• Title/Summary/Keyword: connecting

검색결과 3,788건 처리시간 0.026초

엔진 커넥팅로드의 좌굴평가에 대한 연구 (Study of Buckling Evaluation for the connecting rod of the engine)

  • 이문규;문희욱;이형일;이태수;신성원;장훈
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.677-680
    • /
    • 2004
  • This study investigates the buckling evaluation of connecting rods used in the diesel engine through finite element analysis. The Rankine formula, which is modified from classical Euler‘s formula, has been widely accepted in automotive industry to evaluate the buckling of connecting rods. Apparently, this formula is most suitable for the straight and idealized rod shape, and over-simplifies the geometric complexity associated with connecting rods. The subspace iteration method in FEA is used to predict the critical buckling stress of a connecting rod with certain slenderness ratio. To create models with various slenderness ratios for shank portion in the rod, the automatic meshing preprocessor was implemented. Results from FEA were verified by the experiments, in which the embedded strain gages measured for the connecting rod running at 4000rpm. The result indicates that the buckling prediction curve through FEA and experiment is effectively different from the curve of classical Rankine formula.

  • PDF

Seismic mitigation of an existing building by connecting to a base-isolated building with visco-elastic dampers

  • Yang, Zhidong;Lam, Eddie S.S.
    • Structural Engineering and Mechanics
    • /
    • 제53권1호
    • /
    • pp.57-71
    • /
    • 2015
  • This study investigates the feasibility of retrofitting an existing building by connecting the existing building to a new building using connecting dampers. The new building is base-isolated and viscoelastic dampers are assigned as connecting dampers. Scaled models are tested under three different earthquake records using a shaking table. The existing building and the new building are 9 and 8 stories respectively. The existing building model shows more than 3% increase in damping ratio. The maximum dynamic responses and the root mean square responses of the existing building model to earthquakes are substantially reduced by at least 20% and 59% respectively. Further, numerical models are developed by conducting time-history analysis to predict the performance of the proposed seismic mitigation system. The predictions agree well with the test results. Numerical simulations are carried out to optimize the properties of connecting dampers and base isolators. It is demonstrated that more than 50% of the peak responses can be reduced by properly adjusting the properties of connecting dampers and base isolators.

온도 변화의 영향을 고려한 커넥팅 로드 베어링의 EHL 해석 (EHL Analysis of connecting Rod Bearings Considering Effects of Temperature Variation)

  • 김병직;김경웅
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2000년도 제31회 춘계학술대회
    • /
    • pp.114-120
    • /
    • 2000
  • EHL analysis of connecting rod bearing is proposed which includes effects of temperature variation in lubrication film. Lubrication film temperature is treated as a time-dependent, two-dimensional variable which is averaged over the film thickness, while connecting rod big end temperature is assumed to be time-independent and three-dimensional. It is assumed that a portion of the heat generated by viscous dissipation in the lubrication Him is absorbed by the film itself, and the remainder flows into the bearing surface. Mass-conserving cavitation algorithm is applied and the effect of variable viscosity is included to solve the Reynolds equation. Simulation results of the connecting rod bearing of internal combustion engine are presented. It is shown that the temperature variation has remarkable effects on the bearing performance. It is concluded that the EHL analysis considering effects of the temperature variation is strongly recommended to predict the bearing performance of connecting rod big end On internal combustion engine.

  • PDF

유량 보존 경계 조건을 적용한 커넥팅 로드 베어링의 EHL 해석 (EHL Analysis of Connecting Rod Bearings Using Mass-Conserving Boundary Condition)

  • 김병직;김경웅
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1998년도 제27회 춘계학술대회
    • /
    • pp.212-217
    • /
    • 1998
  • Reynolds equation, which describes behavior of fluid film in journal bearing, basically satisfies mass conservation. But, boundary conditions usually used with this equation, e.g. half Sommerfeld or Reynolds boundary conditions, cannot fulfill this natural law of conservation. In the case of connecting rod bearing, where applied load is dynamic and its magnitude is relatively large, such unrealistic boundary conditions have serious influence on calculation results, especially on lubricant flow rate or power dissipation which are important parameters in thermal analysis. Another important factor in the analysis of connecting rod bearing is elastic deformation of bearing support structure which is relatively flexible. In this paper, EHL analysis of connecting rod beating is performed using mass-conserving boundary condition. Elastic deformation of bearing support structure and application of mass-conserving boundary condition have significant effects on the performances of connecting rod bearing.

  • PDF

복합 건축물 연결 통로에서의 기류형성에 관한 수치적 해석 연구 (A NUMERICAL STUDY ON FLOW PATTERN IN CONNECTING PASSAGEWAY OF A COMPOSITE BUILDING)

  • 전병진;장병윤;최형권
    • 한국전산유체공학회지
    • /
    • 제15권3호
    • /
    • pp.81-86
    • /
    • 2010
  • In this paper, a three-dimensional numerical study on flow pattern in winter along connecting passageway of a composite building was conducted using a commercial CFD package. The incompressible Navier-Stokes equation coupled was solved by using SIMPLE algorithm in order to find steady solutions. It was shown that a upward flow is generated inside the building in winter due to buoyancy effect and that the air inside connecting passageway flows from the shorter building to the taller one regardless of the slope of the passageway. Further, it was found that the magnitude of air velocity inside connecting passageway increases as the uphill slope to the taller building increases and decreases as the downhill slope to the taller one increases, although the variation in the magnitude of fluid velocity is not substantial. Lastly, it was shown that the maximum air velocity inside connecting passageway is less than the allowable limit for all the cases considered in this study.

커넥팅로드 소단부 파단의 해석 (Failure Analysis of Connecting Rod at Small End)

  • 민동균;전병희;김낙수
    • 대한기계학회논문집
    • /
    • 제19권2호
    • /
    • pp.382-390
    • /
    • 1995
  • Failure of connecting rod in automotive engine may cause catastrophic situation. The corner radius at small end has an effect on stress raising. To investigate the stress distribution in connecting rod during operation, the finite element analysis was used by giving possible maximum tension and compression. Excessive sizing after forging connecting rod may result in the tensile residual stress which lower the fatigue life and cause premature failures. It was shown that when the sizing amount is too large, the location of high tensile residual stress coincide with that of high stress amplitude during operation through the elastic-plastic finite element analysis. The endurance limit moves down due to the surface finish and decarburization, which combines with the movement of resultant stress points to dangerous range. It was concluded that the precise control of sizing and enough corner radius are necessary to a reliability of connecting rod.

온도 변화의 영향을 고려한 커넥팅 로드 베어링의 EHL 해석 (EHL Analysis of Connecting Rod Bearings Considering Effects of Temperature Variation)

  • 김병직;김경웅
    • Tribology and Lubricants
    • /
    • 제17권3호
    • /
    • pp.228-235
    • /
    • 2001
  • EHL analysis of connecting rod bearing is proposed which includes effects of temperature variation in lubrication film. Lubrication film temperature is treated as a time-dependent, two-dimensional variable which is averaged over the film thickness, while connecting rod big end temperature is assumed to be time-independent and three-dimensional. It is assumed that a portion of the heat generated by viscous dissipation in the lubrication film is absorbed by the film itself, and the remainder flows into the bearing surface. Mass-conserving cavitation algorithm is applied and the effect of variable viscosity is included to solve the Reynolds equation. Simulation results of the connecting rod bearing in internal combustion engine are presented. It is shown that the temperature variation has remarkable effects on the bearing performance. It is concluded that the EHL analysis considering effects of the temperature variation is strongly recommended to predict the connecting rod bearing performance in internal combustion engine.

인천국제공항철도와 기존 철도의 효율적인 연계방안 (Effective Connecting Methods Between Incheon International Airport Railroad and Existing Railroads)

  • 한우진
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2002년도 추계학술대회 논문집(I)
    • /
    • pp.253-258
    • /
    • 2002
  • The Incheon International Amort Railroad (IIAR) is the railroad that connects Incheon International Airport, Gimpo Airport and Seoul Station. IIAR is now under construction, and it will be finished to Gimpo Amort by 2006, to Seoul Station by 2008. But IIAR is not only so late to start but also has no discussion about effective connecting methods to existing railroads and fine operation plan. Therefore, after IIAR opens, it is possible for IIAR to lose to limousine bus using highway. So, this paper proposes 4 effective connecting methods for IIAR - (1) Shuttle transport, (2) Short-distance connecting transport (Inside IIAR, Seoul Subway Line 9, 'Han-River line') (3) Mid-distance connecting transport (Jung-ang, Tae-baek, Young-dong line) (4) Long-distance connecting transport (Korean Train express (korean high speed railroad)) These methods can increase the connectivity of IIAR with existing railroads and the competition power of IIAR against highway.

  • PDF

하이드로 임베딩시 체결용 연결요소의 형상 최적화 연구 (Studies on the Shape Optimization of Connecting Element for Hydro-Embedding)

  • 김봉준;김동규;김동진;문영훈
    • 소성∙가공
    • /
    • 제14권9호통권81호
    • /
    • pp.756-763
    • /
    • 2005
  • The applicability and productivity of hydroforming process can be increased by combining pre- and post-forming processes such as the bending, piercing and embedding process. For the fabrication of automotive parts, the hollow bodies with connecting nuts are widely used to connect parts together. Hollow body with connecting nuts has been conventionally fabricated by welding nuts or screwing in autobody screws. It requires multiple steps and devices fur the welding and/or screwing Therefore in this study, hydro-embedding process that combines the hydraulic embedding of connecting element(nut) with hydroforming process is investigated. Studies on the hydro-embedding technology have been performed to optimize the shape of the connecting element by analyzing the deformed mode of the embedded tube The effects of the shape of the screw tip, screw thread and shape of thread on the connection force between the tube and the connecting element have been investigated to optimize the shape of connecting element. Finite element analysis has also been performed to provide deformation behaviors of the tube surrounding a hole produced by hydro-embedding.

도시철도 통합접지망에서의 위험전압에 따른 연접접지봉의 최적 분기간격에 관한 연구 (A Study on the Optimal Divergence Spacing of the Connecting Grounding Rod to the Dangerous Voltage in the Global Earthing Network of Urban Rail Transit)

  • 정호성;박영;김형철;김진희;김재문;조대훈
    • 전기학회논문지
    • /
    • 제61권9호
    • /
    • pp.1374-1379
    • /
    • 2012
  • Urban rail transit tends to global grounding system in order to control ground potential rise and potential differences between electric equipments. In addition, global grounding system can discharge the large capacity surge current to the ground safely. Since some railway electric equipments are installed all section of line, the global grounding system connected with the connecting grounding wire is more effectively. However, if the fault occurred in the connecting grounding wire area, some dangerous voltage is generated. So, the installation of additional grounding rod will be required. In this study, the global grounding system is simulated using CDEGS program to analyze the divergence spacing of additional ground rod depending on dangerous electric potential characteristics. Grounding net of the each station is modelled in depending on the size of the platform, and the spacing of the connecting grounding rod are compared 50m, 100m, 250m and 400m. Simulation results considering of earth resistivity and underground condition of the connecting grounding wire, spacing of the connecting grounding rod is that less than 250m to spacing of the ground rod was appropriately confirmed.