Structural Behavior of Post-Tensioned Flat Plate Slab-Column Connections (포스트 텐션 플랫 플레이트 슬래브 접합부의 거동)

  • Cho Kyung Hyun;Han Sang Whan;Lee Li-Hyung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.53-56
    • /
    • 2004
  • Recently, post tension flat plate slab system is widely used for a new slab structural system. Slab-column connections may fail in brittle manner by punching shear. Flat plate slabs have been widely used for gravity load resisting system in buildings. Lateral resistance usually provided by shear walls or moment resisting frames. Since plat plates move together with lateral loading system during earthquake or wind, it is important to evaluate the gravity resistance under a drift experienced by lateral force resisting system during either design earthquake or wind. Thus, this study investigated post tension flat plate slab systems whether they have sufficient strength and deformability to resist gravity loads during specified drift levels. Experimental research was carried out.

  • PDF

Shear and impact strength of waste plastic fibre reinforced concrete

  • Karanth, Savithri S;Ghorpade, Vaishali G;Rao, H Sudarsana
    • Advances in concrete construction
    • /
    • v.5 no.2
    • /
    • pp.173-182
    • /
    • 2017
  • This paper is aimed at determining the shear and impact strength of waste plastic fibre reinforced concrete. M30 grade of concrete is prepared with waste plastic door fibres cut into 5 mm width and aspect ratios of 30, 50, 70, 90 and 110. Fibres are used in a volume fraction of 0 to 1.5% with an increment of 0.25%. L shaped specimens are cast for shear strength tests and flat plates of size $250{\times}250{\times}30mm$ are used for impact tests. "Drop ball method" is used for checking the impact strength. Shear strength is checked with L shaped specimens under UTM with a special attachment. It was found that up to 1.25% of waste plastic fibres can be effectively used for better strength of concrete both in shear and impact. Shear and impact strength were found to be increasing up to a volume fraction of fibres of 1.25%.

Moment Magnifier Method for RC Flat Plate Subject to Combined Axial Compressive and Floor Load (면내 압축력을 받는 플랫 플레이트 슬래브에 대한 모멘트 증대법)

  • Park, Hong-Gun
    • Magazine of the Korea Concrete Institute
    • /
    • v.11 no.1
    • /
    • pp.243-254
    • /
    • 1999
  • This paper presents a numerical study for developing the moment magnifier method that is applicable to RC flat plates subject to combined axial compressive and floor load. For the nonlinear finite element analysis, a computer program addressing material and geometric nonlinearities was developed. The flat plates to be studied are designed in accordance with the Direct Design Method in Korean Building Code for Structural Concrete. This paper proposes the buckling force and the moment magnification factor for the flat plate under the governing load condition that is the combined vertical and subsequently applied uniaxial compressive load. The buckling force is defined with two ingredients: the buckling coefficient and the effective flexural rigidity. Parametric studies are performed to investigate variations of the buckling coefficient and the effective flexural rigidity. Based on the numerical results, this paper provides the design values of the buckling coefficient and the effective flexural rigidity, and the design procedure for the moment magnifier method.

Effective Beam Width Coefficients for Lateral Stiffness in Flat-Plate Structures

  • Park, Jung-Wook;Kim, Chul-Soo;Song, Jin-Gyu;Lee, Soo-Gon
    • KCI Concrete Journal
    • /
    • v.13 no.2
    • /
    • pp.49-57
    • /
    • 2001
  • Flat-plate buildings are commonly modeled as two-dimensional frames to calculate unbalanced moments, lateral drift and shear at slab-column connections. The slab-column frames under lateral loads are analyzed using effective beam width models, which is convenient for computer analysis. In this case, the accuracy of this approach depends on the exact values of effective beam width to account for the actual behavior of slab-column connections. In this parametric study, effective beam width coefficients for wide range of the variations are calculated on the several types of slab-column connections, and the results are compared with those of other researches. Also the formulas for effective beam width coefficients are proposed and verified by finite element analysis. The proposed formulas are founded to be more suitable than others for analyzing flat-plate buildings subjected to lateral loading.

  • PDF

Nonlinear modeling of flat-plate structures using grid beam elements

  • Tian, Ying;Chen, Jianwei;Said, Aly;Zhao, Jian
    • Computers and Concrete
    • /
    • v.10 no.5
    • /
    • pp.489-505
    • /
    • 2012
  • This paper presents a simplified grid beam model for simulating the nonlinear response of reinforced concrete flat-plate structures. The beam elements are defined with nonlinear behavior for bending moment and torsion. The flexural stiffness and torsional strength of the beam elements are defined based on experimental data to implicitly account for slab two-way bending effects. A failure criterion that considers the interaction between the punching strength and slab flexural behavior is incorporated in the model. The effects of bond-slip of slab reinforcement on connection stiffness are examined. The proposed grid beam model is validated by simulating large-scale tests of slab-column connections subjected to concentric gravity loading and unbalanced moment. This study also determines the critical parameters for a hysteretic model used to simulate flat-plates subjected to cyclic lateral loading.

Span-to-Depth Ratio Equation for Reinforced Concrete Floor Members (콘크리트 바닥부재 설계를 위한 최소두께 산정식 제안)

  • Lee, Young-Hak;Chung, Kwang-Ryang;Choi, Bong-Seob
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.205-208
    • /
    • 2005
  • A single span-to-depth ratio function is proposed for control of deflection in one-way concrete construction. The equation can be applied to one-way slabs, beams, and flat plates. Effects of cracking, time-dependent deformation, boundary conditions, applied loading, and target deflection-to-span ratio are taken into account.

  • PDF

Numerical study on effect of integrity reinforcement on punching shear of flat plate

  • Ahsan, Raquib;Zahura, Fatema T.
    • Computers and Concrete
    • /
    • v.20 no.6
    • /
    • pp.731-738
    • /
    • 2017
  • Reinforced concrete flat plates consist of slabs supported directly on columns. The absence of beams makes these systems attractive due to advantages such as economical formwork, shorter construction time, less total building height with more clear space and architectural flexibility. Punching shear failure is usually the governing failure mode of flat plate structures. Punching failure is brittle in nature which induces more vulnerability to this type of structure. To analyze the flat plate behavior under punching shear, twelve finite element models of flat plate on a column with different parameters have been developed and verified with experimental results. The maximum range of variation of punching stress, obtained numerically, is within 10% of the experimental results. Additional finite element models have been developed to analyze the influence of integrity reinforcement, clear cover and column reinforcement. Variation of clear cover influences the punching capacity of flat plate. Proposed finite element model can be a substitute to mechanical model to understand the influence of clear cover. Variation of slab thickness along with column reinforcement has noteworthy impact on punching capacity. From the study it has been noted that integrity reinforcement can increase the punching capacity as much as 19 percent in terms of force and 101 percent in terms of deformation.

Comparison of Shear Strength Equation for Flat Plates with GFRP Plate (GFRP 판으로 보강된 플랫 플레이트의 전단강도식에 관한 규준의 비교 분석)

  • Kim, Min Sook;Hwang, Seung Yeon;Kim, Heecheul;Lee, Young Hak
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.27 no.4
    • /
    • pp.247-254
    • /
    • 2014
  • In this study, shear test performed to investigate the shear behavior of flat plate that reinforced by embedded GFRP(glass fiber reinforced polymer) plate with openings. Shape of the GFRP shear reinforcement is a plate with several openings to ensure perfect integration with concrete. The test parameters include the distance between the column face and the first line of GFRP plate and number of GFRP plate vertical strip. The result of test showed that when number of GFRP plate vertical strip was increased, shear strength improved. The shear strength for flat plate reinforced GFRP plate in various codes including ACI 318, BS 8110, EUROCODE 2, and KCI were compared to provide more rational approach for reinforced concrete flat plates with GFRP plate.

Analytical Study on Punching Shear of Reinforced Concrete Flat Plates (철근콘크리트 플랫 플레이트의 뚫림전단 거동에 관한 해석적 연구)

  • Kim, Min-Sook;Lee, Young-Hak;Kim, Hee-Cheul
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.4
    • /
    • pp.409-415
    • /
    • 2010
  • A finite element model for punching shear of flat plate structures is presented. A parametric study also has been conducted to verification of influence of several parameters in terms of the flexural reinforcement ratio, slab thickness. Reisnner-Mindlin assumptions are adopted to consider of shear deformation. Layered shell element is considered for the material non-linearities. The finite element model of this study was verified comparing with existing experimental results. The model is able to predict the capacity of the flat plate structures. The punching shear of flat plate structures varied depending on the flexural reinforcement ratio, slab thickness.