• Title/Summary/Keyword: concentration measure

Search Result 1,484, Processing Time 0.078 seconds

Generalized Measure of Departure From Global Symmetry for Square Contingency Tables with Ordered Categories

  • Tomizawa, Sadao;Saitoh, Kayo
    • Journal of the Korean Statistical Society
    • /
    • v.27 no.3
    • /
    • pp.289-303
    • /
    • 1998
  • For square contingency tables with ordered categories, Tomizawa (1995) considered two kinds of measures to represent the degree of departure from global symmetry, which means that the probability that an observation will fall in one of cells in the upper-right triangle of square table is equal to the probability that the observation falls in one of cells in the lower-left triangle of it. This paper proposes a generalization of those measures. The proposed measure is expressed by using Cressie and Read's (1984) power divergence or Patil and Taillie's (1982) diversity index. Special cases of the proposed measure include TomiBawa's measures. The proposed measure would be useful for comparing the degree of departure from global symmetry in several tables.

  • PDF

A Real Time Measurement of Ice Concentration of Ice Slurry in Pipe (배관내 흐르는 아이스슬러리의 실시간 얼음분율 측정)

  • Jung, Hae-Won;Peck, Jong-Hyeon;Kim, Yong-Chan;Kang, Chae-Dong;Hong, Hi-Ki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.8
    • /
    • pp.599-606
    • /
    • 2007
  • An experimental study was performed to measure a ice concentration of ice slurry flowing in a pipe in a real time. In the present paper, we suggested a measuring method by a refractive index and compared it to other methods by a freezing point and a density. To measure the refractive index of the solution, ice particles in the ice slurry should be completely removed and a hydro-cyclone was introduced instead of a mesh. The measuring method through the refractive index coincided with the density method using the real-time solution density within ${\pm}5%$ error range, having the error range less than the other two methods. In the other hand, the measuring method through the density has a good resolution, but the result using the initial density of the solution was different more than 10% error from that using the real-time density. And it has an error range 1.5 times greater than the method through the refractive index.

Concentration Distributions and A Reduction Strategy of Airborne Radon in Seoul Metropolitan Subway Stations (서울시 지하철역내의 라돈 농도분포 및 저감대책)

  • 김동술;김윤신;김신도;신응배;김성천;유정석
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.4
    • /
    • pp.271-277
    • /
    • 1993
  • Indoor radon has been known as one of the notorious carcinogens. However, a safe environmental criterion of radon has not yet been established in Korea, The main objectives of this study were to study concentration distributions of radon, to trace radon sources in subways, and to obtain a strategy for radon reduction in Seoul metropolitan area. Radon concentrations had been extensively determined by several steps. The first step was to survey radon levels in all of 83 subway stations from October to November in 1991. The second step was to select 40 out of 83 stations and then to study seasonal variations in 1991 and 1992. The third step was to monitor radon levels by hourly-basis plans. The fourth step was to seek a radon reduction strategy by altering ventilation at Ankuk station where had the highest radon concentration during the first measurement step. Each underground floor in the station was divided into 10 sites to measure hourly radon variations. The final step of the study was to measure radon concentrations in groundwater that is one of the possible main sources radon place. The result of the various measuring approaches showed short-and long-term radon variation and indicated radon reduction schemes.

  • PDF

Development of alcohol gas sensors measurable at room temperature (상온에서 측정 가능한 음주 측정용 알코올 가스 센서)

  • Jeon, Byung-Hyun;Lee, Ju-Hyuk;Kim, Seong-Jean;Lee, Cheol-Jin;Choi, Bok-Gil
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3265-3267
    • /
    • 1999
  • Capacitance-type alcohol gas sensors using porous silicon (PS) layer as sensitive film were fabricated to measure low alcohol gas concentration. Though sensors using porous silicon layer have show high sensitivity by large internal surface area, there is still much room for improvement to measure low breath alcohol concentration especially at room temperature. In this work, to discuss the response properties against exposure to organic vapor for breath alcohol measurements on the basis of experimental results. we measured the variation of the capacitance for the range of 0 to 0.5% alcohol concentration, and observed the improvement of sensitivity by illumination of UV light. In addition, the effect of CO2 and N2 gases involved commonly in exhaling breath was estimated, and the same procedure against methanol vapor was executed to compare qualitatively with the capacitance characteristics by alcohol vapor.

  • PDF

The quantitative analysis of combustive gases on fire by remote passive open path FT-IR spectrometer (Passive open-path FT-IR spectrometer를 사용한 원거리 화재 연소 가스 정량 분석)

  • Cho, Nam Wook;Cho, Won Bo;Kim, Hyo Jin
    • Analytical Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.120-124
    • /
    • 2013
  • It was studied to analyze the $CO_2$, CO, $SO_2$ standard gases of combustion gases by the open path FT-IR spectrometer with passive mode for remote analysis of air pollutant and volcano gases without IR lamp. As result, it was confirmed to have good linearity with more than 0.9 as correlation coefficients on the calibration curve of $CO_2$, CO concentration by MLR method. But in the case of $SO_2$, because the correlation coefficients were 0.88, the linearity could be lower. Finally, the concentration of three gases was predicted on in-site fire experiment under the condition of quantitative analysis. It could measure high $CO_2$ concentration as predicted result, but didn't measure the CO and $SO_2$. According to the result, it was possible to measure the combustion gases to long distance by only open path FT-IR spectrometer without infrared lamp.

A Study on the Improvement of Scaling Factor Determination Using Artificial Neural Network (인공신경망 이론을 이용한 척도인자 결정방법의 향상방안에 관한 연구)

  • Sang-Chul Lee;Ki-Ha Hwang;Sang-Hee Kang;Kun-Jai Lee
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.2 no.1
    • /
    • pp.35-40
    • /
    • 2004
  • Final disposal of radioactive waste generated from Nuclear Power Plant (NPP) requires the detailed information about the characteristics and the quantities of radionuclides in waste package. Most of these radionuclides are difficult to measure and expensive to assay. Thus it is suggested to the indirect method by which the concentration of the Difficult-to-Measure (DTM) nuclide is estimated using the correlations of concentration - it is called the scaling factor - between Easy-to-Measure (Key) nuclides and DTM nuclides with the measured concentration of the Key nuclide. In general, the scaling factor is determined by the log mean average (LMA) method and the regression method. However, these methods are inadequate to apply to fission product nuclides and some activation product nuclides such as 14$^{C}$ and 90$^{Sr}$ . In this study, the artificial neural network (ANN) method is suggested to improve the conventional SF determination methods - the LMA method and the regression method. The root mean squared errors (RMSE) of the ANN models are compared with those of the conventional SF determination models for 14$^{C}$ and 90$^{Sr}$ in two parts divided by a training part and a validation part. The SF determination models are arranged in the order of RMSEs as the following order: ANN model

  • PDF

A Study on the Measurement of Microbial Dehyrogenase Activity in Biological Treatment (생물학적 수처리에 있어서 미생물 탈수소효소 활성도 측정에 관한 연구)

  • 어경해;남상호
    • Journal of Environmental Health Sciences
    • /
    • v.15 no.2
    • /
    • pp.41-49
    • /
    • 1989
  • The assay on microbial dehydrogenase activity by using TTC was investigated. The experimental results are summarized as follows: 1. The TF production was affected by dissolved oxygen. Dissolved oxygen in samples could be effectively removed by adding $Na_{2}SO_{3}$ as reductant prior to incubation. 2. The toxic effect on TF formation was observed at up to 0.1% of final TTC concentration when VSS concentration was 2.7g/l. As the VSS concentration increased the effect decreased. 3. It was clearly revealed that the TF generation rate decreased with increasing VSS concentration. The dilution of sludge could be applicable when VSS level is below 3.5g/l. 4. The TF production of endogenous phase (De) could be used as a measure for the viable fraction of sludge over various sludge ages. The additional TF production (Ds) due to extracellular substrate responded to De, not to VSS concentration.

  • PDF

Prediction of Chlorine Concentration in a Pilot-Scaled Plant Distribution System (Pilot 규모의 모의 관망에서의 염소 농도 예측)

  • Kim, Hyun Jun;Kim, Sang Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.6
    • /
    • pp.861-869
    • /
    • 2012
  • The chlorine's residual concentration prevents the regrowth of microorganism in water transport along the pipeline system. Precise prediction of chlorine concentration is important in determining disinfectant injection for the water distribution system. In this study, a pilot scale water distribution system was designed and fabricated to measure the temporal variation of chlorine concentration for three flow conditions (V = 0.88, 1.33, 1.95 m/s). Various kinetic models were applied to identify the relationship between hydraulic condition and chlorine decay. Genetic Algorithm (GA) was integrated into five kinetic models and time series of chlorine were used to calibrate parameters. Model fitness was compared by Root Mean Square Error (RMSE) between measurement and prediction. Limited first order model and Parallel first order showed good fitness for prediction of chlorine concentration.

The Experimental Study on Simultaneous Measurements of $O_2$ Concentration and Temperature of Flue Gas Using a Single Diode Laser (다이오드 레이저를 이용한 배기가스 $O_2$ 농도 및 온도 동시 측정에 관한 실험적 연구)

  • Kim, Se-Won;Shin, Myoung-Chul;Lee, Chang-Yeop;Youn, Sung-Woon;Kim, Young-Il
    • Journal of the Korean Society of Combustion
    • /
    • v.17 no.1
    • /
    • pp.12-21
    • /
    • 2012
  • Simultaneous measurements of oxygen concentration and temperature using diode laser in the combustion environment are successfully accomplished. A single DFB type diode laser of 760 nm line centre frequency is used and the scanned-wavelength direct absorption spectroscopy method and wavelength modulation spectroscopy method are applied to measure absorption signals below 793 K temperature region. The experimental results show that oxygen concentration are measured within 1% accuracy and temperature are measured within 5% accuracy. This new method of simultaneous measurements of concentration and temperature with a single diode laser shows a great promise.