecting debtors' borrowing environments and analyze how these conditions affect the relation between conservative loan loss allowances and bank lending. Although existing literature reports that accounting conservatism has a direct effect on non-financial firms' investment behavior, there is little evidence about an effect of conservatism on banks' lending behavior. By exploiting data showing the links between individual Japanese firms and their individual lenders to control both loan demand and supply, we estimate OLS regressions to test the relationships among conservative loan loss allowance, bank lending, and macroeconomic conditions using a unique dataset containing bank-firm-year observations between 2001 and 2013. We find banks that have conservative loan loss allowances tend to provide fewer loans to firms with financing needs when macroeconomic conditions are good and these conservative banks are likely to provide more loans to firms when macroeconomic conditions are bad. Our findings suggest that reflecting expected credit loss into loan loss allowances can mitigate the procyclical behavior of banks.

근관성형후 나타나는 동통에 관한 임상적 연구 (THE DEGREE AND INCIDENCE OF INTERAPPOINTMENT PAIN ASSOCIATED WITH CLINICAL FACTORS AFTER CANAL ENLARGEMENT)

  • 금기연;박동수;이찬영;이승종;이정석
    • Restorative Dentistry and Endodontics
    • /
    • 제15권1호
    • /
    • pp.175-186
    • /
    • 1990
  • The purpose of this study was to determine whether any clinical factors or conditions are associated with an increased incidence or degree of pain occuring during endodontic treatment in patients who begin treatment with no symptoms. The 260 teeth of 256 patients were surveyed and statistical analysis was used to determine whether a significant relationship existed between pain and any recorded clinical factors or conditions. The following conclusions were drawn. 1. No significant relationship between interappointment pain and any of the analyzed clinical factors or conditions except for fistula formation could be determined. 2. The presence of a draining fistula from a periapical lesion significantly decreased the posttreatment pain. 3. The judicious use of canal irrigants and canal medicaments is not associated with an increased incidence or degree of interappointment pain.

  • PDF

Comparing volumetric and biological aspects of 3D-printed interim restorations under various post-curing modes

  • Song, Gun;Son, Ji-Won;Jang, Ji-Hyun;Choi, Sung-Hyeon;Jang, Woo-Hyung;Lee, Bin-Na;Park, Chan
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권2호
    • /
    • pp.71-78
    • /
    • 2021
  • Purpose. This study aims to compare the volumetric change, degree of conversion (DOC), and cytotoxicity of 3D-printed restorations post-cured under three different conditions. Materials and Methods. 3D-printed interim restorations were post-cured under three different conditions and systems: 5 min, 30 min, and 24 h. Three-unit and six-unit fixed dental prostheses (n = 30 for each case) were printed; ten specimens from each group were post-cured and then scanned to compare their volumetric changes. Root-mean-squared (RMS) values of the data were acquired by superimposing the scanned files with original files. Thirty disk-shaped specimens were printed to evaluate the DOC ratio. Fourier transform infrared spectroscopy was used to compare the DOCs of 10 specimens from each group. Human gingival fibroblasts were used to measure the cell viability of every specimen (n = 7). The data from this experiment were employed for one-way analysis of variance and Tukey's post-hoc comparisons. Results. Differences between the three-unit restorations were statistically insignificant, regardless of the post-curing conditions. However, for the six-unit restorations, a high RMS value was acquired when the post-curing duration was 30 min. The average DOC was approximately 56 - 62%; the difference between each group was statistically insignificant. All the groups exhibited cell viability greater than 70%, rendering them clinically acceptable. Conclusion. The post-curing conditions influenced the volume when the length of the restoration was increased. However, this deviation was found to be clinically acceptable. Additionally, post-curing did not significantly influence the DOC and cytotoxicity of the restorations.

갈륨과 아말감 수복물의 변연미세누출에 관한 비교 연구 (COMPARISON OF MICROLEAKAGE OF GALLIUM ALLOY AND AMALGAM RESTORATION)

  • 이민호;이희주;허복
    • Restorative Dentistry and Endodontics
    • /
    • 제23권1호
    • /
    • pp.269-277
    • /
    • 1998
  • This in vitro study compared the microleakage of 4 lining conditions when used with Gallium alloy GF II and Valiant PhD. Class V cavity was prepared on both buccal and lingual surface of 80 extracted human premolar & molar teeth with one margin in enamel and another in dentin. Before restoration, prepared cavities were applied to no-liner, cavity varnish, Scotchbond multipurpose, and Superbond D-liner II plus according to manufacture's instructions. The restored teeth were stored in saline for 1 week, then thermocycled for 100 times, stained with 0.5% basic fuchsin dye for 1 day, sectioned, and observed using a light microscope. Following results were obtained. 1. The leakage value of Superbond-lined group showed significantly lower than that of nolined group on both margins of Valiant PhD(p<0.05). 2; There was no significant difference between the 4 lining conditions in Gallium alloy GF II (p>0.05). 3. When We make a comparison between Gallium alloy GF II and Valiant PhD under same lining conditions, the microleakage value of Gallium alloy GF II showed lower than that of Valiant PhD on occlusal & gingival margin(p<0.05) except for Superbond-lined group(p>0.05).

  • PDF

Application of a combined safety approach for the evaluation of safety margin during a Loss of Condenser Vacuum event

  • Shin, Dong-Hun;Jeong, Hae-Yong;Park, Moon-Ghu;Sohn, Jung-Uk
    • Nuclear Engineering and Technology
    • /
    • 제54권5호
    • /
    • pp.1698-1711
    • /
    • 2022
  • A combined safety approach, which uses a best-estimate computer code and adopts conservative assumptions for safety systems availability, is developed and applied to the safety margin evaluation for the Loss of Condenser Vacuum (LOCV) of the 1000 MWe Korean Nuclear Power Plant. The Multi-dimensional Analysis of Reactor Safety-KINS standard (MARS-KS) code is selected as a best-estimate code and the PAPIRUS program is used to obtain different initial operational conditions through random sampling of control variables. During an LOCV event, fuel integrity is not threatened by the increase in Departure from Nuclear Boiling Ratio (DNBR). However, the high pressure in the primary coolant system and the secondary system might affect the system integrity. Thus, the peak pressure becomes a major safety concern. Transient analyses are performed for 124 cases of different initial conditions and the most conservative case, which results in the highest system pressure is selected. It is found the suggested methodology gives similar peak pressures when compared to those predicted from existing methodologies. The proposed approach is expected to minimize the time and efforts required to identify the conservative plant conditions in the existing conservative safety methodologies.

Interfacial ultrastructure of the AQ Bond Plus

  • Haruyama, Chikahiro;Amgai, Tetsuya;Sugiyama, Toshiko;Muto, Yoshitake;Takase, Yasuaki;Hirai, Yoshito
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2003년도 제120회 추계학술대회 제 5차 한ㆍ일 치과보존학회 공동학술대회
    • /
    • pp.601-601
    • /
    • 2003
  • AQ Bond Plus has the function of self-etching priming adhesive, which can be applied by single coating without second coating, being different from conventional AQ bonds. Moreover, because the absorption range of light became wider, the bond can comply with any visible light curing units. Thus, the bond can produce an unified form between the dentine layer with impregnated resin of good quality and the thin and hard film characteristically. In this study, we investigated the junctional conditions of AQ Bond Plus, using a scanning electron microscope (SEM).(omitted)

  • PDF

Diagnostic challenges of nonodontogenic toothache

  • Park, Hyung-Ok;Ha, Jung-Hong;Jin, Myoung-Uk;Kim, Young-Kyung;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • 제37권3호
    • /
    • pp.170-174
    • /
    • 2012
  • The objective of this article was to present two nonodontogenic conditions that may mimic odontogenic toothache: trigeminal neuralgia and burning mouth syndrome. Two cases are presented in which one is related to the upper left second premolar and the other is related to the upper left first molar. Both showed pain when chewing. These two cases highlight the complexities involved in diagnosing nonodontogenic toothache. This article demonstrates the importance of having a thorough knowledge of both odontogenic and nonodontogenic toothache, as well as the need for careful evaluation of the nature of the pain and history, clinical and radiographic examinations.

Cyclic fatigue resistance tests of Nickel-Titanium rotary files using simulated canal and weight loading conditions

  • Cho, Ok-In;Versluis, Antheunis;Cheung, Gary S.P.;Ha, Jung-Hong;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • 제38권1호
    • /
    • pp.31-35
    • /
    • 2013
  • Objectives: This study compared the cyclic fatigue resistance of nickel-titanium (NiTi) files obtained in a conventional test using a simulated canal with a newly developed method that allows the application of constant fatigue load conditions. Materials and Methods: ProFile and K3 files of #25/.06, #30/.06, and #40/.04 were selected. Two types of testing devices were built to test their fatigue performance. The first (conventional) device prescribed curvature inside a simulated canal (C-test), the second new device exerted a constant load (L-test) whilst allowing any resulting curvature. Ten new instruments of each size and brand were tested with each device. The files were rotated until fracture and the number of cycles to failure (NCF) was determined. The NCF were subjected to one-way ANOVA and Duncan's post-hoc test for each method. Spearman's rank correlation coefficient was computed to examine any association between methods. Results: Spearman's rank correlation coefficient (${\rho}$ = -0.905) showed a significant negative correlation between methods. Groups with significant difference after the L-test divided into 4 clusters, whilst the C-test gave just 2 clusters. From the L-test, considering the negative correlation of NCF, K3 gave a significantly lower fatigue resistance than ProFile as in the C-test. K3 #30/.06 showed a lower fatigue resistance than K3 #25/.06, which was not found by the C-test. Variation in fatigue test methodology resulted in different cyclic fatigue resistance rankings for various NiTi files. Conclusions: The new methodology standardized the load during fatigue testing, allowing determination fatigue behavior under constant load conditions.