• 제목/요약/키워드: concrete strength control

검색결과 849건 처리시간 0.023초

서중 고강도 레미콘 제조 및 품질관리 (Production and Quality Control of Hot Weathered Ready-Mixed High Strength Concrete)

  • 조일호;한정호;방희상;박기청
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1994년도 가을 학술발표회 논문집
    • /
    • pp.423-428
    • /
    • 1994
  • High strength concrete was placed at the mass concrete slabs, walls, pillars of RC building from August till August. And the construction is going on now. This paper presents mix design, production, quality control and experience with field application of high strength ready-mixed concrete under hot weathered conditions. It is shown to be possible to produce high strength concrete that has 45MPa compressive strength using superplasticizer and cement replaced with 20% fly-ash with appropriate control.

  • PDF

TEMPERATURE CONTROL AND COMPRESSIVE STRENGTH ASSESSMENT OF IN-PLACE CONCRETE STRUCTURES USING THE WIRELESS TEMPERATURE MEASURING SYSTEM BASED ON THE UBIQUITOUS SENSOR NETWORK

  • Ho Kyoo JO;Hyung Rae KIM;Tae Koo KIM
    • 국제학술발표논문집
    • /
    • The 3th International Conference on Construction Engineering and Project Management
    • /
    • pp.794-799
    • /
    • 2009
  • The temperature control of in-place concrete is the most important factor for an early age of curing concrete. Heat stress of mass concrete caused by the heat of hydration can induce the crack of concrete, and a frost damage from cold weather casting concrete results defect on compressive strength and degradation of durability. Therefore, success and failure of concrete work is dependant on the measurement and control of concrete temperature. In addition, the compressive strength assessment of in-place concrete obtained from the maturity calculated from the history of temperature make a reduction of construction cycle time, possible. For that purpose, wireless temperature measuring system was developed to control temperature and assess strength of concrete. And, it was possible to monitor the temperature of concrete over 1km apart from site office and to take a proper measure; mesh-type network was developed for wireless sensor. Furthermore, curing control system that contains the program capable to calculate the maturity of concrete from the history of temperature and to assess the compressive strength of concrete was established. In this study, organization and practical method of developed curing control system are presented; base on in-place application case.

  • PDF

혼화재 치환 콘크리트의 압축강도 및 건조수축에 관한 연구 (A Study on the Compressive Strength and Drying Shrinkage of Concrete Depending on Mineral Admixture Kinds)

  • 주은희;손명수;전현규;차천수;김성수;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(II)
    • /
    • pp.253-256
    • /
    • 2005
  • This paper is to investigate the mixture proportion, compressive strength and drying. shrinkage of concrete depending on mineral admixtures such as fly ash (FA), blast furnace slag (BS) and cement kiln dust (CKD) under various contents of admixtures. The use of CKD had little effect on strength development at 3 days, while the use of FA and BS lead to similar compressive strength compared with that of control concrete. Concrete with CKD exhibited a reduction of compressive strength at 91 days, meanwhile concrete with FA and BS had a increase compared with that of control concrete. Drying shrinkage of concrete depending on CKD and BS increase compared with that of control concrete about $10\∼20\%$, while the use of FA exhibited reduce compared with that of control concrete about $10\∼15\%$.

  • PDF

등가재령을 이용한 콘크리트의 강도 예측에 의한 건설생산현장에서의 강도관리에 관한 실험저 연구 (An Experimental Study in Strength Control by Prediction Strength of Concrete using Equivalent Age in Construction Field)

  • 주지현;최성우;박선규;김배수;남재현;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.287-290
    • /
    • 2000
  • Nowadays, strength control is performed by test of compressive strength of concrete which is taken in construction filed. But because it is possible to confirm only compressive strength of concrete by that way, it is difficult to performing strength control pr process plan, So, if we can predict compressive strength of concrete, we can decide when shores and forms can be removed safety, plan process efficiently. This study intends to propose basic data for strength control as determination the time of forwoak removal through investigating propriety of strength prediction using Freiesleben function.

  • PDF

양생초기의 진동시간 제어에 따른 콘크리트의 강도 변화 (Variation of Concrete Strength according to Vibration Time Control for Fresh Concrete)

  • 송규황;김종수;김명식;장희석;김희성
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.675-678
    • /
    • 2003
  • Experimental results for variation of concrete strength according to vibration time control for fresh concrete were given. Vibration velocity, time before vibration and vibrating time were used as experimental parameters. Compressive strength, split tensile strength, ana bond strength were investigated and then fracture surfaces of split tensile strength specimen were observed. From the experimental results, it could be concluded that there may be no decrease in concrete strengths if time before vibration will be sustained at least for more than 3 hours.

  • PDF

Statistical division of compressive strength results on the aspect of concrete family concept

  • Jasiczak, Jozef;Kanoniczak, Marcin;Smaga, Lukasz
    • Computers and Concrete
    • /
    • 제14권2호
    • /
    • pp.145-161
    • /
    • 2014
  • The article presents the statistical method of grouping the results of the compressive strength of concrete in continuous production. It describes the method of dividing the series of compressive strength results into batches of statistically stable strength parameters at specific time intervals, based on the standardized concept of "concrete family". The article presents the examples of calculations made for two series of concrete strength results, from which sets of decreased strength parameters were separated. When assessing the quality of concrete elements and concrete road surfaces, the principal issue is the control of the compressive strength parameters of concrete. Large quantities of concrete mix manufactured in a continuous way should be subject to continuous control. Standardized approach to assessing the concrete strength proves to be insufficient because it does not allow for the detection of subsets of the decreased strength results, which in turn makes it impossible to make adjustments to the concrete manufacturing process and to identify particular product or area on site with decreased concrete strength. In this article two independent methods of grouping the test results of concrete with statistically stable strength parameters were proposed, involving verification of statistical hypothesis based on statistical tests: Student's t-test and Mann - Whitney - U test.

고강도 철근콘크리트 기둥의 파괴거동에 관한 실험적 연구 (An Experimental Study on Failure Modes of High Strength Reinforced Concrete Columns)

  • 최창익;박동규;손혁수;김준범;이재훈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 가을 학술발표회 논문집
    • /
    • pp.442-445
    • /
    • 1997
  • With increasing use of high strength concrete tied columns in structural engineering, it becomes necessary to examine the applicability of related sections of current design codes. High strength concrete has an advantage of strength capacity and stiffness especially for column elements. This paper presents an experimental study of high strength concrete tied columns subjected to eccentric loading. The main variables included in this test were concrete compressive strength, steel amount, eccentricity, and slenderness ratio. The concrete compressive strength varied from 34.9Mpa(356kg/$\textrm{cm}^2$ ) to 93.2Mpa(951kg/$\textrm{cm}^2$ ) and the longitudinal steel ratios were between 1.1% and 5.5%. The eccentricity was selected for the different failure modes, i.e., compression control, balanced point, and tension control. The slenderness ratio varied from 19 to 61. The column specimens with same slenderness ratio but with different concrete compressive strength were constructed and tested. The purpose of this paper is to show failure modes of high strength reinforced concrete columns.

  • PDF

650kgf/$\textrm{cm}^2$ 고강도 콘크리트 한중 시공사례 (Field Application of High Strength Concrete under Cold Weather Conditions)

  • 정재동;노재호;한정호;조일호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1994년도 봄 학술발표회 논문집
    • /
    • pp.260-265
    • /
    • 1994
  • High strength concrete(65MPa) was used for construction of the bulk cement storage silo by using sliding form. This paper presents mix design, production, quality control and experience with field application of high strength concrete under cold weather conditions. It is shown to be possible to produce high strength concrete of compressive strength of 50~60 MPa by using high-range water reducer to lower w/c ratio with appropriate quality control.

  • PDF

우성 캐릭터 199에 고강도 콘크리트 적용에 관한 연구 (The Application of High Strength Concrete on Woo-Sung Character 199 Project)

  • 신성우;안종문;김원섭;김세현
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1996년도 봄 학술발표회 논문집
    • /
    • pp.357-362
    • /
    • 1996
  • The objective of this study is to investigate material properties and quality control of cast-in-place high strength concrete. High strength concrete with a design strength of 420 kgf/$\textrm{cm}^2$ is successfully produced at a ready-mixed concrete plant, and placed at a tall building. Many laboratory and field tests are carried out for the successful construction of the reinforced high strength concrete building. As the results of this study, the average actual 28-day compressive strength is 513 kgf/$\textrm{cm}^2$ and the coefficient of variation is 6.8%. The placing speed is comparable to normal strength concrete, however, the pump pressure is higher than that of normal strength concrete. To prevent cracks of massive and long concrete members, the control of hydration heat and shrinkage is very important.

  • PDF

Crack control of precast deck loop joint using high strength concrete

  • Shim, Changsu;Lee, Chi dong;Ji, Sung-woong
    • Advances in concrete construction
    • /
    • 제6권5호
    • /
    • pp.527-543
    • /
    • 2018
  • Crack control of precast members is crucial for durability. However, there is no clear provision to check the crack width of precast joints. This study presents an experimental investigation of loop joint details for use in a precast bridge deck system. High strength concrete of 130 MPa was chosen for durability and closer joint spacing. Static tests were conducted to investigate the cracking and ultimate behavior of test specimens. The experimental results indicate that current design codes provide reasonable estimation of the flexural strength and cracking load of precast elements with loop joint of high strength concrete. However, the crack width control of the loop joints with high strength concrete by the current design practices was not appropriate. Some recommendations to improve crack control of the loop joint were derived.