• Title/Summary/Keyword: concrete high-rise structures

Search Result 207, Processing Time 0.023 seconds

Raffles City in Hangzhou China -The Engineering of a 'Vertical City' of Vibrant Waves-

  • Wang, Aaron J.
    • International Journal of High-Rise Buildings
    • /
    • v.6 no.1
    • /
    • pp.33-47
    • /
    • 2017
  • This mixed-use Raffles City (RCH) development is located near the Qiantang River in Hangzhou, the capital of Zhejiang province, located southwest of Shanghai, China. The project incorporates retail, offices, housing, and hotel facilities and marks the site of a cultural landscape within the Quianjiang New Town Area. The project is composed of two 250-meter-tall twisting towers with a form of vibrant waves, along with a commercial podium and three stories of basement car parking. It reaches a height of 60 stories, presenting views both to and from the Qiantang River and West Lake areas, with a total floor area of almost 400,000 square meters. A composite moment frame plus concrete core structural system was adopted for the tower structures. Concrete filled steel tubular (CFT) columns together with steel reinforced concrete (SRC) beams form the outer moment frame of the towers' structure. The internal slabs and floor beams are of reinforced concrete. This paper presents the engineering design and construction of this highly complex project. Through comprehensive discussion and careful elaboration, some conclusions are reached, which serve as a reference guide for the design and construction of similar free-form, hybrid, mix-use buildings.

Studies on restoring force model of concrete filled steel tubular laced column to composite box-beam connections

  • Huang, Zhi;Jiang, Li-Zhong;Zhou, Wang-Bao;Chen, Shan
    • Steel and Composite Structures
    • /
    • v.22 no.6
    • /
    • pp.1217-1238
    • /
    • 2016
  • Mega composite structure systems have been widely used in high rise buildings in China. Compared to other structures, this type of composite structure systems has a larger cross-section with less weight. Concrete filled steel tubular (CFST) laced column to box-beam connections are gaining popularity, in particular for the mega composite structure system in high rise buildings. To enable a better understanding of the destruction characteristics and aseismic performance of these connections, three different connection types of specimens including single-limb bracing, cross bracing and diaphragms for core area of connections were tested under low cyclic and reciprocating loading. Hysteresis curves and skeleton curves were obtained from cyclic loading tests under axial loading. Based on these tested curves, a new trilinear hysteretic restoring force model considering rigidity degradation is proposed for CFST laced column to box-beam connections in a mega composite structure system, including a trilinear skeleton model based on calculation, law of stiffness degradation and hysteresis rules. The trilinear hysteretic restoring force model is compared with the experimental results. The experimental data shows that the new hysteretic restoring force model tallies with the test curves well and can be referenced for elastic-plastic seismic analysis of CFST laced column to composite box-beam connection in a mega composite structure system.

Optimum seismic design of reinforced concrete frame structures

  • Gharehbaghi, Sadjad;Moustafa, Abbas;Salajegheh, Eysa
    • Computers and Concrete
    • /
    • v.17 no.6
    • /
    • pp.761-786
    • /
    • 2016
  • This paper proposes an automated procedure for optimum seismic design of reinforced concrete (RC) frame structures. This procedure combines a smart pre-processing using a Tree Classification Method (TCM) and a nonlinear optimization technique. First, the TCM automatically creates sections database and assigns sections to structural members. Subsequently, a real valued model of Particle Swarm Optimization (PSO) algorithm is employed in solving the optimization problem. Numerical examples on design optimization of three low- to high-rise RC frame structures under earthquake loads are presented with and without considering strong column-weak beam (SCWB) constraint. Results demonstrate the effectiveness of the TCMin seismic design optimization of the structures.

Vibration Control of RC Residential Building Structure Using Sky-Bridge (스카이브릿지를 이용한 RC 주거용 건물의 진동제어)

  • Ahn, Sang-Kyung;Oh, Jung-Keun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.450-453
    • /
    • 2006
  • Coupling adjacent building with supplemental damping devices is a developing method of reduced structural response due to wind and seismic excitations. The philosophy is to allow structures, vibrating at different frequencies, to exert control forces upon one another to reduce the overall responses of the system. This paper studies the effect of installing vibration control devices of two high rise building structures(49 stories and 42 stories) connected by sky-bridge. According to the analysis results the use of sky-bridge can be effective in increasing damping ratio of the system.

  • PDF

Effect of Mixed Use of Fine Aggregates on the Flowability of Ultra High Strength Concrete (잔골재 혼합사용이 석회암 굵은 골재 사용 초고강도 콘크리트의 유동특성에 미치는 영향)

  • Lee, Hong-Kyu;Kim, Min-Young;Lee, Sun-Jae;Jo, Man-Ki;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.73-74
    • /
    • 2015
  • As this study is one related to ultra high strength concrete using crushed coarse limestone aggregates among the series of experiments for improving the economic inefficiency of the ultra high strength concretes used for high rise structures, it has analyzed the flowability of ultra high strength concrete according to the variation of blended fine aggregates. As a result of analyzing the characteristics of fresh concrete, it is determined that the application of ultra high strength concrete would be difficult in case of a mix using blended fine aggregates as lower flowability than the mix using limestone crushed fine aggregate only was shown in all mixes using blended fine aggregates.

  • PDF

An Experimental Study on the Semi-Adiabatic Temperature Rise Test of Concrete Considering Outside Temperature and Specimen Size (외기온도 및 시험체 크기를 고려한 콘크리트의 간이-단열온도 상승시험에 관한 실험적 연구)

  • On, Jeong-Kwon;Kim, Young-Sun;Moon, Hyoung-Jae;Nam, Jeong-Soo;Kim, Gyu-Yong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.6
    • /
    • pp.563-571
    • /
    • 2021
  • Recently, due to the increase in high-rise apartment and residential-commercial complex buildings, a number of mega-class mass concrete members with a thickness of 3m or more have been designed. As the construction of mass concrete such as transfer beam and slab is increasing not only in foundation members but also in special structures, research on reducing temperature cracks in mass concrete is being conducted. To review temperature cracks in mass concrete, it is important to review the thermal properties of concrete, but it is difficult to use an adiabatic temperature rise tester in the field, so the semi-adiabatic temperature rise test is mainly used. In this study, to improve the accuracy of the results of concrete heat characteristics gained by the semi-adiabatic temperature rise test, various factors affecting heat loss compensation and methods were reviewed and presented.

Temperature Crack Control about Sidewall of LNG in Inchon (인천 LNG지하탱크 Sidewall의 온도균열제어)

  • Koo, Bon-Chang;Kim, Dong-Seuk;Ha, Jae-Dam;Kim, Ki-Soo;Choi, Long;Choi, Woong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.329-332
    • /
    • 1999
  • The crack of concrete induced by the heat of hydration is a serious problem, particularly in concrete structures such as underground box structure, mat-slab of nuclear reactor buildings, dams or large footings, foundations of high rise buildings, etc.. As a result of the temperature rise and restriction condition of foundation, the thermal stress which may induce the cracks can occur. Therefore the various techniques of the thermal stress control in massive concrete have been widely used. One of them is prediction of the thermal stress, besides low-heat cement which mitigates the temperature rise, pre-cooling which lowers the initial temperature of fresh concrete with ice flake, pipe cooling which cools the temperature of concrete with flowing water, design change which considers steel bar reinforcement, operation control and so on. The objective of this paper is largely two folded. Firstly we introduce the cracks control technique by employing low-heat cement mix and thermal stress analysis. Secondly it show the application condition of the cracks control technique like sidewall of LNG in Inchonl.

  • PDF

Prediction and Measurement of Differential Column Shortening in High-rise Building Structures (고층건물의 부등축소량 예측 및 계측)

  • 정금진;양근혁;이정한;홍재원;이원호;정헌수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.511-516
    • /
    • 2000
  • A Hybrid Wall System(HWS) building, Kolon Bundang Tripolis was instrumented to measure the vertical deformation of core-walls and columns. The vertical shortening of individual members were measured at selected floor levels such as 1F, 12F, 25F, and 34F. The measurement has been taken during one year after the construction was started. Together with the measurement, concrete property tests were performed in the laboratory using the concrete obtained in the field. The measured vertical shortenings were compared with the calculated prediction values and the satisfactory agreement was obtained.

  • PDF

Parametric study on bearing capacity of CFST members considering the concrete horizontal casting effect

  • Sun, Wenbo;Luo, Yiqun;Zhou, Weijian;Huang, Wei
    • Steel and Composite Structures
    • /
    • v.13 no.3
    • /
    • pp.259-275
    • /
    • 2012
  • Concrete filled steel tubular (CFST) member has been widely used in the construction of high-rise buildings for its high axial bearing capacity. It can also be applied on long-span structures such as spatial structures or bridges not only for its high bearing capacity but also for its construction convenience. Concrete casting effect of CFST member is considered in the study of its bearing capacity in this paper. Firstly, in order to authenticate the applicability of constitutive relationship and yield criterion of steel and concrete based on FEM, two ANSYS models are built to simulate and compared with other's test. Secondly, in order to find the huge difference in bearing capacity due to different construction processes, two full-size CFST models are studied when they are horizontally cast and axially compressed. Finally, the effects of slenderness ratio (L/D) and confining parameter (D/t) of CFST members are studied to reveal the intrinsic links between bearing capacity and slenderness ratio or confining parameter.

Correlation of Experimental and Analytical Inelastic Responses of A 1:12 Scale 10-Story Masonry-Infilled Reinforced Concrete Frame (1:12축소 10층 조적 채움 R.C. 골조의 비선형 거동에 대한 실험과 해석의 상관성)

  • 이한선;김정우
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.1
    • /
    • pp.101-112
    • /
    • 2000
  • In many structures, the masonry infill panels have been used for architectural reasons and their influence on the structure is often ignored by engineers. However, it has been recognized that the presence of masonry infills may debates. Recently, the pushover analysis technique is used for the prediction of the inelastic behaviors of structures in the seismic evaluation of existing buildings. However, the reliability of this analysis method has not been fully checked with the test results, particularly in the case of masonry-infilled frames. The objective of this study is to verify the correlation between the experimental and analytical reponses of a high-rise masonry-infilled reinforced concrete frame using DRAIN-2DX program and the test results performed previously. It is concluded from this comparison that the strength and stiffness of members can be predicted with quite high reliability while the ductility capacity of members can not be described reasonably.