• Title/Summary/Keyword: concrete filled double steel tube column

Search Result 24, Processing Time 0.019 seconds

The effect of rectangular and T-shaped stiffeners on the seismic performance of CFDT columns

  • Mojtaba Labibzadeh;Keyvan Parsa;Farhad Hosseinlou;Majid Khayat
    • Earthquakes and Structures
    • /
    • v.27 no.3
    • /
    • pp.191-207
    • /
    • 2024
  • Due to the many advantages of concrete-filled double steel tube (CFDT) columns, they are highly recommended for use in heavy-load structures such as bridges, subway stations, and high-rise buildings. This study was carried out with the aim of numerically investigating and comparing the performance of CFDT columns under cyclic and seismic loads and providing innovative strengthening methods for CFDT columns. Hollow circular steel sections have been used for internal and external tubes. To make the circular CFDT columns stronger against seismic loads, stiffeners with different shapes (rectangular and T-shaped sheets) have been welded to the outside and inside tubes. The validated finite element (FE) model of the ABAQUS program is used to look into the behavior of CFDT columns numerically. Two frames of 10 and 20 floors with strengthened CFDT columns were modeled. The results showed that the use of stiffeners in the CFDT column has a significant effect on seismic performance, so that the maximum lateral load of the column is increased up to 32.74% under the effect of cyclic load. Also, the results revealed that the use of stiffeners in the columns of moderate and high-rise building frames causes a significant increase in the shear of the base and consequently the stiffness. Among the other important results that followed, it reduced the drift of floors and increased energy absorption.

Evaluation of Seismic Performance for an Internally Confined Hollow CFT Column (내부 구속 중공 CFT 기둥의 내진 성능 평가)

  • Han, Taek Hee;Kim, Sung Nam;Kang, Young Jong
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.1
    • /
    • pp.53-65
    • /
    • 2007
  • Column tests were performed for a new type of column, the internally confined hollow concrete filled tube column (ICH CFT column), to evaluate its seismic performance. The seismic performances for two types of ICH CFT columns and a general solid RC column were evaluated and compared by quasi-static tests. The displacements and the lateral loads of column specimens were measured during tests. Ductilities, absorbed energy, equivalent damping ratios, damage indices were calculated from recorded data. From the test results, the ICH CFT column shows superior seismic performances with double moment capacity and larger energy absorbing capacity over that of a solid RC column.

An Improved Bond Slip Model of CFT Columns for Nonlinear Finite Element Analysis (CFT 기둥의 비선형 유한요소해석을 위한 개선된 강관-콘크리트 간 부착 모델 개발)

  • Kwon, Yangsu;Kwak, Hyo-Gyoung;Hwang, Ju-Young;Kim, Jin-Kook;Kim, Jong-Min
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.2
    • /
    • pp.213-220
    • /
    • 2015
  • CFT column has a lot of structural advantages due to the composite behavior between in-filled concrete and steel tube. This paper deals with the development of an effective numerical model which can consider the bond-slip behavior between both components of concrete matrix and steel tube without taking double nodes. Since the applied axial load to in-filled concrete matrix is delivered to steel tube by the confinement effect and the friction, the governing equation related to the slip behavior can be constructed on the basis of the force equilibrium and the compatability conditions. In advance, the force and displacement relations between adjacent two nodes make it possible to express the slip behavior with the concrete nodes only. This model results in significant savings in the numerical modeling of CFT columns to take into account the effect of bond-slip. Finally, correlation studies between numerical results and experimental data are conducted to verifying the efficiency of the introduced numerical model.

Hysteresis Behavior of Semirigid CFT Column-to-Beam Connections with a Double Web-Angle (더블 웨브앵글 반강접 CFT 기둥-보 접합부의 이력거동)

  • Lee, Sung Ju;Kim, Joo Woo
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.1
    • /
    • pp.15-24
    • /
    • 2013
  • This paper presents the results from a systematic finite element study on the bending moment resisting capacity of double web-angle connection for a CFT(concrete filled tube) composite frame subjected to cyclic loading. The three-dimensional nonlinear finite element models are constructed to investigate the rotational stiffness, bending moment capacity, and failure modes of the partially restrained composite CFT connections. A wide scope of additional structural behaviors explain the different influences of the double web-angle connections parameters, such as the different thickness of connection angles and the gage distances of high strength steel connection bar. The moment-rotation angle relationships obtained statically from the finite element analysis are compared with those from Richard's theoretical equation.