• Title/Summary/Keyword: congested area

Search Result 91, Processing Time 0.024 seconds

A Study on the Analysis of Simulation for Fire Safety Diagnosis in Building Congested Area (건축물 밀집지구의 화재위험성 평가를 위한 시뮬레이션 해석에 관한 연구)

  • Koo, In-Hyuk;Yoon, Ung-Gi;Kim, Bong-Chan;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.226-227
    • /
    • 2013
  • Korea rapidly arranged urbanization and overpopulation with high growth of economy and all kinds of decrepit facilities are scattered all over the downtown. If there is a strong wind in fire, fire is rapidly increased by various fire spread factors. And Korea cannot build prediction model of urban fire combustion phenomena because there is no studies that physically explains the suitable flame phenomena for its real state. In this study, based on the Japanese Urban fire simulation to target the building congested Area and suitability of fire risk assessment were reviewed.

  • PDF

A Study on the Analysis of Simulation for Fire Safety Diagnosis in Wooden Building Congested Area (목조건물 밀집 지역의 화재위험성 평가를 위한 시뮬레이션 해석에 관한 연구)

  • Koo, In-Hyuk;Kim, Bong-Chan;Seo, Dong-Goo;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.87-88
    • /
    • 2013
  • Korea rapidly arranged urbanization and overpopulation with high growth of economy and all kinds of decrepit facilities are scattered all over the downtown. If there is a strong wind in fire, fire is rapidly increased by various fire spread factors. And Korea cannot build prediction model of urban fire combustion phenomena because there is no studies that physically explains the suitable flame phenomena for its real state. In this study, based on the Japanese Urban fire simulation to target the wooden building congested Area and suitability of fire risk assessment were reviewed.

  • PDF

A Strategic Considerations for Optimization of Physical Distribution in Container Terminal (컨테이너 터미널의 물류체계의 최적화를 위한 전략적 고찰)

  • Yeo, G.T.;Lee, C.Y.
    • Journal of Korean Port Research
    • /
    • v.11 no.2
    • /
    • pp.145-156
    • /
    • 1997
  • The purpose in this study is development of model for the Container Terminals of Pusan Port, First of all, Quantitive and Qualititve factors are characterized which effects on Physical Distribution System in Container Terminals. The System Dynamics method is used to develope the model by using these factor. This model is able to present the timinig of investment in Container Terminals of Pusan Port. Six models are showed by change of parameters in System Dynamics, in this paper. In the model, Five feedback loop were found. Loop 1 : Number of Liners$\rightarrow$Number of Congested ships$\rightarrow$Port's Charges$\rightarrow$Export & Import Cargo Volumes$\rightarrow$Number of Liners$\rightarrow$The will to investment of government$\rightarrow$Length of berth→Number of Liners. Negative loop was acquired. Loop 2 : Port's Charge$\rightarrow$Economic of Port$\rightarrow$The will to Private management$\rightarrow$Efficiency for Port's Operation$\rightarrow$Port's Charges. Positive loop was acquired. Loop 3 : Number of Congested ships$\rightarrow$Planning for future development$\rightarrow$Information Service$\rightarrow$Support service for port's user$\rightarrow$Number of Congested ships. Negative loop was acquired. Loop 4 : Number of Congested ships$\rightarrow$Planning for future development$\rightarrow$Extent of stacking area$\rightarrow$Number of handling equipmint$\rightarrow$Number of Congested ships. Negative loop was acquired. Loop 5 : Export & Import Cargo Volumes$\rightarrow$Number of Liners$\rightarrow$Econmic of Port$\rightarrow$Support service for port's user$\rightarrow$Export & Import Cargo Volumes. Positive loop was acquired. System's level variables were selected as followings ; Number of Liners, Number of Congested ships, Export & Import Carge Volumes, Length of berth, and Port's Charges. As result of simmulation of model, fluctuation of respective year was found in level variables. This fluctuation can be used properly to present timing of investment.

  • PDF

An Application of a Sunshine Duration Model Based on GIS Data to Suitability of Measurement Site around the Seonleung Park

  • Kim, Eun-Ryoung;Kim, Jae-Jin
    • Korean Journal of Remote Sensing
    • /
    • v.31 no.4
    • /
    • pp.331-336
    • /
    • 2015
  • In this study, a numerical model developed for sunshine duration based on GIS data was used. This model considers blocking caused by topography and buildings and it is properly applicable to evaluation of sunshine duration environment in urban areas. The model reasonably well predicted the solar altitude and azimuth angels, compared to those provided by Korea Astronomy and Space Science Institute (KASI). The developed model was applied to evaluation of sunshine duration environment around the Seonleung Park located near a building-congested area in Seoul. The model well reproduced shadow caused by buildings and/or topography in the numerical domain at 09:00 on August 1, 2015. In addition, the model was applied to finding a suitable measurement sites for pyrheliometer around the Seonleung Park. The model was also usefully applied to finding a suitable site for pyrheliometer in an urban area.

Methicillin-Resistant Staphylococcus Aureus Following Leech Application at a Congested Flap after a Mastectomy

  • Hwang, Kun;Kim, Hyung Mook;Kim, Yeon Soo
    • Archives of Aesthetic Plastic Surgery
    • /
    • v.23 no.3
    • /
    • pp.143-145
    • /
    • 2017
  • Medical leech therapy is a treatment for the venous congestion of tissue flaps, grafts, and replants. We report a case of methicillin-resistant Staphylococcus aureus (MRSA) following leech application at a congested flap after mastectomy. A 45-year-old woman had an invasive ductal carcinoma. Modified radical mastectomy was performed. The chest wall defect was reconstructed with a local rotation flap. On postoperative day (POD) 1, congestion and color change were observed, and 10 medical leeches were applied to the congested area. On POD 4, another 10 medical leeches were applied. On POD 12, wound necrosis progressed and a pus-like discharge appeared. A wound swab culture revealed MRSA. Debridement was carried out on POD 15. From POD 16, vancomycin and piperacillin/tazobactam were injected for 18 days. The wound culture on POD 18 also revealed MRSA. A split-thickness skin graft was performed on POD 28. MRSA has not been clearly identified in the literature as a leech enteric bacterium. Although MRSA may have come from another source, the present case raises the possibility of MRSA infections following leech application at congested flaps. When medical leeches are applied at the congestion site of a flap, an aseptic cradle will be helpful. Vancomycin irrigation may be needed if infection occurs.

A Study on Characteristics of Traffic Flow in Congested Traffic at On-Ramp Influence Area (혼잡교통류 상태에서의 연결로 합류부 교통류 특성에 관한 기초 연구)

  • Kim, Sang-Gu;Kim, Young-Ho;Kim, Tae-Wan;Son, Young-Tae
    • Journal of Korean Society of Transportation
    • /
    • v.22 no.5
    • /
    • pp.99-109
    • /
    • 2004
  • Most traffic congestion on a freeway occurs in the merge area, where conflicts between mainline traffic and on-ramp traffic are frequently generated. So far, research on the merge area has mainly dealt with free flow traffic and research on the congested traffic at the merge area is rare. This study investigates the relationships between mainline traffic and on-ramp traffic at three different segments of the merge area. For this purpose, new indicators based on such traffic variables as flow, speed, and density are used. The results show that a negative relationship exists between mainline and on-ramp flow. It is also found that the speed and the density of the right two lanes in the mainline traffic are significantly affected by the on-ramp flow. Based on the correlation analysis of the indicators, it is confirmed that the ramp influence area is the right two lanes of the freeway mainline. The revealed relationships between mainline and on-ramp traffic may help to analyze the capacity of the downstream freeway segment of the merging area in congested traffic. The findings of this studyalso provide a basis to develop a model that estimates the merge traffic volume in congested traffic, which is neither theoretically nor empirically sound in most other traffic flow models developed so far.

Buffer Management for Improving Performance in WiMedia WLP-Based Mobile IP Networks of Ship Area (선박 내 WiMedia WLP 기반 Mobile IP 네트워크에서 성능향상을 위한 버퍼관리)

  • Lee, Seung Beom;Lee, Seong Ro
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.6
    • /
    • pp.1208-1216
    • /
    • 2015
  • In this paper, we use WiMedia WLP-based networks to meet the demand for IT services of a ship. If a mobile node moves to a congested base station of a new subnetwork, we will propose a scheme for improving performance of radio link of existing communicating mobile nodes. An old base station denotes packets stored during a handover. And, a proposed buffer management determines to discard the buffered packets in accordance with congestion degree at the congested new base station. Simulation results show that the proposed buffer management scheme improves link utilization in congested wireless links.

A Numerical Analysis on the Indoor Air Ventilation by Stack Effect and Outdoor Wind in a High-rise Residential Building (초고층 주거건물에서 굴뚝효과와 외풍영향에 인한 실내 환기 기류해석 및 평가에 관한 연구)

  • Kim, Chi-Wan;Lim, Tae-Kun;Ahn, Young-Chull
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.12
    • /
    • pp.828-835
    • /
    • 2011
  • The purpose of this study is to analyze and evaluate the 3 types of indoor ventilation methods such as natural, mechanical, and hybrid ventilation in high-rise building which is affected by stack effect and outdoor air pressure. For the evaluation of the ventilation capacity, CFD simulation was performed in a typical high-rise residential building. The results of the simulations are as follows: 1) Natural ventilation method is not enough to the regulation. 2) In case of mechanical ventilation, congested area is occurred but meets the regulation. 3) In case of hybrid ventilation with stack effect, all the areas of indoor meet the regulation and congested area is reduced. 4) In case of high-rise building, the differences of ventilation rate among houses in the building are not large because the mechanical ventilation is main factor.

Evaluation Methodology of Solar Rights Using Autodesk VIZ for Apartment Buildings (Autodesk VIZ를 이용한 공동주택의 일조권평가방법에 관한 연구)

  • Moon, Ki Hoon;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.6 no.3
    • /
    • pp.35-42
    • /
    • 2006
  • The apartment buildings now covers more than 50% of the total residential types in Korea and the urban residential area becomes increasingly congested with newly constructed high-rise apartment buildings. Judicial precedents require, for securing the solar rights in the residential area, that the consecutive sunshine duration should be at least two hours from 9:00 to 15:00 or the accumulative sunshine duration should be at least four hours from 8:00 to 16:00 as of the winter solstice. Disputes are increasing, however, on infringed solar rights and view rights for the neighboring structures as cases occur where the requirement cannot be satisfied in congested residential areas. The sunshine duration scan be assessed by measuring it on the site of the dispute, but it is impracticable to actually measure it for every case on the winter solstice, only one day out of the whole year. At a trial, therefore, 3D computer simulation is used to calculate the sunshine duration and determine the extent of infringement for submission of the evaluation to be used as the basis of the judgment. The simulation, however, may have an error in its result up to the program characteristics and the accuracy of the input data such as the structure shape and height, the distance between structures, and the ground level. This study, therefore, used a self-developed VIEW program with Autodesk VIZ 2006 to provide a simulation method for solar access evaluation, and verified its efficacy by comparing the results with the actual measurements.