• 제목/요약/키워드: concrete floating structure

검색결과 48건 처리시간 0.023초

Analysis of a preliminary configuration for a floating wind turbine

  • Wang, H.F.;Fan, Y.H.;Moreno, Inigo
    • Structural Engineering and Mechanics
    • /
    • 제59권3호
    • /
    • pp.559-577
    • /
    • 2016
  • There are many theoretical analyses and experimental studies of the hydrodynamics for the tension leg platform (TLP) of a floating wind turbine. However, there has been little research on the arrangement of the TLP's internal structure. In this study, a TLP model and a 5-MW wind turbine model as proposed by the Minstitute of Technology and the National Renewable Energy Laboratory have been adopted, respectively, to comprehensively analyze wind effects and wave and current combinations. The external additional coupling loads on the TLP and the effects of the loads on variables of the internal structure have been calculated. The study investigates preliminary layout parameters-namely, the thickness of the tension leg body, the contact mode of the top tower on the tension leg, the internal stiffening arrangement, and the formation of the spoke structure-and conducts sensitivity analyses of the TLP internal structure. Stress is found to be at a maximum at the top of the tension leg structure and the maximum stress has low sensitivity to the load application point. Different methods of reducing maximum stress have been researched and analyzed, and the effectiveness of these methods is analyzed. Filling of the spoke structure with concrete is discussed. Since the TLP structure for offshore wind power is still under early exploration, arrangements and the configuration of the internal structure, exploration and improvements are ongoing. With regard to its research and analysis process, this paper aims to guide future applications of tension leg structures for floating wind turbine.

Effect of Wave Load on the Member Force of Steel Structure of Floating Buildings

  • Lee, Young-Wook;Park, Tae-Jun
    • 국제강구조저널
    • /
    • 제18권4호
    • /
    • pp.1431-1439
    • /
    • 2018
  • For floating buildings may fl oat on the water for a long time, they are constantly affected by various environmental loads such as wind and wave loads. In this study to find the wave effect on the floating building, five models are designed using steel moment resisting frame. It is assumed that the lower part of the floating building is a reinforced concrete pontoon, while the upper part is a three-story steel frame. To analyze floating buildings affected by wind and wave loads, hydro-dynamic and substructure analysis are performed. As input loads, this study set limits that the mean wind velocity is 35 m/s and the significant wave height is 0.5 m for the residential building. From the hydrodynamic analysis, the time-history acceleration of building is obtained and transformed into a base ground input for a substructure analysis of the superstructure of the building. Finally the mean of the maximum from 30 dynamic analysis of the floating buildings are used to be compared with the results of the same model on the ground. It was shown that the dynamic results with wind and wave loads are not always lesser than the static results which are calculated with static equivalent wind load for a building that is located on the ground.

시공단계를 고려한 플로팅 폰툰의 상부구조물 해석기법 (Analysis method of the Superstructure on Floating Pontoon Considering the Construction Sequences)

  • 이영욱;채지용
    • 한국항해항만학회지
    • /
    • 제36권3호
    • /
    • pp.225-232
    • /
    • 2012
  • 본 연구에서는 수상위에 진수된 콘크리트 플로팅 폰툰에 상부골조를 단계별로 시공함에 따라 발생하는 추가 처짐이 상부골조에 발생하므로 추가변형에 의한 상부골조의 추가 모멘트량을 산정하는 해석절차를 제시하였으며 제시된 절차에 따라 3층 예제 철골 건물을 해석하고 분석하였다. 제시된 시공단계를 고려한 해석 방법과 비교하여, 폰툰의 변형을 고려하지 않는 해석 방법은 수직하중에 의한 변형을 무시하여 설계하중을 과소평가 하며, 플로팅 구조물을 전 층을 모델링하고 하중을 동시에 작용시키는 모델은 과대 처짐의 영향으로 설계하중을 과대평가함을 알게 되었다.

하천 부유쓰레기에 대한 분광라이브러리 특성 분석 (Analysis on Characteristics of Spectral Library to River Floating Debris)

  • 이준호;윤홍주
    • 한국전자통신학회논문지
    • /
    • 제13권3호
    • /
    • pp.623-632
    • /
    • 2018
  • 본 연구는 하천 저수구역에 대하여 하천의 부유쓰레기를 탐지하고, 이때 동시에 분광라이브러리 특성들을 분석하여 효율적인 하천환경관리기술의 기초자료로 활용하는데 목적을 두었다. 부유쓰레기 탐지 구간으로 달성보-강정고령를 중심으로 현장 조사 계획을 수립하였다. 분광반사측정은 하천 주변의 식생(초지, 수목 등), 인공물(콘크리트, 구조물 등), 하천수(청수, 탁수, 녹조), 하천 주변에 산재되어 있는 하천 부유쓰레기를 대상으로 하였으며 그리고 동시에 현장에서 조사된 하천 부유쓰레기들에 대한 분광라이브러리 특성들을 각각 분석하였다.

도시철도 궤도형식별 궤도 충격계수 산정을 위한 실험적 연구 (An Experimental Study on the Evaluation of Track Impact factor on the Various Track Type in Urban Transit)

  • 김재원;김만철;박용걸
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.382-399
    • /
    • 2011
  • Impact factor of concrete and ballast track which has been used in Korea railway was applied to equation (1+0.513V/100) from AREA. As the use of this equation, overcapacity of track design might be occurred. Therefore, this study compared impact of ballast track (well, bad) and concrete track (sleeper embeded system, rail floating and sleeper floating) by field test to analyzing dynamic effect of track structure's characteristic and wheel load on service line. In addition, it suggested a method to generate reasonable track impact factor on each track type.

  • PDF

폐타이어 칩의 바닥충격음 차단성능에 관한 실험적 연구 (The Experimental Study on the Impact Sound Insulation Floors due to Waste Tire Chip)

  • 양관섭;이세현;김홍열;김승민
    • 소음진동
    • /
    • 제9권3호
    • /
    • pp.477-484
    • /
    • 1999
  • This study aims to present proper thickness of resilient mount and pattern of chips for the improvement of impact sound isolation. To achieve this aim, field tests were performed to evaluate the performance of impact sound isolation of pilot samples using waste tire chips against light and heavy-weight impacter, which samples were installed over concrete slabs of an apartment housing. In this study, the experiments were performed by the impact sound level of floors in KS F 2810 "Method for field measurement of floor impact level". As results, a flooring structure using waste tire chips as a resilient mount, with no relation to chip's types, has enhanced performance by 1~2 degree in light impact sound isolation, while it has improvement in heavy impact sound isolation. And fiber-type chips have better performance than granule-type ones when they overlaid concrete slab with 15~20 mm of thickness. For the improvement of impact sound isolation, it is recommended that insulating materials should be applied at joints between floating floors and walls, or floating floors and a doorframes, and also waterproof papers should be used for the effective thickness of resilient mount.ent mount.

  • PDF

모달시험기법을 이용한 침목플로팅궤도의 고유진동수 분석 (Natural Frequency Analysis of Sleeper Floating Track System using Modal Test Technique)

  • 최정열
    • 문화기술의 융합
    • /
    • 제10권3호
    • /
    • pp.833-838
    • /
    • 2024
  • 도시철도 침목플로팅궤도(STEDEF)는 침목상자와 침목방진패드를 이용하여 침목과 콘크리트 도상을 구조적으로 분리하여 콘크리트 도상에 전달되는 진동을 감소시키는 구조이다. 최근에는 20년 이상 공용중인 침목플로팅궤도의 침목방진패드 열화가 발생하고 있다. 이에 침목방진패드에 대한 성능을 평가하기 위해 침목방진패드 발췌 후 정적 스프링강성 시험을 수행하고 있다. 해당 평가기법은 사용 중인 침목방진패드를 반드시 교체한 후 평가를 수행한다. 그러나 궤도 고유진동수는 침목방진패드 스프링강성 및 콘크리트 도상의 융기와 침하에 따라 변화할 수 있다. 본 연구에서는 궤도 고유진동수를 평가하기 위해 모달시험기법을 사용하였다. 이를 위해 실험실 규모에서 침목상자 소재, 침목방진패드 스프링강성 및 콘크리트 도상 융기 및 침하에 따른 궤도 고유진동수를 모달시험을 이용하여 측정하였다. 침목플로팅궤도 고유진동수는 침목방진패드 스프링강성 변화에 따라 직접적인 영향을 받는 것으로 분석되었다. 또한 콘크리트 도상의 융기 및 침하에 따른 고유진동수 변화도 큰 것으로 나타났다. 따라서 본 연구에서 제시한 모달시험기법을 이용하여 침목방진패드의 열화 및 뜬 침목 평가 등에 활용할 수 있을 것으로 판단된다.

벽식구조 바닥판의 중량충격음 특성 분석을 위한 축소모형의 활용 (Experimental Studies for Analysing of Characteristics of Floor Impact Sound through a Scale Model with Box-frame Type Structure)

  • 유승엽;전진용
    • 한국소음진동공학회논문집
    • /
    • 제21권9호
    • /
    • pp.805-812
    • /
    • 2011
  • This study investigated the characteristics of heavy-weight floor impact sounds of box-frame type structure using 1:10 scale model. Ten types of floor structures(bare slabs and floating floors) were evaluated in terms of dynamic stiffness and loss factor. Floor vibrations and radiated sounds generated by simulated impact source were also measured. The results showed that the bakelite was appropriate for simulating concrete slab in the 1:10 scale model, and surface velocity and sound pressure level of concrete slab measured from the scale model showed similar tendencies with the results from in-situ in frequency domain. It was also found that dynamic behaviors of layered floor structures in the 1:10 scale model were similar to those in a real scale. Therefore, the use of 1:10 scale model would be useful for evaluating the heavy-weight floor impact sound insulation of layered floor structures when the frequency-dependent dynamic properties of each material are known.

면섬유가 보강된 폴리우레탄계 복합시트의 기초 물성 평가 (Evaluation on the Basic Properties of Polyurethane Composite Sheet Reinforced with Non-Woven Fabric)

  • 김지현;도승배;박정원;남기융;정철우
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.238-239
    • /
    • 2017
  • Waterproofing is a very important process in terms of durability of buildings. The materials used for waterproofing work to protect the concrete structure from external deterioration factors. In particular, the waterproofing materials applied to the exterior of the concrete structure have various problems due to changes in the external environment and variables in the construction process. The waterproof layer is repeatedly dried and shrunk according to changes in the external moisture environment, and the surface may be deteriorated due to exposure to long-term sunlight. In the case of the roof waterproofing in the structure, the waterproof layer which does not have a sufficient curing period shows much swelling and floating phenomenon. These defects, such as swelling and lifting, account for most of the defects that occur in the waterproof layer of the concrete slabs. Generally, it is difficult to expect the same level of performance as the initial state even if the waterproofing work is repaired when a defect occurs. Therefore, it is possible to reduce the defects of the waterproof layer such as swelling and lifting by forming a waterproof layer which can be integrated with the concrete surface by using a polyurethane type waterproofing material having a relatively low defective ratio compared to other waterproofing materials. So in this study, the basic properties of polyurethane waterproof sheet reinforced with non-woven fabric are investigated in order to understand field applicability.

  • PDF

고성능 바닥충격음 차단구조 개발에 관한 연구 (A Study on the Development of High Performance Floor Impact Noise Insulation System)

  • 장재희
    • KIEAE Journal
    • /
    • 제7권2호
    • /
    • pp.71-76
    • /
    • 2007
  • For the many years the children's running noise has caused perpetual frictions between neighbors in apartment houses. For this reason the government established a regulation to reduce the floor impact noise, as a result almost all apartment houses have been enforced to use the floor structure with 210mm thickness concrete slab and 120mm thickness of floor heating system since July 2005. If do not want to apply this kind of system, a system which obtain the certification from the institution appointed by government must be applied. In this reason a lot of construction material companies and construction companies have been trying to develop the system with 180mm thickness concrete slab for the purpose of reducing the cost. To develop the optimized floor system, actual size test building were constructed and the materials related with reducing floor impact noise were composited and tested in the test building. Through this procedure the most effective system was found.