• 제목/요약/키워드: concrete specimens

검색결과 3,617건 처리시간 0.028초

Shake-table study of plaster effects on the behavior of masonry-infilled steel frames

  • Baloevic, Goran;Radnic, Jure;Grgic, Nikola;Matesan, Domagoj
    • Steel and Composite Structures
    • /
    • 제23권2호
    • /
    • pp.195-204
    • /
    • 2017
  • The effects of plaster on the behavior of single-story single-bay masonry-infilled steel frames under in-plane base accelerations have been experimentally investigated by a shake-table. Tested structures were made in a 1/3 scale, with realistic material properties and construction methods. Steel frames with high and low flexural rigidity of beams and columns were considered. Each type of frame was tested with three variants of masonry: (i) non-plastered masonry; (ii) masonry infill with conventional plaster on both sides; and (iii) masonry infill with a polyvinyl chloride (PVC) net reinforced plaster on both sides. Masonry bricks were made of lightweight cellular concrete. Each frame was firstly successively exposed to horizontal base accelerations of an artificial accelerogram, and afterwards, to horizontal base accelerations of a real earthquake. Characteristic displacements, strains and cracks in the masonry were established for each applied excitation. It has been concluded that plaster strengthens the infill and prevents damages in it, which results in more favorable behavior and increased bearing capacity of plastered masonry-infilled frames compared to non-plastered masonry-infilled frames. The load-bearing contribution of the adopted PVC net in the plaster was not noticeable for the tested specimens, probably due to relative small cross section area of fibers in the net. Behavior of masonry-infilled steel frames significantly depends on frame stiffness. Strong frames have smaller displacements than weak frames, which reduces deformations and damages of an infill.

화재 후 터널구조물 시공재료의 역학적 특성변화 (Alteration of mechanical properties of tunnel structural members after a tunnel fire accident)

  • 장수호;최순욱;권종욱;김상환;배규진
    • 한국터널지하공간학회 논문집
    • /
    • 제9권2호
    • /
    • pp.157-169
    • /
    • 2007
  • 본 연구에서는 $300^{\circ}C$부터 $1,000^{\circ}C$까지 $100^{\circ}C$간격으로 터널구조물 시공재료별로 목표온도 조건에 따른 중량손실률 및 제반 역학적 특성변화를 측정하였다. 실험 결과, 재료의 역학적 특성이 선형적으로 급격히 저하되는 임계 온도는 $300^{\circ}C$정도이고, 급격한 재료 특성 저하 후 거시적인 파괴로 진전되는 임계 온도는 약 $600^{\circ}C$라는 것을 파악할 수 있었다. 터널구조물 시공재료별로 목표온도에 따른 역학적 특성변화 결과들을 회귀분석한 결과, Bolzmann함수로 최적 회귀함수를 도출할 수 있었다. 최종적으로 화재 시나리오에 따라 터널구조물에 사용되는 시공재료 내부의 온도분포를 쉽게 추정할 수 있으며, 그에 따른 압축강도 및 탄성계수와 같은 역학적 특성들의 저하 정도도 정량적으로 추정할 수 있는 도표를 제시하였다.

  • PDF

The relationship between reinforcing index and flexural parameters of new hybrid fiber reinforced slab

  • Cao, Mingli;Xie, Chaopeng;Li, Li;Khan, Mehran
    • Computers and Concrete
    • /
    • 제22권5호
    • /
    • pp.481-492
    • /
    • 2018
  • In this paper, a new hybrid fiber system (NHFS) is investigated for the application of slab. The steel fiber, polyvinyl alcohol (PVA) fiber and calcium carbonate ($CaCO_3$) whisker is added to form NHFS. The four-point bending test is carried out on the flexural properties of slab with plain, steel fiber, traditional hybrid fiber system (THFS) and NHFS reinforced cementitious composites. The flexural behavior is evaluated by ASTM C1018-97, JCI-SF4 and post-crack strength (PCS) technique. The evaluation parameters of flexural toughness such as toughness index (TI), equivalent flexural strength (EFS) and PCS are determined. The size of slab specimens is $15mm(thickness){\times}50mm(width){\times}200mm(length)$. The results show that adding $CaCO_3$ whisker to THFS can significantly improve the flexural strength, TI, EFS, PCS of the slab. The empirical relation between reinforcing index ($RI_v$) and flexural parameters show that flexural parameters of slabs increase first and then decrease; which indicates that optimum $RI_v$ values can be helpful in the considering the mix design of steel-PVA fibers-$CaCO_3$ whisker composites for achieving the desired flexural-related properties. The scanning electron microscopy is performed to observe the micro-morphological characteristics of the fracture surface, which proved the positive hybrid effect among the different fibers in cementitious composites. The NHFS can arrest the generation and propagation of the crack from micro to macro level.

롤러전압 콘크리트포장의 적정 다짐실험 방안 고찰 (Optimum Compaction Test of Roller Compacted Concrete Pavement)

  • 정건우;이승우
    • 한국도로학회논문집
    • /
    • 제17권3호
    • /
    • pp.27-33
    • /
    • 2015
  • PURPOSES : To ensure appropriate RCC properties with sufficient strength development and workability, it is necessary to secure a proper level of consistency. It is also necessary to secure maximum dry density, which is an important factor for increasing the interaction of aggregate interlocking, leading to an augmentation of RCC strength. On the other hand, the dry density of RCC can be changed owing to the compaction conditions, water content, and particle size distribution. A Proctor test and a modified Proctor test were used for determining the optimum water content needed to achieve maximum dry density with different amounts of compaction energy. A Vebe test, on the other hand, was used for checking the level of consistency, which is important for producing a workable mixture. METHODS : To confirm the degree of compaction at various particle sizes, RCC mixtures with different sand/aggregate ratios were evaluated. The Proctor test and modified Proctor test were applied to these mixtures to check the effect of the aggregate gradation and compaction energy on the maximum dry density and optimum water content. During each test, three specimens were produced for all types of water content under each aggregate gradation. A compaction curve and the optimum water content and maximum dry density for each aggregate gradation were then obtained for both tests. The range of water content for the appropriate consistency of each aggregate gradation was determined through a Vebe test. The optimum water content was then evaluated based on this range. RESULTS : The compaction test results show that the modified Proctor test provides a higher maximum dry density and lower optimum water content compared with the standard Proctor test. For the modified Proctor test, two cases of aggregate gradation (s/a = 30% and 70%) had the optimum water contents outside of the appropriate water content range. For the standard Proctor test, on the other hand, none of aggregate gradations provided the optimum water content within the desired range. CONCLUSIONS : The modified Proctor test should be used for an RCC mixture design because it can provide adequacy between maximum dry density and consistency. Moreover, the compaction roller has become highly developed for higher compaction energy.

강판성형 합성보의 휨성능 평가 -춤이 깊은 합성데크- (Flexural Capacity of the Profiled Steel Composite Beams -Deep Deck Plate-)

  • 허병욱;곽명근;배규웅;정상민
    • 한국강구조학회 논문집
    • /
    • 제19권3호
    • /
    • pp.247-258
    • /
    • 2007
  • 본 논문은 철골보의 하부 플랜지의 높이 조절이 가능하여 합성바닥판의 춤이 자유로운 신형상의 매입형 합성보에 관한 실험적 연구이다. 이를 위하여 강판성형 철골보 단면을 개발하였고 바닥 슬래브용으로 250mm의 춤을 가진 춤이 깊은 데크 플레이트(이하 Deep Deck)를 사용하여 장스팬에 유리하도록 계획하였다. 실험은 전단스터드 및 인장보강근의 사용유무, 사용강판의 두께, 웨브 개구부의 유무를 주요 변수로 하여 총 7개의 매입형 합성보에 대한 단순지지 휨실험 수행하였다. 실험결과, 강판성형 매립형 합성보는 전단연결재의 설치 없이 철골보와 콘크리트의 부착력에 의해 수평전단력이 전달되는 방식임에도 불구하고 대단히 우수한 합성거동을 나타냄을 확인하였다.

성능 개선된 대골형 파형강판의 설계 압축 및 휨 강도 평가에 대한 연구 (A Study on the Evaluation of Design Compressive Strength and Flexural Strength of the Improved Deep Corrugated Steel Plate)

  • 심종성;이현기;강태성
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권3호
    • /
    • pp.155-162
    • /
    • 2011
  • 파형강판을 이용한 구조물은 기존의 철근콘크리트 구조물에 비하여 공기단축효과 및 경제성 등이 우수하고 유지관리비의 절감 측면에서 유리한 것으로 평가되고 있다. 최근 수로암거 및 생태 이동 통로등에 철근콘크리트 암거 대체 재료로 널리 활용되고 있으며 앞으로 적용실적이 더 증가할 것으로 예상된다. 파형강판을 사용한 구조물은 주로 아치형과 박스형의 두가지 형태이며, 아치형 구조물은 압축력에 의하여 설계하며 박스형 구조물은 플레이트 부재내의 모멘트에 의하여 설계한다. 따라서 본 연구에서는 기존의 대골형 파형강판보다 골의 피치와 깊이가 늘어난 성능 개선된 파형강판의 성능을 평가고하고 설계에 반영하기 위해 정적 압축 시험 및 휨시험을 수행하여 시험체 두께별 이음부의 극한강도 및 모멘트 강도를 검토 하였다.

육각형 블록을 이용한 채움벽 RC 골조의 채움벽 내진성능평가 (Seismic Performance Evaluation of Hexagonal Blocks Infilled RC Frames)

  • 장극관;서대원;고태현
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권4호
    • /
    • pp.116-124
    • /
    • 2011
  • 일반적으로 조적조는 시공이 용이하고 경제적인 구조로서 국내뿐만 아니라 해외에서도 가장 오래되고 광범위하게 사용되는 구조이다. 조적벽을 RC 골조에 장막벽으로 사용하는 채움벽 형태의 구조는 시공이 용이하고 경제적이기 때문에 저층 주거용 건물, 학교건물 등에 많이 적용되고 있으나, 설계시에는 비구조부재로 취급되어 채움벽의 효과를 반영하지 않고 있다. 본 연구에서는 기존의 사각형 조적개체의 횡력에 대한 취약성을 개선하기 위해 개발된 육각형 블록을 RC 골조 채움벽에 적용한 채움벽 골조에 대한 구조실험을 수행하여 육각형블록 조적채움벽의 효과를 평가하고자 하였다.

인장력을 받는 확대머리 이형철근의 겹침이음에 관한 실험적 연구 (Experimental Study on Lap Splice of Headed Deformed Reinforcing Bars in Tension)

  • 김승훈
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권5호
    • /
    • pp.59-67
    • /
    • 2014
  • 현행 콘크리트구조기준 (KCI2012) 및 ACI318-11에서 B급이음된 일자형 이형철근에 대하여 인장력에 대한 겹침이음길이를 정착길이의 1.3배로 산정하고 있다. 동일 기준에서 확대머리 이형철근의 정착길이를 제시하고 있지만 겹침이음상세에 대한 규정은 없다. 이에 본 연구에서는 400MPa과 500MPa 설계기준항복강도를 가지는 확대머리 이형철근의 겹침이음실험을 실시함으로써, 기준의 정착길이식을 겹침이음설계에 적용가능한 지를 평가하고자 하였다. 실험결과, SD400과 SD500의 설계기준항복강도를 적용한 확대머리 이형철근에 대하여 겹침이음길이를 정착길이의 1.3배로 산정할 경우, 실험 최대휨강도가 공칭휨강도에 비하여 16~31% 크게 평가되었고 연성적인 휨파괴 거동을 나타내었다. 따라서, 이들 철근에 대해 정착길이 1.3배의 겹침이음길이로 설계함으로써 강도 및 변형성능 측면에서 겹침이음 성능을 확보할 수 있는 것으로 사료된다.

내화유리를 적용한 강재 유리벽의 내화성능 평가 (The Evaluation of Fire-Resistant Performance of the Non-bearing Steel Wall Using Fire Resistant Glass)

  • 이재승;임현창;양승조
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권5호
    • /
    • pp.72-81
    • /
    • 2018
  • 방화구획 내 벽체에는 콘크리트, 조립식 패널, 건식벽체 등을 사용한 내화구조가 주로 적용되고 있으나 근래에 들어 시야 확보 및 미적 관점에 대한 관심이 증가하여 유리로 구성된 벽체의 수요가 발생하고 있다. 본 연구에서는 차열 유리를 적용한 스틸 내화벽체에 관한 것으로써 내부 방화구획에 적용 가능한 60분 내화벽체와 외부 벽체 및 커튼월에 적용 가능한 90분 내화벽체에 대하여 내화시험 및 성능분석을 수행하였다. 시험 결과, 각 시험체의 요구 내화성능을 충족하는 것으로 나타났으며, 추가적으로 유한요소해석을 통한 유리벽체의 내화성능을 평가하였으며 그 결과 1차적으로 시험체의 내화성능을 예측하는 것이 가능한 것으로 판단되었다.

전단경간비에 따른 고강도 SFRC보의 성능 평가 (Capacity Evaluation of High Strength SFRC Beams according to Shear Span to Depth Ratio)

  • 이현호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권3호
    • /
    • pp.76-83
    • /
    • 2014
  • 본 연구의 목적은 고강도 SFRC 보의 강섬유 보강효과를 평가하기 위한 것이다. 이를 위하여 13개의 실험체를 제작하여 성능실험을 실시하였다. 실험 변수는 전단경간비, 강섬유 혼입률, 전단보강근비이며 콘크리트 강도는 60 MPa이다. 기존 연구결과와 재료 및 부재 실험결과에 대한 분석에 의하면, 전단경간비 2.5와 강섬유 혼입률 1.0%인 경우가 강섬유 보강효과가 최대로 발휘되는 것으로 평가되었다. 강섬유 보강 및 전단경간비를 고려한 기존 전단내력식은 고강도 SFRC보의 내력을 과소평가하는 것으로 평가되었다. 향후 고강도 SFRC 보의 강도특성에 대한 보완 연구가 필요한 것으로 판단된다.