• 제목/요약/키워드: concentrically steel braced frames

검색결과 46건 처리시간 0.019초

Seismic behavior of concentrically steel braced frames and their use in strengthening of reinforced concrete frames by external application

  • Unal, Alptug;Kaltakci, Mevlut Yasar
    • Steel and Composite Structures
    • /
    • 제21권4호
    • /
    • pp.687-702
    • /
    • 2016
  • There are many studies in the literature conducted on the subject of ensuring earthquake safety of reinforced concrete and steel structures using steel braced frames, but no detailed study concerning individual behavior of steel braced frames under earthquake loads and strengthening of reinforced concrete structures with out-of-plane steel braced frames has been encountered. In this study, in order to evaluate behaviors of "Concentrically Steel Braced Frames" types defined in TEC-2007 under lateral loads, dimensional analysis of Concentrically Steel Braced Frames designed with different scales and dimensions was conducted, the results were controlled according to TEC-2007, and after conducting static pushover analysis, behavior and load capacity of the Concentrically Steel Braced Frames and hinges sequence of the elements constituting the Concentrically Steel Braced Frames were tested. Concentrically Steel Braced Frames that were tested analytically consist of 2 storey and one bay, and are formed as two groups with the scales 1/2 and 1/3. In the study, Concentrically Steel Braced Frames described in TEC-2007 were designed, which are 7 types in total being non-braced, X-braced, V- braced, $\wedge$- braced, $\backslash$- braced, /- braced and K- braced. Furthermore, in order to verify accuracy of the analytic studies performed, the 1/2 scaled concentrically steel X-braced frame test element made up of box profiles and 1/3 scaled reinforced concrete frame with insufficient earthquake resistance were tested individually under lateral loads, and test results were compared with the results derived from analytic studies and interpreted. Similar results were obtained from both experimental studies and pushover analyses. According to pushover analysis results, load-carrying capacity of 1/3 scaled reinforced concrete frames increased up to 7,01 times as compared to the non-braced specimen upon strengthening. Results acquired from the study revealed that reinforced concrete buildings which have inadequate seismic capacity can be strengthened quickly, easily and economically by this method without evacuating them.

Parametric study on energy demands for steel special concentrically braced frames

  • Dogru, Selcuk;Aksar, Bora;Akbas, Bulent;Shen, Jay
    • Steel and Composite Structures
    • /
    • 제24권2호
    • /
    • pp.265-276
    • /
    • 2017
  • Structures are designed in such a way that they behave in a nonlinear manner when subject to strong ground motions. Energy concepts have been widely used to evaluate the structural performance for the last few decades. Energy based design can be expressed as the balance of energy input and the energy dissipation capacity of the structure. New research is needed for multi degree of freedom systems (MDOFs)-real structures- within the framework of the energy based design methodology. In this paper, energy parameters are evaluated for low-, medium- and high-rise steel special concentrically braced frames (SCBFs) in terms of total energy input and hysteretic energy. Nonlinear dynamic time history analyses are carried out to assess the variation of energy terms along the height of the frames. A seismic energy demand spectrum is developed and hysteretic energy distributions within the frames are presented.

지진하중을 받는 대각선 철골 중심가새골조의 동적 불안정 거동 (Dynamic Instability Behavior of Diagonally Braced Steel Frames under Seismic Excitation)

  • 이철호;김정재
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2005년도 학술발표회 논문집
    • /
    • pp.129-136
    • /
    • 2005
  • Concentrically braced steel frames are considered as being quite prone to soft-story response due to the degradation in brace compressive resistance after buckling under severe ground motions. When combined with the system P-Delta effects, collapse of the concentrically braced frames by dynamic instability becomes a highly probable. In this study, a new, relatively simple dynamic instability coefficient was proposed for diagonally braced steel frames by considering the strength degradation of the brace after buckling. Nonlinear dynamic analysis was conducted to check the robustness of the proposed index based on simulated ground motions. The analysis results showed that the dynamic instability index proposed predicts the collapse potential more consistently than the conventional one. Dynamic instability was triggered when the index value was close to 0.7.

  • PDF

쉬어탭 공유 접합부를 갖는 비내진중심가새골조의 내진거동 (Seismic Behavior of Non-Seismic Concentrically Braced Frames with Shared Shear tab)

  • 염희진;정은비;유정한
    • 한국강구조학회 논문집
    • /
    • 제27권3호
    • /
    • pp.323-332
    • /
    • 2015
  • 특수중심가새골조(Special Concentrically Braced Frames)는 우수한 경제성, 비탄성 변형 능력, 연성 등의 이점 때문에 횡하중 저항 시스템으로써 다양한 구조물에 적용하고 있다. 이러한 이점으로 국내 외 연구진의 특수중심가새골조에 대한 연구가 지속적으로 진행되어 설계법과 기준이 비약적으로 발전한 반면에, 과거에 설계된 중심가새골조의 내진 성능에 대한 연구는 미약하다. 특히, 1988년 이전에 설계된 중심가새골조는 현재 기준과 비교하여 상대적으로 적은 설계요구를 반영하였기 때문에 내진 거동에 대한 평가가 시급한 실정이다. 본 연구에서는 이러한 중심가새골조를 비내진중심가새골조(Non-Seismic Concentrically Braced Frames)라 칭하고, 워싱턴대학교에서 실시된 사례 조사를 토대로 비내진중심가새골조의 대표적인 접합부인 쉬어탭 공유 용접접합부를 갖는 골조의 내진 거동에 대한 유한요소모델을 제시하고 검증하였다. 이 모델을 이용하여 특수중심가새골조와 대비되는 비내진중심가새골조의 연성 능력, 강도, 비탄성 변형 능력에 대해 규명하여 내진 성능을 평가하였다.

Experimental and numerical study of a steel plate-based damper for improving the behavior of concentrically braced frames

  • Denise-Penelope N. Kontoni;Ali Ghamari;Chanachai Thongchom
    • Steel and Composite Structures
    • /
    • 제47권2호
    • /
    • pp.185-201
    • /
    • 2023
  • Despite the high lateral stiffness and strength of the Concentrically Braced Frame (CBF), due to the buckling of its diagonal members, it is not a suitable system in high seismic regions. Among the offered methods to overcome the shortcoming, utilizing a metallic damper is considered as an appropriate idea to enhance the behavior of Concentrically Braced Frames (CBFs). Therefore, in this paper, an innovative steel damper is proposed, which is investigated experimentally and numerically. Moreover, a parametrical study was carried out to evaluate the effect of the mechanism (shear, shear-flexural, and flexural) considering buckling mode (elastic, inelastic, and plastic) on the behavior of the damper. Besides, the necessary formulas based on the parametrical study were presented to predict the behavior of the damper that they showed good agreement with finite element (FE) results. Both experimental and numerical results confirmed that dampers with the shear mechanism in all buckling modes have a better performance than other dampers. Accordingly, the FE results indicated that the shear damper has greater ultimate strength than the flexural damper by 32%, 31%, and 56%, respectively, for plates with elastic, inelastic, and plastic buckling modes. Also, the shear damper has a greater stiffness than the flexural damper by 43%, 26%, and 53%, respectively, for dampers with elastic, inelastic, and plastic buckling modes.

Evaluation of seismic criteria of built-up special concentrically braced frames

  • Izadi, Amin;Aghakouchak, Ali A.
    • Steel and Composite Structures
    • /
    • 제29권1호
    • /
    • pp.23-37
    • /
    • 2018
  • In this paper, seismic provisions related to built-up special concentrically braced frames (BSCBFs) are investigated under cyclic loading using non-linear finite element analysis of a single-bay single-story frame. These braces, which contain double angle and double channel brace sections, are considered in two types of single diagonal and X-braced frames. The results of this study show that current seismic provisions such as observing the 0.4 ratio for slenderness ratio of individual elements between stitch connectors are conservative in BSCBFs, and can be increased according to the type of braces. Furthermore, such increments will lead to decreasing or remaining the current middle protected zone requirements of each BSCBFs. Failure results of BSCBFs, which are related to the plastic equivalent strain growth of members and ductility capacity of the models, show that the behaviors of double channel back-to-back diagonal braces are more desirable than those of similar face-to-face ones. Also, for double angle diagonal braces, results show that the failure of back-to-back BSCBFs occurs faster in comparison with face-to-face similar braces. In X-braced frames, cyclic and failure behaviors of built-up face-to-face models are more desirable than similar back-to-back braces in general.

Progressive collapse analysis of buildings with concentric and eccentric braced frames

  • Larijan, Reza Jalali;Nasserabadi, Heydar Dashti;Aghayan, Iman
    • Structural Engineering and Mechanics
    • /
    • 제61권6호
    • /
    • pp.755-763
    • /
    • 2017
  • In this study, the susceptibility of different symmetric steel buildings with dual frame system to Progressive Collapse (PC) was assessed. Some ten-story dual frame systems with different type of braced frames (concentrically and eccentrically braced frames) were considered. In addition, numbers and locations of braced bays were investigated (two and three braced bays in exterior frames) to quantitatively find out its effect on PC resistance. An Alternate Path Method (APM) with a linear static analysis was carried out based on General Services Administration (GSA 2003) guidelines. Maximum Demand Capacity Ratio (DCR) for the elements (beams and columns) with highest DCRs ($DCR_{moment}$ and $DCR_{shear}$) is given in tables. The results showed that the three braced bays with concentric braced frames especially X-braced and inverted V-braced frame systems had a lower susceptibility and greater resistance to PC. Also, the results represented that the beams were more critical than columns against PC after the removal of column.

역V형 특수중심가새골조의 최적내진설계 모델 개발 (Development of Optimal Seismic Design Model for Inverted V-type Special Concentrically Braced Frames)

  • 최세운;양회진;박효선
    • 한국전산구조공학회논문집
    • /
    • 제23권1호
    • /
    • pp.111-119
    • /
    • 2010
  • 여러 연구자들에 의해 최적화 알고리즘을 이용한 최적내진설계에 관한 연구가 컴퓨터의 발달과 더불어 활발히 이루어져 왔다. 하지만 지금까지의 최적내진설계에 관한 연구는 대부분 모멘트저항골조를 대상구조물로 한 연구였다. 가새골조는 모멘트저항골조와 더불어 대표적인 횡력저항시스템이기 때문에 가새골조의 최적내진설계기법 개발을 통해 경제적이며 효율적인 설계가이드라인을 제시할 수 있다면 실무에 미치는 파급효과는 클 것이라 판단된다. 본 논문에서는 가새의 좌굴을 고려한 역V형 특수중심가새골조의 최적내진설계 알고리즘을 제안하고자 한다. 제안된 알고리즘은 구조물의 물량과 에너지 소산량을 목적함수로 설정하고, 강도조건 및 층간변위 조건등의 제약조건으로 설정한다. 알고리즘의 검증을 위해 2D 3층, 9층 역V형 특수중심가새골조 예제를 적용한다.

대각선 철골 중심가새골조의 지질동하에서의 동적불안정 거동 (Dynamic Instability of Diagonally Braced Steel Frames under Seismic Excitation)

  • 김정재;이철호
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2004년도 가을 학술발표회 논문집
    • /
    • pp.288-295
    • /
    • 2004
  • Concentrically braced steel frames are considered as being quite pone to soft-story response due to the degradation in brace compressive resistance after buckling under severe ground motions. When combined with the system P-Delta effects, collapse of the concentrically brsced frames by dynamic instability becomes highly probable. In this stidy, a new, relatively simple dynamic instability coefficient was proposed for diagonally braced steel flames by explicitly considering the strength degradation of the brace after buckling. Nonlinear dynamic analysis results showed that the dynamic instability coefficient proposed in this study predicted collapse limit state more consistently than the conventional one which ignores the strength degradation of the brace.

  • PDF

플랜트 설비 지지용 대안 강구조 시스템의 내진성능 (Seismic Performance of Alternative Steel Structural Systems for an Equipment-Supporting Plant Structure)

  • 곽병훈;안숙진;박지훈
    • 한국지진공학회논문집
    • /
    • 제27권1호
    • /
    • pp.13-24
    • /
    • 2023
  • In this study, alternative seismic force-resisting systems for plant structure supporting equipment were designed, and the seismic performance thereof was compared using nonlinear dynamic analysis. One alternative seismic force-resisting system was designed per the requirement for ordinary moment-resisting and concentrically braced frames but with a reduced base shear. The other seismic force-resisting system was designed by accommodating seismic details of intermediate and unique moment-resisting frames and special concentrically braced frames. Different plastic hinge models were applied to ordinary and ductile systems based on the validation using existing test results. The control model obtained by code-based flexible design and/or reduction of base shear did not satisfy the seismic performance objectives, but the alternative structural system did by strengthened panel zones and a reduced effective buckling length. The seismic force to equipment calculated from the nonlinear dynamic analysis was significantly lower than the equivalent static force of KDS 41 17 00. The comparison of design alternatives showed that the seismic performance required for a plant structure could be secured economically by using performance-based design and alternative seismic-force resisting systems adopting minimally modified seismic details.