• Title/Summary/Keyword: connection method

Search Result 2,946, Processing Time 0.033 seconds

Dynamic resource reservation scheme for connection rerouting on ATM-based PCN (ATM-based PCN에서의 연결재라우팅을 위한 유선망자원 예약방안)

  • 장경훈;심재정;김덕진;강경훈
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.2
    • /
    • pp.11-20
    • /
    • 1997
  • It is a recent trend that mobile communications and PCS are intergrated into the broadband network. Broadband mutlimedia traffic will be transported over the integrated network. In this paper, we propose a connection re-routing method for fast inter-switch hadoffs and dynamic resurce reservation scheme, which is based on the proposed re-routing method, for the ATM-based personal communications network. To reduce the delay for re-routing method, for the ATM-based personal communications network. To reduce the delay for re-routing, the proposed re-routing method is to reserve VPI/VCIs for possible inter-swich handoff calls in advance. Our reservation scheme is to statistically reserve the fixed resources for possible inter-switch handoff calls, according to the QoS of the handoff calls. The simmulation reslts show that our proposed scheme satisfies the required QoS of handoff calls and keep the dropping probability of handoff calls lower than other schemes.

  • PDF

Soft Start-up Characteristics Analysis of Squirrel Cage Induction Generator (농형 유도 발전기의 소프트 기동 특성 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.1
    • /
    • pp.103-107
    • /
    • 2016
  • In general, the voltage stability of induction generator is lower than synchronous generator. Induction generator has a number of advantages over the synchronous generator on the side of price and maintenance. So Induction generator has been applied to the small hydroelectric power of low output. Induction generator usually generates a high current during grid connection. The high current that occurs during grid connection can cause a voltage drop in the system. In order to increase the supply of the induction generator, it is necessary to propose a method of reducing high current. This paper proposes some method of the soft start to reduce voltage drop caused by the large starting current. soft-start method has high voltage drop effect than direct start method, control of firing angle can be increased the voltage drop effect.

New Simulation Method of Flashover Rate by Connection of EMTP and MATLAB

  • Seo, Hun-Chul;Han, Joon;Choi, Sun-Kyu;Lee, Byung-Sung;Kim, Chul-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.3
    • /
    • pp.602-608
    • /
    • 2016
  • Because of the random characteristics of lightning, the Monte Carlo method is applied to estimate the flashover rate due to lightning, however, the simulations using previous methods are difficult to both beginner and expert in power corporations. Therefore, this paper proposes the new and easy method to simulate the flashover rate by connection of electromagnetic transients program (EMTP) and MATLAB. The magnitude of a lightning strike is based on a curve measured in the field, while the classification of direct and indirect lightning depends on the striking distance. In a Korean distribution system, the flashover rate induced by lightning is simulated using proposed method. Simulations of the footing resistance according to the existence of an overhead ground wire (OHGW) are performed and the simulation results are discussed. The simulation results are compared with findings obtained with the IEEE Flash 2.0 program.

A Study on the Fuse Sizing Technique for the Protection of Satellite Power System (인공위성 전력 시스템 보호를 위한 퓨즈 선정 기법 연구)

  • Jeon, Hyeon-Jin;Lim, Seong-Bin;Lee, Sang-Rok
    • Aerospace Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.1-6
    • /
    • 2012
  • Power system in satellite is protected by installing fuses, LCLs (Latching Current Limiters), etc. between satellite power supply and loads. In this paper, the fuse sizing technique for satellite power system protection is addressed. Detailed fuse sizing method is explained and it is shown that the single fuse connection method is mathematically subordinated to the parallel fuse connection method. In addition, appropriate fuse selection method is newly suggested under a situation where exact current characteristics of a load connected to a fuse is unknown.

A Study Of Parallel Characteristics Of 50[W] Virtual Implement of 50[W]Solar Cell modules Using Droop-Method (Droop Method를 이용한 50[W]급 태양전지 가상구현 시스템의 병렬연결 출력특성에 대한 연구)

  • Lee B.I.;Lee S.Y.;Oh B.W.;Jung B.H.;Choe G.H.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.692-695
    • /
    • 2003
  • Generally, photovoltaic system is composed with several solar cell modules. For increasing power of photovoltaic systems, serial and parallel connection needed. A Desirable characteristic of a parallel supply system is that individual converters share the load current equally and stably. The current sharing(CS) can be implemented using two approaches. The first one, known as a droop method, relies on the high output impedance of each converter. and The second approach, known as active current-sharing techniques. In this paper, using droop method at parallel connection with it's convenience and simplicity.

  • PDF

Uncertainty assessment of industrial platinum resistance thermometers for different lead-wire connection methods (산업용 백금저항온도센서의 결선방식에 따른 측정불확도 평가방법)

  • Kim, Yong-Gyoo;Gam, Kee-Sool;Yang, In-Seok
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.322-326
    • /
    • 2009
  • To estimate the measurement uncertainty for industrial platinum resistance thermometers(IPRTs) made with 3-wire connection, the immersion temperature profile was investigated using a liquid bath. Two types of IPRTs having lead wires made of silver and nickel were constructed and the immersion profiles were measured at temperatures from -50 $^{\circ}C$ to 250 $^{\circ}C$ using 3-wire and 4-wire method. As immersion depth and temperature increased, the resistances measured by 3-wire method increased linearly but not for 4-wire method. To calibrate a 3-wire IPRT, the immersion effect must be accounted for. We propose a linear equation to assess correctly the measurement uncertainty.

A Study on the Characteristics of Two Dimensional Stress Wave Propagation Using the Distinct Element Method (개별요소법에 의한 이차원 응력파의 전달특성에 관한 연구)

  • 오금호;김문겸;원용호
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1998.04a
    • /
    • pp.406-413
    • /
    • 1998
  • The distinct element method is improved to consider the charateristics of stress wave propagation in media involving the discontinuous faces. The distinct element method has many advantages to analyse the characteristics of the reflection, refraction and deflection of the waves in nonhomogeneous media. The double-suing connection system is adopted instead of the single-spring connection system because the distinct element cannot be used for analysing the contact behavior between the different materials by only one contact spring. For the verification of the improved code, the results of the numerical analysis are compared with that of the photoelastic experiments which are one or two dimensional wave propagation problem of the nonhomogeneous media including the different accoustic impendence material or voids. It is shown that the characteristics of the stress wave propagation in nonhomogeneous media can be simulated appropriately using the improved distinct element method.

  • PDF

Systematic Analysis of Bandgap Evolution of Conjugated Polymers

  • Hong, Sung Y.
    • Bulletin of the Korean Chemical Society
    • /
    • v.16 no.9
    • /
    • pp.845-850
    • /
    • 1995
  • A systematic method is presented to analyze the bandgaps of conjugated polymers in terms of geometrical relaxations and electronic effect of moieties using the equation of Eg=ΔEδr + ΔE1-4 + ΔEel. The relationship between ΔEδr and δr is derived from trans-PA and is transferred to other conjugated polymeric systems. By applying this method to heterocyclic polymers, very useful information is obtained to understand the evolution of bandgaps of PT, PPy and PF in connection with the chemical structures and electronic effect of the heteroatoms. We believe that this method is very helpful to understand the evolution of bandgaps of various conjugated polymers in connection with the chemical structures and electronic effect of moieties. Also, the method is expected to provide valuable information to design a small bandgap polymers.

Condensation of independent variables in free vibration analysis of curved beams

  • Mochida, Yusuke;Ilanko, Sinniah
    • Advances in aircraft and spacecraft science
    • /
    • v.3 no.1
    • /
    • pp.45-59
    • /
    • 2016
  • In this paper, the condensation method which is based on the Rayleigh-Ritz method, is described for the free vibration analysis of axially loaded slightly curved beams subject to partial axial restraints. If the longitudinal inertia is neglected, some of the Rayleigh-Ritz minimization equations are independent of the frequency. These equations can be used to formulate a relationship between the weighting coefficients associated with the lateral and longitudinal displacements, which leads to "connection coefficient matrix". Once this matrix is formed, it is then substituted into the remaining Rayleigh-Ritz equations to obtain an eigenvalue equation with a reduced matrix size. This method has been applied to simply supported and partially clamped beams with three different shapes of imperfection. The results indicate that for small imperfections resembling the fundamental vibration mode, the sum of the square of the fundamental natural and a non-dimensional axial load ratio normalized with respect to the fundamental critical load is approximately proportional to the square of the central displacement.

Shape Decision and Shear Experiment of High-Shear Ring Anchor for Steel-Concrete Connection (강재 접합용 고전단 링앵커의 형상 개발과 전단실험)

  • Jeon, Sang Hyeon;Kim, Mun-Kil
    • Journal of Urban Science
    • /
    • v.7 no.2
    • /
    • pp.29-36
    • /
    • 2018
  • The demand for reinforcement in accordance with remodeling, seismic retrofit, and change of use of the existing structure is increasing. Originally, shear wall new and extension method has been adopted a lot as seismic retrofit methods. Recently, dry seismic retrofit method that uses structural steel is mostly adopted in order to minimize spatiotemporal aspect and underpinning that occurs when a construct shear wall. We redesigned the form of old and new concrete joint high-shear ring anchor that was developed according to recent reinforcement method and determined construction method. Shear tests were performed on High-Shear Ring Anchor for steel-concrete connection. Comparison with 4 tests shows that the average of test-to-prediction ratios is 1.01.