Cyclic testing of weak-axis steel moment connections

  • Lee, Kangmin;Li, Rui;Jung, Heetaek;Chen, Liuyi;Oh, Kyunghwan
    • Steel and Composite Structures
    • /
    • 제15권5호
    • /
    • pp.507-518
    • /
    • 2013
  • The seismic performance of six types of weak-axis steel moment connections was investigated through cyclic testing of six full-scale specimens. These weak-axis moment connections were the column-tree type, WUF-B type, FF-W type, WFP type, BFP-B type and DST type weak-axis connections. The testing results showed that each of these weak-axis connection types achieved excellent seismic performance, except the WFP and the WUF-B types. The WFP and WUF-B connections displayed poor seismic performance because a fracture appeared prematurely at the weld joint due to stress concentrations. The column-tree type connection showed the best seismic behavior such that the story drift ratio could reach 5%.

전지의 연결방법에 따른 전류의 특성에 대한 초등교사들의 오개념 유형과 그 일관성 (Types of Misconceptions and their Consistencies of the Elementary School Teachers about the Characteristics of Currents according to the Connection Methods of Batteries in Simple Electric Circuits)

  • 현동걸;신애경
    • 과학교육연구지
    • /
    • 제38권2호
    • /
    • pp.331-343
    • /
    • 2014
  • 전지의 연결방법에 따른 전류의 특성에 대한 초등교사들의 오개념 유형과 그 일관성에 대하여 조사되었다. 초등교사들의 전지의 연결방법에 따른 전류의 특성에 대한 오개념은 3가지 유형으로 나타났다. 14명의 초등교사들을 대상으로 한 이 연구에서, 전지들의 직렬연결과 병렬연결시 전류의 특성을 연결하는 전지의 수에 초점을 맞추는 유형에는 2명의 초등교사가, 전지의 직렬연결에 대한 개념과 병렬연결에 대한 개념을 혼동하는 유형에는 8명의 초등교사가, 그리고 전지의 직렬연결과 병렬연결에 대한 개념을 저항의 직렬연결과 병렬연결에 대한 개념으로 혼동하는 유형에는 4명의 초등교사가 분포하였다. 초등교사들은 전지의 연결에 대한 학습개념이 적용되는 상황에서 뿐만 아니라 분화개념이 적용되어야 하는 상황에서도 그들의 오개념 유형을 일관성 있게 적용하고 있었다.

  • PDF

혼합구조의 성능 향상을 위한 개선된 접합방식의 개발 (I) : 개선된 접합방식을 도출하기 위한 3차원 비선형 해석 (Developments of Advanced Connection Type for Improvements of Mixed Structures(I) : 3D Nonlinear Analysis of the Various Connection Types for Deriving Advanced Connection Type)

  • 윤익중;허택녕;김문겸;조성용
    • 대한토목학회논문집
    • /
    • 제28권1A호
    • /
    • pp.89-94
    • /
    • 2008
  • 서로 다른 부재로 이루어진 혼합구조물은 불연속면인 접합부에 강도저감, 응력집중이 발생하거나 응력전달이 확실하지 않게 되므로 접합부에 대한 연구는 이미 오래전부터 다양한 방법을 통하여 연구되어 왔다. 특히 최근에 장대교량에 혼합구조를 적용하면, 경제성과 시공성이 확보되고 구조적 성능이 증가하는 것으로 알려지면서 일본, 유럽 등과 같은 선진국에서 혼합구조의 연구 및 시공이 활발히 이루어지고 있는 실정이다. 하지만 이에 대한 국내의 연구는 상대적으로 미미한 수준에 있다. 따라서 본 논문에서는 전술한 혼합구조의 접합부가 구조물 전체에 미치는 영향을 분석하기 위하여 기존에 수행된 많은 연구결과를 검토하고, 현재 가장 널리 사용되고 있는 전후면판 방식의 접합부를 갖는 혼합구조의 비선형 해석을 수행하여 그 장단점을 파악하였다. 또한, 이를 기초로 혼합구조 접합부의 성능을 개선할 수 있는 접합부 방식를 제안하고, 이를 기존의 방식과 비교분석하기 위하여 객관적인 6개의 기준을 설정하여 분석하였다. 개선된 모형으로는 형태를 개선안 모형 2개와 불연속면을 보강한 모형 1개 총 3개의 개선모형를 설정하였으며, 객관적인 비교기준으로 하중-처짐관계, 처짐곡선분포, 개구폭, 스터드축력, 소성변형 크기 및 위치, 접합부 응력분포 등을 설정하였다. 이와 같은 기준에 따라 기존 접합부 방식과 개선된 방식을 서로 비교검토한 결과, 본 논문에서 제안한 접합부 방식이 구조물의 성능개선에 큰 효과가 있는 것으로 나타났으므로 혼합구조의 새로운 접합부 방식으로 제안하였다.

수평스티프너를 이용한 철골 기둥-보 약축접합부 상세 개발에 관한 연구 (Development of Beam-to-Column Connection Details with Horizontal Stiffeners in Weak Axis of H-shape Column)

  • 이도형;함정태;김성배;김영호;김상섭
    • 한국강구조학회 논문집
    • /
    • 제16권5호통권72호
    • /
    • pp.641-652
    • /
    • 2004
  • 철골 기둥-보 강축 접합부에 대한 연구는 그 동안 국내외에서 오랜 기간 연구가 진행되어 내진성능 및 접합부의 강도를 개선시킬 수 있는 많은 접합 형식이 개발되어 사용 중에 있으나, 약축 접합 형식에 대한 연구는 거의 없는 실정이다. 또한 현재 국내에서는 시공성을 고려하여 기존의 브라켓형식 용접 접합부를 선호하고 있으나, 용접량이 많아 취성적인 거동이 우려되며 과대 설계된 경향이 있다. 본 연구의 실험 결과에서 기존 브라켓 형식 용접접합은 용접량이 과도한 것으로 나타났으며, 기둥 웨브와 보의 웨브의 용접은 불필요한 것으로 판단된다. 그리고 본 연구에서 제안한 새로운 기둥-보 약축 접합형식들에 대한 실험 결과에서 기존 브라켓형식 용접접합보다 우수한 내력 및 연성을 보유하여 구조적으로 안전함을 확인할 수 있었다.

치과위생사 성격유형에 따른 업무 스트레스 연구 (The study on the job stress of dental hygienists by the personality type)

  • 정미희
    • 한국치위생학회지
    • /
    • 제3권1호
    • /
    • pp.45-57
    • /
    • 2003
  • The purpose of this study is to identify the factors affecting job stress and relationship between dental hygienists personal characteristics and them. Final purpose of this study provides the basic data of dental hygienists interventions to help dental hygienists' job stress reduction program. Data were drawn from a convenient sample of 401 dental hygienists who were working for dental clinic, general hospitals, and university hospitals in Seoul and Kyungi areas. The results were analyzed with spsswin 10.0 and the conclusion is as follow: 1. General special quality distribution of dental hygienist is 25-59 and respondent who work in the dentist's office by maiden less than was most. 2. The dental hygienists' job stress was 2.68, it indicates considerably high compare to normal another groups. 3. 'By work, feel fatigue' appeared highest by 3.60 in 5 points full marks from item of business amount connection stress. 4. Only business amount connection stress was expose that is significant in relation with job stress and individual character type. 5. Age, dependent's number, faith, character type variable appeared to keep in mind for connection factor which influence in job stress. 6. Job stress connection factor by character type was expose by variable savages significant thing 'that do work year all as dental hygienist' in A type.

  • PDF

Influence of connection detailing on the performance of wall-to-wall vertical connections under cyclic loading

  • Hemamalini, S.;Vidjeapriya, R.
    • Advances in concrete construction
    • /
    • 제9권5호
    • /
    • pp.437-448
    • /
    • 2020
  • In high rise buildings that utilize precast large panel system for construction, the shear wall provides strength and stiffness during earthquakes. The performance of a wall panel system depends mainly on the type of connection used to transfer the forces from one wall element to another wall element. This paper presents an experimental investigation on different types of construction detailing of the precast wall to wall vertical connections under reverse cyclic loading. One of the commonly used connections in India to connect wall to wall panel is the loop bar connection. Hence for this study, three types of wet connections and one type of dry connection namely: Staggered loop bar connection, Equally spaced loop bar connection, U-Hook connection, and Channel connection respectively were used to connect the precast walls. One third scale model of the wall was used for this study. The main objective of the experimental work is to evaluate the performance of the wall to wall connections in terms of hysteretic behaviour, ultimate load carrying capacity, energy dissipation capacity, stiffness degradation, ductility, viscous damping ratio, and crack pattern. All the connections exhibited similar load carrying capacity. The U-Hook connection exhibited higher ductility and energy dissipation when compared to the other three connections.

신형상 메카니컬패스너를 사용한 엔드플레이트 형식 보-기둥 접합부의 변형성능 (Deformation Capacity of Endplate-type Beam-to-Column Connection with New Type Mechanical Fasteners)

  • 이승재
    • 한국공간구조학회논문집
    • /
    • 제6권3호
    • /
    • pp.123-130
    • /
    • 2006
  • 본 연구에서는 기존의 고력볼트의 축부절삭 가공방법을 이용한 신형상 메카니컬패스너를 개발하였다. 개발된 신형상 메카니컬패스너를 엔드플레이트 형식의 보-기둥 접합부에 적용하여 변형능력 및 강도특성에 대한 재하실험 및 유한요소법에 의한 수치해석을 수행하였다.

  • PDF

체결력을 고려한 내부 및 외부연결형 임플란트의 반복 하중에 대한 풀림 연구 (Loosening behavior of Internal and External Connection Dental Implants under Cyclic Loads Considering Pre-fastening Force)

  • 이용우;장용훈
    • Tribology and Lubricants
    • /
    • 제37권4호
    • /
    • pp.136-143
    • /
    • 2021
  • This paper presents the loosening behavior that occurs after the application of an external load to internal and external connection types of dental implants using the finite element method. We use fastening force between an abutment and a fixture to clamp the dental implant system; however, loosening and breakage may occur owing to cyclic external loads. In this study, we considered the initial fastening condition in the pre-load analysis and then investigated the change in stress and contact surface status when applying external loads. After the application of the initial fastening load, we verified that the internal connection-type model exhibited a relatively lower stress distribution than that of the external connection-type one. Moreover, we found that the former model showed a lower stress concentration after the application of the external load. In addition, after the application of this load, we found that the higher the shear load acting on the implant system, the higher the possibility of loosening. The study results showed the change in stress distribution and contact surface according to the connection type of the dental implants and the phenomenon of loosening by cyclic loads. We expect that the results of this study will be useful for the study of reliability and design of dental implant systems.

PC 전단벽 건식접합부에 관한 실험연구 (An Experimental Study on Dry-Connection for Precast Concrete Shear Walls)

  • 홍성걸;임우영
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.21-24
    • /
    • 2005
  • In this study, new methods of PC panel connection using 'ㄷ'type steel connection is proposed for highly seismic zone. A study was carry out to investigate the connection behavior subjected to cyclic inelastic loading. Three planar type and two T type PC wall will be tested. The variables will be examined were the shear reinforcement existence of top and bottom walls. The specimens will be tested only reverse cyclic loading in accordance with a prescribed displacement history. To transfer the shear strength shear key set up between top and bottom wall. Failure mode, behavior, ductility and energy dissipation capacity of the specimens constructed by new connections wll be compared with those of monolithic walls and Han's(Han, Jun Hee, Seoul National University) model.

  • PDF

개선된 접합부 방식을 갖는 혼합구조의 비선형 거동 (Nonlinear Behaviors of Mixed Structure Considering Advanced Connection Types)

  • 허택녕;윤익중;김문겸;조성용;심별
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2007년도 정기 학술대회 논문집
    • /
    • pp.677-682
    • /
    • 2007
  • Nonlinear analysis of mixed structures is carried out by utilizing contact elements of a general finite element analysis computer program(ABAQUS). The present analysis focuses on the enhancing behaviors of mixed structure's connection type. Main 2 issues are related with discontinuity which reduce the stiffness of structure and proposing enhanced connection type. To validate the present study approaching 2 way, analytic one and experimental test.

  • PDF