• Title/Summary/Keyword: concentration of information

Search Result 2,742, Processing Time 0.03 seconds

An Assesesment of Leaf Chlorophyll Concentration of Afforestation Tree Species in South-Eastern, Nigeria

  • Udeagha, Agbaeze Umazi;Shomkegh, Simon Alyegba;Daniel, Koko Sunday
    • Journal of Forest and Environmental Science
    • /
    • v.32 no.2
    • /
    • pp.205-211
    • /
    • 2016
  • Leaf chlorophyll content provides valuable information about physiological status of plants. However, fewer studies have investigated the difference in chlorophyll concentration in leaves of tropical afforestation tree species. Therefore, this study examines the difference in foliar chlorophyll contents of six tropical afforestation tree species namely: Tectona grandis, Pentaclethra macrophylla, Piptademiastrum africanum, Azadirachta indica, Brachystegia eurycoma and Gmelina arborea found in the relict forest in Umudike, South east, Nigeria. A single factor experiment in a completely randomised design in three replicates was employed to analyse the rate of leaf chlorophyll contents. Fisher's least significant different was used to test for significance in mean difference in foliar chlorophyll contents between tree species at 95% confidence interval using analysis of variance. The results of this study showed a significant difference in foliar chlorophyll concentration between the tree species with Tectona grandis having a higher chlorophyll concentration than other trees this could be as a result of its higher vegetative activity which increases its primary productivity followed by Pentaclethra macrophylla while Azadirachta indica having least the chlorophyll concentration. The study further revealed that other indigenous tree species like Piptademiastrum africanum and Brachystegia eurycoma have higher chlorophyll concentration. Further studies should be carry out to examine factors that have contributed informed the differences in the chlorophyll concentration of these trees species, thus this would broaden the understanding of their physiological status and equally encourage there conservation.

Estimation of Nitrate Nitrogen Concentration in Liquid Fertilizer Contaminated Areas using Hyperspectral Images (초분광 영상을 이용한 액비 오염지역의 질산성질소 농도 추정)

  • Lim, Eun Sung;Kim, I Seul;Han, Soo Jeong;Lim, Tai Yang;Song, Wonkyong
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.3
    • /
    • pp.542-549
    • /
    • 2020
  • Purpose: As nitrate nitrogen produced during fermentation of liquid fertilizer is a pollution indicator of water, in this study, four research areas where liquid fertilizer was sprayed were selected, and a model was designed to estimate the concentration of nitrate nitrogen pollution. Method: Prior to shooting on site, a spectrum library was constructed by dividing the ratio of liquid fertilizer into 5 groups: 0%, 25%, 50%, 75%, and 100%. PLSR (Partial least squares regression) method was applied to hyperspectral images acquired in the study area based on the aspect of spectrum. Result: The behavior of nitrate nitrogen was confirmed by 1st and 2nd differentiation of the spectrum of the constructed liquid fertilizer. PLSR concentration estimation modeling was implemented using images from field experiments and compared with actual concentration of nitrate nitrogen. Conclusion: When comparing the PLSR concentration estimation model with the actual concentration of nitrate nitrogen, it was measured that the detection is possible in high concentration areas where the concentration of nitrate nitrogen is 70mg/kg or more.

Current status of fluoride concentration and information labeling of oral hygiene products on the Korean market (국내시판 불소함유 구강위생용품의 실태조사)

  • Oh, Chi-Un;Kim, Kyung-Hee
    • Journal of Korean society of Dental Hygiene
    • /
    • v.22 no.4
    • /
    • pp.231-240
    • /
    • 2022
  • Objectives: This study was conducted to survey the currently available fluoride-containing oral hygiene products in Korea to provide consumers with information regarding the concentration and form of fluoride in each product, as well as to determine whether the information was easy to understand. Methods: A total of 64 types of domestic commercial oral hygiene products were purchased from an offline market and evaluated. Results: The domestic commercial toothpaste products contained fluoride in the form of sodium fluoride (NaF) and sodium monofluorophosphate (SMFP). In this study, toothpaste containing 1,000 ppm fluoride compounds accounted for the largest proportion (61.5%). Toothpastes containing below 1,000 ppm fluoride accounted for 34.6%, while toothpastes with fluoride above 1,000 ppm fluoride accounted for 3.9%. Toothpaste containing more than 1,000 ppm fluoride has not been popularized domestically. Mouthwash products contained fluoride compounds at less than 300 ppm concentration. Of the five types of mouthwash products, only two types had labels indicating fluoride concentration. In addition, the location of the labels indicating fluoride concentration differed between manufacturers and even within the same manufacturer. Conclusions: It is important to popularize toothpaste with fluoride levels above 1,000 ppm so that a broader selection of toothpaste can be offered to consumers in need. Standardized information needs to be provided for consumer convenience to aid in choosing appropriate oral hygiene products.

KOH Hydrothermal Synthesis of Zeolites from Hadong Kaolin (KOH수열 처리에 의한 하동카오린으로부터 Zeolite의 합성)

  • 이무강;신현무;임경천
    • Journal of Environmental Science International
    • /
    • v.12 no.12
    • /
    • pp.1321-1327
    • /
    • 2003
  • Two different kinds of cases, with and without addition of noncrystalline silica to the Hadong kaolin were studied to obtain useful information on the synthesis of zeolite. The research was carried out to investigate the formation area and the crystalized degree of zeolite according to a synthetic time, the water content of raw material mixture, KOH concentration, and stirring intensity. In the case of without addition of noncrystalline silica to the Hadong kaolin and the low concentration range of KOH, the structure of the kaolin was not changed. However, when the mole ratio of K2O/SiO$_2$ in natural kaolin was increased, Linde-L zeolite and unknown structure of kaolins, U-1 and U-2 were produced. While in the high concentration range of KOH, the unknown structure of kaolins, U-6 and U-2, were produced and the production rate of U-6 was increased with the increased of K2O/SiO$_2$ mole ratio. In the case of with addition of noncrystalline silica to the Hadong kaolin and treatment with KOH hydrothermal processing, ZSM-5, ZSM-35, and Linde-L zeolites and the mixture of unknown structure of zeolites, U-1, U-2, U-3, and U-4, were obtained. Both cases demonstrated that the synthesis of zeolite from the Hadong kaolin was highly influenced by KOH concentration of raw material mixture.

EFFECTS OF ATMOSPHERIC WATER AND SURFACE WIND ON PASSIVE MICROWAVE RETRIEVALS OF SEA ICE CONCENTRATION: A SIMULATION STUDY

  • Shin, Dong-Bin;Chiu, Long S.;Clemente-Colon, Pablo
    • Proceedings of the KSRS Conference
    • /
    • v.2
    • /
    • pp.892-895
    • /
    • 2006
  • The atmospheric effects on the retrieval of sea ice concentration from passive microwave sensors are examined using simulated data typical for the Arctic summer. The simulation includes atmospheric contributions of cloud liquid water and water vapor and surface wind on surface emissivity on the microwave signatures. A plane parallel radiative transfer model is used to compute brightness temperatures at SSM/I frequencies over surfaces that contain open water, first-year (FY) ice and multi-year (MY) ice and their combinations. Synthetic retrievals in this study use the NASA Team (NT) algorithm for the estimation of sea ice concentrations. This study shows that if the satellite sensor’s field of view is filled with only FY ice the retrieval is not much affected by the atmospheric conditions due to the high contrast between emission signals from FY ice surface and the signals from the atmosphere. Pure MY ice concentration is generally underestimated due to the low MY ice surface emissivity that results in the enhancement of emission signals from the atmospheric parameters. Simulation results in marginal ice areas also show that the atmospheric and surface effects tend to degrade the accuracy at low sea ice concentration. FY ice concentration is overestimated and MY ice concentration is underestimated in the presence of atmospheric water and surface wind at low ice concentration. In particular, our results suggest that strong surface wind is more important than atmospheric water in contributing to the retrieval errors of total ice concentrations over marginal ice zones.

  • PDF

Changes in the Contents of Phenolic Components in the Stem of Acanthopanax koreanum Depending on Extracting Batches (섬오가피의 추출 조건에 따른 페놀성 성분 함량 변화)

  • Kim, Sung Gi;Lee, Jae Bum;Cho, Soon Hyun;Ko, Sung Kwon
    • Korean Journal of Pharmacognosy
    • /
    • v.50 no.2
    • /
    • pp.124-132
    • /
    • 2019
  • This study compared the contents of phenolic components depending on the extracting conditions of Acanthopanax koreanum stem to provide basic information for developing Acanthopanax koreanum-based functional foods. Our findings show that the content of total phenolic component peaked at 16 hours of extraction (WAK-16, 7.22%) and when water extracted at $100^{\circ}C$. However, 11-hours water extraction (WAK-11) showed highest eleutheroside B concentration of 1.32%, a main component of A. koreanum, and the level of chlorogenic acid concentration was the highest when 1-hour water extraction (WAK-1) was conducted, being 2.12%. Moreover, highest concentration of eleutheroside E was observed in 16-hours water extraction (WAK-16) as 1.49%. With 60-hours water extraction (WAK-60), the content of syringaresinol, an active phenolic aglycon substance, concentration was the highest with the value of 0.10%. Isofraxidin showed the highest concentration of water extract(0.09%) for 20 hours (WAK-20) and 0.42% for sinapyl alcohol[16 hours (WAK-16)].

The Influence of Water Temperature and Food Concentration on the Filtration Rates of the Asiatic Clam, Corbicula fluminea (수온과 먹이생물의 농도 변화에 따른 재첩의 여과율 변동)

  • Lim, Kyeong-Hun;Shin, Hyun-Chool;Yang, Jae-Sam
    • The Korean Journal of Malacology
    • /
    • v.21 no.1
    • /
    • pp.19-24
    • /
    • 2005
  • This study was undertaken with the intent to describe the influence of water temperature and food concentration on the filtration rates of the Asiatic clam, Corbicula fluminea. The clams were collected at Lake Geumho near Yeongsan river, during March 2001. Food organism, Scenedesmus sp. (KMCC FC-34), was indoor-cultured in f/2 medium, and was used to measure the filtration rate of the clams. Filtration rate of the clams was measured by indirect method. Cell concentrations of food organisms were determined by direct counting cells using the hemacytometer under the light microscope. The filtration rate of the clams increased with water temperature up to circa $25^{\circ}C$. Above this temperature, the filtration rate decreased rapidly. The minimal filtration rate of the clams was recorded at $5^{\circ}C$. Thermal coefficient, $Q_10$ values at low temperature range were much higher than those at high temperature range. These results indicate the asiatic clam is more sensitive in cold water like most of marine bivalves. There was a strong reversed correlation between filtration rate and food concentration. Filtration rate of the clams was reduced as food concentration was increased.

  • PDF

Measurement of Structural Stress Concentration by PVDF Film Sensors (압전필름센서에 의한 구조물의 응력집중의 측정)

  • Kwon, Il-Bum;Kim, Chi-Yeop;Choi, Man-Yong;Lim, Jong-Mook;Kim, In-Gul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.4 no.4
    • /
    • pp.109-119
    • /
    • 2000
  • PVDF film sensor was applied to measure the stress concentration for monitoring the structural integrity. The strain calibration of this film sensor was performed by the bending test of aluminum beam. The PVDF sensor and the electrical strain gage were bonded on the beam. When the beam was loaded, the output of electrical strain gage was compared with the output of the PVDF sensor. The waveform of PVDF sensor output was shown as the same form of the output of electrical strain gage. The gain was determined as 1.7 by comparing these two signals to determine the exact value of the strain. In order to experiment the stress concentration, the stress field was analyzed by finite element analysis. The tensile test of notched steel specimens was conducted to develop the measurement technique of stress concentration. The output voltage ratio between the PVDF sensor near the notch and the PVDF sensor far from the notch could give the information about the load bearing capacity of steel specimen.

  • PDF

The Effect of Turbidity and Alkalinity on the Regidual Aluminum Concentration (탁도(濁度) 및 알카리도(度)가 잔류(殘留)알루미늄 농도(濃度)에 미치는 영향(影響))

  • Choi, Suingil;Lee, Changsook
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.9 no.3
    • /
    • pp.88-98
    • /
    • 1995
  • Several kinds of coagulants such as aluminum sulfate, PAC, PASS are being used to treat drinking water resulting in residual aluminum ions in the water. Recently, it has been reported that high intake of aluminum ion may cause neurological dieseases such as Alzheimer's diesease and presenile dementia. Because of the possible adverse effect, WHO and EEC recommand to regulate residual aluminum. The autorities in Korea also has plan of regulating residual alunimum from 1995. But there is not enough information about the range of residual aluminum ion concentration when the aluminum sulfate, PAC or PASS has been used as a coagulant. Therefore the study has been conducted to find out the range of residual aluminum ion concentration after using aluminum sulfate, PAC, and PASS. Furthermore the effect of turbidity and alkalinity have been investigated. The experimental results are summarized as; 1. Most of the residual aluminum ion concentrations were within $10^{-6}$ and $10^{-5}mole/l$. Three coagulants have not showed any considerable difference in the residual aluminum concentration up to 50 NTU. However PAC has showed the least residual aluminum in high turbidity water over 100 NTU. 2. The low alkalinity water having 25mg/l as $CaCO_3$ has showed less residual aluminum than the water having 50mg/l alkalinity. However, the difference was not significcant. 3. Even the lowest residual aluminum concentration was over 0.05mg/l. Therefore the process to reduce residual aluminum would be necessary in water treatment plants.

  • PDF

Electronic Properties of Polymer LB Films for the Metal Ion Concentration (금속이온 농도에 의한 고분자 LB막의 전자 특성)

  • 박재철;정상범;유승엽
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.37 no.2
    • /
    • pp.1-5
    • /
    • 2000
  • We have investigated dielectric properties of IMI-O LB films for the effect of complex concentration by electrical conductivity, dielectric constant and dielectric relaxation time at different frequencies. In the surface pressure-area$\pi$-A) isotherms for the increase of $FE^{3+}$ concentration, the molecular area was expanded with $FE^{3+}$concentration increase by electrostatic repulsion between the polymer chains and hydrophobic increase of ionic strength. In the I-V characteristics, it is found that the limiting area has effects on the change of conductivity And, the dielectric relaxation time decreased for increase of the $FE^{3+}$concentration.

  • PDF