• Title/Summary/Keyword: connection type

Search Result 1,446, Processing Time 0.027 seconds

Power-hardware-in-the loop simulation of PMSG type wind power generation system (PMSG 타입 풍력 발전시스템의 Power-hardware-in-the loop simulation)

  • Hwang, Chul-Sang;Kim, Gyeong-Hun;Kim, Nam-Won;Park, Jung-Do;Yi, Dong-Young;Lee, Sang-Jin;Park, Min-Won;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1296-1297
    • /
    • 2011
  • This paper deals with a power-hardware-in-the loop simulation (PHILS) of permanent magnet synchronous generator (PMSG) type wind power generation system (WPGS) using a real hardware which consists of a motor generator set with motor drive, real time digital simulator (RTDS), and back-to-back converter. A digital signal processor (DSP) controls the back-to-back converter connected between the back-to-back converter and the RTDS. The proposed PHILS can effectively be applied to demonstrate the operational characteristics of PMSG type WPGS under grid connection.

  • PDF

Design of sandwich type piezoelectric resonator for underwater acoustic transducer (수중 음향 트랜스듀서용 샌드위치형 압전 진동체의 설계)

  • 조치영;김인수;윤형규
    • Journal of KSNVE
    • /
    • v.5 no.4
    • /
    • pp.577-583
    • /
    • 1995
  • The sandwich type piezoelectric resonator is widely used for the acoustic sources of underwater acoustic transducers, whose important design parameters are shapes, materials, dimensions and supporting methods. Practical design method of resonators consists of manufacturing, experiments and modification so that it requires much time and expenses. In this study, an analytical design method of sandwich type piezoelectric resonators is presented based on the nonlinear optimization technique. The proposed method is applied to the design of an example resonator model in order to maximize the output powers. For the investigation of performance according to the division and their electrical connection, three types of resonators are manufactured. In addition, their dynamic characteristics such as electrical admittance and transmitting voltage response are measured and compared.

  • PDF

Fault Current Limiting Characteristics of Series Connected Flux-Lock Type Superconducting Fault Current Limiters (직렬연결된 자속구속형 초전도 사고전류 제한기의 사고전류제한 특성)

  • Lim, Sung-Hun;Kim, Jae-Chul
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.197-199
    • /
    • 2007
  • To apply the flux-lock type SFCL into power system, its current and voltage ratings are required to increase. Especially, in case of series connection of SFCLs, the countermeasure for simultaneous quenches must be considered. The structure, which each flux-lock type SFCL unit was wound in series on the same iron core, can induce the simultaneous quench of superconducting elements. Through the fault current limiting experiment for the suggested structure, it was confirmed that the even voltage burden among the superconducting elements comprising SFCLs could be made.

  • PDF

Current Limiting Characteristics of a Flux-lock type SFCL with Secondary Windings Connected to the Superconducting elements in parallel (초전도 소자 병렬 연결에 따른 자속구속형 한류기의 전류제한 특성)

  • Park, Hyoung-Min;Cho, Yong-Sun;Choi, Hyo-Sang;Oh, Geum-Kon;Jung, Soo-Bok;Lim, Sung-Hun;Choi, Myong-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.229-230
    • /
    • 2007
  • We investigated the quench characteristics of a superconducting element, two superconducting elements in order to increase the current capacity of flux lock type SFCL. The flux-lock type SFCL consisted of the transformer with a primary winding and a secondary winding connected in parallel, and the superconducting element was connected with secondary winding in series. The applied voltage at that time was 160 ${\sqrt{3}}$. We found that the parallel connection between the superconducting elements increased the power capacity and let quench characteristics improve through their mutual linkage.

  • PDF

Properties of a Hybrid Type Superconducting Fault Current Limiter using YBa2Cu3O7 Films (YBa2Cu3O7 박막을 이용한 하이브리드형 초전도 사고전류제한기의 특성)

  • Choi, Hyo-Sang;Cho, Yong-Sun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.4
    • /
    • pp.391-397
    • /
    • 2006
  • We present investigations of a hybrid type superconducting fault current limiter (SFCL), which consists of transformers and resistive superconducting elements. The secondary windings of the transformer were separated into several electrically isolated circuits and linked inductively with each other by mutual flux, each of which has a superconducting current limiting element of $YBa_2Cu_3O_7$ (YBCO) stripes as a current limiting element. Simple connection in series of the SFCL elements tends to produce ill-timed quenching because of power dissipation unbalance between SFCL elements. Both electrical isolation and mutual flux linkage of the elements provides a solution to power dissipation unbalance, inducing simultaneous quench and current redistribution of the YBCO films. This design enables to increase the voltage rating of SFCL with given YBCO stripes.

An Analysis of the Transition of Architectural Data on the Intelligent Office Building in Korea (국내(國內) 인텔리전트 사무소(事務所) 건물(建物)의 건축계획(建築計劃) 관련지표(關聯指標) 추이(推移) 분석(分析))

  • Byun, Gye-Sung
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.2 no.1
    • /
    • pp.24-31
    • /
    • 2002
  • The purpose of this study was to analyze the transition on architectural data such as valid indoor length, module, ratio of core, floor height, ceiling height and the type of structured cabling system according to the intelligent building grade through case study of the intelligent office buildings constructed in Korea since 1980. The results of this study were as follows. The average floor height was 3.80m, and it was higher in proportion to the IB grade. The average ceiling height was 2.57m, and it didn't have connection with the IB grade. The module of high frequency in application was $3.0{\times}3.0m$, and it showed 25% in the application frequency. The average valid indoor length was 12.27m. The average ratio of core was 24.49%. The type of high frequency in application for the structured cabling was Access Floor Type, and it showed 31% in the application frequency.

  • PDF

An Experimental Study on the Behavior of Square Hollow Steel Section T-joints to be fillet-welded without Reinforcement (무보강 모살용접 각형강관 T형 접합부의 거동에 관한 실험적연구( II ))

  • Bae, Kyu-Woong;Moon, Tae-Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.8 no.3 s.28
    • /
    • pp.35-45
    • /
    • 1996
  • The purpose of this paper is to investigate experimentally the strength and deformation of T-joints to improve the structural behavior of truss connection consisted in square hollow steel section. There are two-types to be changed in T-joint shape. One type is TP-series that a brace member is rotated to 45 degree, another type is TR-series that a chord member is rotated to 45 degree. The most important results obtained from the 2nd experiment on the T-joints is as follow; The yielding strength and initial stiffness of TP-series increase more than a current type(TS-series) in $0.6{\leq}{\beta}(d/D){\leq}0.7(0.85{\leq}{\beta}$'$(={\sqrt2}{\cdot}{\beta}){\leq}1.0)$.

  • PDF

A Study of Concentric-Neutral Line Voltage Increase Related by Pole and Cable Joint When Lightening Overvoltage Injected in Combined Distribution Line (혼합 배전선로에 직격낙뢰시 전주와 케이블직선접속재가 케이블 동심중성선 전위상승에 미치는 영향)

  • Jeon, Yong-Joo;Jeon, Myung-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.6
    • /
    • pp.702-707
    • /
    • 2018
  • In case of Lighting occurs in Domestic combined distribution line, normally the voltage for the neutral line increase dramatically. General connection for underground cable is bundled common earth type so the lightning over voltage increase at the concentric-neutral line is not big enough to give impact on cable sheath. But in case of Non bundled common earth type it is necessary to analyze the phenomena on cable sheath caused by lightening overvoltage. Especially pole and cable joint are the core factor to consider. In this paper concrete pole and cable joint were evaluated in case of Non bundled common earth type combined distribution Line. EMTP simulation model has been designed and several case study were made. Also several experimental test were made to verify the simulation result.

How Residential Mobility Influences Material and Experiential Purchases

  • Sujeong Hong
    • Asia Marketing Journal
    • /
    • v.24 no.4
    • /
    • pp.161-168
    • /
    • 2023
  • With the increased mobility within nations, relocation has become a frequent and regular occurrence in modern life. However, we know little about how residential mobility affects purchase type. How does residential mobility affect our purchase behavior? This research explores the relationship between residential mobility and preference of purchase type, with psychological processes. The study primed participants with either a high or low mobility mindset to investigate the effect of mobility on consumption style in U.S. and South Korean. The results of the study confirm that the consideration of residential mobility shifts consumers' preferences toward material goods and experiences. In addition, results also indicate that the connection between mobility and purchase type was mediated by autonomy and moderated by cultural factor. Lastly, the theoretical and practical implications are covered.

Seismic Performance of Column-Footing Connection of Modular Pier using CFT (CFT를 이용한 모듈러 교각 기둥-기초 연결부의 내진성능)

  • Kim, Ji Young;Kim, Ki Doo;Ma, Hyang Wook;Chung, Chul-Hun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.1
    • /
    • pp.73-85
    • /
    • 2014
  • The CFT (Concrete Filled steel Tubes) column-footing connection is cast-in-place embedded type which provides simple construction procedure, low cost, and superior structural performance. In this study, CFT column-footing connection of modular pier is proposed and structural performance is evaluated by experimental tests. To evaluate structural performance of the CFT column-footing connection, a series of experimental tests were performed for the 4 specimens with different embedded depth. As a result of the quasi-static test, the specimen with 0.6D (0.6 times the outside diameter of steel tube) embedded depth showed relatively low ductility than other specimens with larger embedded depth due to cone failure of base concrete occurred during the lower loading step. On the contrary, cone failure of the base concrete was not observed in the specimens with larger embedded depth than 0.9D, but typical flexural failure in lower part of CFT column was observed. With the analyses of force-displacement curve, displacement ductility, and energy dissipation capacity, it is concluded that the rational range of embedded depth of the CFT column-footing connection is from 0.9D to 1.2D in view of good seismic performance.