• Title/Summary/Keyword: cone axis

Search Result 94, Processing Time 0.023 seconds

Comparison of landmark positions between Cone-Beam Computed Tomogram (CBCT) and Adjusted 2D lateral cephalogram (Cone-Beam Computed Tomogram (CBCT)과 Adjusted 2D lateral cephalogram의 계측점 차이에 관한 비교 연구)

  • Son, Soo-Jung;Chun, Youn-Sic;Kim, Minji
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.3
    • /
    • pp.222-232
    • /
    • 2014
  • Purpose: This study aims to investigate if 2D analysis method is applicable to analysis of CBCT by comparing measuring points of CBCT with those of Adjusted 2D Lateral Cephalogram (Adj-Ceph) with magnification adjusted to 100% and finding out at which landmarks the difference in position appear. Materials and methods: CBCT data and Adj-Ceph (100% magnification) data from 50 adult patients have been extracted as research objects, and the horizontal (Y axis) and vertical (Z axis) coordinates of landmarks were compared. Landmarks have been categorized into 4 groups by the position and whether they are bilaterally overlapped. Paired t-test was used to compare differences between Adj-Ceph and CBCT. Results: Significant difference was found at 11 landmarks including Group B (S, Ar, Ba, PNS), Group C (Po, Or, Hinge axis, Go) and Group D (U1RP, U6CP, L6CP) in the horizontal (Y) axis while all the landmarks in vertical (Z) axis showed significant difference (P<.05). As a result of landmark difference analysis, a meaningful difference with more than 1 mm at 13 landmarks were indentifed in the horizontal axis. In the vertical axis, significant difference over 1 mm was detected from every landmark except Sella. Conclusion: Using the conventional lateral cephalometric measurements on CBCT is insufficient. A new 3D analysis or a modified 2D analysis adjusted on 19 landmarks of the vertical axis and 13 of the horizontal axis are needed when implementing CBCT diagnosis.

Comparison to Cone Models for Halo Coronal Mass Ejections

  • Na, Hyeon-Ock;Moon, Yong-Jae
    • Bulletin of the Korean Space Science Society
    • /
    • 2011.04a
    • /
    • pp.28.3-28.3
    • /
    • 2011
  • Halo coronal mass ejections (HCMEs) are mainly responsible for the most severe geomagnetic storms. To minimize the projection effect of the HCMEs observed by coronagraphs, several cone models have been suggested. These models allow us to determine the geometrical and kinematic parameters of HCMEs : radial speed, source location, angular width, and the angle between the central axis of the cone and the plane of the sky. In this study, we compare these parameters form two representative cone models (the ice-cream cone model and the asymmetric cone model) using well-observed HCMEs from 2001 to 2002. And we obtain the root mean square error (rms error) between observed projection speeds and calculated projection speeds for both cone models. It is found that the average rms speed error (89 km/s) of the asymmetric cone model is a little smaller than that (107 km/s) of the ice-cream cone models, implying that the radial speeds from both models are reasonably estimated. We also find that the radial speeds obtained from two models are similar to each other with the correlation coefficient of about 0.8.

  • PDF

Numerical optimization of flow uniformity inside an under body- oval substrate to improve emissions of IC engines

  • Om Ariara Guhan, C.P.;Arthanareeswaran, G.;Varadarajan, K.N.;Krishnan, S.
    • Journal of Computational Design and Engineering
    • /
    • v.3 no.3
    • /
    • pp.198-214
    • /
    • 2016
  • Oval substrates are widely used in automobiles to reduce the exhaust emissions in Diesel oxidation Catalyst of CI engine. Because of constraints in space and packaging Oval substrate is preferred rather than round substrate. Obtaining the flow uniformity is very challenging in oval substrate comparing with round substrate. In this present work attempts are made to optimize the inlet cone design to achieve the optimal flow uniformity with the help of CATIA V5 which is 3D design tool and CFX which is 3D CFD tool. Initially length of inlet cone and mass flow rate of exhaust stream are analysed to understand the effects of flow uniformity and pressure drop. Then short straight cones and angled cones are designed. Angled cones have been designed by two methodologies. First methodology is rotating flow inlet plane along the substrate in shorter or longer axis. Second method is shifting the flow inlet plane along the longer axis. Large improvement in flow uniformity is observed when the flow inlet plane is shifted along the direction of longer axis by 10, 20 and 30 mm away from geometrical centre. When the inlet plane is rotated again based on 30 mm shifted geometry, significant improvement at rotation angle of $20^{\circ}$ is observed. The flow uniformity is optimum when second shift is performed based on second rotation. This present work shows that for an oval substrate flow, uniformity index can be optimized when inlet cone is angled by rotation of flow inlet plane along axis of substrate.

Evaluation of mesiodistal tooth axis using a CBCT-generated panoramic view (CBCT-재구성 파노라마영상의 근원심 치축에 관한 연구)

  • Song, In-Tae;Cho, Jin-Hyoung;Chae, Jong-Moon;Chang, Na-Young
    • The korean journal of orthodontics
    • /
    • v.41 no.4
    • /
    • pp.255-267
    • /
    • 2011
  • Objective: The purpose of this study was to confirm the reliability of a cone beam computed tomography (CBCT)-generated panoramic view based on a CBCT 3D image and to find the most helpful 2D panoramic image compared with CBCT 3D image when examining the mesiodistal tooth axis. Methods: A test model was constructed according to cephalometric norms. The test model was repeatedly repositioned for CBCT and panoramic radiographic imaging. Panoramic radiographs were acquired at each of the following 3 occlusal plane positions: $-5^{\circ}$, $0^{\circ}$, and $+5^{\circ}$. Measurements of mesiodistal tooth axis in CBCT 3D image, CBCT-generated panoramic view, and panoramic radiographs were compared. Results: Compared with the CBCT-generated panoramic view, CBCT 3D image showed significant difference in the mesiodistal tooth axis in the premolars and no significant difference in the mesiodistal tooth axis in the incisors and canines. Mesiodistal tooth axis on the CBCT-generated panoramic view was significantly different from that on panoramic radiographs. Conclusions: CBCT-generated panoramic view can be a useful tool for evaluating mesiodistal tooth axis.

A study of incisive canal using a cone beam computed tomography (cone beam형 전산화 단층촬영장치를 이용한 절치관의 연구)

  • Kim Gyu-Tae;Hwang Eui-Hwan;Lee Sang-Rae
    • Imaging Science in Dentistry
    • /
    • v.34 no.1
    • /
    • pp.7-12
    • /
    • 2004
  • Purpose: To investigate the anatomical structure of the incisive canal radiographically by a cone beam computed tomography. Materials and Methods: 38 persons (male 26, female 12) were chosen to take images of maxillary anterior region in dental CT mode using a cone beam computed tomography. The tube voltage were 65, 67, and 70kVp, the tube current was 7 mA, and the exposure time was 13.3 seconds. The FH plane of each person was parallel to the floor. The images were analysed on the CRT display. Results: The mean length of incisive canal was 15.87 mm±2.92. The mean diameter at the side of palate and nasal fossa were 3.49 mm±0.76 and 3.89 mm± 1.06, respectively. In the cross-sectional shape of incisive canal, 50% were round, 34.2% were ovoid, and 15.8% were lobulated. 87% of incisive canal at the side of nasal fossa have one canal, 10.4% have two canals, and 2.6% have three canals, but these canals were merged into one canal in the middle portion of palate. The mean angles of the long axis of incisive canal and central incisor to the FH plane were 110.3°±6.96 and 117.45°±7.41, respectively. The angles of the long axis of incisive canal and central incisor to the FH plane were least correlated (r= 0.258). Conclusion : This experiment suggests that a cone beam computed radiography will be helpful in surgery or implantation on the maxillary incisive area.

  • PDF

Implementing 3-D Image Reconstruction Algorithms for Compton (컴프턴 카메라를 위한 3 차원 영상 재구성 알고리즘의 구현)

  • Lee, Mi-No;Lee, Soo-Jin
    • The Journal of Engineering Research
    • /
    • v.8 no.1
    • /
    • pp.51-57
    • /
    • 2006
  • We propose efficient methods for implementing 3-D reconstruction algorithms for Compton camera. Since reconstructing Compton scattered data involves the surface integral over the cone associated with the measurement bin, it is crucial to develop a computationally efficient surface integration method. In this work we assume that a cone is made up of a series of ellipses (or circles) stacked up one o top of the other. In order to reduce computational burden for tracing ellipses formed by the intersection of a cone and an image plane, we construct a series of imaginary planes perpendicular to the cone axis so that each plane contains a circle, not an ellipse. In this case the surface integral can be performed by adding uniform samples along each circle. The experimental results demonstrate that our method using imaginary planes significantly improves computational efficiency while keeping reconstruction accuracy.

  • PDF

Interference-Free Tool Approach Directions in Multi-Axis NC Machining of Sculptured Surfaces (자유 곡면의 다축 NC 가공시 간섭 없는 공구 접근 자세 영역)

  • J.G. Kang
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.7
    • /
    • pp.108-115
    • /
    • 1997
  • In this paper, an algorithm of computing interference-free tool approach directions(visibility cone) with consideration of tool volume at an arbitrary point of a sculptured surface is developed. The surface is first approximated into a polyhedron with smaller subpatches and the tool approach directions are evenly sampled so as to test accessibility. Then the visibility cone is computed by testing if each approach direction is interfered by other surface subpatches. The results are represented as the binary spherical map which transform geometric information on sphere into aogebraic one. The developed algorithm is implemented and tested by several sculptured surfaces, convincing it can be easily used as a tool for not only interference- free tool approach directions but also determining process planning of multi-axis NC machining of sculp- tured surfaces

  • PDF

Analysis of the root position and angulation of maxillary premolars in alveolar bone using cone-beam computed tomography

  • Yun-Hoa, Jung;Bong-Hae, Cho;Jae-Joon, Hwang
    • Imaging Science in Dentistry
    • /
    • v.52 no.4
    • /
    • pp.365-373
    • /
    • 2022
  • Purpose: This study investigated whether the relationship between the maxillary sinus and the root of the maxillary premolar is correlated with the root position and whether there is a difference in the long axis angle of premolars and the buccal bone thickness according to the sinus-root relationship and root position. Materials and Methods: Cone-beam computed tomographic images of 587 maxillary first premolars and 580 second premolars from 303 patients were retrospectively reviewed. The maxillary sinus floor-root relationship was classified into 4 types, and the root position in the alveolar bone was evaluated as buccal, middle, or palatal. The long axis angle of the maxillary premolars in the alveolar bone and the buccal bone thickness were measured. The correlation between these parameters was analyzed. Results: The maxillary sinus floor-root relationship showed a statistically significant correlation with the root position in the alveolar bone. Most maxillary first premolars were buccally located, and more than half of the second premolars had their roots in the middle. The long axis angle of the premolars was significantly larger in buccal-positioned teeth than in middle-positioned teeth, and the buccal bone was thinner. Conclusion: When the root of the maxillary premolar was separated from the sinus floor, the premolar was often located on the buccal side. Most of the maxillary first premolars had a thinner buccal bone and larger inclination than the second premolars. It is recommended to evaluate the root position, sagittal angle and buccal bone thickness using CBCT for implant treatment planning.

ERUPTION PATTERN OF THE MANDIBULAR FIRST MOLAR USING THE CONE BEAM CT (Cone Beam CT를 이용한 하악 제 1대구치 맹출 양상에 관한 연구)

  • Shin, Jeong-Keun;Kim, Jae-Gon;Baik, Byeong-Ju;Yang, Yeon-Mi;Jeong, Jin-Woo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.3
    • /
    • pp.325-336
    • /
    • 2009
  • The purpose of this study was to investigate the eruption pattern of the mandibular first molar in sagittal, frontal and horizontal views using the cone beam CT scanning. CT images were obtained from healthy 83 children (42 boys, 41 girls) between 3 to 10 years of age with a normal dentition according to Nolla stage. 1. In the frontal and horizontal view, the intermolar width decreased continuously with stage and slightly increased at the last stage. 2. In the sagittal and frontal view, eruption distances from occlusal plane were observed the largest change between stage 5 and 7. 3. In the horizontal and sagittal view, mandibular first molar from distal surface of primary second molar moved distally between stage 4 and 6. 4. In the sagittal view, angle from occlusal plane to mesio-distal axis increased between stage 4 and 8. 5. In the frontal view, angle from occlusal plane to bucco-lingual axis increased continuously during all stage. 6. In the horizontal view, angle from midsagittal plane to long axis increased between stage 5 and 8.

  • PDF

Design of Cone-Shaped Magnetic Bearing Spindle System for High Speed Internal Grinding Machine (내면연삭기 고속 주축용 원추형 자기베어링시스템 설계)

  • Park, Jong-Gwon;No, Seung-Guk;Gyeong, Jin-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.2
    • /
    • pp.213-219
    • /
    • 2002
  • A cone-shaped active magnetic healing spindle system for high speed internal grinding with built-in motor that has 7.5kW power and maximum rotational speed of 50,000 rpm is designed and built. Using cone-shaped AMB(Active Magnetic Bearing) system, the axial rotor dick and magnets of conventional 5-axis actuating design can be eliminated. so this concept of design provides a simple magnetic bearing system. In this paper, the cone-shaped electromagnets are designed by magnetic circuit theory, and a de-coupled direct feedback PID controller is applied to control the coupled magnetic bearings. The designed crone-shaped AMB spindle system is built and constructed with a digital control system, which has TMS320C6702 DSP, 16 bit AD/DA, switching power amplifier and gap sensors. As the AMB system provides high damping ratio eliminating overshoot and resonance speed, this spindle runs up to 40,000 rpm stably with about 5${\mu}{\textrm}{m}$ of runout.