• Title/Summary/Keyword: concentration measure

Search Result 1,484, Processing Time 0.024 seconds

Serial venous lactate measurement following gastrointestinal surgery in horses

  • Smanik, Lauren E.;Moser, Darla K.;Rothers, Kris P.;Hackett, Eileen S.
    • Journal of Veterinary Science
    • /
    • v.23 no.5
    • /
    • pp.66.1-66.8
    • /
    • 2022
  • Background: Prospective clinical study of blood lactate concentration in horses undergoing colic surgery is needed to determine utility in outcome prediction. Objectives: To evaluate venous lactate measurements in horses following colic surgery, including immediately after anesthetic recovery and daily throughout hospitalization, as well as to determine if lactate concentrations were significantly higher in horses that developed postoperative complications or did not survive to hospital discharge. Methods: Horses > 1 year of age undergoing surgery for colic and recovered from general anesthesia were sampled. A portable lactate meter was used to measure venous samples collected immediately following anesthetic recovery and daily throughout hospitalization. Complications arising during hospitalization and survival to hospital discharge were recorded. Results: Fifty one horses were enrolled, ranging in age from 2 to 29 years. Lactate concentration immediately following anesthetic recovery was higher in horses that developed complications during hospitalization (p = 0.046). The odds of developing complications postoperatively were doubled for horses with a venous lactate concentration > 5 mmol/L. Lactate measurements in non-survivors were significantly higher compared to survivors by 96 h postoperatively (p < 0.006). Conclusions: Higher venous lactate concentrations in the postoperative colic period were associated with an increased risk of complications and death. Results suggest horses with higher venous lactate measurements in recovery are more likely to have postoperative complications, with the odds of developing complications doubled for horses with a venous lactate > 5 mmol/L. Evaluation of venous lactate could provide information on prognosis in the postoperative period for horses with surgical colic.

Metaverse Realistic Media Digital Content Development Education Environment Improvement Research

  • Kyoung-A, Lee
    • Journal of the Korea Society of Computer and Information
    • /
    • v.28 no.3
    • /
    • pp.67-73
    • /
    • 2023
  • Under the influence of COVID-19, as a measure of social distancing for about two years and one month, non-face-to-face services using ICT element technology are expanding not only to the education sector but to all fields. In particular, as educational programs using the Metaverse platform spread to various fields, educators, and learners have more learning experiences using Edutech, but problems through non-face-to-face learning such as reduced immersion or concentration in education are raising In this paper, to overcome the problems raised through non-face-to-face learning and develop metaverse immersive media digital contents to improve the educational environment, we utilize VR (Virtual Reality) based on an immersive metaverse to provide education / Training contents and the educational environment was established. In this paper, we presented a system to increase immersion and concentration in educational contents in a virtual environment using HMD (Head Mounted Display) for learners who are put into military education/training. Immersion was further improved.

Correlating two-dimensional shear wave elastography of acute pancreatitis with Spec cPL in dogs

  • Cho, Hyun;Yang, Seungwhwa;Suh, Gukhyun;Choi, Jihye
    • Journal of Veterinary Science
    • /
    • v.23 no.5
    • /
    • pp.79.1-79.11
    • /
    • 2022
  • Background: Pancreatitis is a common disease in which 37% of dogs had evidence of acute or chronic pancreatitis at necropsy. Although biopsy is still the gold standard to diagnose acute pancreatitis, clinical data including ultrasonographic findings and measurement of canine serum pancreatic lipase immunoreactivity (cPLI) are used in routine. However, it may be insufficient in the diagnostic approach to acute pancreatitis. Objectives: To evaluate the clinical diagnostic feasibility of two-dimensional shear wave elastography (2D SWE) on canine acute pancreatitis for enhanced diagnostic confidence. Methods: 2D SWE was used to assess pancreatic stiffness and determine the correlation between pancreatic shear wave velocity (SWV) and Spec cPL concentration in 31 dogs with healthy pancreas and 10 dogs with acute pancreatitis. Results: The pancreatic SWV was significantly higher in the acute pancreatitis group (2.67 ± 0.20 m/s) than in the healthy pancreas group (2.30 ± 0.26 m/s; p < 0.05). The moderate positive correlation was found between the pancreatic SWV and Spec cPL concentration (95% confidence interval, 0.214-0.693; r = 0.489; p < 0.05). Conclusions: These results indicated that 2D SWE was feasible for assessing pancreatic stiffness in acute pancreatitis, and that pancreatic SWV using 2D SWE correlated with Spec cPL concentration. SWE could provide a quantitative measure of pancreatic stiffness, which can increase the accuracy of diagnosing acute pancreatitis in dogs. The 2D SWE can be used as a complementary imaging modality for diagnosing acute pancreatitis in dogs.

Decomposition of Socioeconomic Inequality in Cardiovascular Disease Prevalence in the Adult Population: A Cohort-based Cross-sectional Study in Northwest Iran

  • Pourfarzi, Farhad;Moghadam, Telma Zahirian;Zandian, Hamed
    • Journal of Preventive Medicine and Public Health
    • /
    • v.55 no.3
    • /
    • pp.297-306
    • /
    • 2022
  • Objectives: The incidence of cardiovascular disease (CVD) mortality is increasing in developing countries. This study aimed to decompose the socioeconomic inequality of CVD in Iran. Methods: This cross-sectional population-based study was conducted on 20 519 adults who enrolled in the Ardabil Non-Communicable Disease cohort study. Principal component analysis and multivariable logistic regression were used, respectively, to estimate socioeconomic status and to describe the relationships between CVD prevalence and the explanatory variables. The relative concentration index, concentration curve, and Blinder-Oaxaca decomposition model were used to measure and decompose the socioeconomic inequality. Results: The overall age-adjusted prevalence of CVD was 8.4% in northwest Iran. Multivariable logistic regression showed that older adults, overweight or obese adults, and people with hypertension and diabetes were more likely to have CVD. Moreover, people with low economic status were 38% more likely to have CVD than people with high economic status. The prevalence of CVD was mainly concentrated among the poor (concentration index, -0.077: 95% confidence interval, -0.103 to -0.060), and 78.66% of the gap between the poorest and richest groups was attributed to differences in the distribution of the explanatory variables included in the model. Conclusions: The most important factors affecting inequality in CVD were old age, chronic illness (hypertension and diabetes), marital status, and socioeconomic status. This study documented stark inequality in the prevalence of CVD, wherein the poor were more affected than the rich. Therefore, it is necessary to implement policies to monitor, screen, and control CVD in poor people living in northwest Iran.

Relationship between Steady Flow and Dynamic Rheological Properties for Viscoelastic Polymer Solutions - Examination of the Cox-Merz Rule Using a Nonlinear Strain Measure - (점탄성 고분자 용액의 정상유동특성과 동적 유변학적 성질의 상관관계 -비선헝 스트레인 척도를 사용한 Cox-Merz 법칙의 검증-)

  • 송기원;김대성;장갑식
    • The Korean Journal of Rheology
    • /
    • v.10 no.4
    • /
    • pp.234-246
    • /
    • 1998
  • The objective of this study is to investigate the correlation between steady shear flow (nonlinear behavior) and dynamic viscoelastic (linear behavior) properties for concentrated polymer solutions. Using both an Advanced Rheometic Expansion System(ARES) and a Rheometics Fluids Spectrometer (RFS II), the steady shear flow viscosity and the dynamic viscoelastic properties of concentrated poly(ethylene oxide)(PEO), polyisobutylene(PIB), and polyacrylamide(PAAm) solutions have been measured over a wide range of shear rates and angular frequencies. The validity of some previously proposed relationships was compared with experimentally measured data. In addition, the effect of solution concentration on the applicability of the Cox-Merz rule was examined by comparing the steady flow viscosity and the magnitude of the complex viscosity Finally, the applicability of the Cox-Merz rule was theoretically discussed by introducing a nonlinear strain measure. Main results obtained from this study can be summarized as follows : (1) Among the previously proposed relationships dealt with in this study, the Cox-Merz rule implying the equivalence between the steady flow viscosity and the magnitude of the complex viscosity has the best validity. (2) For polymer solutions with relatively lower concentration, the steady flow viscosity is higher than the complex viscosity. However, such a relation between the two viscosities is reversed for highly concentrated polymer solutions. (3) A nonlinear strain measure is decreased with increasing stran magnitude, after reaching the maximum value in small strain range. This behavior is different from the theoretical prediction demonstrating the shape of a damped oscillatory function. (4) The applicability of the Cox-Merz rule is influenced by the $\beta$ value, which indicates the slope of a nonlinear stain measure (namely, the degree of nonlinearity) at large shear deformations. The Cox-Merz rule shows better applicability as the $\beta$ value becomes smaller.

  • PDF

Compensation of Light Scattering Method for Real-Time Monitoring of Particulate Matters in Subway Stations (지하역사 내 미세먼지 실시간 모니터링을 위한 광산란법 보정)

  • Kim, Seo-Jin;Kang, Ho-Seong;Son, Youn-Suk;Yoon, Sang-Lyeor;Kim, Jo-Chun;Kim, Gyu-Sik;Kim, In-Won
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.5
    • /
    • pp.533-542
    • /
    • 2010
  • The $PM_{10}$ concentrations in the underground should be monitored for the health of commuters on the underground subway system. Seoul Metro and Seoul Metropolitan Rapid Transit Corporation are measuring several air pollutants regularly. As for the measurement of $PM_{10}$ concentrations, instruments based on $\beta$-ray absorption method and gravimetric methods are being used. But the instruments using gravimetric method give us 20-hour-average data and the $\beta$-ray instruments can measure the $PM_{10}$ concentration every one hour. In order to keep the $PM_{10}$ concentrations under a healthy condition, the air quality of the underground platform and tunnels should be monitored and controlled continuously. The $PM_{10}$ instruments using light scattering method can measure the $PM_{10}$ concentrations every less than one minute. However, the reliability of the instruments using light scattering method is still not proved. The purpose of this work is to study the reliability of the instruments using light scattering method to measure the $PM_{10}$ concentrations continuously in the underground platforms. One instrument using $\beta$-ray absorption method and two different instruments using light scattering method (LSM1, LSM2) were placed at the platform of the Jegi station of Seoul metro line Number 1 for 10 days. The correlation between the $\beta$-ray instrument and the LSM2 ($r^2$=0.732) was higher than that between the $\beta$-ray instrument and the LSM1 ($r^2$=0.393). Thus the LSM2 was chosen for further analysis. Three different regression analysis methods were tested: Linear regression analysis, Nonlinear regression analysis and Orthogonal regression analysis. When the instruments using light scattering method were used, the data measured these instruments have to be converted to actual $PM_{10}$ concentrations using some factors. With these analyses, the factors could be calculated successfully as linear and nonlinear forms with respect to the data. And the orthogonal regression analysis was performed better than the ordinary least squares method by 28.45% reduction of RMSE. These findings propose that the instruments using light scattering method light scattering method can be used to measure and control the $PM_{10}$ concentrations of the underground subway stations.

A Review of the Characteristics of Early Apparatus and Methods for Hemoglobin Estimation (Hemoglobin 평가를 위한 초기 기구의 특성 및 측정법 고찰)

  • Kwon, Young-Il
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.48 no.4
    • /
    • pp.401-410
    • /
    • 2016
  • Since the late 19th century, scientific logic and techniques have been used extensively in the field of clinical pathology, including many laboratory tests utilizing various apparatuses and instruments. Among the techniques to measure hemoglobin, the visual color comparison method was most popular around this time; the specific gravity method and gasometric method were not widely adopted. Instruments that use the visual color comparison method include Gowers' hemoglobinometer, von Fleischl's hemoglobinometer, Dare's hemoglobinometer, Oliver's hemoglobinometer, Haden-Hausser hemoglobinometer, and Spencer Hb meter. Initially, the visual color comparison methods were used to diluate and hemolyze blood with distilled water and then to measure its color. Later, these methods were further developed to measure hemoglobin without dilution, and improved with the formation of acid or alkaline hematin ensuring the stability of color development. Hammerschlag's method as well as the Schmaltz and Peiper's methods were based on specific gravity measurement, but they were not widely used. The gasometric method used the Van Slyke gasometer, indirectly measuring the hemoglobin concentration. This method provides the most accurate results. This survey examined the characteristics and limitations of hemoglobinometers and methods used to measure hemoglobin from the late 19th century to the early-and mid-20th century. Moreover, this study aims to improve the understanding and applicability of the current methods and emerging technologies used in measuring hemoglobin. It is also expected that this investigation is the starting point to promote awareness of the need to organize historical data for a variety of historical relics of the diagnostic laboratory tests.

Continuous Water Toxicity Monitoring Using Immobilized Photobacterium phosphoreum

  • Kim, Se-Kwon;Lee, Baek-Seok;Lee, Jeong-Gun;Seo, Hyung-Joon;Kim, Eun-Ki
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.8 no.2
    • /
    • pp.147-150
    • /
    • 2003
  • Water toxicity monitoring based on the continuous cultivation of Photobacterium phorphoreum is presented. Normally, after 10 days of operation, a dark variant, which emits no light, appears and dominates the population, resulting in a rapid decrease in bioluminescence. Therefore, to overcome this problem, a fluidized-bed reactor is used in which alginate-immobilized cells are grown and leaking cells are continuously released into the effluent Experimental results revealed that the dominance of dark variants was suppressed inside the immobilized beads, thereby mitigating the rapid loss of bioluminescence. Plus, a high dilution rate (1.2 h$\^$-1/) prevented the occurrence of other microbial contamination in the reactor The concentration and bioluminescence of the released cells were sufficient to measure the water toxicity for more than 4 weeks.

Effect of Fuel Mixing on PAH and Soot Formation in Counterflow Diffusion Flames (다양한 연료의 혼합에 따른 대향류 확산화염에서의 PAH 및 매연생성 특성)

  • Yoon, S.S.;Lee, S.M.;Chung, S.H.
    • 한국연소학회:학술대회논문집
    • /
    • 2003.05a
    • /
    • pp.137-142
    • /
    • 2003
  • In order to investigate the effect of fuel mixing on PAH and soot formation, four species of methane, ethane, propane and propene have been mixed in counterlfow ethylene diffusion flame. Laser-induced incandescene and laser-induced fluorescene techniques were employed to measure soot volume fraction and polycyclic aromatic hydrocarbon (PAH) concentration, respectively. Results showed that the mixing of ethane (or propane) in ethylene diffusion flame produces more PAHs and soot than those of propene, even though the propene diffusion flame produces more PAHs and soot than that of propane and ethane. Considering that propene directly dehydrogenates to propargyl radical, this behavior implied that the enhancement of PAH and soot formation by the fuel mixing of ethylene and ethane (or propane) cannot be explained by propargyl radical directly dehydrogenated from ethane (or propane).

  • PDF

Measurement of Exhaust Gas Concentration using Wavelength Modulation Spectroscopy (파장 변조 기법을 이용한 연소배기 가스의 계측)

  • Kim, Dong-Hyuck;Kim, Se-Won;Shin, Myung-Chul;Kim, Yong-Mo
    • 한국연소학회:학술대회논문집
    • /
    • 2006.10a
    • /
    • pp.97-103
    • /
    • 2006
  • This work forcus on the development of gas sensor that measure the concentrations of exhaust gas using diode laser. Each diode laser for exhaust gas measurement is set to work at near-IR using both DA and WMS methods. Also use of fiber-coupled optical elements makes such a sensor rugged and easy to align. On-line data acquisition and processing can be performed with a PC running LabVIEW software, and absorption signals are measured simultaneously by multiplexing method. Finally, It were experimentally compared WMS (Wavelength Modulation Spectroscopy) with DA (Direct Absorption) for the accuracy.

  • PDF