• Title/Summary/Keyword: conductivity cell

Search Result 789, Processing Time 0.031 seconds

The effects of conductivity and CNT cathode on electricity generation in air-cathode microbial fuel cell (공기양극 미생물연료전지 시스템에서 전력발생특성에 미치는 전기전도도와 CNT 양극의 영향)

  • Yoo, Kyu-Seon;Park, Hyun-Soo;Song, Young-Chae;Woo, Jung-Hui;Lee, Chae-Young;Chung, Jae-Woo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.3
    • /
    • pp.355-360
    • /
    • 2012
  • The characteristics of power generation were investigated by changing the electrical conductivity from 10 to 40mS/cm using air-cathode microbial fuel cell, which had graphite fiber fabric(GFF) anode. There were three kinds of cathode used: one was carbon cloth cathode coated with Pt, another was carbon nanotube(CNT) cathode with non-precious catalyst of Fe-Cu-Mn, and the other was carbon nanotube(CNT) cathode without any catalyst. When it was operated in batch mode, power density of 1369.5mW/$m^2$ was achieved at conductivity of 20mS/cm. Power density from MFC with CNT cathode coated with multi-catalyst of Fe-Cu-Mn was shown about 985.55mW/$m^2$, which was 75.1% compared the power density of carbon cloth coated with Pt. This meant that CNT cathode coated with multi-catalyst of Fe-Cu-Mn could be an alternative of carbon cloth cathode.

Effect of the Molecular Weight of Poly(vinyl alcohol) Blended with Sulfonated Polysulfone Membranes for Fuel Cell Applications

  • Chang, Sung-Hyuk;Chung, Sung-Il;Rhim, Ji-Won
    • Korean Membrane Journal
    • /
    • v.5 no.1
    • /
    • pp.18-24
    • /
    • 2003
  • In order to improve the mechanical properties of the sulfonated polysulfone (SPSf) membranes previously synthesized in our laboratory, poly(vinyl alcohol) (PVA) was blended which is well known as the excellent physical and chemical properties. The resulting membranes blended with several molecular weight of PVA varying from 13,000 to 124,000 have been characterized to investigate the effect of PVA molecular weight in terms of ion conductivities, methanol permeabilities, water contents and ion exchange capacities for both heat treated and untreated membranes at 150$^{\circ}C$. The proton conductivity is decreased as the molecular weight of PVA increases. The plain SPSf-6.0 showed the proton conductivity of 0.078 S/cm whereas the blended membrane with M.W. 31,000 PVA indicated 0.04 S/cm. For methanol permeabilities, when PVA is added to SPAf-6.0, methanol crossover is increased because of the gain of the hydrophilicity from 3.4 to 6.5${\times}$10$\^$-6/ $\textrm{cm}^2$/s. For the annealed blended membranes (with M.W. 31,000 PVA), both the methanol corssover and proton conductivity showed very consistent values, about 2.3${\times}$10$\^$-6/ $\textrm{cm}^2$/s and 0.036 S/cm, respectively.

Responses of Tobacco Photomixotrophic Cultured Cells to Various Herbicides (다양한 제초제에 대한 담배 Photomixotrophic 배양세포의 반응)

  • 권혜경;권석윤;이행순;윤의수;김진석;조광연;곽상수
    • Korean Journal of Plant Tissue Culture
    • /
    • v.26 no.3
    • /
    • pp.183-187
    • /
    • 1999
  • To establish an efficient screening system for new herbicides using plant cultured cells, responses of tobacco photomixotrophic cultured (PH) cells to various herbicides with different modes of action were surveyed by measuring the cell growth and ion conductivity in medium. The cells were cultured in Murashige and Skoog (MS) medium containing 0.7mg/L 2,4-D, 0.3mg/L kinetin and 30 g/L sucrose at $25^{\circ}C$ in the light (100 rpm). Chemicals were treated to suspension cultures of tobacco PH cells at the time of subculture. The cell growth and ion conductivity in the medium were investigated on 12 days after chemical treatment. The ion conductivity assay gave well correlated results to the cell growth inhibition data. The responses of tobacco PM cells were dependent on the modes of action of chemicals tested. Atrazine, an inhibitor of photosynthetic electron transport (PET), strongly inhibited both the cell membrane and cell growth ($IC_{50}$/, about 1 $\mu$M). Butachlor (an inhibitor of cell division), glufosinate (an inhibitor of amino acid biosynthesis), and fluridone (an inhibitor of carotenoid biosynthesis) showed a dose-dependent inhibition. However, Quinclorac, a herbicide with an auxin activity, did not affect the cell growth and ion leakage. These results suggested that tobacco PM cells is suitable materials for the simple screening of new herbicides such as PET, amino acid biosynthesis, ceil division inhibitors by measuring the cell growth and ion conductivity.

  • PDF

Reduction of Methanol Crossover in a Direct Methanol Fuel Cell by Using the Pt-Coated Electrolyte Membrane

  • Jung, Eun-Mi;Rhee, Young-Woo;Peck, Dong-Hyun;Lee, Byoung-Rok;Kim, Sang-Kyung;Jung, Doo-Hwan
    • Journal of the Korean Electrochemical Society
    • /
    • v.11 no.1
    • /
    • pp.1-5
    • /
    • 2008
  • A Pt-layer was deposited on the anode side of a Nafion membrane via a sputtering method in order to reduce methanol crossover in a direct methanol fuel cell (DMFC). The methanol permeation and the proton conductivity through the modified membranes were investigated. The performances of the direct methanol fuel cell were also tested using single cells with a Nafion membrane and the modified membranes. The Pt-layers on the membrane blocked both methanol crossover and proton transport through the membranes. Methanol permeability and proton conductivity decreased with an increase of the platinum layer thickness. At methanol concentration of 2 M, the DMFC employing the modified membrane with a platinum layer of 66 nm-thickness showed similar performance to that of a DMFC with a bare Nafion membrane in spite of the lower proton conductivity of the former. The maximum power density of the cell using the modified membrane with a platinum layer of 66 nm-thickness increased slightly while that of the cell with the bare membrane decreased abruptly when a methanol solution of 6M was supplied.

Characterization of Polymer Blends of Poly(ether sulfone)/Sulfonated Poly(ether ether ketone) for DMFC (직접메탄올 연료전지용 Poly(ether sulfone)/Sulfonated Poly(ether ether ketone) 블렌드 막의 특성 연구)

  • Cheon, Hun Sang;Lee, Choong Gon;Hong, Seong Uk
    • Applied Chemistry for Engineering
    • /
    • v.16 no.1
    • /
    • pp.144-149
    • /
    • 2005
  • Sulfonated poly(ether ether ketone) (SPEEK) was blended with poly(ether sulfone) (PES) at various compositions. To investigate the possibility of using the blend membranes as polymer electrolyte membranes for direct methanol fuel cell, the blend membranes were characterized in terms of methanol permeability, proton conductivity, ion exchange capacity, and water content. Both proton conductivity and methanol permeability of SPEEK were relatively high. As the amount of PES increased, methanol permeability decreased more rapidly compared to proton conductivity. The experimental results indicated that the blend membrane with 40 wt% PES was the best choice in terms of the ratio of proton conductivity to methanol permeability.

Effect of Carbon Fiber Filament and Graphite Fiber on the Mechanical Properties and Electrical Conductivity of Elastic Carbon Composite Bipolar Plate for PEMFC (PEMFC용 탄성 탄소 복합재료 분리판의 기계적 강도 및 전기전도도에 미치는 탄소섬유 필라멘트와 흑연 섬유의 영향)

  • Lee, Jaeyoung;Lee, Wookum;Rim, Hyungryul;Joung, Gyubum;Lee, Hongki
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.25 no.2
    • /
    • pp.131-138
    • /
    • 2014
  • Highly conductive bipolar plate for polymer electrolyte membrane fuel cell (PEMFC) was prepared using phenol novolac-type epoxy/graphite powder (GP)/carbon fiber filament (CFF) composite, and a rubber-modified epoxy resin was introduced in order to give elasticity to the bipolar plate graphite fiber (GF) was incorporated in order to improve electrical conductivity. To find out the cure condition of the mixture of novolac-type and rubber-modified epoxies, differential scanning calorimetry (DSC) was carried out and their data were introduced to Kissinger equation. And tensile and flexural tests were carried out using universal testing machine (UTM) and the surface morphology of the fractured specimen and the interfacial bonding between epoxy matrix and CFF or GF were observed by a scanning electron microscopy (SEM).

Reliability Evaluation of Miniaturized Measurement Cell of Effective Thermal Conductivity for Hydrogen Storage Materials (소형 수소저장물질 유효열전도도 측정장치의 신뢰성 평가)

  • LEE, YOUNG HYO;IM, YEON HO
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.26 no.5
    • /
    • pp.431-437
    • /
    • 2015
  • Recently, a miniaturized measurement cell of effective thermal conductivity was developed to evaulate the heat transfer characteristics of hydrogen stroage material in the initial step of its development. In this work, the realiablity issues which can occur from this miniaturization of measurement cell were studied in detail by both experiments and numerical simulation of heat transfer. $LaNi_5$ as a reference was used for the reliability evaluation of the miniaturized measurement cell. Numerical simulations of heat transfer for this measurement system were verified through comparison with the experimental data. Under these reliablity studies, we discuss how to overcome the inherent drawbacks of this miniaturized system in order to achieve the high reliability.

TCO Workfunction Engineering with Oxygen Reactive Sputtering Method for Silicon Heterojunction Sola Cell Application

  • Bong, Seong-Jae;Kim, Seon-Bo;An, Si-Hyeon;Park, Hyeong-Sik;Lee, Jun-Sin
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.492-492
    • /
    • 2014
  • On account of the good conductivity and optical properties, TCO is generally used in silicon heterojunction solar cell since the emitter material, hydrogenated amorphous silicon (a-Si:H), of the solar cell has low conductivity compare to the emitter of crystalline silicon solar cell. However, the work function mismatch between TCO layer and emitter leads to band-offset and interfere the injection of photo-generated carriers. In this study, work function engineering of TCO by oxygen reactive sputtering method was carried out to identify the trend of band-offset change. The open circuit voltage and short circuit current are noticeably changed by work function that effected from variation of oxygen ratio.

  • PDF

Effects of Calcination Temperature on Characteristics of Electrospun TiO2 Catalyst Supports for PEMFCs (열처리 온도가 전기방사방법을 이용하여 제조한 PEMFC용 TiO2 담체의 물리적 특성에 미치는 영향)

  • Kwon, Chorong;Yoo, Sungjong;Jang, Jonghyun;Kim, Hyoungjuhn;Kim, Jihyun;Cho, Eunae
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.24 no.3
    • /
    • pp.223-229
    • /
    • 2013
  • Polymer Electrolyte Membrane Fuel Cell (PEMFC) is a power generation system to convert chemical energy of fuels and oxidants to electricity directly by electrochemical reactions. As a catalyst support for PEMFCs, carbon black has been generally used due to its large surface area and high electrical conductivity. However, under certain circumstances (start up/shut down, fuel starvation, ice formation etc.), carbon supports are subjected to serve corrosion in the presence of water. Therefore, it would be desirable to switch carbon supports to corrosion-resistive support materials such as metal oxide. $TiO_2$ has been attractive as a support with its stability in fuel cell operation atmosphere, low cost, commercial availability, and the ease to control size and structure. However, low electrical conductivity of $TiO_2$ still inhibits its application to catalyst support for PEMFCs. In this paper, to explore feasibility of $TiO_2$ as a catalyst support for PEMFCs, $TiO_2$ nanofibers were synthesized by electrospinning and calcinated at 600, 700, 800 and $900^{\circ}C$. Effects of calcination temperature on crystal structure and electrical conductivity of electrospun $TiO_2$ nanofibers were examined. Electrical conductivity of $TiO_2$ nanofibers increased significantly with increasing calcination temperature from $600^{\circ}C$ to $700^{\circ}C$ and then increased gradually with increasing the calcination temperature from $700^{\circ}C$ to $900^{\circ}C$. It was revealed that the remarkable increase in electrical conductivity could be attributed to phase transition of $TiO_2$ nanofibers from anatase to rutile at the temperature range from $600^{\circ}C$ to $700^{\circ}C$.

Studies on the Diagnosis of Subclinical Mastitis in Cows by the Measurement of the Electrical Conductivity: 1. Comparison of Various Methods of Handling Conductivity Data with the Use of California Mastitis Test and Direct Somatic Cell Count (전기전도도(電氣傳導度) 측정(測定)에 의한 유우(乳牛) 준임상형(準臨床型) 유방염(乳房炎)의 진단(診斷)에 관한 연구(硏究) 1. 전기전도도법(電氣傳導度法)과 간접검진법(間接檢診法)(CMT 및 총체세포수(總體細胞數))과의 비교(比較))

  • Kang, Byong-kyu
    • Korean Journal of Veterinary Research
    • /
    • v.24 no.1
    • /
    • pp.91-98
    • /
    • 1984
  • A total of 466 foremilk from dairy farms in Chonnam district was examined for the subclinical mastitis over a period of one year, using a method of the electrical conductivities(EC); absolute conductivity(AC) and differential conductivity(DC) and quarter difference value(QD), in relation to the California mastitis test(CMT) and the direct somatic cell count(DSCC). The compatibility and efficiency rating between the EC values and the other screening tests was conducted. Obtained results are summarized as follows. 1. A linear relationship was found between the EC values and the CMT scores and direct somatic cell counts and it was found that electrical conductivity measurements were comparable with other screening tests for diagnosing animals with mastitis. 2. Compatibilities between the EC and CMT were 70.4% in AC, 74.6% in DC and 70.7% in QD, and that of the EC and DSCC were 53.0% in AC, 63.1% in DC and 53.2% in QD. On the other hand, relative efficiency ratings of Postle's equation between EC and CMT were 37.3% in AC, 26.5% in DC and 13.6% in QD, and that of the EC and DSCC were 33.1% in AC, 20.2% in DC and 11.9% in QD. 3. In the foremilk samples collected from damaged quarters determined by EC, the false positive rate wart higher than the false negative rate, and consequently tests of EC produced lower compatibility or efficiency rating scores. These tendencies suggested that any factors other than the mastitic condition influencing the EC values might be existed.

  • PDF