  • The Sn $O_2$-based gas sensors can detect inflammable and toxic gases of low concentration by the modulation of surface resistance, but they lack in selectivity on the whole. To give selectivity to the Sn $O_2$-based gas sensors, studies on the sensing mechanism, selective gas sensing materials and signal processing techniques are demanded. Ethanol (C$_2$ $H_{5}$OH) and acetonitrile ($CH_3$CN) were confirmed to undergo catalytic oxidation on Sn $O_2$ by gas chromatography. PdCl$_2$-doped Sn $O_2$ showed excellent sensitivity to ethanol and acetonitrile, while La$_2$ $O_3$-doped Sn $O_2$ showed excellent sensitivity to ethanol, but poor sensitivity to acetonitrile. Using these two sensors and pattern recognition, the selectivity to acetonitrile is greatly enhanced. The minimum detection level of acetonitrile was 15 ppm in air and 20 to 100 ppm when exposed to interfering gases together with acetonitrile.

Toxicity Evaluation of Effluent Gases from a Residental Fire by Rats (연립 주택 화재시 유독가스 방출 특성과 Rats를 이용한 독성평가)

  • Kim, Hong;Kang, Young-Goo;Kim, Dong-Hyun;Jung, Ki-Chang;Lee, Chang-Seop;Kim, Woon-Hyung
    • Fire Science and Engineering
    • /
    • v.16 no.3
    • /
    • pp.12-15
    • /
    • 2002
  • It has long been recognized that exposure to fire-induced toxic gases is a fatal hazard confront-ing people in fires. In this study, an indoor fire experiment was conducted in an unoccupied residential building located in An-san city, Kyoung-gi province, and the composition of effluent gases, which include CO, $CO_2$, $O_2$, $SO_2$, NO and $NO_2$, were measured by a gas analyzer. A group of lab rats were exposed to the toxic gases released from fire, and the blood samples of the rats were gathered every 2 minutes. A toxicity evaluation was conducted by analyzing the concentrations of Glucose, AST(GOT), ALT(GPT), CBC Count and CO(carboxy)-Hb in the blood samples. Shown from the analysis is the does-response relationship between the CO concentration that rats were exposed to and the CO-Hb concentration in rat blood.

Fire Patterns According to the Blood Hb-CO Concentration of Charred Bodies (소사체의 혈중 헤모글로빈-일산화탄소 농도에 따른 연소형태 연구)

  • Choi, Seung-Bok;Oh, Bu-Yeol;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.40-48
    • /
    • 2012
  • Fire patterns have been used to determine the origin and cause of fires in every setting imaginable. However, it is very difficult to identify fire patterns and causes from the fire-damaged remains of a devastated structure. If someone was killed by the fire, it is possible to identify fire patterns by analyzing the Hb-CO concentration in charred bodies of deceased as well as the pace of the fire. For example, a low level of Hb-CO concentration in the charred bodies indicate a rapid fire with accelerants and the death was caused by severe heat and thick toxic fumes. However, a high level of Hb-CO concentration in the charred bodies demonstrates that the fire was slow and/or there was a flameless form of combustion. Thus, it is possible to identify fire patterns through analyzing the level of Hb-CO concentration on the dead from the fire. In this study, the Hb-CO concentration in the charred bodies was from 3 % at the case of gas burning oneself to death to 93 % at the death caused by smoldering fire.

Determination of Volatile Organic Compounds (VOCs) Using Tedlar Bag/Solid-phase Microextraction/Gas Chromatography/Mass Spectrometry (SPME/GC/MS) in Ambient and Workplace Air

  • Lee, Jae-Hwan;Hwang, Seung-Man;Lee, Dai-Woon;Heo, Gwi-Suk
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.3
    • /
    • pp.488-496
    • /
    • 2002
  • SPME techniques have proven to be very useful tools in the analysis of wide VOCs in the air. In this study, we estimated VOCs in ambient and workplace air using a Tedlar ba /SPME/GC/MS system. The calibration curve was set to be linear over the range of 1-30 ppbv. The detection limits ranged from 10 pptv to 0.93 ppbv for all VOCs. Reproducibility of TO-14 target gas mixtures by SPME/GC/MS averaged at 8.8 R.S.D (%). Air toxic VOCs (hazardous air pollutants, HAPs) containing a total of forty halohydrocarbons, aromatics, and haloaro-matic carbons could be analyzed with significant accuracy, detection limit and linearity at low ppbv level. Only reactive VOCs with low molecular weight, such as chloromethane, vinylchloride, ethylchloride and 1,2-dichloro-ethane, yielded relatively poor results using this technique. In ambient air samples, ten VOCs were identified and quantified after external calibration. VOC concentration in ambient and workplace air ranged from 0.04 to 1.85 ppbv. The overall process was successfully applied to identify and quantify VOCs in ambient/workplace air.

Removal of sulfur element from high-sulfur coal by superconducting HGMS technology

  • Han, Shuai-shuai;Li, Su-qin;Yang, Rui-ming;Yang, Chang-qiao;Xing, Yi
    • Progress in Superconductivity and Cryogenics
    • /
    • v.21 no.2
    • /
    • pp.26-30
    • /
    • 2019
  • Coal is the most abundant fossil fuel on Earth and is used in a wide range of applications. The direct combustion of high-sulfur coal produces a large amount of sulfur dioxide, which is a toxic and corrosive gas. A new superconducting high gradient magnetic separation (HGMS) technology was studied to remove sulfur from high sulfur coal. The magnetic separation concentrate was obtained under the optimum parameters, such as a particle size of -200 mesh, a magnetic field strength of 2.0 T, a slurry concentration of 15 g/L, and a slurry flow rate of 600 ml/min. The removal rate of sulfur is up to 59.9%. The method uses a magnetic field to remove sulfur-containing magnetic material from a pulverized coal solution. It is simple process with, high efficiency, and is a new way.

Operation Characteristics of an UASB at High Organic Loading Condition for Thermal Elutriated Acids of Piggery Wastewater Treatment (가축분뇨 고온 세정산발효액 처리를 위한 고부하 조건에서의 UASB 운전특성)

  • Kwon, Koo-Ho;Jung, Yong Jun;Min, Kyung-Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.6
    • /
    • pp.781-785
    • /
    • 2012
  • This study was carried out to treat the thermal elutriated acids of piggery wastewater using UASB process. The UASB reactor was operated at an organic loading rate (OLR) of $7.4\;kgCOD/m^3-day$ (6.5 ~ 9.0). During the start-up period, the low COD removal efficiency (20%) was caused by shock loading and instability in the reactor. It was mainly due to the high concentration amounts of ammonia nitrogen, which caused inhibitory and toxic effects to toward the anaerobic bacteria. In steady state, the UASB reactor showed a SCOD removal efficiency of 71% and a VS removal efficiency of 39%. The gas production and methane content were 1.3 L/day $(0.21\;m^3\;CH^4/kg$ COD removed) and 77%, respectively.

Investigation of toxic organic solvent exposure in work places (작업장에서의 유해 유기용제 폭로에 관한 연구)

  • Jo, Young Min;Kang, Sang Wan;Oh, Jong Min
    • Journal of Environmental Impact Assessment
    • /
    • v.9 no.1
    • /
    • pp.75-86
    • /
    • 2000
  • The purpose of this work was to document the conditions regarding organic solvent exposure to the workers in paint industry. Air concentrations of organic solvents were measured by passive personal samplers and analyzed by a gas chromatography. Urine samples for hippuric test were also taken from 330 workers who have worked at seven domestic factories for more than two years. Amongst 25 organic elements detected in the indoor environment of working places, toluene was the most common element, and methanol showed the highest mean concentration(18.2ppm). A few elements including methylethyl ketone and toluene partially exceeded the Korean Permissible Exposure Limit. A lack of environmental facilities such as exhaust ventilation, automatic cleaning system, and personal safety devices at present work plaus brings about various occupational diseases.

  • PDF

Bioactivity of Cajuput Seedling n-Hexane Extract as an Attractant for Subterranean Termite Coptotermes curvignathus Holmgren (Isoptera: Rhinotermitidae)

  • Arinana ARINANA;Rama Aditya DHARMA;Rita Kartika SARI;Anindya Intan RAHMAWATI;Riki ANDIKA;Dodi NANDIKA
    • Journal of the Korean Wood Science and Technology
    • /
    • v.52 no.1
    • /
    • pp.31-46
    • /
    • 2024
  • Subterranean termite attacks on cajuput (Melaleuca cajuputi) seedling roots were widespread in several of Java's Perum Perhutani Forest Management Units. This attack was suspected to be related to the chemical components of the cajunput seedling roots. This study was conducted to determine the bioactivity of cajuput seedling root extract as an attractant for the subterranean termite Coptotermes curvignathus Holmgren (Isoptera: Rhinotermitidae). The extraction process was performed according to ASTM D1108-96, and the extract was characterized using gas chromatography-mass spectrometry (GC-MS). Bioactivity testing of the extracts was carried out using attractiveness and no-choice feeding bioassays. The results showed that the average root extraction yield from cajunput seedlings was 4.94%. The attractiveness of the extract solutions at concentrations of 0.50%, 0.75%, and 1.00% were 45.33%, 62.00%, and 74.67%, respectively. The mortality rate of C. curvignathus termites ranged from 9.63% to 24.44%. Cajuput seedling root extract's lethal concentration 50 was 2.45% (non-toxic). GC-MS analysis showed that the extract contained linoleic acid, which has the potential to attract insects.

Analysis of fire hazard of karaoke utilizing the fire simulation (화재시뮬레이션을 활용한 노래방 화재 위험성 분석)

  • Kim, Tae Kwon;Park, Jong Choel
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.2533-2538
    • /
    • 2014
  • In this study, 2-zone model CFAST software was used to predict the fire hazard of karaoke. Model is a three-dimensional unsteady state. Accuracy of CFAST is verified by comparing result of CFAST analysis with result of real fire experiment. For analysis results, the oxygen concentration were reduced to 10% within 5 minutes in room 5, the carbon dioxide concentration were increased to 5%. Therefore, at the enclosed space like karaoke, we can predict that dangerous situation would occur and people be suffocated because of toxic gas.

An Experimental Study on Smoke Movement by the External Wind in Road Tunnel Fires (도로터널 화재 시 외부 바람에 의한 연기거동 특성에 관한 실험적 연구)

  • Lee, Sung-Ryong
    • Tunnel and Underground Space
    • /
    • v.24 no.4
    • /
    • pp.308-315
    • /
    • 2014
  • In this study, reduced scale experiments were carried out to evaluate the effect of external wind in a road tunnel fire. Experiments were conducted in a $1.1m{\times}0.5m{\times}50.4m$ tunnel. 4.5 litter gasoline was used as a fuel. Temperature, oxygen and carbon monoxide concentration were measured. Smoke reaching time to the tunnel exit was affected by the external wind. When a fire was fully developed, wind effect is reduced compared with the early stage of a fire. CO concentration was reached at more than 1,500 ppm.