• 제목/요약/키워드: conduction model

검색결과 523건 처리시간 0.026초

Nonlocal heat conduction approach in biological tissue generated by laser irradiation

  • Abbas, Ibrahim A.;Abdalla, Aboelnour;Sapoor, Hussien
    • Advances in materials Research
    • /
    • 제11권2호
    • /
    • pp.111-120
    • /
    • 2022
  • A novel nonlocal model with one thermal relaxation time is presented to investigates the thermal damages and the temperature in biological tissues generated by laser irradiations. To obtain these models, we used the theory of the non-local continuum proposed by Eringen. The thermal damages to the tissues are assessed completely by the denatured protein ranges using the formulations of Arrhenius. Numerical results for temperature and the thermal damage are graphically presented. The effects nonlocal parameters and the relaxation time on the distributions of physical fields for biological tissues are shown graphically and discussed.

센서망에서 임무 수행 모델 연구 (A study of mission implement model in sensor networks)

  • 박상준;이종찬
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2022년도 추계학술대회
    • /
    • pp.379-380
    • /
    • 2022
  • 본 논문에서는 여러 위험지역에서 임무 수행을 위한 센서 네트워크 그룹의 모델에 대해 제안한다. 특히 그룹 임무 수행에서 하나의 단일한 임무가 아닌 연속적인 임무 수행 시 무선 시스템이 다음 임무를 위한 수행 방식을 고려해야 한다. 임무 수행이 하나의 노드 시스템에 의해 끝나는 것이 아니라 다음 노드에 전달 될 때 수행 특성을 제시해야 한다.

  • PDF

지하수 model에 관한 모형시험방법 (An Introduction to the Ground Water Model Test)

  • 김주욱
    • 한국농공학회지
    • /
    • 제9권2호
    • /
    • pp.1301-1305
    • /
    • 1967
  • Ground water flow can be studied with model test. Model test of ground water works are necessary for economic and safe design of the works. Also influence of the ground water flow to the durability and safety of hydraulic structures can be studied with this model. a. Sand model ; Water flow through porous media is the principle of sand model. Darcy's formula is the basic equation, $q=k{\frac{dh}{ds}}^{\circ}. The effect of the ground water flow on the grain system itself is represented with this model only. b. Hele-Shaw model ; In this model use is made of the viscous flow analogy. Viscous fluid such as glycerine flowing through two parallel plates depends on Poiseuille law, $q=-c{\frac{dh}{ds}}$. The analogue can be used vertically and horizontally. c. Heat model ; This is based on the analogy of the Fourier's law for heat conduction and Darcy's law for ground water flow. Especially unsteady problem can be studied with this model. A difficulty of the construction of this model is the isolation, which has to prevent losses of the heat. d. Electirc model ; Ohm's law for electric current is analogous to Darcy's law. Resistance material such as metal foil, graphite block, water with salt added, gelatine with salt added, ete. is connected to electric sources and resistor, and equi-voltage line is detected with galvanometer, $N_aCl$, $CuSo_4$, etc. are used as salt in the model. e. Membrane model ; This model is based on the facts that the deflection of a thin membrane obeys Laplace's equation if there is no load in the direction perpendicular to the membrane, and if the dellection is small.

  • PDF

나선형코일 튜브 비등2상 유동 수치해석 (Numerical Simulation of Boiling 2-Phase Flow in a Helically-Coiled Tube)

  • 조종철;김웅식;김효정;이용갑
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2004년도 춘계 학술대회논문집
    • /
    • pp.49-55
    • /
    • 2004
  • This paper addresses a numerical simulation of the flow and heat transfer in a simplified model of helically coiled tube steam generator using a general purpose computational fluid dynamic analysis computer code. The steam generator model is comprised of a cylindrical shell and helically coiled tubes. A cold feed water entered the tubes is heated up, evaporates. and finally become a superheated steam with a large amount of heat transferred continuously from the hot compressed water at higher pressure flowing counter-currently through the shell side. For the calculation of tube side two-phase flow field formed by boiling, inhomogeneous two-fluid model is used. Both the internal and external turbulent flows are simulated using the standard k-e model. The conjugate heat transfer analysis method is employed to calculate the conduction in the tube wall with finite thickness and the convections in the internal and external fluids simultaneously so as to match the fluid-wall-fluid interface conditions properly. The numerical calculations are peformed for helically coiled tubes of steam generator at an integral type pressurized water reactor under normal operation. The effects of tube-side inlet flow velocity are discussed in details. The results of present numerical simulation are considered to be physically plausible based on the data and knowledge from previous experimental and numerical studies where available.

  • PDF

Numerical simulation of the thermoelectric behavior of CNTs/CFRP aircraft composite laminates

  • Lin, Yueguo;Lafarie-Frenot, Marie Christine;Bai, Jinbo;Gigliotti, Marco
    • Advances in aircraft and spacecraft science
    • /
    • 제5권6호
    • /
    • pp.633-652
    • /
    • 2018
  • The present paper focuses on the development of a model for simulating the thermoelectric behavior of CNTs/CFRP Organic Matrix Composite (OMC) laminates for aeronautical applications. The model is developed within the framework of the thermodynamics of irreversible processes and implemented into commercial ABAQUS Finite Element software and validated by comparison with experimental thermoelectric tests on two types of composites materials, namely Type A with Carbon Nanotubes (CNT) and Type B without CNT. A simplified model, neglecting heat conduction, is also developed for simplifying the identification process. The model is then applied for FEM numerical simulation of the thermoelectric response of aircraft panel structures subjected to electrical loads, in order to discuss the potential danger coming from electrical solicitations. The structural simulations are performed on quasi-isotropic stacking sequences (QI) $[45/-45/90/0]_s$ using composite materials of type A and type B and compared with those obtained on plates made of metallic material (aluminum). For both tested cases-transit of electric current of intermediate intensity (9A) and electrical loading on panels made of composite material-higher heating intensity is observed in composites materials with respect to the corresponding metallic ones.

시뮬레이션에 의한 저장 벼의 곡온 예측 (Simulation of Temperature Changes of Rough Rice Stored in Round Steel Bin (I) - Development of a Simulation Model -)

  • 금동혁;김재열;김훈
    • Journal of Biosystems Engineering
    • /
    • 제31권4호
    • /
    • pp.355-362
    • /
    • 2006
  • A one-dimensional heat conduction problem in cylindrical coordinate system was solved using Crank-Nicolson finite difference method to predicting the temperature distribution in rice storage bin with wall insulator. The model can simulate the grain temperatures in insulated round bins using the input data of initial grain temperature. ambient air temperature, wind velocity, solar radiation on a horizontal surface, and thermal properties of grain, bin wall, wall insulator, insulator cover, and air. Temperatures were collected at the bin center, 0.65m in radial direction from the center, and near the bin wall in 2.7m diameter bin filled with rough rice to depth of 3.0m were used to validate the simulation model. Grain temperatures predicted by the model were in very good agreement with the measured temperatures. The residual mean square error between measured and predicted grain temperatures at the bin center was $1.38^{\circ}C$.

粒界에서의 터널링으로 解析한 薄膜트랜지스터의 電流-電壓 特性 (I-V Characteristics of the TFT Analyzed by Tunneling in Grain Boundaries)

  • 마대영
    • 대한전자공학회논문지
    • /
    • 제26권6호
    • /
    • pp.23-29
    • /
    • 1989
  • 多結晶 薄膜트랜지스터의 電界效果 解析을 위한 物理的인 모델을 제시하였다. 본 논문의 모델에서는 粒子(grain) 하나를 單結晶 트랜지스터로 粒界(grain boundary)를 電位障壁을 갖는 絶緣體로 가정하였다. 따라서 多結晶 薄膜트랜지스터 粒子인 單結晶 트랜지스터들이 粒界를 경계로 직렬연결 되어 있는 것으로 간주하였으며, 粒子에 흐르는 電流는 gradual channel 근사식으로 또 粒界에 흐르는 電流는 터널링 이론으로 계산하였다. 出力特性과 비교하므로써 채널에서의 電位, 電界분포 등을 구하였으며 이결과들을 통해 본 모델을 검토하였다. 본 논문에서 제시한 다결정박막트랜지스터의 전도모델이 문턱전압이상의 素子동작해석에 타당함을 밝혔다.

  • PDF

Oscillation of Microbeam Structure with Irregular Mass Distribution

  • Kang, Seok-Joo;Kim, Jung-Hwan;Kim, Ji-Hwan
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 춘계학술대회 논문집
    • /
    • pp.528-532
    • /
    • 2013
  • 본 연구에서는, 해석적 모델로 불규칙하게 분포된 질량을 가진 열탄성 댐핑을 포함하는 마이크로빔 구조물을 연구하였다. 마이크로 스케일의 기계적 공명체(mechanical resonator)에 대한 열탄성 댐핑의 중요성은 높은 Q-factor를 설계하는데 고려된다. 본 연구에서의 빔 모델은 Euler-Bernoulli 빔 이론을 기조로 한다. 빔의 고유 진동수를 결정하기 위하여, 에너지 기법이 적용되었다. 또한, 열탄성 댐핑 효과는 열전도 방정식을 사용할으로써 고려되었고, Q-factor가 결정될 수 있었다. 운동방정식의 유도에는 체계적인 무차원화를 수행하였다. 임의의 집중된 질량을 포함하는 열탄성 댐핑을 가진 마이크로빔에 대해 모델의 결과값을 입증하였고 mode shape과 Q-factor를 제시하였다.

  • PDF

전기유변현상 해석을 위하여 Onsager 이론으로 확장한 Maxwell-Wagner 분극 모델 (Extended Maxwell-Wagner Polarization Model with Onsager Theory for the Electrorheological Phenomena)

  • 김영대
    • Korean Chemical Engineering Research
    • /
    • 제56권5호
    • /
    • pp.767-772
    • /
    • 2018
  • 전기유변(ER) 현상을 위해 제시된 메커니즘들이 중에서 정전기 분극 모델과 전도 모델이 이론적인 측면에서 적합한 것으로 알려져 있다. 그러나 이 모델들은 자체적인 제한들 때문에 효과적인 ER 액체의 개발에 적절한 도움이 되지 못했다. 이 문제를 해결하기 위해 Onsager 이론으로 확장한 Maxwell-Wagner 분극 모델을 개발하였다. 확장한 Maxwell-Wagner 분극 모델은 항복응력의 전기장 주파수 및 전기장 크기의 비제곱 의존성을 설명할 수 없는 정전기 분극 모델의 단점과 전기장 하에서의 입자의 미세 구조 변화를 예측할 수 없는 전도 모델의 단점을 해결할 수 있었다. 또한 이 모델은 정전기 분극 모델과 전도 모델에서 예측할 수 없었던 항복응력에의 입자 전도도 영향을 고려할 수 있는 장점도 있어 효과적인 ER 액체의 개발에 기여하리라 판단된다.

Modeling and Analysis of the Fractional Order Buck Converter in DCM Operation by using Fractional Calculus and the Circuit-Averaging Technique

  • Wang, Faqiang;Ma, Xikui
    • Journal of Power Electronics
    • /
    • 제13권6호
    • /
    • pp.1008-1015
    • /
    • 2013
  • By using fractional calculus and the circuit-averaging technique, the modeling and analysis of a Buck converter with fractional order inductor and fractional order capacitor in discontinuous conduction mode (DCM) operations is investigated in this study. The equivalent averaged circuit model of the fractional order Buck converter in DCM operations is established. DC analysis is conducted by using the derived DC equivalent circuit model. The transfer functions from the input voltage to the output voltage, the duty cycle to the output voltage, the input impedance, and the output impedance of the fractional order Buck converter in DCM operations are derived from the corresponding AC-equivalent circuit model. Results show that the DC equilibrium point, voltage ratio, and all derived transfer functions of the fractional order Buck converter in DCM operations are affected by the inductor order and/or capacitor order. The fractional order inductor and fractional order capacitor are designed, and PSIM simulations are performed to confirm the correctness of the derivations and theoretical analysis.