• 제목/요약/키워드: connected bridge

검색결과 431건 처리시간 0.023초

단상 계통 연계형 풀브릿지 인버터의 스위치 손실 모의 및 분석 (Simulation and Analysis of Losses of Switching Device for Single Grid-connected Full Bridge Inverter)

  • 손명수;임현지;조영훈
    • 전력전자학회논문지
    • /
    • 제23권4호
    • /
    • pp.294-297
    • /
    • 2018
  • This paper analyzes the losses of the switching device for a full bridge inverter connected to the grid. As the development of power conversion system, losses are dominant factors in judging the efficiency of a system. The losses of a switching device can be divided into switching loss and conduction loss, both of which can be estimated by analyzing periodic switching waveform. The switching loss is generated when the switch is turned on and off, while the conduction loss is generated when the switch is turned on. The estimated losses of the MOSFET switch are compared with the simulation results.

SKY-BRIDGE로 연결된 건물의 진동제어 (Vibration Control of Buildings Connected by a Sky-Bridge)

  • 류진국;김진구
    • 한국전산구조공학회논문집
    • /
    • 제17권2호
    • /
    • pp.203-213
    • /
    • 2004
  • 본 연구에서는 최상층에 설치된 연결교량과 두 건물의 연결부에 점탄성감쇠기 (Viscoelastic Dampers, VED)를 설치하여 지진에 의한 연결된 건물의 응답을 저감하는 방법에 대해서 연구하였다. 제안된 방법의 적용성을 백작잡음하중에 대한 2자유도계 구조물의 RMS (root-mean-squared) 응답을 통하여 검토한 후, 점탄성감쇠기의 크기변화에 따른 응답 감소 효과를 분석하기 위해 다양한 층수의 연결된 구조물에 대하여 지진응답 해석을 수행하고, VED 설치 전후의 최대변위, 소성힌지 분포, 잔류변위 등을 비교하였다. 해석결과에 따르면, 구조물의 응답을 최소화하는 점탄성감최기의 적정 크기가 존재하며, 연결된 두 구조물의 고유주기의 차이가 증가할수록 점탄성감쇠기의 진동제어 효과가 커진다는 것을 알 수 있다.

A CMOS Complementary Bridge Rectifier for Driving RFID Transponder Chips

  • Park, Kwang-Min
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권3호
    • /
    • pp.103-107
    • /
    • 2006
  • In this paper, a CMOS complementary bridge rectifier for driving RFID transponder chips is presented. The proposed RFID CMOS complementary bridge rectifier is designed with two NMOSs at the input, which are configured by cross-connected gate structures, and two PMOSs and two NMOSs at the output, which are configured by diode-connected MOS structures. Output characteristics of the proposed rectifier are analyzed with the high frequency small-signal equivalent circuit and verified with SPICE for RFID operating frequencies of 13.56 MHz HF for ISO 18000-3, 915MHz UHF for ISO 18000-6, and 2.45 GHz microwave for ISO 18000-4. Simulation results show well-rectified and high enough DC output voltages for driving the low power microchip in the RFID transponder for the frequency range from HF to microwave. DC output voltages are dropped by only around 0.7 V from the input peak-to-peak voltages.

전압형 인버터가 연결된 새로운 방식의 SRM 컨버터 (New SRM converter connected to the voltage source inverter)

  • 장도현
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(1)
    • /
    • pp.260-264
    • /
    • 2004
  • In this paper the novel converter topology for the switched reluctance motor drives is proposed, which is composed of the minimum switch per phase and is connected to the single-phase voltage inverter for ac voltage source. The proposed converter topology is divided into two types according to the voltage source inverter of half bridge type and full bridge type. Proposed converters of two types are proposed, analyzed and compared with each other. The SRM using proposed converter maintain the hi인 efficiency though the power switches are reduced.

  • PDF

휴먼브릿지 치아보철 시술결과에 대한 고객만족도 분석 (Study On Customer Satisfaction of Dental Prosthetic Tooth Surgery by Human Bridge)

  • 김경진;조덕영
    • 보건의료산업학회지
    • /
    • 제4권1호
    • /
    • pp.11-22
    • /
    • 2010
  • The purpose of this study is to approving the usefulness on Customer Satisfaction of Human Bridge. To achieve this purpose, we conduct a survey of 385 Customer to have a new operation analysis that so-called Human Bridge. The results of this study as follow. First of all, It's appeared that dependence on mass communication has a high level Because that Some 66% of the people surveyed say that they have Human Bridge operation by mass communication. Secondly, In case of satisfaction level connected with operation, some 66% of the respondents say that it is inconvenient or not at all in the Human Bridge operation and some 81% of the respondents say that it is very healthy or the same in the gum condition. On the other hand, Some 64% of the people surveyed say that it is inconvenient or extra comfortable in the masticate their's food well. Thirdly, In case of the level of teeth shaking, Some 90% of the people surveyed say that it is no change or small to contrast beginning, and in aesthetic satisfaction after operation, a surprising 93% of the people surveyed say that it is satisfaction.

Cascaded H-Bridge Five Level Inverter for Grid Connected PV System using PID Controller

  • Sivagamasundari, M.S.;Mary, P. Melba
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제16권4호
    • /
    • pp.451-462
    • /
    • 2016
  • Photovoltaic energy conversion becomes main focus of many researches due to its promising potential as source for future electricity and has many advantages than the other alternative energy sources like wind, solar, ocean, biomass, geothermal etc. In Photovoltaic power generation multilevel inverters play a vital role in power conversion. The three different topologies, diode-clamped (neutral-point clamped) inverter, capacitor-clamped (flying capacitor) inverter and cascaded h-bridge multilevel inverter are widely used in these multilevel inverters. Among the three topologies, cascaded h-bridge multilevel inverter is more suitable for photovoltaic applications since each pv array can act as a separate dc source for each h-bridge module. This paper presents a single phase Cascaded H-bridge five level inverter for grid-connected photovoltaic application using sinusoidal pulse width modulation technique. This inverter output voltage waveform reduces the harmonics in the generated current and the filtering effort at the input. The control strategy allows the independent control of each dc-link voltages and tracks the maximum power point of PV strings. This topology can inject to the grid sinusoidal input currents with unity power factor and achieves low harmonic distortion. A PID control algorithm is implemented in Arm Processor LPC2148. The validity of the proposed inverter is verified through simulation and is implemented in a single phase 100W prototype. The results of hardware are compared with simulation results. The proposed system offers improved performance over conventional three level inverter in terms of THD.

PSC교량의 부재별 상관관계를 고려한 시스템 지진취약도 분석 (Seismic Fragility Analysis of a Bridge System Considering the Correlation of Components of the PSC Bridge)

  • 안효준;신수봉;이종한
    • 한국지진공학회논문집
    • /
    • 제25권6호
    • /
    • pp.267-274
    • /
    • 2021
  • Seismic fragility analysis of a structure is generally performed for the expected critical component of a structure. The seismic fragility analysis assumes that all the components behave independently in a structural system. A bridge system consists of many inter-connected components. Thus, for an accurate evaluation of the seismic fragility of a bridge, the seismic fragility analysis requires the composition of probabilities considering the correlation between structural components. This study presented a procedure to obtain the seismic fragility curve of a bridge system, considering the correlation between bridge components. Seismic fragility analysis was performed on a PSC bridge that is considered as the central infrastructure. The analysis results showed that the probability of the seismic fragility curve of the bridge system was higher than that of each bridge component.

Split-Capacitor Dual-Active-Bridge 컨버터 (Split-Capacitor Dual-Active-Bridge Converter)

  • 김기수;박시호;차헌녕;최병조
    • 전력전자학회논문지
    • /
    • 제23권5호
    • /
    • pp.352-358
    • /
    • 2018
  • A split-capacitor (SC) dual-active-bridge (DAB) converter is proposed in this study. The DC-link capacitors of input and output are split in the proposed converter. The primary and secondary windings of transformer are connected to the midpoints of the DC-links. Hence, the SC DAB converter can inherently prevent transformer from saturation. Although the switch current stress of the proposed converter is twice that of the conventional DAB converter, the switch voltage stress is reduced by half. Therefore, the proposed converter can reduce switching loss and achieve high efficiency in a high switching frequency. Given the SC structure, the proposed converter can readily be connected to neutral-point-clamped- or half-bridge-type converters. The topology of the proposed converter is presented and the operating principle is analyzed in detail. A 3-kW hardware prototype was built and tested to verify the performance of the proposed converter.

A study on ITZ percolation threshold in mortar with ellipsoidal aggregate particles

  • Pan, Zichao;Wang, Dalei;Ma, Rujin;Chen, Airong
    • Computers and Concrete
    • /
    • 제22권6호
    • /
    • pp.551-561
    • /
    • 2018
  • The percolation of interfacial transition zone (ITZ) in cementitious materials is of great importance to the transport properties and durability issues. This paper presents numerical simulation research on the ITZ percolation threshold of mortar specimens at meso-scale. To simulate the meso-scale model of mortar as realistically as possible, the aggregates are simplified as ellipsoids with arbitrary orientations. Major and minor aspect ratios are defined to represent the global shape characteristics of aggregates. Some algorithms such as the burning algorithm, Dijkstra's algorithm and Connected-Component Labeling (CCL) algorithm are adopted for identification of connected ITZ clusters and percolation detection. The effects of gradation and aspect ratios of aggregates on ITZ percolation threshold are quantitatively studied. The results show that (1) the ITZ percolation threshold is mainly affected by the specific surface area (SSA) of aggregates and shows a global decreasing tendency with an increasing SSA; (2) elongated ellipsoidal particles can effectively bridge isolated ITZ clusters and thus lower the ITZ percolation threshold; (3) as ITZ volume fraction increases, the bridging effect of elongated particles will be less significant, and has only a minor effect on ITZ percolation threshold; (4) it is the ITZ connectivity that is essentially responsible for ITZ percolation threshold, while other factors such as SSA and ITZ volume fraction are only the superficial reasons.

고층 스카이브리지의 변위 허용치 산정에 대한 연구 (Study on Evaluating Displacement Tolerance of Sky-bridge in Tall Buildings)

  • 김윤곤
    • 대한건축학회논문집:구조계
    • /
    • 제36권4호
    • /
    • pp.135-142
    • /
    • 2020
  • The new method for evaluating the displacement tolerance of sky-bridges with pin-roller type supports was proposed considering both return period of phase difference between connected buildings and geometrical characteristics of skybridge. Because displacement tolerance is relative value, which is most affected by the phase difference of the connected buildings, the dynamic response of these building with time history analysis should be evaluated. However, the initial phase could not be specified, so the result of displacement tolerance would be varied with respect to initial value. Thus, the tolerance can be reasonably evaluated SRSS calculation with design displacements based on statistical approach and of each building. In addition, the geometrical characteristics of sky-bridge should be considered because the transverse displacement of sky-bridge span causes the shear deformation of the bridge and longitudinal displacement tolerance cannot release the shear deformation. Therefore, the some pin-end support in sky-bridge should have longitudinal displacement tolerance to accommodate the shear deformation. By resolving this shear deformation, it is possible not only to accommodate transverse displacement, but also to avoid the complicated joint details such as both pot bearing and guided supports with shear key.