• Title/Summary/Keyword: conduction model

Search Result 525, Processing Time 0.031 seconds

Sliding Mode Control for Current Distribution Control in Paralleled Positive Output Elementary Super Lift Luo Converters

  • Kumar, Kuppan Ramash;Jeevananthan, Seenithangam
    • Journal of Power Electronics
    • /
    • v.11 no.5
    • /
    • pp.639-654
    • /
    • 2011
  • This paper presents a Current Distribution Control design for Paralleled Positive Output Elementary Super Lift Luo Converters (PPOESLLCs) operated in Continuous Conduction Mode using a Sliding Mode Controller (SMC). Manipulating the higher current requirement of the load through the paralleling of POESLLCs, results in a current inequality. This is mainly due to dissimilarities in the power semiconductor switches and circuit components used in POESLLCs, which may lead to converter failures. In order to balance the proper load current sharing and the load voltage regulation of PPOESLLCs, a SMC is developed. The SMC is designed for the inherently variable-structured of POESLLCs by using the state-space average based model. The static and dynamic performance of the developed controller with PPOESLLCs is validated for its robustness to perform over a wide range of operating conditions through both a laboratory prototype and MatLab/Simulink models, which are compared with a Proportional-Integral (PI) controller. Theoretical analysis, simulation and experimental results are presented to demonstrate the feasibility of the developed SMC along with the complete design procedure.

The change of deflagration to detonation transition by wall cooling effect in ethylene-air mixture (에틸렌-공기 혼합물에서 벽면 온도 감소에 의한 연소폭발천이 현상 변화)

  • Gwak, Min-Cheol;Kim, ki-Hong;Yo, Jai-Ick
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.04a
    • /
    • pp.457-462
    • /
    • 2011
  • This paper presents a numerical investigation of deflagration to detonation transition (DDT) induced by shock wave and flame interaction in ethylene-air mixtures. Also shows the change of DDT triggering time by wall cooling effect. A model is consisted of the compressible reactive Navier-Stokes equations. And the effect of viscosity, thermal conduction, molecular diffusion, chemical reaction and wall effect are included. Using this model, the generation of hot spot by repeated shock and flame interaction, occurrence of detonation, and wall cooling effect of detonation confining boundaries are studied.

  • PDF

Numerical Simulation of the Oscillating Flow Effect in the Channel of Polymer Electrolyte Membrane Fuel Cell (왕복 유동을 통한 확산증대 효과가 연료전지 성능에 미치는 영향에 대한 수치해석)

  • Kim, Jongmin;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.20 no.4
    • /
    • pp.7-13
    • /
    • 2018
  • This study investigates the enhancement of the oxygen diffusion rate in the cathode channel of a proton exchange membrane fuel cell (PEMFC) by pure oscillating flow, which is the same as the mechanism of human breathe. Three-dimensional numerical simulation, which has the full model of the fuel cell including electrochemical reaction, ion and electronic conduction, mass transfer and thermal variation and so on, is performed to show the phenomena in the channel at the case of a steady state. This model could analysis the oscillating flow as a moving mesh calculation coupled with electrochemical reaction on the catalyst layer, however, it needs a lot of calculation time for each case. The two dimensional numerical simulation has carried on for the study of oscillating flow effect in the cathode channel of PEMFC in order to reduce the calculation time. This study shows the diffusion rate of the oxygen increased and the emission rate of the water vapor increased in the channel by oscillating flow without any forced flow.

Development and verification of PWR core transient coupling calculation software

  • Li, Zhigang;An, Ping;Zhao, Wenbo;Liu, Wei;He, Tao;Lu, Wei;Li, Qing
    • Nuclear Engineering and Technology
    • /
    • v.53 no.11
    • /
    • pp.3653-3664
    • /
    • 2021
  • In PWR three-dimensional transient coupling calculation software CORCA-K, the nodal Green's function method and diagonal implicit Runge Kutta method are used to solve the spatiotemporal neutron dynamic diffusion equation, and the single-phase closed channel model and one-dimensional cylindrical heat conduction transient model are used to calculate the coolant temperature and fuel temperature. The LMW, NEACRP and PWR MOX/UO2 benchmarks and FangJiaShan (FJS) nuclear power plant (NPP) transient control rod move cases are used to verify the CORCA-K. The effects of burnup, fuel effective temperature and ejection rate on the control rod ejection process of PWR are analyzed. The conclusions are as follows: (1) core relative power and fuel Doppler temperature are in good agreement with the results of benchmark and ADPRES, and the deviation between with the reference results is within 3.0% in LMW and NEACRP benchmarks; 2) the variation trend of FJS NPP core transient parameters is consistent with the results of SMART and ADPRES. And the core relative power is in better agreement with the SMART when weighting coefficient is 0.7. Compared with SMART, the maximum deviation is -5.08% in the rod ejection condition and while -5.09% in the control rod complex movement condition.

A Study on System Identification of Small Thermal Vacuum Chamber Based on Test Data (시험 데이터 기반 소형 열진공챔버 시스템 식별에 관한 연구)

  • Park, Sung-Wook;Kim, Seungkeun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.49 no.5
    • /
    • pp.407-415
    • /
    • 2021
  • The performance of satellite parts must be verified under the space orbit environment before the launch. This paper develops a model formula considering the thermal environment such as conduction, radiation, heat loss and internal heating between satellite parts and a small thermal vacuum chamber for thermal vacuum tests. System identification is carried out using test data from 20 recent thermal vacuum tests conducted by the Korea Aerospace Research Institute. It is verified that the model formula and the identification results are valid, except when the heating of the functional test of the test specimen is not constant.

An investigation into the thermo-elasto-hydrodynamic effect of notched mechanical seals

  • Meng, Xiangkai;Qiu, Yujie;Ma, Yi;Peng, Xudong
    • Nuclear Engineering and Technology
    • /
    • v.54 no.6
    • /
    • pp.2173-2187
    • /
    • 2022
  • A 3D thermo-elasto-hydrodynamic model is developed to analyze the sealing performance of a notched mechanical seal applied in the reactor coolant pump. In the model, the generalized Reynolds equation, the energy equation coupled with notch heat balance equation, the heat conduction equations, and the deformation equations of the sealing rings are iteratively solved by the finite element method. The film pressure and temperature distribution are obtained, and the deformation of the sealing rings is revealed to study the mechanism of the notched mechanical seals. A parameterized study is conducted to analyze the sealing performance under different operating conditions. As a comparison, the sealing performance of non-notched seals is also studied. The results show that the hydrostatic effect is dominant in the load-carrying capacity of the fluid film due to the radial mechanical and thermal deformations. The notch can cool the fluid film and influence the thermal deformation of seal rings. The sealing performance is sensitive to the pressure difference, ambient temperature, and rotational speed. It is suggested to set the notches on the softer sealing rings to acquire the greater hydrodynamic effect. Compared with the non-notched, the notched end face holds a better lubrication performance, especially under lower rotational speed.

Verification of neutronics and thermal-hydraulic coupled system with pin-by-pin calculation for PWR core

  • Zhigang Li;Junjie Pan;Bangyang Xia;Shenglong Qiang;Wei Lu;Qing Li
    • Nuclear Engineering and Technology
    • /
    • v.55 no.9
    • /
    • pp.3213-3228
    • /
    • 2023
  • As an important part of the digital reactor, the pin-by-pin wise fine coupling calculation is a research hotspot in the field of nuclear engineering in recent years. It provides more precise and realistic simulation results for reactor design, operation and safety evaluation. CORCA-K a nodal code is redeveloped as a robust pin-by-pin wise neutronics and thermal-hydraulic coupled calculation code for pressurized water reactor (PWR) core. The nodal green's function method (NGFM) is used to solve the three-dimensional space-time neutron dynamics equation, and the single-phase single channel model and one-dimensional heat conduction model are used to solve the fluid field and fuel temperature field. The mesh scale of reactor core simulation is raised from the nodal-wise to the pin-wise. It is verified by two benchmarks: NEACRP 3D PWR and PWR MOX/UO2. The results show that: 1) the pin-by-pin wise coupling calculation system has good accuracy and can accurately simulate the key parameters in steady-state and transient coupling conditions, which is in good agreement with the reference results; 2) Compared with the nodal-wise coupling calculation, the pin-by-pin wise coupling calculation improves the fuel peak temperature, the range of power distribution is expanded, and the lower limit is reduced more.

Characteristics Analysis of a Small Scale Persistent Current Switch System by using Coated Conductor (Coated Conductor를 이용한 소용량 영구전류스위치 시스템의 특성 해석)

  • Kim, Yeong-Sik;Yoon, Yong-Soo;Yang, Seong-Eun;Park, Dong-Keun;Ahn, Min-Cheol;Ko, Tae-Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.1
    • /
    • pp.47-52
    • /
    • 2007
  • This paper presents characteristics analysis of persistent current switch(PCS) system on a small scale by using YBCO coated conductor(CC). A high temperature superconductor(HTS) PCS system mainly consists of a PCS, a HTS magnet load and a magnet power supply(MPS). To design the optimal heater triggering switch. the three-dimensional heat conduction model was analyzed by finite element method(FEM). The electrical equivalent model considering the n-value of CC was applied to analyze current decay during persistent current mode. In the experiment and simulation, the heater was applied with a current of 0.43A and the current was ramped up to 10A and 20A with 0.2A/s. Finally, experimental results of the HTS PCS system have been compared with the theoretical results. It has been concluded that flux creep can not influence the results because the operating current was 40% of critical current and optimal sequential operation of the PCS system is indispensable to enhance its performance.

Boundary Elements Heat Transfer Model of Temperature Distribution in Grain Storage Bins

  • T.Abe;C.E.Ofoche;Y.Hikida;Han, D.H.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.922-931
    • /
    • 1993
  • Boundary element method was used to solve heat conduction problem for predicting temperature distribution in grain storage bin. Temperature of grain in storage is one of the three main abiotic factors, besides the intergranular gas composition and the grain moisture content, that determine the keeping quality and control measures used to protect grain from insects and damaging microflora. Collecting the temperature data at various points in the storage bins at different time of the day over a period of time is one way of finding the temperature distribution, this method requires a lot of time, cost and labour and less efficient. However data so collected serve useful purpose of being used to validate predicted temperature distribution using mathematical models. Mathematical models based on physical principles can potentially predict with accuracy the temperature distribution in a grain storage bin. Using the boundary element model the effect of bin wall material, ambient emperature, bin size etc. on temperature distribution can be studied. A knowledge of temperature distribution in stored grain not only helps in identifying active deterioration , but also gives an indication of potential for detection.

  • PDF

Nerve Regeneration Using a Vein Graft Conduit filled with Hyaluronic Acid in a Rat Model (흰쥐 모델에서 하이알루론산을 채운 정맥도관의 신경재생에 관한 연구)

  • Suh, Bo Ik;Kim, Sang Woo;Chung, Ho Yun;Kim, Il Hwan;Yang, Jung Dug;Park, Jae Woo;Cho, Byoung Chae
    • Archives of Plastic Surgery
    • /
    • v.34 no.3
    • /
    • pp.279-284
    • /
    • 2007
  • Purpose: The vein graft was considered as a useful conduit for nerve defect. But the problem is that it might be collapsed in long vein graft state. A new experimental model using vein graft filled with hyaluronic acid was considered. Methods: Thirty rats were used for the experimental animal. In group I, one side of the femoral nerve was exposed and a segment was removed about 15mm. The neural gap was connected with nerve graft. In group II, the nerve gap was connected with vein graft only. In group III, the nerve gap was connected with vein graft filled with hyaluronic acid. A walking track analysis was made periodically for 2 months and NCV(nerve conduction velocity) was executed at the end of the experiment. And morphologic studies were also done for all groups Results: In a walking track analysis, the toe-spread was widen and the foot-length was lengthened. The recovery of the toe-spread and foot length was checked 2 weeks interval, periodically for two months. The SFI (sciatic function index) was $-52.5{\pm}8.2$ in group I, $-68.1{\pm}4$ in group II, $-55.3{\pm}7.9$ in group III. In electrophysiological study, NCV(nerve conduction velocity) was $26.71{\pm}3.11m/s$ in group I, $17.94{\pm}4.35m/s$ in group II, $25.69{\pm}2.81m/s$ in group III. The functional recovery in group I and III was superior to that the group II statistically(p < 0.05) Under electromicroscopic study, the number of the myelinated axons were $1419.1{\pm}240$ in group I, $921.7{\pm}176.8$ in group II, $1322.2{\pm}318$ in group III. The number of the myelinated axons were much more in group I and III than group II statistically (p<0.05). Conclusion: This study suggested that the vein graft filled with hyaluronic acid is more effective than vein graft only for the conduit of the nerve gap. It was thought that the technique could be used in clinical cases with nerve defects as an alternative method to classical nerve grafts.