• Title/Summary/Keyword: condensation particle counter

Search Result 49, Processing Time 0.02 seconds

Comparing Exhaust Gas Emission and PN in LPG and CNG Vehicle under FTP-75 and WLTC Test Mode (FTP-75, WLTC 시험 모드에서 LPG, CNG 자동차의 배출가스 및 PN 비교)

  • Jang, Jinyoung;Lee, Youngjae;Kwon, Ohseok;Kim, Jeonghwan
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.6
    • /
    • pp.9-15
    • /
    • 2016
  • Liquefied petroleum gas (LPG) and compressed natural gas (CNG) are often used as fuel for vehicles because they are clean alternative gas fuels. CNG, as a low-carbon fuel, can contribute to the reduction of greenhouse gas emissions. LPG is often used as fuel for taxis because the performance is almost the same as that of gasoline but the price is lower. In the present study, the exhaust gas and the particle number (PN) of particulate matter, which is a recent environmental issue, were compared between LPG and CNG for the same vehicle. A chassis dynamometer was used to conduct the test according to the Federal Test Procedure (FTP)-75 and Worldwide harmonized Light-duty vehicle Test Procedure (WLTC) modes. The PN values of discharged particles having sizes of 5 nm or larger and 23 nm or larger were measured using two condensation particle counters (CPC). The ratio of carbon dioxide was high in the exhaust gas from the LPG vehicle; the ratio of methane was high in the exhaust gas from the CNG vehicle. The PN values of the emitted particles from the two fuels were similar. The PN values of particles having sizes of 23 nm or smaller were high in the high-speed WLTC mode.

On-road Investigation of PM Emissions according to Vehicle Fuels (Diesel, DME, and Bio-diesel) (Diesel, DME, Bio-diesel 연료가 실제 도로 주행 조건에서 입자상물질 배출에 미치는 영향 파악)

  • Lee, Seok-Hwan;Kim, Hong-Seok;Park, Jun-Hyuk;Cho, Gyu-Baek
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.3
    • /
    • pp.88-97
    • /
    • 2012
  • To measure the traffic pollutants with high temporal and spatial resolution under real conditions, a mobile emission laboratory (MEL) was designed. The equipment of the mini-van provides gas phase measurements of CO, NOx, CO2 and THC (Total hydrocarbon), and number density & size distribution measurements of fine and ultra-fine particles by a fast mobility particle sizer (FMPS) and a condensation particle counter (CPC). The inlet sampling port above the bumper enables the chasing of different type of vehicles. This paper introduces the technical details of the MEL and presents data from the experiment in which a MEL chases a city bus fuelled by diesel, DME and Bio-diesel. The dilution ratio was calculated by the ratio of ambient NOx and tail-pipe NOx. Most particles from the bus fuelled by diesel were counted under 300 nm and the peak concentration of the particles was located between 30 and 60 nm. However, most particles in the exhaust of the bus fuelled by DME were nano-particles (diameter: less than 50 nm). The bus fuelled by Bio-diesel shows less particle emissions compare to diesel bus due to the presence of the oxygen in the fuel.

On-road Investigation of PM Emissions of Diesel Aftertreatment Technologies (DPF, Urea-SCR) (차량 추적 실험을 통하여 디젤 후처리 장치가 입자상 물질 배출에 미치는 영향 파악)

  • Lee, Seok-Hwan;Kim, Hong-Seok;Park, Jun-Hyuk;Cho, Gyu-Baek
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.5
    • /
    • pp.92-99
    • /
    • 2011
  • To measure the traffic pollutants with high temporal and spatial resolution under real conditions, a mobile emission laboratory (MEL) was designed. The equipment of the mini-van provides gas phase measurements of CO, NOx, $CO_2$, THC (Total hydrocarbon) and number density & size distribution measurements of fine and ultra-fine particles by a fast mobility particle sizer (FMPS) and a condensation particle counter (CPC). The inlet sampling port above the bumper enables the chasing of different type of vehicles. This paper introduces the technical details of the MEL and presents data from the car chasing experiment of diesel bus equipped with aftertreatment system. The dilution ratio was calculated by the ratio of ambient NOx and tail-pipe NOx. Most particles from the diesel bus were counted under 300 nm and the peak concentration of the particles was located between 30 and 60 nm. The total PM number emission from diesel bus equipped with DPF was 10 orders of magnitude lower compared to those emitted from base diesel bus. And the total PM number emission from diesel bus equipped with SCR was comparable to the particle emission from base diesel bus.

Spatial Distributions of On-road Ultrafine Particle Number Concentration on Naebu Express Way in Seoul during Winter Season (겨울철 서울 내부순환로 도로상 초미세입자 오염의 공간분포 특징)

  • Woo, Daekwang;Lee, Seung-Bok;Lee, Seung Jae;Kim, Jin Young;Jin, Hyun Chul;Kim, Taesung;Bae, Gwi-Nam
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.1
    • /
    • pp.10-26
    • /
    • 2013
  • To understand the traffic emissions with high temporal and spatial resolutions on road, a mobile laboratory was developed. The objective of this study is to characterize on-road air pollution on Naebu express way surrounding the northern area of Seoul, Korea. We measured the number concentration of ultrafine particles larger than 5 nm and particle size distribution using a condensation particle counter and a fast mobility particle sizer, respectively on 3, 7, and 8 December 2009. The average ultrafine particle number concentration on the Naebu express way excluding tunnels was 126,000 particles/$cm^3$ and 4.2 times higher than that on internal road at Korea Institute of Science and Technology in Seoul, and more than twice higher than that measured on and at the arterial roads of Seoul in previous studies. The maximum ultrafine particle number concentration was observed at the tunnel sections. It was 232,000 particles/$cm^3$ and 1.8 times higher than average ultrafine particle number concentration for the other sections on Naebu express way. The ultrafine particle number concentration on the wider roads with higher traffic volume along the Han River was similar to that in the residential section, probably because of enhanced dilution effect in widely open environment. The size distribution of particles on the Naebu express way was highly fluctuated for a short duration. Ultrafine particles measured at the tunnel showed a bimodal size distribution with mode diameters of ~10 nm and ~50 nm. At the Han riverside section, ~10 nm particles appeared significantly compared with size distribution at the tunnel. This on-road measurement approach can be utilized to manage vehicle-related air pollution in urban area.

Fit Performance Comparison Between OPC and CNC Based on Number of Ambient Aerosol Particles (시험환경 내 입자수에 대한 OPC, CNC 장비 간 마스크 밀착 성능비교)

  • Seo, Hyekyung;Jang, Hoyeong;Shim, Sua;Kim, Huiju;Han, Donhee
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.32 no.2
    • /
    • pp.163-171
    • /
    • 2022
  • Objectives: Fit performance may vary depending on the ambient aerosol number and ratio in respective test environment. Although several instrument can measure it, they differ with respect to the measurement principle and the range of ambient aerosols collected to calculate the fit factor. Methods: In this study, the fit performance between a condensation nuclei counter(CNC) and an optical particle counter(OPC) was compared according to ambient aerosol number concentration, and evaluated consistency. One type respirators(N95 masks) was worn by 50 participants PortaCount®(Pro+ 8038) and MT®(05U) were connected with one probe to one mask, and Fit Factors(FFs) were measured simultaneously. Results: The interclass correlation coefficient of the fit factor and ambient aerosol number, as measured by the two instrument, was 0.82 and 0.79, respectively, indicating a high consistency level. On the other hand there was a significant correlation between the successful test performance of the OPC instrument and the ambient aerosol number. Conclusions: The test was passed with the CNC and OPC instruments when the ambient aerosol number was 635-3,332 particles/cm3 and 368-1,976 particles/cm3, respectively. Thus, the ideal ambient aerosol number of particles differed between the two instrument.

Exposures of Ultrafine Particles for Passengers of Elephant Vehicle in the Seoul Grand Park (서울대공원 코끼리 열차 특성에 따른 탑승자의 초극미세입자(Ultrafine Particles) 노출)

  • Joo, Song-Yi;Hwang, Ji-Hee;Ham, Seung-Hon;Lee, Ki-Young
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.5
    • /
    • pp.393-397
    • /
    • 2012
  • Objectives: The objectives of this study were to measure passengers' exposure to ultrafine particles (UFP) and to determine effects of fuel, operating condition and position of seat. Method: UFP exposures in front and back seats of the Elephant vehicle in Seoul Grand Park were simultaneously measured by a condensation particle counter (P-Trak model 8525, TSI). The measurements were conducted 7 times with diesel-powered vehicle and 3 times with electricity vehicle in one day. The vehicle stopped at 3 locations along with 2.2 km of driving route. Results: UFP concentration in diesel-powered vehicle was significantly higher than electricity vehicle. At front seat of diesel-powered vehicle, average UFP exposure during stopping was significantly higher than during moving. When diesel-powered vehicle moved, UFP exposure in back seat was significantly higher than in front seat. Conclusions: Passengers in the diesel-powered Elephant vehicle could be exposed to high level of UFP. The UFP exposure was associated with operation condition and position of seat.

The $SO_2$ effect on NOx removal by Corona Shower System (코로나 샤워 시스템을 이용한 NOx제거에서 $SO_2$의 영향)

  • Park, Jae-Yoon;Kim, Ick-Kewn;Lee, Jae-Dong;Kim, Jong-Dal;Lee, Duck-Chool;Chang, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1794-1796
    • /
    • 1998
  • In this study, the $SO_2$ addition effect on NOx removal has been conducted from a combustion flue gases by the do corona discharge-activated radical shower systems. The simulated flue gases were consisted of NO-O_2-$N_2$, NO-$CO_2-N_2-O_2$ and $NO-SO_2-CO_2-Na-O_2$([NO]o:200ppm and $[SO_2]o$:800ppm). The injection gases used as radical source gases were $NH_3$-Ar-air. $SO_2$ and NOx removal efficiency and the other by-products were measured by Fourier Transform Infrared(FTIR) as well as $SO_2$. NOx and $NO_2$ gas detectors. By-product aerosol particles were also observed by Condensation Nucleation Particle Counter(CNPC) and SEM images after sampling. The results showed that asignificant aerosol Particle formation was observed during a removal operation in corona radical shower systems. The NOx removal efficiency significantly increased with increasing applied voltage and $NH_3$ molecule ratio. The $SO_2$ removal efficiency was not significantly effected by applied voltage and slightly increased with increasing $NH_3$ molecule ratio. The NOx removal efficiency for NO-$SO_2-CO_2-N_2-O_2$ was better than that for NO-$CO_2-N_2-O_2$.

  • PDF

A study on the characteristics of fuel performance according to the oxygenated additive type for gasoline fuel Part 2. Exhaust and Non-regulated, PM emission characteristics (휘발유 연료용 함산소 첨가제 종류에 따른 성능 특성 연구 Part 2. 배출가스 및 미규제 물질, 입자상 물질 특성)

  • Lee, Min-Ho;Kim, Ki-Ho;Ha, Jong-Han
    • Journal of the Korean Applied Science and Technology
    • /
    • v.33 no.2
    • /
    • pp.374-384
    • /
    • 2016
  • Concern about air pollution is gradually rising up in domestic and foreign, automotive and fuel researchers are trying to reduce vehicle exhaust emissions, through a lot of approaches, which consist of new engine design and innovative after-treatment systems, using clean (eco-friendly alternative) fuels and fuel quality improvement. This research is proceeding by two main issues : exhaust emissions and PM particle emissions of gasoline vehicle. Exhaust emissions, non-regulated emissions and PM (particulate matter) particles of automotive are causing many problems which ambient pollution and harmful effects on the human body. The main particulate fraction of automotive exhaust emissions consists of small particles. Because of their small size, inhaled particles can easily penetrate deep into the lungs. The rough surfaces of these particles make it easier for them to combine with other toxins in the environment. Thus, the hazards of particle inhalation are increased. Based on the oxygenated fuel additive types (MTBE, Bio-ETBE, Bio-ethanol, Bio-butanol), this paper discussed the influence of oxygen contents on gasoline vehicle exhaust emissions, non-regulated emissions and nano-particle emissions. Also, this paper assessed exhaust emission characteristics at 2 type test modes. The test modes were FTP-75 and HWFET. All measurement items be verified less than the value of regulated emissions. It could be known difference increase and decrease by each measurement item depending on increase the oxygen contents.

Insights Into Emissions and Exposures From Use of Industrial-Scale Additive Manufacturing Machines

  • Stefaniak, A.B.;Johnson, A.R.;du Preez, S.;Hammond, D.R.;Wells, J.R.;Ham, J.E.;LeBouf, R.F.;Martin, S.B. Jr.;Duling, M.G.;Bowers, L.N.;Knepp, A.K.;de Beer, D.J.;du Plessis, J.L.
    • Safety and Health at Work
    • /
    • v.10 no.2
    • /
    • pp.229-236
    • /
    • 2019
  • Background: Emerging reports suggest the potential for adverse health effects from exposure to emissions from some additive manufacturing (AM) processes. There is a paucity of real-world data on emissions from AM machines in industrial workplaces and personal exposures among AM operators. Methods: Airborne particle and organic chemical emissions and personal exposures were characterized using real-time and time-integrated sampling techniques in four manufacturing facilities using industrial-scale material extrusion and material jetting AM processes. Results: Using a condensation nuclei counter, number-based particle emission rates (ERs) (number/min) from material extrusion AM machines ranged from $4.1{\times}10^{10}$ (Ultem filament) to $2.2{\times}10^{11}$ [acrylonitrile butadiene styrene and polycarbonate filaments). For these same machines, total volatile organic compound ERs (${\mu}g/min$) ranged from $1.9{\times}10^4$ (acrylonitrile butadiene styrene and polycarbonate) to $9.4{\times}10^4$ (Ultem). For the material jetting machines, the number-based particle ER was higher when the lid was open ($2.3{\times}10^{10}number/min$) than when the lid was closed ($1.5-5.5{\times}10^9number/min$); total volatile organic compound ERs were similar regardless of the lid position. Low levels of acetone, benzene, toluene, and m,p-xylene were common to both AM processes. Carbonyl compounds were detected; however, none were specifically attributed to the AM processes. Personal exposures to metals (aluminum and iron) and eight volatile organic compounds were all below National Institute for Occupational Safety and Health (NIOSH)-recommended exposure levels. Conclusion: Industrial-scale AM machines using thermoplastics and resins released particles and organic vapors into workplace air. More research is needed to understand factors influencing real-world industrial-scale AM process emissions and exposures.