• Title/Summary/Keyword: connection type

Search Result 1,446, Processing Time 0.032 seconds

A Study on the Operational Characteristics of a Squirrel-cage type Wind Turine Induction Generator (농형 풍력 유도발전기의 운전 특성에 관한 연구)

  • Jang, Sung-Il;Jeong, Jong-Chan;Choi, Jeong-Hwan;Park, Je-Young;Kim, Kwang-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1309-1312
    • /
    • 2002
  • The electric power network paralleled with wind turbine generator may have the negative impacts on the protection, operation, and management caused by the operation of wind turbine generator. Therefore, it is necessary to investigate the operating characteristic of wind turbine generator. This paper describes model of a squirrel-cage type wind turbine induction generator and the soft cut-in connection method for reducing the transient state on power network, and simulates various cases of wind turbine operations. The radial distribution network of IEEE 13-bus are modeled and tested by PSCAD/EMTDC.

  • PDF

A Experimental Study on the Repeatability of Network RTK-GPS with Spider Net Type (Spider Net 방식 Network RTK-GPS측량의 반복재현성에 대한 실험연구)

  • Kim, Sun-Chul;Kang, Sang-Gu;Lee, Jin-Duk
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2007.04a
    • /
    • pp.37-42
    • /
    • 2007
  • A network of MAC type was constructed in the Gyeonggi-do area to analyze the usefulness and validity of the Network RTK-GPS. Six sites were selected to conduct GPS observation for 24 hours, and by determining the ITRF of each site, coordinates were determined in connection with IGS network. Then check points which were established in Gimpo area were observed at least 7 times by Network RTK at 20 secs of retrieval intervals. The result showed high accuracy in the difference between the coordinates determined immediately by the in-field network survey and the current performance was 1-2cm. Its biggest benefit is the expanded range of survey and efficiency of practice. In summary, it is proved that a network survey has the accuracy, scalability and efficiency and it is expected that the network survey will contribute to the cadastral survey.

  • PDF

A Method for Enhancing Data Transmission Performance in the Power-Line Communication Channel with Low-Voltage Surge Protective Devices (저압용 SPD가 설치된 전력선통신에서 데이터전송 성능 향상)

  • Choi, Jong-Min;Jeon, Tae-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.2
    • /
    • pp.78-85
    • /
    • 2012
  • Low-Voltage power lines should equip surge protection devices which protect electronic equipments and human lives against lightning and abnormal voltages. Data transmission capacity of the power line is determined by frequency characteristics of the surge protective devices. To analyze the effects of surge protective devices on the data transmission performance, various combinations of installation methods are tested which include ZnO varistor elements that is compatible with class I, class II and class III. The result claims that ZnO varistor for class III is found to be one of the main factors that deteriorates the transmission performance. To overcome this problem a serial connection methed between Gap type SPD and ZnO varistor is proposed. With the proposed scheme, laboratory experimental results show that the data transmission performance can be improved up to 91.9[%] with proper SPD combination.

A study on the experimental evaluation of an Angle Type Anchorage System (Angle형 기기 정착부의 성능평가에 관한 실험적 연구)

  • 김강식;서용표;유원진;김갑순
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.03a
    • /
    • pp.266-274
    • /
    • 2002
  • A typical case where the effects of prying in the base angle type anchorage system with expansion bolt. This connection consists of an angle which is attathed to an equipment cabinet and bolted to a concrete slab via an expantion bolt. A seismic analysis of the cabinet may indicate a vertical load, P, transferred to the vertical leg of the angle due to overturning of the cabinet. Due to the eccentricity, b(e), and the continuous beam action in the base member, the load resisted by the bolt will be amplified by a factor λ. Thus, in this study, experimental evaluation of the anchorage system is executed.

  • PDF

Design of the Magnetic Core Reactor for the connection to the Power System of DC Reactor Type High Temperature Superconducting Fault Current Limiter (DC 리액터형 고온초전도한류기의 전력계통 연계를 위한 자기철심리액터의 설계)

  • 임대준;배덕권;김호민;이찬주;윤경용;윤용수;고태국
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.322-325
    • /
    • 2002
  • In this paper, the power-linking device connecting the high-Tc super-conducting(HTS) coil to the power system in the DC reactor type three-phase high-Tc superconducting fault current limiter (SFCL) has been designed. This design was triggered from the concept that the magnetic energy could be exchanged into the electrical energy each other. Ferromagnetic material is used as the path of magnetic flux. The device mentioned above was named Magnetic Core Reactor(MCR). MCR was designed to minimize the voltage drop caused by copper loss. The current density of the conductor was 1.3 A/mm$^2$ and % voltage drop was 2%.

  • PDF

Thermoelectric Property and p-n Transition Mechanism of Hot Pressed Bi4/3Sb2/3Te3 ($Bi_{4/3}Sb_{2/3}Te_3$ 가압소결체의 열전특성과 p-n 전이기구)

  • 박태호;유한일;심재동
    • Journal of the Korean Ceramic Society
    • /
    • v.29 no.11
    • /
    • pp.855-862
    • /
    • 1992
  • Thermoelectric power, electrical conductivity and Hall effect were measured, as functions of temperature in the range of 100 to 600 K, on polycrystalline Bi4/3Sb2/3Te3 which had been prepared via uniaxial hot-pressing at different temperatures in the range of 373 K to 773 K, aiming at searching a profitable processing route to a polycrystalline thermoelectric material, a promising, viable alternative to a single crystalline one. It was found that, with increasing temperature of pressing under a fixed pressure, the material, normally a p-type prior to being hot-pressed, underwent a transition to n-type. This transition was confirmed to be due to plastic deformation during hot-pressing and interpreted as being attributed to the change of the major ionic defect BiTe' into TeBi˙at temperature high enough for structure elements mobility. Thermoelectric figure-of-merit of the hot-pressed material was discussed in connection with the p-n transition in addition to microstructure.

  • PDF

Evaluation of the Effect on the Valve Flow Coefficient by Attached Fitting (밸브 후단 피팅에 따른 밸브 용량계수의 영향 평가)

  • Kang, Seung-Kyu;Lee, Won-Sik;Yoon, Joon-Yong;Min, Kyung-Wha
    • The KSFM Journal of Fluid Machinery
    • /
    • v.6 no.4 s.21
    • /
    • pp.29-37
    • /
    • 2003
  • This study was undertaken to verify the effect of flow coefficient when a globe control valve was attached by different type of fitting. The valve flow coefficient is usually determined by measuring the flow rate and the pressure drop with the connection of straight pipe through the valve. The effect of different fitting that is mounted on the downstream of the valve is studied. Four types of fittings and three distances between the valve and a downstream fitting are compared parametrically to investigate the effect on the flow coefficient of it. Measured flow coefficient and numerically predicted value by using computational fluid dynamics were compared in detail. It is concluded that the flow coefficient is reduced if the fitting is attached after a valve, but the effect of different type of fitting is not crucial.

A Study of Non-PC Device Application Service and A Prospect for Service Platform (Non-PC 형 정보단말 응용서비스 및 서비스 플랫폼 전망)

  • Kim, Dong-Hoon;Bae, Jung-Il;Kim, Su-Jin;Yeon, Seung-Ho
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.100-103
    • /
    • 2007
  • For several ten years, the Internet and IT services have been greatly developed in PC area and with this, new BM and services with terminals like Post-PC and Non-PC types will come into the spotlight in few years. In various fields of service, terminals exclusive to individual service come into the market already, the hardware and the contents used in the terminals are circulating. The communication service providers are very enthusiastic about developing and providing various services in order to overcome the growth limit of existing network connection service. And they think that providing the Non-PC type Information Appliance services will make added values and be sources of making profits in next generation. Hereupon we are going to observe the Non-PC type Information Appliance services, the structure of the service platform that make that services possible, and their prospect.

  • PDF

A Study on the Architectural Planning of Joint Pattern in the Triangular Type Ward (삼각형병동의 결합유형에 관한 건축계획적 연구)

  • Kim, Khil-Chae
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.12 no.2
    • /
    • pp.59-67
    • /
    • 2006
  • The purpose of this study is to present the research data to improve the quality of triangular ward in general hospital in Korea. Drawing documents analysis were used to examine the condition of ward. This study in focused on patient room and atrium according to connection type of triangular ward, allocation of NS, module and direction of patient room. The results of this study is as follows; Triangular ward has two joint pattern(conner and conner, side and side). Conner and conner joint pattern is good at planning of lighting than side and side joint pattern. Triangular ward can has different module system in each side. Allocation of NS is important factor which is focused on patient relationship or ward control.

  • PDF

A Study on the Composing Type of Space in the Garden House and a special Quality (전원주택의 공간구성 유형과 특성에 관한 연구)

  • 주승범
    • Korean Institute of Interior Design Journal
    • /
    • no.7
    • /
    • pp.12-20
    • /
    • 1996
  • Rurban house is the place to satisfy man's the most basic desires to live and dwell. In this study , the composing Type of the outer space and its connection with the innerspace are researched. And also it investigated how various environmental factors are reflected in the rurban housing development. As Louis Kahn said, "Archiecture is the thoughtful for-mation the space and the endless transformation of architec-ture is derived from the change of space idea." In the recent days, It is true that the qualitative aspect of a rurban house rather than the quantitative one has empha-sized. As man cannot make a living when seperated from the nature, the currents of life in the rurban house should be flowed into the new environmental change.

  • PDF