Effects of Magnetic Resonance Imaging on the Human Body : Analysis of differences according to Dental Implant Material (자기공명영상이 인체에 미치는 영향 : 치아임플란트 재료에 따른 차이 분석)

  • Choe, Dea-yeon;Kim, Dong-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.4
    • /
    • pp.481-489
    • /
    • 2018
  • In MRI examination, when irradiating the human body with RF Pulse to acquire images, the portion of the irradiated RF Pulse energy is absorded into the human body, and this will affect the temperature of the human body. If a metal is inserted into the human body even if the same RF Pulse energy is applied, the SAR value increases and the body temperature changes due to the increase in the electromagnetic wave conductivity of the metal. So we measure and compared with the change in the SAR and temperature in the implant material of the dental implant in Brain MRI examinations. Experiments were performed on a human head model using a 64MHz and 128 MHz RF Pulse frequency generated by a 3.0 Tesla MRI apparatus. And then changed material of dental implants to Titanium and $Al_2O_3$. Using the XFDTD program, the changes in SAR and body temperature around the head were examined. When with Titanium the SAR value and temperature of Brain increased, but with $Al_2O_3$ showed lower SAR and temperature as compared with Titanium. The dental implants were low in SAR and temperature of the head in $Al_2O_3$, which are electrical insulators with low electrical conductivity, compared to Titanium, which is an electrical conductor. It is necessary to study the biologic effect of patient with brain MRI when titanium dental implant material is inserted in the future. Because the maximum value of SAR is much higher than the limit when dental implant material is Titanium. In addition, it is necessary to use an implant of $Al_2O_3$ material to reduce the SAR value and temperature of the Brain in Brain MRI examination.

Calcium Removal from Effluent of Electronics Wastewater Using Hydrodynamic Cavitation Technology (수리동력학적 캐비테이션을 이용한 전자폐수 처리수에 함유된 칼슘저감에 관한 연구)

  • Park, Jin-Young;Kim, Sun-Jip;Lee, Yong-Woo;Lee, Jae-Jin;Hwang, Kyu-Won;Lee, Won-Kwon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.6
    • /
    • pp.715-721
    • /
    • 2007
  • Residual calcium concentration is high, in general, at the effluent of the fluoride removal process in the electronics industry manufacturing semiconductor and LCD. To increase the stability of the membrane process incorporated for reuse of wastewater, the residual calcium is required to be pre-removed. Hyperkinetic Vortex Crystallization(HVC) process was installed in the electronics industry manufecturing semi conductor as a pilot scale for accelerating calcification of calcium ion. Compared to the conventional soda ash method, the 31% higher calcium removal efficiency was achieved when HVC was applied at the same sodium carbonate dosage. In order to maintain the economic calcium removal target of 70% preset by manufacturer, the dosing concentration of the soda ash was 530 mg/L based on influent flowrate. The seed concentration in the reactor was one of the critical factors and should be maintained in the range of $800\sim1,200mg$ SS/L to maximize the calcium removal efficiency. The calcite production rate was 0.30 g SS/g $Na_2CO_3$ in the average. The economic HVC passing time of the mixture was in the range of $2\sim5$ times. Relatively, stable calcium concentration was maintained in the range of $30\sim72$ mg/L(average 49 mg/L) although the calcium concentration in the feed was severely fluctuated with $74\sim359$ mg/L(average 173 mg/L). The HVC process was characterized as environment-friendly technology reducing chemical dosage and chemical sludge production and minimizing maintenance cost.

Metal Oxides Decorated Carbon Nanotube Freestanding Electrodes for High Performance of Lithium-sulfur Batteries (고성능 리튬-황 전지를 위한 금속산화물을 첨가한 탄소나노튜브 프리스탠딩 전극)

  • Yun Jung Shin;Hyeon Seo Jeong;Eun Mi Kim;Tae Yun Kim;Sang Mun Jeong
    • Korean Chemical Engineering Research
    • /
    • v.61 no.3
    • /
    • pp.426-438
    • /
    • 2023
  • Lithium-sulfur batteries, recently attracting attention as next-generation batteries, have high energy density but are limited in application due to sulfur's insulating properties, shuttle phenomenon, and volume expansion. This study used an economical and simple vacuum filtration method to prepare a freestanding electrode without a binder and collector. Carbon nanotubes (CNTs) are used to improve the electrical conductivity of sulfur, where CNT also acts as both collector and conductor. In addition, metal oxides (MOx, M=Ni, Mg), which are easy to adsorb lithium polysulfide, are added to the CNT/S electrode to suppress the shuttle reaction in lithium-sulfur batteries, which is a result of suppressing the loss of active sulfur material due to the excellent adsorption of lithium polysulfide by metal oxides. The MOx@CNT/S electrode exhibited higher capacity characteristics and cycle stability than the CNT/S electrode without metal oxides. Among the MOx@CNT/S electrodes, the NiO@CNT/S electrode displayed a high discharge capacity of 780 mAh g-1 at 1 C and an extreme capacity decrease to 134 mAh g-1 after 200 cycles. Although the MgO@CNT/S electrode exhibited a low discharge rate of 544 mAh g-1 in the initial cycle, it showed good cycle stability with 90% of capacity retention up to 200 cycles. Further, to achieve high capacity and cycle stability, the Ni0.7Mg0.3O@CNT/S electrode, mixed with Ni:Mg in the ratio of 0.7:0.3, manifested an initial discharge rate of 755 mAh g-1 (1 C) and a capacity retention rate of more than 90% after 200 cycles. Therefore, applying binary metal oxides to CNT/S provides a freestanding electrode for developing economical and high-performance Li-S batteries, effectively improving lithium polysulfide's high capacity characteristics and dissolution.

A Study on Effects of Application of Nursing Process by Nursing Profess notes.(School of nursing) (간호기록지를 통해서 본 간호과정 적용효과에 관한 연구(간호전문대학을 중심으로))

  • 최상순;조희숙;백승남
    • Journal of Korean Academy of Nursing
    • /
    • v.11 no.2
    • /
    • pp.55-68
    • /
    • 1981
  • The prime object of the study is to evaluate how much all the students of the Nursing Schools throughout the nation are in comprehension toward the application of nursing process to clinical experience as means of systematic solution of nursing problems. An effort has been made to find out the actual state whether they are in practice of clinical experience in accordance with application of nursing process, over the period of four weeks managing from December 1st to 28th, 1980 and centering on 36 nursing schools, and meanwhile and evaluation, employing the assessment tool used by Bertuccietal, has been made on the nursing process notes recorded by 200 senions out of 21 nursing schools where application of nursing process to clinical experience being in practice. The assessment tool is composed of 5 different criteria in view of patient nursing and authors made an attempt to find out the result of clinical experience on application students in accordance with 5 different scoring criteria and further evaluating all the findings thereof. The findings were disposed of accordance with practice duration and criteria of the specific sudents subject to this finding as to verify the scoring difference in significance and of which the results are as follows: 1) as of now, in 21 (58.2%) out of 36 nursing Schools nursing process in being appliced in clinical experience. 2) Schools that started the application of nursing process to clinical experience amount to - for more than 4 yrs -6 (28.6%) - for 2 to 3 yrs-11s(52.4%) - for 1 yr -4 (19.0%) 3) As for the response upon application of nursing process. To clinical etperience, the largest voice (61.9%) heard was that it is rather difficult beyond the lecturing thereof, to practically apply it outs patients and the second voice (19.1%) turned out to be that it is hard to put in practice owing to uninformed nurses of the process serving in the clinical field. 4) The response. Of the processors assigned to instruction as to the most difficult problem in criteria of nursing process, the largest voice (38.2%) centered on the problem assessment while the second voice (17.7%) on the indirect nursing activity and the objective data respectively and considered to be the easiest was the indirect nursing activity (11.7%). 5) In order for a satisfactory. application of nursing process to clinical experience hence-forth, it has been pointed out that sufficient number of nurses should be supplemented in clinical field (44.1%) and at the same time supplementory education (35.3%) centered around professors be necessary. 6) Of the criteria that record result of nursing process, a significant difference in comprehension of subjective and objective data has been revealed according to the degree of the practice duration of application to clinical experience. For instance, while although poor it may seen, only 74.9% in subjective data and 71.1% in objective data represent the student group in practice for more than 4 years and only 56.3% in subjective data and 66.8% in objective data represent the student group in practice for 2 to 3 years but they still surpass in comprehension over the student group in practice for 1 year attaning only 19.6% in subjective data and 16.8% in objective data (P < 0.005). 7) As for problem assessment, the student group who started application of nursing process for 4 years stand for 37,7% the group for 2 to 3 years started for 25.3% and the group for 1 year started for 5.4%, revealing no significant difference according to duration (P < 0.5) and as poor as to indicate only 22.8% on an overage is in comprehension. 8) On direct and indirect nursing activity, the student group of for more than 4 years in appling nursing process (representing 49.5% in direct nursing activity, 21.4% in indirect nursing activity). Know more about it than the student group of for 2 to 3 years (representing 36.3% in direct nursing activity, 20.8% in indirect nursing activity) but revealed no significant difference. (P < 0.5) 9) The student group applying nursing process for more than 4 years subjective data (74.9%) comprehend were more than objective data (71.1%) but shown no significant difference (P < 0.5). 10) However, the student group applying nursing process for 2 to 3 years comprehend objective data (66.8%) well ever subjective data (55.5%) indicating that 40.9% in average is in comprehension, thereby revealing a significant difference (P < 0.005). 11) On the other hand, the student group applying nursing process to clinical experience for 1 year had revealed themselves as poorly as to comprehend only 11.7% are an average of it, revealing no significant difference (P < 0.5). In consequence of the fore going, I the conductor of the present study, hereby suggest the following points: 1) Application of nursing process to clinical experience be practiced in all the Nursing Schools all over the nation at the earliest possible date in order that scientific nursing be prevailed (as of now only 58.0%), 2) In teaching nursing process, it is desirable to teach specific method of applying to practical clinical situations. 3) In order to meet the end of satisfactory application of nursing process to clinical experience, sufgecient nursing man power be sysplemented in clinical field and at the save time supplementary education by professors is necessary. 4) Sinces the students whose application duration of nursing process to clinical experience is longer comprehend more about it, it is reguired that the schools not yet in practice of the application be promptlyurged to follow. 5) Of the criteria recording nursing process, since it is comparatively hard to comprehend“assessment”and“Direct and indirect nursing activity”, a concentrated instruction is desirable. 6) The students whose duration of application of nursing process to clinical experience falls short of 1 years be put in a concentrated guidance program on individual criterion.

  • PDF

The study of thermal change by chemoport in radiofrequency hyperthermia (고주파 온열치료시 케모포트의 열적 변화 연구)

  • Lee, seung hoon;Lee, sun young;Gim, yang soo;Kwak, Keun tak;Yang, myung sik;Cha, seok yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.97-106
    • /
    • 2015
  • Purpose : This study evaluate the thermal changes caused by use of the chemoport for drug administration and blood sampling during radiofrequency hyperthermia. Materials and Methods : 20cm size of the electrode radio frequency hyperthermia (EHY-2000, Oncotherm KFT, Hungary) was used. The materials of the chemoport in our hospital from currently being used therapy are plastics, metal-containing epoxy and titanium that were made of the diameter 20 cm, height 20 cm insertion of the self-made cylindrical Agar phantom to measure the temperature. Thermoscope(TM-100, Oncotherm Kft, Hungary) and Sim4Life (Ver2.0, Zurich, Switzerland) was compared to the actual measured temperature. Each of the electrode measurement position is the central axis and the central axis side 1.5 cm, 0 cm(surface), 0.5 cm, 1.8 cm, 2.8 cm in depth was respectively measured. The measured temperature is $24.5{\sim}25.5^{\circ}C$, humidity is 30% ~ 32%. In five-minute intervals to measure the output power of 100W, 60 min. Results : In the electrode central axis 2.8 cm depth, the maximum temperature of the case with the unused of the chemoport, plastic, epoxy and titanium were respectively $39.51^{\circ}C$, $39.11^{\circ}C$, $38.81^{\circ}C$, $40.64^{\circ}C$, simulated experimental data were $42.20^{\circ}C$, $41.50^{\circ}C$, $40.70^{\circ}C$, $42.50^{\circ}C$. And in the central axis electrode side 1.5 cm depth 2.8 cm, mesured data were $39.37^{\circ}C$, $39.32^{\circ}C$, $39.20^{\circ}C$, $39.46^{\circ}C$, the simulated experimental data were $42.00^{\circ}C$, $41.80^{\circ}C$, $41.20^{\circ}C$, $42.30^{\circ}C$. Conclusion : The thermal variations were caused by radiofrequency electromagnetic field surrounding the chemoport showed lower than in the case of unused in non-conductive plastic material and epoxy material, the titanum chemoport that made of conductor materials showed a slight differences. This is due to the metal contents in the chemoport and the geometry of the chemoport. And because it uses a low radio frequency bandwidth of the used equipment. That is, although use of the chemoport in this study do not significantly affect the surrounding tissue. That is, because the thermal change is insignificant, it is suggested that the hazard of the chemoport used in this study doesn't need to be considered.

  • PDF