• 제목/요약/키워드: cone model

검색결과 369건 처리시간 0.027초

교대말뚝기초의 측방유동에 관한 원심모형실험 (Centrifuge Model Experiments for Lateral Soil Movements of Piled Bridge Abutments.)

  • 최동혁;정길수;박병수;유남재
    • 산업기술연구
    • /
    • 제25권B호
    • /
    • pp.63-71
    • /
    • 2005
  • This paper is an experimental result of investigating lateral soil movements at piled bridge abutments by using the centrifuge model facility. Three different centrifuge model experiments, changing the methods of ground improvement at bridge abutment on the soft clayey soil (no improvement, preconsolidation and plastic board drains (PBD), sand compaction pile (SCP) + PBD), were carried out to figure out which method is the most appropriate for resisting against the lateral soil movements. In the centrifuge modelling, construction process in field was reconstructed as close as possible. Displacements of abutment model, ground movement, vertical earth pressure, cone resistance after soil improvement and distribution of water content were monitored during and after centrifuge model tests. As results of centrifuge model experiments, preconsolidation method with PBD was found to be the most effective against the lateral soil movement by analyzing results about displacements of abutment model, ground movement and cone resistance. Increase of shear strength by preconsolidation method resulted in increasing the resistance against lateral soil movement effectively although SCP could mobilize the resistance against lateral soil movement. It was also found that installment with PBD beneath the backfill of bridge abutment induced effective drainage of excess pore water pressure during the consolidation by embanking at the back of the abutment and resulted in increasing the shear strength of clay soil foundation and eventually increasing the resistance of lateral soil movement against piles of bridge abutment.

  • PDF

바람과 진동을 고려한 항공기 탑재 AESA 레이다 성능 평가용 운동 모델링 및 시뮬레이션 (Modeling and Simulation of Aircraft Motion for Performance Assessment of Airborne AESA Radar Considering Wind and Vibration)

  • 이동욱;임재한;이해민;정영광;정재현;신종환;이성원;박준현;안재명
    • 한국항공우주학회지
    • /
    • 제48권11호
    • /
    • pp.903-910
    • /
    • 2020
  • 본 논문은 AESA 레이다를 탑재한 항공기가 비행 중 발생하는 바람과 진동에 의해 받는 영향을 평가하기 위한 시뮬레이터를 소개한다. AESA 레이다는 항공기의 노즈콘(nose cone)에 탑재하며, 비행 시 공기의 저항력에 의한 진동이 발생한다. 이 진동은 AESA 레이다의 거동에 영향을 주며, 수신한 신호의 위상 오차를 야기할 수 있다. 시뮬레이터는 레이다의 위치와 자세를 정확하게 모의하기 위해 강체 동역학, 평균 바람/난류, 그리고 모드/환경 진동에 대한 수학적 모델과 노즈콘에 대한 기하모델을 고려한다. 일련의 테스트 시나리오에 기반한 연구가 개발된 시뮬레이터의 효율성을 입증하기 위해 수행되었다.

Validity of Three-dimensional Facial Scan Taken with Facial Scanner and Digital Photo Wrapping on the Cone-beam Computed Tomography: Comparison of Soft Tissue Parameters

  • Aljawad, Hussein;Lee, Kyungmin Clara
    • Journal of Korean Dental Science
    • /
    • 제15권1호
    • /
    • pp.19-30
    • /
    • 2022
  • Purpose: The purpose of the study was to assess the validity of three-dimensional (3D) facial scan taken with facial scanner and digital photo wrapping on the cone-beam computed tomography (CBCT). Materials and Methods: Twenty-five patients had their CBCT scan, two-dimensional (2D) standardized frontal photographs and 3D facial scan obtained on the same day. The facial scans were taken with a facial scanner in an upright position. The 2D standardized frontal photographs were taken at a fixed distance from patients using a camera fixed to a cephalometric apparatus. The 2D integrated facial models were created using digital photo wrapping of frontal photographs on the corresponding CBCT images. The 3D integrated facial models were created using the integration process of 3D facial scans on the CBCT images. On the integrated facial models, sixteen soft tissue landmarks were identified, and the vertical, horizontal, oblique and angular distances between soft tissue landmarks were compared among the 2D facial models and 3D facial models, and CBCT images. Result: The results showed no significant differences of linear and angular measurements among CBCT images, 2D and 3D facial models except for Se-Sn vertical linear measurement which showed significant difference for the 3D facial models. The Bland-Altman plots showed that all measurements were within the limit of agreement. For 3D facial model, all Bland-Altman plots showed that systematic bias was less than 2.0 mm and 2.0° except for Se-Sn linear vertical measurement. For 2D facial model, the Bland-Altman plots of 6 out of 11 of the angular measurements showed systematic bias of more than 2.0°. Conclusion: The facial scan taken with facial scanner showed a clinically acceptable performance. The digital 2D photo wrapping has limitations in clinical use compared to 3D facial scans.

Intraoral scanning of the edentulous jaw without additional markers: An in vivo validation study on scanning precision and registration of an intraoral scan with a cone-beam computed tomography scan

  • Julie Tilly Deferm;Frank Baan;Johan Nijsink;Luc Verhamme;Thomas Maal;Gert Meijer
    • Imaging Science in Dentistry
    • /
    • 제53권1호
    • /
    • pp.21-26
    • /
    • 2023
  • Purpose: A fully digital approach to oral prosthodontic rehabilitation requires the possibility of combining (i.e., registering) digital documentation from different sources. This becomes more complex in an edentulous jaw, as fixed dental markers to perform reliable registration are lacking. This validation study aimed to evaluate the reproducibility of 1) intraoral scanning and 2) soft tissue-based registration of an intraoral scan with a cone-beam computed tomography (CBCT) scan for a fully edentulous upper jaw. Materials and Methods: Two observers independently performed intraoral scans of the upper jaw in 14 fully edentulous patients. The palatal vault of both surface models was aligned, and the inter-observer variability was assessed by calculating the mean inter-surface distance at the level of the alveolar crest. Additionally, a CBCT scan of all patients was obtained and a soft tissue surface model was generated using patient-specific gray values. This CBCT soft tissue model was registered with the intraoral scans of both observers, and the intraclass correlation coefficient(ICC) was calculated to evaluate the reproducibility of the registration method. Results: The mean inter-observer deviation when performing an intraoral scan of the fully edentulous upper jaw was 0.10±0.09 mm. The inter-observer agreement for the soft tissue-based registration method was excellent(ICC=0.94; 95% confidence interval, 0.81-0.98). Conclusion: Even when teeth are lacking, intraoral scanning of the jaw and soft tissue-based registration of an intraoral scan with a CBCT scan can be performed with a high degree of precision.

소형콘과 T-bar 관입기를 이용한 카올린 점토의 비배수전단강도 산정에 관한 연구 (Determination of Undrained Shear Strength using Miniature Cone and T-bar Penetrometers for Kaolin Clay)

  • ;추연욱
    • 대한토목학회논문집
    • /
    • 제38권3호
    • /
    • pp.429-438
    • /
    • 2018
  • 원추형콘과 T-bar 관입시험기는 점토의 비배수전단강도를 측정하기 위해 널리 사용된다. 축소모형시험의 경우 소형관입시험기가 사용되어야 하지만 경험상관계수에 대해 발표된 자료가 부족하다. 본 연구에서는 소형콘과 소형T-bar 관입시험기의 경험상관계수를 도출하기 위한 시험시스템을 구축하였고, 카올린점토에 대하여 실험을 수행하였다. 직경 350mm의 강재원형챔버를 사용하여 4개의 모형지반을 조성하였고, 각 모형지반은 다른 선행압밀응력에서 압밀하여 비배수전단강도를 조절하였다. 경계면 효과, 관입속도, 직경 및 형상의 영향을 확인하기 위하여 다른 직경을 가진 두 직경의 소형콘(10mm, 16mm)과 직경 10mm T-bar를 이용하여 시험을 수행하였다. 또한 관입시험 후의 시편을 채취하여 비압밀비배수삼축시험을 수행하여 비배수전단강도로 결정하였다. 최종적으로 비배수전단강도와 관입시 선단저항력의 상관관계를 통해 경험상관계수를 산정하였다.

육각 격자구조를 갖는 콘형 복합재 격자구조체의 구조안전성 평가 기법 연구 (Study on Evaluation Method of Structural Integrity for Cone-Type Composite Lattice Structures with Hexagonal Cell)

  • 임재문;강승구;신광복;이상우
    • Composites Research
    • /
    • 제31권4호
    • /
    • pp.156-160
    • /
    • 2018
  • 본 논문에서는 콘형 복합재 격자구조체의 구조안전성 평가 기법에 대해 연구를 수행하였다. 콘형 복합재격자구조체의 구조안전성 평가는 유한요소해석을 통해 수행되었다. 구조안전성 평가를 위한 유한요소모델은 솔리드 요소를 사용하여 생성하였다. 섬유 교차부와 비교차부의 물성 차이를 고려하기 위해 섬유 체적률을 고려한 기계적 물성을 적용하였다. 구조해석 기법의 검증을 위해 콘형 복합재 격자구조체의 압축 시험을 수행하였다. 시험과 해석의 비교 결과, 약 2%의 변위 오차가 발생하여 잘 일치하는 것을 확인하였다.

헵탄의 화원 직경 변화를 고려한 대형콘칼로리미터의 발열량 측정 결과 분석 (Analysis of Heat Release Rate with Various Diameter of Heptane Pool Fire Using Large Scale Cone Calorimeter)

  • 유우준;남동군;염문천;김성찬;유홍선
    • 한국화재소방학회논문지
    • /
    • 제28권5호
    • /
    • pp.1-7
    • /
    • 2014
  • 본 연구에서는 대형 콘 칼로리미터(large scale cone calorimeter, LSC)를 사용하여 헵탄 풀 화재(pool fire) 실험에서 화원의 직경 변화에 따른 발열량(HRR) 측정 결과를 정량적으로 분석하였다. 발열량에 중요한 영향을 미치는 연소율(burning rate)은 A. Hamins의 연구 자료에서 제시한 모델링 곡선과 비교하여 정확성을 검증하였으며, 산소 소모법에 의한 연소효율(combustion efficiency)은 이론발열량에 비해서 91% 정도로 J. Gore이 제시한 헵탄의 연소효율 92%와 유사한 것을 확인하였다. 엔탈피소모법에 의한 열손실은 전체 발열량의 54% 정도로 측정부에서 대류 발열량으로 측정되었으며, 본 연구 결과는 화재실험에서 발열량 측정값의 신뢰성 분석(reliability analysis)을 위한 기초 연구 자료로 활용하는데 유용한 정보가 될 것으로 사료된다.

Utilizing the GOA-RF hybrid model, predicting the CPT-based pile set-up parameters

  • Zhao, Zhilong;Chen, Simin;Zhang, Dengke;Peng, Bin;Li, Xuyang;Zheng, Qian
    • Geomechanics and Engineering
    • /
    • 제31권1호
    • /
    • pp.113-127
    • /
    • 2022
  • The undrained shear strength of soil is considered one of the engineering parameters of utmost significance in geotechnical design methods. In-situ experiments like cone penetration tests (CPT) have been used in the last several years to estimate the undrained shear strength depending on the characteristics of the soil. Nevertheless, the majority of these techniques rely on correlation presumptions, which may lead to uneven accuracy. This research's general aim is to extend a new united soft computing model, which is a combination of random forest (RF) with grasshopper optimization algorithm (GOA) to the pile set-up parameters' better approximation from CPT, based on two different types of data as inputs. Data type 1 contains pile parameters, and data type 2 consists of soil properties. The contribution of this article is that hybrid GOA - RF for the first time, was suggested to forecast the pile set-up parameter from CPT. In order to do this, CPT data and related bore log data were gathered from 70 various locations across Louisiana. With an R2 greater than 0.9098, which denotes the permissible relationship between measured and anticipated values, the results demonstrated that both models perform well in forecasting the set-up parameter. It is comprehensible that, in the training and testing step, the model with data type 2 has finer capability than the model using data type 1, with R2 and RMSE are 0.9272 and 0.0305 for the training step and 0.9182 and 0.0415 for the testing step. All in all, the models' results depict that the A parameter could be forecasted with adequate precision from the CPT data with the usage of hybrid GOA - RF models. However, the RF model with soil features as input parameters results in a finer commentary of pile set-up parameters.

스월 예혼합 버너의 연소 특성 및 NO 배출에 관한 수치적 연구 (Numerical Study of Combustion Characteristics and NO Emission in Swirl Premixed Burner)

  • 백광민;조천현;조주형;김한석;손채훈
    • 대한기계학회논문집B
    • /
    • 제37권10호
    • /
    • pp.911-918
    • /
    • 2013
  • Double cone 버너를 장착한 가스터빈용 EV (Environmental Vortex)버너의 연소 특성과 NO 배출 특성을 수치적으로 조사하였다. NO 배출 저감을 위해 연료와 공기의 혼합 특성을 예측하였다. 혼합도와 NO 배출과의 상관관계를 예측하기 위해 메탄 1단계 화학반응식과 2단계 반응식에 적용하여 연소 해석을 수행하였다. 1단계 반응식을 적용한 결과, 혼합도가 저하된 모델에서 NO 배출량이 약 2% 증가하였으며, 혼합도가 향상된 모델의 경우 cone 상부에서 과다한 고온의 화염 영역이 형성되어 NO가 약 169%나 증가하였다. 2단계 반응식의 경우 첫 번째 모델에서 약 3% NO 배출량이 증가하였으며, 두 번째 모델에서 cone 내부의 고온 영역이 형성되지 않고 NO가 약 5% 감소하였다. 이 결과는, 혼합 특성이 저감된 모델에서 NO가 약 63% 증가하였고, 혼합 특성이 향상된 모델에서 NO가 약 11% 감소한 실험결과와 잘 부합하였다. 정량적인 오차가 있음에도, NO 배출의 정성적 경향성이 유사하므로 2단계 반응식을 적용한 수치해석을 통해 설계 변경 방안을 제시하는 것은 타당할 것으로 판단된다.

안면골격 유형에 따른 하악 전치 치조골의 형태 차이: Cone-beam CT를 이용한 정량적 평가 (Morphological difference of symphysis according to various skeletal types using cone-beam computed tomography)

  • 권현진;전윤식;김민지
    • 구강회복응용과학지
    • /
    • 제30권3호
    • /
    • pp.215-222
    • /
    • 2014
  • 본 연구는 수평적, 수직적 안면 골격 유형에 따른 하악 전치부 치조골의 형태학적 차이를 알아보기 위하여 시행 하였다. 연구 재료 및 방법: 40명의 Cone-beam computed tomography (Cone-beam CT)를 선별하여, 4개 군으로 분류하였다. Cone-beam CT 자료를 이용하여 하악 전치부 치조골의 부피($mm^3$), 하악 4절치 치축 기준 시상단면의 단면적(총 단면적, 해면골 단면적: $mm^2$), 백악법랑경계(cemento-enamel junction: CEJ) 2 mm, 3 mm 아래 순, 설측 치조골 두께를 측정하였다. 통계분석은 GLM, Kruskal-Wallis test and Tukey HSD를 사용하였다. 결과: 측절치의 백악법랑경계 2 mm, 3 mm 하방 설측 치조골 두께가, Class I low angle군이 나머지 3군 보다 두꺼웠다 (P < 0.05). 하악 전치 치조골의 부피, 전체 치조골 및 해면골의 단면에서의 통계적으로 유의한 차이는 없었다. 결론: Class I low angle군은 Class II high angle군에 비해 하악 전치 치조골의 설측 부위가 더 두껍다.