• Title/Summary/Keyword: concentration measure

Search Result 1,484, Processing Time 0.023 seconds

Smartphone-based O2 Deficiency Monitoring Device (스마트폰 기반 산소 결핍 모니터링 장치)

  • Loh, Byoung Gook
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.6
    • /
    • pp.117-121
    • /
    • 2015
  • $O_2$-deficiency related accidents occur every year and the most effective way to prevent them is to measure $O_2$ concentration in air with a properly-calibrated $O_2$ monitoring device before entering low-$O_2$ areas. An electro-chemical sensor, Texas Instrument gas platform, and iPhone are used to construct a smartphone-based $O_2$ monitoring device. The smartphone based $O_2$ measuring approach offers advantages of small size, accessibility, internet-connectivity, and programmability in comparison to conventional $O_2$ measuring devices. Multiple gas sensors can be conveniently interfaced to single smartphone, allowing for creating a network of gas sensors distributed across workplaces and remote monitoring via existing mobile communication network. To check proper function of the $O_2$ monitoring device the sensor was exposed to shallow and deep human breaths. The readings decreased immediately after being exposed to exhalation and recovered during inhalation to a calibrated level of 20.9%. When readings decreased below a preset warning value of 19.5%, a low $O_2$ warning was successfully activated on the smartphone.

Mineralization-inducing potentials of calcium silicate-based pulp capping materials in human dental pulp cells

  • Kang, Sohee
    • Journal of Yeungnam Medical Science
    • /
    • v.37 no.3
    • /
    • pp.217-225
    • /
    • 2020
  • Background: This study was performed to provide a long-term bacterial seal through the formation of reparative dentin bridge, calcium silicate-based pulp capping materials have been used at sites of pulpal exposure. The aim of this study was to evaluate the mineralization-inducing potentials of calcium silicate-based pulp capping materials (ProRoot MTA [PR], Biodentine [BD], and TheraCal LC [TC]) in human dental pulp cells (HDPCs). Methods: Specimens of test materials were placed in deionized water for various incubation times to measure the pH variation and the concentration of calcium released. The morphology of HDPCs cultured on the specimens was examined using a confocal laser scanning microscope (CLSM). Alizarin red S staining and alkaline phosphatase assays were used to evaluate mineralization-inducing potentials of the capping materials. Results: BD showed the highest calcium release in all test periods, followed by PR and TC. (p<0.05). All experimental groups showed high alkalinity after 1 day, except at 14 days. BD showed the highest cell viability compared with PR and TC after 1 and 3 days, while TC showed the lowest value (p<0.05). The CLSM analysis showed that cells were well adhered and expressed actin filaments for all pulp capping materials. Mineralization by PR and BD groups was higher than that by TC group based on alizarin red S staining. BD showed significantly higher alkaline phosphatase activity than PR and TC, while TC showed the lowest value (p<0.05). Conclusion: Within the limitations of the in vitro study, BD had higher mineralization-inducing potential than PR and TC.

Effects of Spray Characteristics of Water Mist on The Extinction of a Liquid Pool Fire (분무수 분무특성이 액체연료 Pool 화염의 소화에 미치는 영향)

  • Kim, Ho-Young;Oh, Sang-Youp;Chung, Jin-Taek
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.12
    • /
    • pp.1591-1599
    • /
    • 2004
  • A series of experiments were conducted to study the effectiveness of the extinction of a liquid pool fire with two different water atomizing nozzles. Fire source is a small-scale circular stainless steel pan of 120mm in diameter with the fuels of hexane and ethanol. K-type thermocouples were used to measure the flame and fuel temperature along the pool centerline and under fuel surface. A digital camera was used to visualize the process of the fire suppression. The experimental results show that water mist droplet size is l15∼180${\mu}{\textrm}{m}$ with nozzle A and 130∼190${\mu}{\textrm}{m}$ with nozzle B. The extinguishing time of pool fire was reduced with the increase of pressure. When water droplets are small, they do not reach the flame base since they may be deflected or evaporated by the fire plume. However, influence of flow rate is more important than droplet size on fire extinction. Among the fire extinction mechanisms, drop of flame temperature is superior to suffocation of $O_2$ concentration.

The Experimental Study on the Effect of Fel Ursi & Bovis Calculus Pharmacopuncture Solution in Bacterial Species which cause Keratitis (웅담·우황약침액이 다종의 각막염 유발균에 미치는 영향)

  • Han, Na-Young;Seo, Hyung-Sik
    • Journal of Pharmacopuncture
    • /
    • v.13 no.2
    • /
    • pp.101-110
    • /
    • 2010
  • Objectives : This experimental study was performed to investigate the effect of Fel Ursi & Bovis Calculus pharmacopuncture solution(FUBCPS) manufactured by using alcohol/water extraction method for identify ing the use of it as eyedrops. Methods: FUBCPS was manufactured by using alcohol/water extraction method. Measure the size of inhibition zone and MIC(Minimum Inhibition Concentration) after administering FUBCPS on bacterial species. Staphylococcus aureus. Staphylococcus epidermidis, Pseudomonas aeruginosa, Aspergillus niger, Fusarium oxysporum and Candida albicans, which cause keratitis. Administering cravit(Levonoxacin medicine) on bacterial species also performed to compare the anti-bacterial potency of this material, measured by using the size of inhibition zone Results : After administering FUBCPS on bacterial species(Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa, Aspergillus niger, Fusarium oxysporum, Candida albicans). there was no response to MIC and there was no anti -bacterial potency also. Conclusions : This study suggests that FUBCPS dose not have anti-bacterial effects on bacterial species which cause Keratitis. These study result recommends that we need to research more on herbal medicines of eye drop which have anti-bacterial effects on keratitis

The Effects of Spray Characteristics of Water Mist on the Fire Suppression of Liquid Pool Fire (미분무수 분무특성이 액체연료 Pool 화염의 소화에 미치는 영향)

  • Oh, Sang-Youp;Kim, Ho-Young;Chung, Jin-Taek
    • 한국연소학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.215-221
    • /
    • 2003
  • A series of experiments were conducted to study the effectiveness of the extinction of a liquid pool fire with two different water atomizing nozzles. Fire source is small-scale circular stainless steel pan of 120mm in diameter with the fuels of hexane and ethanol. K-type thermocouples were used to measure the flame and fuel temperature along the pool centerline and under fuel surface. A digital camera was used to visualize the process of the fire suppression. The experimental results show that water mist droplet size is $115{\sim}180{\mu}m$ with nozzle A and $130{\sim}190{\mu}m$ with nozzle B. The extinguishing time of pool fire was reduced with the increase of pressure. When water droplets are small, they do not reach the flame base since they may be deflected or evaporated by the fire plume. However, influence of flow rate is more important than droplet size on fire extinction. Among the fire extinction mechanisms, drop of flame temperature is superior to suffocation of O2 concentration.

  • PDF

A Study on the Detergency and Functionality of Laminating Finished Fabrics for Outdoor Wear by Repeated Washing (아웃도어용 라미네이팅 가공 직물의 반복세척에 의한 세척성 및 기능성 연구)

  • Hyun, Su Jung;Lee, Jeong Sook
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.41 no.3
    • /
    • pp.527-536
    • /
    • 2017
  • This study investigated the detergency and functionality of laminating finished fabrics for outdoor wear based on repeated washing. Laminating finished fabrics were selected as the main fabrics for outdoor wear and used as test fabrics. The effects of outdoor exclusive detergent and normal neutral detergent were examined according to washing time, temperature, rpm and detergent concentration based on the use of a Terg-O-Tometer. Re-soiling of the test fabrics was measured by Florio-Mersereau. Permeability, water repellency, water resistance and absorbency were estimated to measure improvements and effects in regards to outdoor exclusive detergent in optimal washing conditions. The detergent effect of outdoor exclusive detergent was superior compared to normal neutral detergent. Re-soiling was lower with exclusive outdoor detergent than with normal neutral detergent. The measurement of functionality for laminating finished fabrics before and after washing indicated that functionality was decreased with repeated washing.

OXYGEN CONCENTRATION IN THE CATHODE CHANNEL OF PEM FUEL CELL USING GAS CHROMATOGRAPH

  • Ha, T.H.;Kim, H.S.;Min, K.D.
    • International Journal of Automotive Technology
    • /
    • v.8 no.1
    • /
    • pp.119-126
    • /
    • 2007
  • Because of the low temperature operation, proton exchange membrane (PEM) fuel cell has a water phase transition. Therefore, water management is an important operation issue in a PEM fuel cell because the liquid water in the fuel cell causes electrode flooding that can lower the cell performance under high current density conditions. In this study, in order to understand the reactant distributions in the cathode channels of the PEM fuel cell, an experimental technique that can measure the species concentrations of reactant gases by using gas chromatograph (GC) is applied for an operating PEM fuel cell. The oxygen distribution along the cathode flow channels of PEM fuel cell is mainly investigated with various operating conditions. Also, the relations between cathode flooding and oxygen concentrations and oxygen consumption pattern along the cathode channel configurations of the unit cell adopted for this study are discussed using GC measurement and visualization experiment of cathode flooding. It is found that the amount of oxygen consumption is very sensitive to various operating conditions of the fuel cell and was much affected by the flooding occurrence in cathode channels.

Effects of Electrode Shape on Electrode Life of Resistance Spot Welding of Mg Alloy (Mg 합금 저항 점 용접의 연속 타점 수명에 미치는 전극 형상의 영향)

  • Choi, Dongsoon;Kang, Moonjin;Ryu, Jaewook;Kim, Dongcheol
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.4
    • /
    • pp.30-35
    • /
    • 2014
  • According to weight lightning trend of automobile body, necessity of resistance spot welding (RSW) of Mg alloy on automobile industry is increasing rapidly because of the highest specific strength among commercial metals. Mg alloy has low electric resistance and high thermal conductivity like as Al alloy, so that needs applying high current in short time when welding. Thick oxide film of Mg alloy pollutes the electrodes and makes partial current carrying paths when on welding. Partial current carrying paths signify excessive concentration of current. There can initiate expulsion easily and reduces electrode life rapidly. Generating partial current carrying paths and expulsions are influenced by shapes of electrode. Therefore, electrode life also influenced by shape. In this study, we perform life test of RSW electrode of radius type. Measure tensile shear load and nugget size every spot alternately. As a result, radius type electrode can extend life over twice as dome type electrode.

An Assessment Study for the Urban Air Monitoring Network in Seoul (서울지역 도시대기측정망 평가 연구)

  • Ghim, Young Sung;Choi, Yongjoo;Park, Ji Soo;Kim, Chan Hyuk
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.5
    • /
    • pp.504-509
    • /
    • 2014
  • Twenty-five stations of the urban monitoring network in Seoul were assessed with a focus on surveillance function of the exceedances of 8-hour ozone and 24-hour $PM_{10}$ standards. The two standards were selected because their attainment rates were particularly low. Two hierarchical cluster analyses were performed to group stations with similar atmospheric environments-one using daily highest 8-hour [$O_3+NO_2$], 8-hour $O_3$ concentrations plus corresponding 8-hour $NO_2$ concentrations considering the interconversion of $O_3$ and $NO_2$, and the other using 24-hour $PM_{10}$ concentrations. An index to measure higher concentration and exceedances of the standards was introduced. Within a cluster, sufficiently high score was assigned to the trends station or the station with higher index. Scores for $O_3+NO_2$ and $PM_{10}$ of a given station were added and ranked in the descending order to determine the relative importance.

Characteristics of Turbulent Nonpremixed Jet Flame in Cross Air Flow (주유동에 수직으로 분사되는 난류 비예혼합 분류 화염의 특성)

  • Lee, Kee-Man;Park, Jeong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.1
    • /
    • pp.125-132
    • /
    • 2002
  • An experimental study on the characteristics of stability of propane turbulent nonpremixed jet flames discharged normal to air free-streams with uniform velocity profile is conducted. Experimental observations are focused on the flame shape, the stability considering two kinds of flame, lift-off distance, and the flame length according to velocity ratio. In order to investigate the mixing structure of the flame base at the lower limit, we employ the RMS technique and measure the species concentration by a gas chromatography. In the results of the stability curve and lifted flame, it is fecund that the dependency of nozzle diameter is closely related to the large-scale vortical structure representing counter-rotating vortices pair. Also, the detailed discussion on the phenomenon of blowout due to this large vortical motion, is provided.