• Title/Summary/Keyword: condition diagnosis

Search Result 1,841, Processing Time 0.03 seconds

Endoscopic features aiding the diagnosis of gastric mucosa-associated lymphoid tissue lymphoma

  • Park, Byung Sam;Lee, Si Hyung
    • Journal of Yeungnam Medical Science
    • /
    • v.36 no.2
    • /
    • pp.85-91
    • /
    • 2019
  • The incidence of gastric mucosa-associated lymphoid tissue (MALT) lymphoma is increasing worldwide, but the diagnosis is difficult. Most patients are asymptomatic or complain of nonspecific gastrointestinal symptoms. As the endoscopic features of gastric MALT lymphoma are variable and nonspecific, the possibility of this condition may be overlooked during esophagogastroduodenoscopy, and it remain undiagnosed. Therefore, this condition needs to be considered when an abnormal mucosa is observed during this procedure. Biopsy performed during endoscopy is the primary diagnostic test, but false negative results are possible; large numbers of samples should be collected from both normal and abnormal mucosae. Endoscopic ultrasonography is useful to assess the depth of invasion and to predict the treatment response. After treatment, follow-up tests are required every 3 months until complete remission is achieved, and annually thereafter. Early diagnosis of gastric MALT lymphoma is difficult, and its diagnosis and follow-up require wide experience and competent endoscopic technique.

Comparison of the effectiveness of various neural network models applied to wind turbine condition diagnosis (풍력터빈 상태진단에 적용된 다양한 신경망 모델의 유효성 비교)

  • Manh-Tuan Ngo;Changhyun Kim;Minh-Chau Dinh;Minwon Park
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.28 no.5
    • /
    • pp.77-87
    • /
    • 2023
  • Wind turbines playing a critical role in renewable energy generation, accurately assessing their operational status is crucial for maximizing energy production and minimizing downtime. This study conducts a comparative analysis of different neural network models for wind turbine condition diagnosis, evaluating their effectiveness using a dataset containing sensor measurements and historical turbine data. The study utilized supervisory control and data acquisition data, collected from 2 MW doubly-fed induction generator-based wind turbine system (Model HQ2000), for the analysis. Various neural network models such as artificial neural network, long short-term memory, and recurrent neural network were built, considering factors like activation function and hidden layers. Symmetric mean absolute percentage error were used to evaluate the performance of the models. Based on the evaluation, conclusions were drawn regarding the relative effectiveness of the neural network models for wind turbine condition diagnosis. The research results guide model selection for wind turbine condition diagnosis, contributing to improved reliability and efficiency through advanced neural network-based techniques and identifying future research directions for further advancements.

Relationship between Gastric Motility and Health Condition Graded by Total Symptom Scores in Comprehensive Diagnosis of Qui Xue Shui in Functional Dyspeptic Patients (기능성 소화불량증 환자의 변증증후(辨證證候)에 의한 건강상태와 위 운동성의 상관성에 대한 연구 (기혈수(氣血水) 변증(辨證)과 위전도 지표를 중심으로))

  • Jeong, Ha-Deok;Kim, Jin-Sung;Ryu, Bong-Ha;Ryu, Ki-Won;Yoon, Sang-Hyub
    • The Journal of Internal Korean Medicine
    • /
    • v.25 no.4
    • /
    • pp.158-166
    • /
    • 2004
  • Background & Object : The aim of this study was to investigate the usefulness of electrogastrography in the diagnosis field of traditional medicine through a study of the relationship between gastric motility and health condition based on oriental medicine diagnostic theory in functional dyspepsia. Method : 86 patients (male 27, female 59) with functional dyspepsia and 10 healthy control subjects (male 5, female 5) were involved in the investigation. The disease information of functional dyspepsia (based on Rome criteria II) was used for dyspeptic index and scores were obtained from the comprehensive diagnosis of Qui, Xue, Shui was applied as index for health condition, those were all investigated by questionnaire. Gastric motility were recorded and analyzed using electrogastrography in fasting and postprandial period. Results : The total score of comprehensive diagnosis of Qui Xue Shui was influenced by the number of functional dyspepsia symptoms (p=0.026). In terms of electrogastrographical parameters, both postpranial normal slow waves regularity(p=0.003) and power ratio (p=0.001) in the patients had the statistical significance and they showed an incremental inverse correlation with the number of symptoms. Dominant frequency and fasting normal slow waves regularity ratio had no statistical significance. Conclusion : Results suggest that electrogastrography is useful in evaluating the health condition of patient by comprehensive diagnosis of Qui Xue Sui.

  • PDF

Development of Tension Leveller Condition Monitoring and Diagnosis System (TENSION LEVELLER 상태감시 및 진단시스템 개발)

  • 신남호;김수광;최석욱
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.350-354
    • /
    • 1995
  • The Tension Leveller of Cold Rolling Mill In POSCO performs levelling the strip in high speed line. But minor variations in operating condition of driving machines such as motor, gear box, and support bearings, a small gap-variation of supporter and strip slip by poor roll revolutions can cause serious problems in the quality of strip. In this study, firstly, A condition monitoring standard for each sensor is made through with the detail analysis of vibration and strip slip. Secondly, An automatic monitoring and diagnosing system was developed to monitor the condition of Tension Leveller, and diagnose the cause of abnormal condition. Finally, A diagnosing algorithm for abnormal condition and man-machine interface (MMI) for easy operation are developed.

  • PDF

The study of non-contact/non-invasive pulse analyzing system using Optical Coherence Tomography (OCT) for oriental pulse diagnosis (비접촉식 광생체단층촬영 기술을 이용한 맥진 연구 -맥의 빠르기, 크기 및 맥력을 중심으로-)

  • Na, Chang-Su;Youn, Dae-Hwan;Kim, Young-Sun;Lee, Chang-Ho;Jung, Woon-Sang;Kim, Jee-Hyun;Choi, Chan-Hun
    • Korean Journal of Acupuncture
    • /
    • v.26 no.2
    • /
    • pp.1-13
    • /
    • 2009
  • Objective: Optical Coherence Tomography (OCT) has emerged as an important optical imaging modality in non-invasive medical diagnostics. Hence, the aim of this study is to measure the similarity of the diagnosis by a traditional method using doctor's hand for feeling of pulse and by the non-contact/non-invasive pulse analyzing system using OCT on Chon(寸), Kwan(關), Chuk(尺). Method: Four korean medical doctors and the non-contact/non-invasive pulse analyzing system using OCT have measured the rapidity, the dimension, and the power of pulse waves of 25 volunteers. First, four korean medical doctors measured pulse waves of volunteers. During measuring, four doctors were separated from each other and so were volunteers. And then, the pulse waves of volunteers were measured by OCT. This was performed on the right Chon(寸), Kwan(關), Chuk(尺). Results: The study showed that the traditional method and the OCT based method had the 88% matches on the values of the slow and rapid pulse condition (遲數), 64% matches on the values of the small and big pulse condition(微細弱緩大[洪]), and 72% matches on the values of the weak and strong pulse condition(虛實). Conclusions: Based on the high similarities of the measurements of two approaches, we suggest that the OCT based pulse diagnosis method is useful for compensating the traditional method for the pulse diagnosis.

  • PDF

Study on Failure Diagnosis of Power Transformer Using FRA

  • Sano, Takahiro;Miyagi, Katsunori
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.6
    • /
    • pp.324-329
    • /
    • 2006
  • As the average usage period of transformers increases, it is becoming increasingly necessary to know the internal condition of transformers. It is therefore critically important to establish monitoring and diagnostic techniques that can perform transformer condition assessment. Frequency response analysis, generally known as FRA, is one of the technologies to diagnose transformers. Using case studies, this paper presents the effectiveness of FRA as measurements for detecting transformer failures. This paper introduces the fact that FRA waveforms have useful information about diagnosis of failure on core earths and winding shield, and that the condition outside transformers can affect frequency response characteristics.

Recent Trend on Condition Monitoring Technology of Insulating Machine in Metro (도시철도 절연기기 모니터링 기술 현황)

  • Park, Young;Jung, Ho-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.380-381
    • /
    • 2008
  • This paper consider the condition monitoring technology of electrical machine in metro substation need for efficient and effective management and diagnosis. Developing management system using condition monitoring system is very competitive field, and still to a great extent seen as an unnecessary cost. There are several approaches to maintenance management in urban transit such as reliability-centered maintenance, availability-target maintenance and preventive maintenance to advanced approaches involving condition monitoring techniques. In this paper we give a brief introduction to condition-based management and diagnosis in metro substation and which management system satisfying various demanding in railway.

  • PDF

The Abnormal Condition Diagnosis of Compressor Parts using Multi-signal Sensing (복합신호 검출에 의한 압축기 부품의 상태 진단)

  • Lee, Kam-Gyu;Kim, Jeon-Ha;Kang, Ik-Su;Kang, Myung-Chang;Kim, Jeong-Suk
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.3 no.3
    • /
    • pp.11-16
    • /
    • 2004
  • In this study, the characteristics of signals such as acoustic emission, vibration amplitude and noise level which are derived from the abnormal condition of compressor are investigated. The normal condition, vane stick sound and roller defect condition are chosen to analyze the signal in each cases. From the feature extraction of each signals, the dominant parameters of each signals which can identify the abnormal condition are suggested.

  • PDF

A Study on the Way of Pulse-diagnosis by Dongeuibogam (동의보감(東醫寶鑑)중 맥법(脈法)에 관한 연구(硏究))

  • Joo, Shin-Tak;Kim, Jung-Guk;Park, Won-Hwan
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.15 no.1
    • /
    • pp.1-28
    • /
    • 2011
  • Objectives: A study on the importance and consistency of pulse-daignosis in the Dongeuibogam Methods: We used Deyeuk Dongeuibogam of Dongeuibogam publishing company from original photographic edition. Results: The frequency of 27 mek (pulse condition) in Dongeuibogam is as in the following. Bumek (Floating pulse) appeared 120(8.9%) times, wanmek (moderate pulse) appeared 28(2%) times, chokmek (running pulse) appeared 7 (0.5%) times, gyumek (hollow pulse) appeared 19 (1.4%) times, saekmek (uneven pulse) appeared 33 (2.4%) times, sapmek (uneven pulse) appeared 51 (3.8%) times, kyulmek (knotted pulse) appeared 18 (1.3%) times, whalmek (slippery pulse) appeared 69 (5.1%) times, chimek (slow pulse) appeared 43 (3.2%) times, demek (intermittent pulse) appeared 13 (1%) times, silmek (replete pulse) appeared 45 (3.3%) times, bokmek (deep-sited pulse) appeared 29 (2.1%) times, neomek (firm pulse) appeared 4 (0.3%) times, hyunmek (taut pulse) appeared 110 (8.1%) times, yumek (soft pulse) appeared 20 (1.5%) times, dongmek (short and rapid pulse) appeared 16 (1.2%) times, kinmek (tense pulse) appeared 67 (5%) times, yakmek (weak pulse) appeared 46 (3.4%) times, semek (thready pulse) appeared 62 (4.6%) times, hongmek (full pulse) appeared 50 (3.7%) times, jangmek (long pulse) appeared 14 (1%) times, sakmek (rapid pulse) appeared 103 (7.6%) times, mimek (indistinctive pulse) appeared 65 (4.8%) times, danmek (short pulse) appeared 16 (1.2%) times, demek (large pulse) appeared 106 (7.9%) times, chimmek (deep pulse) appeared 112 (8.3%) times, heomek appeared 70 (5.2%) times, sanmek (scattered pulse) appeared 14(1%)times. Conclusions: We can know Donguibogam is given on the basis 27mek (pulse condition), because the frequency of 27mek (pulse condition) is high. But there are another expressions. So we can not say that Donguibogam is consistent in expressing mekbub(the way of pulse-diagnosis).

A Study on the Reliability of Failure Diagnosis Methods of Oil Filled Transformer using Actual Dissolved Gas Concentration (유중가스농도를 이용한 유입식 변압기 고장진단 기법의 신뢰성에 관한 연구)

  • Park, Jin-Yeub;Chin, Soo-Hwan;Park, In-Kyoo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.60 no.3
    • /
    • pp.114-119
    • /
    • 2011
  • Large Power transformer is a complex and critical component of power plant and consists of cellulosic paper, insulation oil, core, coil etc. Insulation materials of transformer and related equipment break down to liberate dissolved gas due to corona, partial discharge, pyrolysis or thermal decomposition. The dissolved gas kinds can be related to the type of electrical faults, and the rate of gas generation can indicate the severity of the fault. The identities of gases being generated are using very useful to decide the condition of transformation status. Therefore dissolved gas analysis is one of the best condition monitoring methods for power transformer. Also, on-line multi-gas analyzer has been developed and installed to monitor the condition of critical transformers. Rogers method, IEC method, key gas method and Duval Triangle method are used to failure diagnosis typically, and those methods are using the ratio or kinds of dissolved gas to evaluate the condition of transformer. This paper analyzes the reliability of transformer diagnostic methods considering actual dissolved gas concentration. Fault diagnosis is performed based on the dissolved gas of five transformers which experienced various fault respectively in the field, and the diagnosis result is compared with the actual off-line fault analysis. In this comparison result, Diagnostic methods using dissolved gas ratio like Rogers method, IEC method are sometimes fall outside the ratio code and no diagnosis but Duval triangle method and Key gas method is correct comparatively.