• Title/Summary/Keyword: cone beam computed tomography (CBCT)

Search Result 556, Processing Time 0.026 seconds

Comparison of cone-beam computed tomography cephalometric measurements using a midsagittal projection and conventional two-dimensional cephalometric measurements

  • Jung, Pil-Kyo;Lee, Gung-Chol;Moon, Cheol-Hyun
    • The korean journal of orthodontics
    • /
    • v.45 no.6
    • /
    • pp.282-288
    • /
    • 2015
  • Objective: This study investigated whether it is possible to use a two-dimensional (2D) standard in three-dimensional (3D) analysis, by comparing the angles and lengths measured from a midsagittal projection in 3D cone-beam computed tomography (CBCT) with those measured by 2D lateral cephalometric radiography (LCR). Methods: Fifty patients who underwent both LCR and CBCT were selected as subjects. CBCT was reoriented in 3 different methods and the measuring-points were projected onto the midsagittal plane. Twelve angle values and 8 length values were measured on both LCR and CBCT and compared. Results: Repeated measures analysis of the variance revealed statistically significant differences in 7 angular and 5 linear measurements among LCR and 3 types of CBCT (p < 0.05). Of these 12 measurements, multiple comparisons showed that 6 measurements (ANB, AB to FH, IMPA, FMA, Co-Gn, Go-Me) were not significantly different in pairwise comparisons. LCR was significantly different from 3 types of CBCT in 3 angular (SN to FH, interincisal angle, FMIA) and 2 linear (S-Go, Co-ANS) measurements. The CBCT method was similar for all measurements, except for 1 linear measurement, i.e., S-N. However, the disparity between the mean values for all parameters was within the range of clinical measurement error. Conclusions: 3D-CBCT analysis, using midsagittal projection, is a useful method in which the 2D-LCR normative values can be used. Although the measurements changed with reorientation, these changes were not clinically significant.

Assessment of metal artifacts in three-dimensional dental surface models derived by cone-beam computed tomography

  • Nabha, Wael;Hong, Young-Min;Cho, Jin-Hyoung;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.44 no.5
    • /
    • pp.229-235
    • /
    • 2014
  • Objective: The aim of this study was to assess artifacts induced by metallic restorations in three-dimensional (3D) dental surface models derived by cone-beam computed tomography (CBCT). Methods: Fifteen specimens, each with four extracted human premolars and molars embedded in a plaster block, were scanned by CBCT before and after the cavitated second premolars were restored with dental amalgam. Five consecutive surface models of each specimen were created according to increasing restoration size: no restoration (control) and small occlusal, large occlusal, disto-occlusal, and mesio-occluso-distal restorations. After registering each restored model with the control model, maximum linear discrepancy, area, and intensity of the artifacts were measured and compared. Results: Artifacts developed mostly on the buccal and lingual surfaces. They occurred not only on the second premolar but also on the first premolar and first molar. The parametric values increased significantly with increasing restoration size. Conclusions: Metallic restorations induce considerable artifacts in 3D dental surface models. Artifact reduction should be taken into consideration for a proper diagnosis and treatment planning when using 3D surface model derived by CBCT in dentofacial deformity patients.

Early-diagnosed silent sinus syndrome and cone-beam computed tomography in a pediatric patient: a case report

  • Leidens, Natali;Franco, Ademir;Santos, Marco C.J.;Makeeva, Irina M.;Fernandes, Angela
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.46 no.2
    • /
    • pp.155-159
    • /
    • 2020
  • Chronic maxillary atelectasis (CMA) is a progressive alteration in the volume of the maxillary sinuses that may result in facial asymmetry. CMA in asymptomatic patients is known as silent sinus syndrome (SSS) and is a rare entity, especially in pediatric patients. This study reports a case of SSS in a pediatric patient who received an early diagnosis through cone-beam computed tomography (CBCT). An asymptomatic 12-year-old female patient in orthodontic treatment presented with opacification of the left maxillary sinus on a panoramic radiograph. Clinically, the patient had discrete hypoglobus and enophthalmos. CBCT and nasal video-endoscopy revealed ostiomeatal obstruction with bone deformity, leading to diagnosis of SSS. Endonasal endoscopic maxillary sinusotomy was performed. Two years later, the patient remained asymptomatic, and a second CBCT exam confirmed a stable condition. This case highlights the role of optimal radiographic interpretation for early diagnosis of maxillofacial alterations in pediatric patients.

Assessment of maxillary third molars with panoramic radiography and cone-beam computed tomography

  • Jung, Yun-Hoa;Cho, Bong-Hae
    • Imaging Science in Dentistry
    • /
    • v.45 no.4
    • /
    • pp.233-240
    • /
    • 2015
  • Purpose: This study investigated maxillary third molars and their relation to the maxillary sinus using panoramic radiography and cone-beam computed tomography (CBCT) Materials and Methods: A total of 395 maxillary third molars in 234 patients were examined using panoramic radiographs and CBCT images. We examined the eruption level of the maxillary third molars, the available retromolar space, the angulation, the relationship to the second molars, the number of roots, and the relationship between the roots and the sinus. Results: Females had a higher frequency of maxillary third molars with occlusal planes apical to the cervical line of the second molar (Level C) than males. All third molars with insufficient retromolar space were Level C. The most common angulation was vertical, followed by buccoangular. Almost all of the Level C molars were in contact with the roots of the second molar. Erupted teeth most commonly had three roots, and completely impacted teeth most commonly had one root. The superimposition of one third of the root and the sinus floor was most commonly associated with the sinus floor being located on the buccal side of the root. Conclusion: Eruption levels were differently distributed according to gender. A statistically significant association was found between the eruption level and the available retromolar space. When panoramic radiographs showed a superimposition of the roots and the sinus floor, expansion of the sinus to the buccal side of the root was generally observed in CBCT images.

Endodontic management of mandibular first premolar with C-shaped canals by using cone-beam computed tomography and dental operating microscope (CBCT와 치과용 현미경을 이용한 C형 근관을 가지는 하악 제1소구치의 근관치료)

  • Chang, Hoon-Sang;Kim, Min-Jeong;Lee, Seok-Ryun;Hong, Sung-Ok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.4
    • /
    • pp.324-328
    • /
    • 2014
  • Aberrant anatomy of mandibular premolars is very rare in Korean, but aberration can contribute the endodontic failure as it makes difficult to remove the irritants during cleaning and shaping procedure. This case report describes the successful root canal treatment of a rare mandibular first premolar with C-shaped root canal as using a cone-beam computed tomography to understand the internal shape of root canal system and a dental operating microscope to improve the magnification and illumination.

Endodontic management of a maxillary lateral incisor with dens invaginatus and external root irregularity using cone-beam computed tomography

  • Lim, Young-Jun;Nam, Sook-Hyun;Jung, Sung-Ho;Shin, Dong-Ryul;Shin, Su-Jung;Min, Kyung-San
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.1
    • /
    • pp.50-53
    • /
    • 2012
  • Cone-beam computed tomography (CBCT) is a useful diagnostic tool for identification of both internal and external root configurations. This case report describes the endodontic management of a lateral incisor with both dens invaginatus and external root irregularity by using CBCT. Nonsurgical endodontic retreatment was performed on the lateral incisor with dens invaginatus. A perforation through the dens invaginatus and external concavity was repaired using mineral trioxide aggregate. After 18 mon of follow-up, there were no clinical symptoms. Recall radiographs appeared normal and showed healing of the periapical pathosis. The understanding of both internal root canal configuration and external root irregularity using CBCT can ensure predictable and successful results.

Effect of Voxel Size on the Accuracy of Landmark Identification in Cone-Beam Computed Tomography Images

  • Lee, Kyung-Min;Davami, Kamran;Hwang, Hyeon-Shik;Kang, Byung-Cheol
    • Journal of Korean Dental Science
    • /
    • v.12 no.1
    • /
    • pp.20-28
    • /
    • 2019
  • Purpose: This study was performed to evaluate the effect of voxel size on the accuracy of landmark identification in cone-beam computed tomography (CBCT) images. Materials and Methods: CBCT images were obtained from 15 dry human skulls with two different voxel sizes; 0.39 mm and 0.10 mm. Three midline landmarks and eight bilateral landmarks were identified by 5 examiners and were recorded as three-dimensional coordinates. In order to compare the accuracy of landmark identification between large and small voxel size images, the difference between best estimate (average value of 5 examiners' measurements) and each examiner's value were calculated and compared between the two images. Result: Landmark identification errors showed a high variability according to the landmarks in case of large voxel size images. The small voxel size images showed small errors in all landmarks. The landmark identification errors were smaller for all landmarks in the small voxel size images than in the large voxel size images. Conclusion: The results of the present study indicate that landmark identification errors could be reduced by using smaller voxel size scan in CBCT images.

Soft Tissue Measurement Method Using Radiopaque Material on Cone-beam Computed Tomography: An Ex Vivo Validation Study

  • Lee, Hae-Seok;Yun, Jeong-Ho;Lee, Dong-Won
    • Implantology
    • /
    • v.22 no.4
    • /
    • pp.210-218
    • /
    • 2018
  • Purpose: The purpose of this study was to investigate the validity and reproducibility of a method based on cone-beam computed tomography (CBCT) technology for the visualization and measurement of gingival soft-tissue dimensions. Material and Methods: A total of 66 selected points in soft-tissue of the ex vivo head of an adult pig were investigated in this study. For the measurement of radiographic thickness (RT), wet soft-tissue surfaces were lightly covered with barium sulfate powder using a powder spray. CBCT was taken and DICOM files were assessed for soft-tissue thickness measurement at reference points. A periodontal probe and a rubber stop were used for the measurement of trans-gingival probing thickness (TPT). After flap elevation, actual thickness of soft-tissue (actual thickness, AT) was measured. Correlation analysis and intraclass correlation coefficients analysis (ICC) were performed for AT, TPT, and RT. Results: All variables were distributed normally. Strong significant correlations of AT with RT and TPT values were found. The two ICC values between TPT vs. AT and RT vs. AT differed significantly. Conclusion: Our results indicated that correlation of RT was stronger than that of TPT with AT. We concluded that soft tissue measurement with CBCT could be a reliable method, compared to the trans-gingival probing measurement method.

A cone-beam computed tomographic study of C-shaped root and root canal in maxillary molars (콘빔CT (Cone beam computed tomography, CBCT)를 이용한 상악 대구치 에서의 C-형 치근 및 근관에 관한 연구)

  • Kim, Jin-Woo;Ji, Hyo-Jin;Cho, Kyung-Mo;Kim, Sung-Min;Park, Se-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.2
    • /
    • pp.104-111
    • /
    • 2015
  • Purpose: The aim of this retrospective study was to investigate the prevalence rate and types of C-shaped roots and C-shaped canal in maxillary molars by analyzing cone-beam computed tomography (CBCT) in a Korean population. Materials and Methods: Total of 357 CBCT images of maxillary molars (186 first molar, 171 second molar) were evaluated by two Endodontic specialists. Results: Eight types of C-shaped roots and 5 types of C-shaped canals were founded, the prevalence rate of C-shaped roots and canals were 21.0% and 5.3% respectively. Conclusion: These anatomical variations were more frequent in second molars than the first molars. Clinicians should have anatomical knowledge about various types of C-shaped root and root canal for successful root canal therapy.

Dose estimation of cone-beam computed tomography in children using personal computer-based Monte Carlo software (PCXMC 소프트웨어를 이용한 소아에서의 CBCT 환자선량 평가)

  • Kim, Eun-Kyung
    • The Journal of the Korean dental association
    • /
    • v.58 no.7
    • /
    • pp.388-397
    • /
    • 2020
  • Objective: The purpose of the study was to calculate the effective and absorbed organ doses of cone-beam computed tomography (CBCT) in pediatric patient using personal computer-based Monte Carlo (PCXMC) software and to compare them with those measured using thermoluminescent dosimeters (TLDs) and anthropomorphic phantom. Materials and Methods: Alphard VEGA CBCT scanner was used for this study. A large field of view (FOV) (20.0 cm × 17.9 cm) was selected because it is a commonly used FOV for orthodontic analyses in pediatric patients. Ionization chamber of dose-area product (DAP) meter was located at the tube side of CBCT scanner. With the clinical exposure settings for a 10-year-old patient, DAP value was measured at the scout and main projection of CBCT. Effective and absorbed organ doses of CBCT at scout and main projection were calculated using PCXMC and PCXMCRotation software respectively. Effective dose and absorbed organ doses were compared with those obtained by TLDs and a 10-year-old child anthropomorphic phantom at the same exposure settings. Results: The effective dose of CBCT calculated by PCXMC software was 292.6 μSv, and that measured using TLD and anthropomorphic phantom was 292.5 μSv. The absorbed doses at the organs largely contributing to effective dose showed the small differences between two methods within the range from -18% to 20%. Conclusion: PCXMC software might be used as an alternative to the TLD measurement method for the effective and absorbed organ dose estimation in CBCT of large FOV in pediatric patients.

  • PDF