• Title/Summary/Keyword: confocal

Search Result 843, Processing Time 0.032 seconds

Carbide Behavior in STD11 Tool Steel during Heat Treatment (STD11 공구강의 열처리 온도에 따른 탄화물 거동)

  • Hong, Ki-Jung;Song, Jin-Hwa;Chung, In-Sang
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.24 no.5
    • /
    • pp.262-270
    • /
    • 2011
  • Carbide precipitation and dissolution behavior at various temperatures during heat treatment has been studied in STD11 cold working die steel through confocal scanning laser microscopy; dilatometry; and X-ray diffraction analysis. The equilibrium phase diagram and phase fractions with temperature were calculated using a FactSage program. Confocal laser microscopic observation revealed that ${\alpha}$ to ${\gamma}$ transformation temperature is near $800^{\circ}C$; M7C3 carbides melt at $1245^{\circ}C$; and the melting temperature of STD11 is near $1370^{\circ}C$. XRD results indicated that the M23C6 carbides dissolve in the matrix if austenitized at over $1030^{\circ}C$; while the M7C3 carbides remain up to $1200^{\circ}C$ although their amount decreases. The calculated equilibrium phase diagram showed good agreement with experimental results on carbide dissolution and phase transformation temperatures.

Study on auto focusing system of laser beam by using fiber confocal method (파이버 공초점법을 이용한 레이저 빔 자동 초점 제어 장치에 관한 연구)

  • Moon, Seong-Wook;King, Sun-Hum;Kim, Jong-Bae;Bae, Han-Seong;Nam, Gi-Jung
    • Proceedings of the Korean Society of Laser Processing Conference
    • /
    • 2006.11a
    • /
    • pp.41-45
    • /
    • 2006
  • Auto focusing system to find optimized focal position of laser beam used for material process has been investigated by using fiber confocal method. Wavelength of laser diode (LD) and diameter of single-mode fiber we 780nm and $5.3{\mu}m$, respectively. Intensity distributions of beam reflected from the surface of mirror and silicon bare wafer have been observed in a gaussian form. Experimental results show that focal position obtained by LD is shifted from one observed from surface scribed by laser about $80{\mu}m$. It is due to the difference of wavelength and each divergence of between LD and laser used for material process. It is confirmed that auto focusing control system through position calibration has operated steadily.

  • PDF

Air Gap Measurement between Substrates Using Confocal Technique (공초점 방식을 이용한 기판 사이의 공기갭 측정)

  • Lee, Sun-Woo;Ahn, Kwang-Sin;Kwon, Nam-Ic
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.4
    • /
    • pp.207-210
    • /
    • 2009
  • A confocal technique was demonstrated for measuring the absolute value of an air gap between substrates. Since the two surfaces were in Rayleigh range of the laser focus for air gaps less than 200 nm, complete interference patterns were observed. And since interference patterns were obtained only from the area of focus, it was an advantage of this method that air gaps between multiple thin films could be measured. Stability is less than 1 nm except in the range where the interference pattern changes slowly.

Measurement of Sub-micrometer Features Based on The Topographic Contrast Using Reflection Confocal Microscopy

  • Lee SeungWoo;Kang DongKyun;Yoo HongKi;Kim TaeJoong;Gweon Dae-Gab;Lee Suk-Won;Kim Kwang-Soo
    • Journal of the Optical Society of Korea
    • /
    • v.9 no.1
    • /
    • pp.26-31
    • /
    • 2005
  • We describe the design and the implementation of video-rate reflection confocal scanning microscopy (CSM) using an acousto-optical deflector (AOD) for the fast horizontal scan and a galvanometer mirror (GM) for the slow vertical scan. Design parameters of the optical system are determined for optimal resolution and contrast. The OSLO simulations show that the performances of CSM are not changed with deflection angle and the wavefront errors of the system are less than 0.012λ. To evaluate the performances of designed CSM, we do a series of tests, measuring lateral and axial resolution, real time image acquisition. Due to a higher axial resolution compared with conventional microscopy, CSM can detect the surface of sub-micrometer features. We detect 138㎚ line shape pattern with a video-rate (30 frm/sec). And 10㎚ axial resolution is archived. The lateral resolution of the topographic images will be further enhanced by differential confocal microscopy (DCM) method and computational algorithms.

Fiber Optics for Multilayered Optical Memory

  • Kawata, Yoshimasa;Tsuji, Masatoshi;Inami, Wataru
    • Transactions of the Society of Information Storage Systems
    • /
    • v.7 no.2
    • /
    • pp.53-59
    • /
    • 2011
  • We have developed a compact and high-power mode-locked fiber laser for multilayered optical memory. Fiber lasers have the potential to be compact and stable light sources that can replace bulk solid-state lasers. To generate high-power pulses, we used stretched-pulse mode locking. The average power and pulse width of the output pulse from the fiber laser that we developed were 109 mW and 2.1 ps, respectively. The dispersion of the output pulse was compensated with an external single-mode fiber of 2.5 m length. The pulse was compressed from 2.1 ps to 93 fs by dispersion compensation. The fiber laser we have developed is possible to use as a light source of multilayered optical memory. We also present a fiber confocal microscope as an alignment-free readout system of multilayered optical memories. The fiber confocal microscope does not require fine pinhole position alignment because the fiber core is used as the point light source and the pinhole, and both of which are always located at the conjugated point. The configuration reduces the required accuracy of pinhole position alignment. With these techniques we can present an all-fiber recording and readout system for multilayered memories.

Baffle design and test for wide-field off-axis telescopes

  • Kim, Sanghyuk;Pak, Soojong;Chang, Seunghyuk;Kim, Geon Hee;Yang, Sun Choel;Lee, Sang Yong;Huh, Myung Sang;Im, Myungshin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.1
    • /
    • pp.72.2-72.2
    • /
    • 2013
  • An off-axis telescope has several advantages in optical performance comparing with a conventional on-axis telescope. However, in general, an off-axis telescope has a narrow field of view due to the linear astigmatism caused by the asymmetric structure. It was shown in the previous work that the linear astigmatism can be eliminated by properly configuring parameters in a confocal off-axis reflector system. Furthermore, the third order aberrations of a confocal off-axis telescope can be minimized by optimizing the shape of the mirrors. Despite many advantages, the confocal off-axis telescopes have been evaded because of difficulties of off-axis mirror fabrication, alignment process and unaccustomed off-axis baffle design. The baffle for the off-axis telescope should be designed considering that the effects of stray lights are different because of the asymmetry of off-axis system. In this poster, the design, manufacturing, and test for the baffle and housing of an off-axis telescope are presented.

  • PDF

Development of Confocal Imaging System for Wafer Inspection (개발 웨이퍼 검사위한 Confocal 이미징 시스템의 개발)

  • Ko, Kuk-Won;Nguyen, Cong Dai;Koh, Kyung-Cheol
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.05a
    • /
    • pp.108-112
    • /
    • 2010
  • Confocal Imaging System is an essential machine for a wide range of inspection wafer. For concurrent and fast acquiring the image data of four channels, the new image acquisition system used the protocol of camera-link standard with the full mode of configuration in interconnection with a frame grabber integrated in a computer, which is popularly used for many cameras, so the programming environment of image processing is optional such as Visual C++, Matlab. In addition, many conventional methods were coordinately used for contribution to build the high quality of images for precise processing analog signals of PhotoMutiplier Tubes(PMTs), accurate control of scanning device, sensitivity of PMTs, and laser source. The prototype of new image acquisition system, could meet the goal of development, it is used in LSCM for high content screening to investigation the processes of elements of living specimens at the same time by simultaneous grab image data on 4 PMTs channels.

  • PDF

3-D Imaging in a Chaotic Micromixer Using Confocal Laser Scanning Microscopy (CLSM) (공초점 현미경을 이용한 마이크로믹서 내부의 3차원 이미지화)

  • Kim, Hyun-Dong;Kim, Kyung-Chun
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2006.12a
    • /
    • pp.96-101
    • /
    • 2006
  • 3-D visualization using confocal laser scanning microscopy (CLSM) in a chaotic micromixer was performed as a reproduction experiment and the feasibility of 3-0 imaging technique in the microscale was confirmed. For diagonal micromixer (DM) and two types of staggered herringbone micromixers (SHM) designed by Whitesides et al., to verify the evolution of mixing, cross sectional images are reconstructed at the end of every cycle. In a DM, clockwise rotational flow motion generated by diagonal ridges placed on the floor of micromixer is observed and this motion makes the fluid commingle. On the contrary, there are two rotational flow structures in the SHM and the centers of rotation exchange their position each other every half cycle because of the V shape of ridges varying their orientation every half cycle. Local rotational flow and local extensional flow generated by the complicate ridge pattern make the flow be chaotic and accelerate the mixing of fluid. The dominant parameter that influences on the mixing characteristic of SHM is not the length of micromixer but the number of ridges under the same flow configurations.

  • PDF

Application of Autofluorescence for Confocal Microscopy to Aid in Archaeoparasitological Analyses

  • Morrow, Johnica Jo;Elowsky, Christian
    • Parasites, Hosts and Diseases
    • /
    • v.57 no.6
    • /
    • pp.581-585
    • /
    • 2019
  • Confocal laser scanning microscopy (CLSM) was used to examine archaeoparasitological specimens from coprolites associated with La Cueva de los Muertos Chiquitos (CMC) located near present-day Durango, Mexico. The eggs for 4 different types of parasites recovered from CMC coprolites were imaged using CLSM to assist with identification efforts. While some of the parasite eggs recovered from CMC coprolites were readily identified using standard light microscopy (LM), CLSM provided useful data for more challenging identifications by highlighting subtle morphological features and enhancing visualization of parasite egg anatomy. While other advanced microscopy techniques, such as scanning electron microscopy (SEM), may also detect cryptic identifying characters, CLSM is less destructive to the specimens. Utilizing CLSM allows for subsequent examinations, such as molecular analyses, that cannot be performed following SEM sample preparation and imaging. Furthermore, CLSM detects intrinsic autofluorescence molecules, making improved identification independent of resource and time-intensive protocols. These aspects of CLSM make it an excellent method for assisting in taxonomic identification and for acquiring more detailed images of archaeoparasitological specimens.